Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). November 20,2019 Liu, Xuegang Pages or sheets covered by this seal: I39348327 thru I39348363 My license renewal date for the state of Indiana is July 31, 2020. TG-191 Pyatt Builders - 82 TG IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss CG01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348327 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:22 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-CEApVcR?HTpdWTC8qqz9g5f3lqIAk_zwTHmvCcyHZD? Scale = 1:13.3 1 2 5 3 6 4 3x4 5-5-65-5-6 -1-5-0 1-5-0 5-5-6 5-5-6 0-5-11-10-60-4-01-6-61-10-63.18 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.43 0.32 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.11 -0.00 (loc) 2-4 2-4 3 l/defl >999 >571 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=141/Mechanical, 2=319/0-4-9, 4=52/Mechanical Max Horz 2=47(LC 3) Max Uplift 3=-31(LC 3), 2=-40(LC 3) Max Grav 3=141(LC 1), 2=319(LC 1), 4=104(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 11 lb down and 17 lb up at 2-7-12, and 11 lb down and 17 lb up at 2-7-12 on top chord, and at 2-7-12, and at 2-7-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 2-4=-20 November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348328 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:23 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-gRkBiyRd1nxT8dnKOXUODIBC4EcrTOa3hxVSk3yHZD_ Scale = 1:62.9 1 2 3 4 5 6 7 8 9 10 11 12 21 20 18 17 16 15 14 13 22 43 44 45 46 19 3x6 4x8 3x4 3x6 4x8 3x4 3x6 3x6 3x4 2x4 3x6 2x4 3x8 3x4 2x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-5-138-5-13 12-4-83-10-11 16-8-34-3-11 25-2-08-5-13 -1-0-0 1-0-0 6-5-4 6-5-4 12-7-0 6-1-12 18-8-12 6-1-12 25-2-0 6-5-4 26-2-0 1-0-0 0-9-09-1-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-9,0-0-3], [7:0-1-8,0-1-8], [11:0-4-13,Edge], [16:0-2-0,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.52 0.49 0.23 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.26 0.03 (loc) 21-37 21-37 2 l/defl >999 >582 n/a L/d 240 180 n/a PLATES MT20 Weight: 145 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 7-16,7-21: 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-16 JOINTS 1 Brace at Jt(s): 22 REACTIONS.All bearings 12-9-8 except (jt=length) 2=0-3-8, 19=0-3-8. (lb) - Max Horz 2=-145(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 16, 11, 18, 13 Max Grav All reactions 250 lb or less at joint(s) 18, 17, 15, 14, 13, 19 except 2=713(LC 1), 16=639(LC 1), 11=356(LC 14), 11=352(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-723/83, 4-5=-585/95, 5-7=-461/110, 9-11=-282/104 BOT CHORD 2-21=0/568, 19-21=0/452, 18-19=0/452 WEBS 7-16=-324/0, 9-16=-342/135, 21-22=0/328, 7-22=0/328, 18-22=-310/81, 5-22=-308/82 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-7-0, Exterior(2) 12-7-0 to 15-7-0, Interior(1) 15-7-0 to 26-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 16, 11, 18, 13, 11. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE02 Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348329 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:24 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-9dIZwISFo53KmmLWyF?dlWkUte3?CunDwbF?FVyHZCz Scale = 1:30.7 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 4x6 3x6 3x4 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-8-012-8-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-9-04-11-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-1,0-0-3], [10:0-4-1,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.07 0.04 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 10 11 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-7-2, Right 2x4 SPF-S Stud 1-7-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-8-0. (lb) - Max Horz 2=-78(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 15, 16, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 14, 15, 16, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 6-4-0, Corner(3) 6-4-0 to 9-4-0, Exterior(2) 9-4-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 15, 16, 13, 12. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE03 Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348330 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:25 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-dpsx7eTtZOBBNwwiVyXsIjHfd2PyxK8M9F_ZoxyHZCy Scale = 1:41.1 1 2 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 14 4x6 3x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x4 17-8-017-8-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 18-8-0 1-0-0 0-9-06-7-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-5,0-0-7], [12:0-3-5,0-0-7], [17:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.07 0.06 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 12 12 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-8-2, Right 2x4 SPF-S Stud 1-8-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-8-0. (lb) - Max Horz 2=-105(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 18, 19, 20, 16, 15, 14, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 17, 18, 19, 20, 16, 15, 14, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 8-10-0, Corner(3) 8-10-0 to 11-10-0, Exterior(2) 11-10-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 19, 20, 16, 15, 14, 12. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348331 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:26 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-5?PKL_UVKiJ2?4Vv3g25rxppRRk8gmlWNvk6KNyHZCx Scale = 1:71.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 3x6 3x6 4x6 3x6 3x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 31-6-031-6-0 15-9-0 15-9-0 31-6-0 15-9-0 0-9-011-3-00-9-08.00 12 Plate Offsets (X,Y)-- [1:0-1-3,0-1-12], [19:0-1-3,0-1-12], [19:Edge,0-3-8], [20:0-0-0,0-1-12], [28:0-3-0,0-3-0], [36:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.13 0.06 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a -0.00 (loc) - - 20 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 171 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 10-28,9-29,8-30,11-27,12-26: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-28, 9-29, 8-30, 11-27, 12-26 REACTIONS.All bearings 31-6-0. (lb) - Max Horz 36=-186(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 36, 20, 29, 30, 31, 32, 33, 34, 35, 27, 26, 25, 24, 23, 22, 21 Max Grav All reactions 250 lb or less at joint(s) 36, 20, 28, 29, 30, 31, 32, 33, 34, 35, 27, 26, 25, 24, 23, 22, 21 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=32ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-1-12 to 3-3-9, Exterior(2) 3-3-9 to 15-9-0, Corner(3) 15-9-0 to 18-10-13, Exterior(2) 18-10-13 to 31-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 36, 20, 29, 30, 31, 32, 33, 34, 35, 27, 26, 25, 24, 23, 22, 21. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE04A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348332 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ZCziYKV750RvdE45dNZKN8Mqdry5PBEfcZTgsqyHZCw Scale = 1:74.0 1 2 3 4 5 6 7 8 9 10 11 20 19 17 16 15 14 13 12 21 44 45 46 47 48 49 18 50 51 3x6 4x8 3x8 3x8 3x4 5x8 3x6 2x4 3x6 2x4 4x10 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-0-48-0-4 15-9-07-8-12 16-4-00-7-0 23-9-07-5-0 31-6-07-9-0 -1-0-0 1-0-0 8-0-4 8-0-4 15-9-0 7-8-12 23-9-0 8-0-0 31-6-0 7-9-0 0-9-011-3-00-9-08.00 12 Plate Offsets (X,Y)-- [2:0-4-13,Edge], [11:0-4-13,Edge], [19:0-3-8,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.81 0.53 0.32 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.21 0.03 (loc) 20-38 20-38 2 l/defl >999 >920 n/a L/d 240 180 n/a PLATES MT20 Weight: 182 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 9-14,4-20: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 28-29: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19, 9-19, 4-19, 5-21 REACTIONS.All bearings 15-5-8 except (jt=length) 2=0-3-8, 18=0-3-8. (lb) - Max Horz 2=182(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 14, 11, 13 except 18=-540(LC 2) Max Grav All reactions 250 lb or less at joint(s) 17, 16, 15, 13, 12 except 2=835(LC 1), 19=1379(LC 1), 14=324(LC 1), 11=399(LC 1), 11=399(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-891/122, 9-11=-378/185 BOT CHORD 2-20=-7/692, 19-20=-7/692, 18-19=-63/299, 17-18=-63/299, 16-17=-63/299, 15-16=-63/299, 14-15=-63/299, 13-14=-63/299, 12-13=-63/299, 11-12=-63/299 WEBS 19-21=-376/0, 7-21=-340/0, 9-19=-301/165, 4-19=-735/92, 4-20=0/381 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=32ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-1-13, Interior(1) 2-1-13 to 15-9-0, Exterior(2) 15-9-0 to 18-10-13, Interior(1) 18-10-13 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 14, 11, 13, 11 except (jt=lb) 18=540. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE05 Truss Type Common Supported Gable Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348333 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:27 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ZCziYKV750RvdE45dNZKN8M?7r4xPE7fcZTgsqyHZCw Scale = 1:38.4 1 2 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 14 4x6 3x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x4 16-4-016-4-0 -1-0-0 1-0-0 8-2-0 8-2-0 16-4-0 8-2-0 17-4-0 1-0-0 0-9-06-2-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-5,0-0-7], [12:0-3-5,0-0-7], [17:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.07 0.03 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 13 13 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-7-3, Right 2x4 SPF-S Stud 1-7-3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-4-0. (lb) - Max Horz 2=-97(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 18, 19, 20, 16, 15, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 17, 18, 19, 20, 16, 15, 14, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-2-0, Exterior(2) 2-2-0 to 8-2-0, Corner(3) 8-2-0 to 11-2-0, Exterior(2) 11-2-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 19, 20, 16, 15, 14. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE06 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348334 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:28 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-1OX4lfVlsJZmEOfHB54ZwMvAkFQg8iZprDDDOGyHZCv Scale = 1:38.1 1 2 3 4 5 6 7 8 9 10 11 12 13 22 21 20 19 18 17 16 15 14 23 24 25 26 4x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 21-8-021-8-0 -1-0-0 1-0-0 10-10-0 10-10-0 21-8-0 10-10-0 22-8-0 1-0-0 0-5-104-11-130-5-105.00 12 Plate Offsets (X,Y)-- [18:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.08 0.06 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 12 13 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 21-8-0. (lb) - Max Horz 2=50(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 19, 20, 21, 22, 17, 12, 16, 15, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 18, 19, 20, 21, 22, 17, 12, 16, 15, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 10-10-0, Corner(3) 10-10-0 to 13-10-0, Exterior(2) 13-10-0 to 22-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 19, 20, 21, 22, 17, 12, 16, 15, 14. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE07 Truss Type Monopitch Supported Gable Qty 2 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348335 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Va5Sz?WOddhdsYEUkoboSZRL6flWt9iy4tymxiyHZCu Scale = 1:10.5 1 2 3 4 5 2x4 2x4 2x4 -1-0-0 1-0-0 2-11-8 2-11-8 0-5-11-6-64.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.10 0.09 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=102/2-11-8, 2=183/2-11-8 Max Horz 2=36(LC 6) Max Uplift 2=-25(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 2-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss GE09 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348336 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Va5Sz?WOddhdsYEUkoboSZRLIfljt8dy4tymxiyHZCu Scale = 1:14.2 1 2 3 4 6 5 7 2x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 4-11-8 4-11-8 0-5-12-3-64.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.09 0.07 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=43/4-11-8, 2=169/4-11-8, 6=232/4-11-8 Max Horz 2=57(LC 6) Max Uplift 5=-2(LC 6), 2=-21(LC 9), 6=-1(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) -1-0-0 to 2-0-0, Exterior(2) 2-0-0 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss J01 Truss Type Jack-Open Qty 4 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348337 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:29 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Va5Sz?WOddhdsYEUkoboSZRKnfkYt9iy4tymxiyHZCu Scale = 1:12.2 1 2 5 6 3 4 2x4 3-10-123-10-12 -1-0-0 1-0-0 3-10-12 3-10-12 0-5-11-10-101-6-51-10-94.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.19 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 -0.00 (loc) 2-4 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=100/Mechanical, 2=227/0-3-8, 4=37/Mechanical Max Horz 2=45(LC 9) Max Uplift 3=-24(LC 9), 2=-21(LC 9) Max Grav 3=100(LC 1), 2=227(LC 1), 4=74(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss J02 Truss Type Jack-Open Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348338 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-znfqALX0OxpUUhpgIV61?n_VH36Uccy5IXiKT9yHZCt Scale = 1:8.5 1 2 3 4 2x4 1-11-31-11-3 -1-0-0 1-0-0 1-11-3 1-11-3 0-5-11-1-120-4-50-9-71-1-124.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=40/Mechanical, 2=154/0-3-8, 4=19/Mechanical Max Horz 2=28(LC 9) Max Uplift 3=-8(LC 9), 2=-25(LC 9) Max Grav 3=40(LC 1), 2=154(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss J03 Truss Type Jack-Open Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348339 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:30 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-znfqALX0OxpUUhpgIV61?n_VH36Uccy5IXiKT9yHZCt Scale = 1:8.5 1 2 3 4 2x4 1-11-31-11-3 -1-0-0 1-0-0 1-11-3 1-11-3 0-5-11-1-120-9-71-1-124.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 2 2-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)3=40/Mechanical, 2=154/0-3-8, 4=19/Mechanical Max Horz 2=28(LC 9) Max Uplift 3=-8(LC 9), 2=-25(LC 9) Max Grav 3=40(LC 1), 2=154(LC 1), 4=38(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss JG01 Truss Type Half Hip Girder Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348340 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-RzDDOhYe9ExL5rOssDeGY_XTfSJ3L_bFXBRt?byHZCs Scale = 1:19.7 1 2 3 4 6 5 7 8 9 10 11 12 6x6 3x8 4x6 3x6 2x4 3-10-123-10-12 10-7-86-8-12 -1-0-0 1-0-0 3-10-12 3-10-12 10-7-8 6-8-12 0-5-11-9-41-10-101-9-44.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.93 0.59 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.24 0.02 (loc) 5-6 5-6 5 l/defl >999 >507 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-1-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-5REACTIONS.(lb/size)5=606/0-3-8, 2=616/0-3-8 Max Horz 2=44(LC 14) Max Uplift 5=-17(LC 4), 2=-26(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1221/0, 4-5=-295/74 BOT CHORD 2-6=-6/1105, 5-6=-18/1088 WEBS 3-6=0/382, 3-5=-938/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 143 lb down and 86 lb up at 3-10-12, 40 lb down and 36 lb up at 5-11-8, and 40 lb down and 36 lb up at 7-11-8, and 54 lb down and 33 lb up at 9-11-8 on top chord, and 81 lb down at 3-10-12, 34 lb down at 5-11-8, and 34 lb down at 7-11-8, and 43 lb down at 9-11-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 2-5=-20 Concentrated Loads (lb) Vert: 3=-96(B) 6=-41(B) 7=-40(B) 8=-40(B) 9=-54(B) 10=-17(B) 11=-17(B) 12=-22(B) November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss LAY01 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348341 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:31 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-RzDDOhYe9ExL5rOssDeGY_XY4SSgL2BFXBRt?byHZCs Scale = 1:40.0 1 2 3 4 7 6 52x4 2x4 2x4 2x4 2x4 2x4 2x4 6-3-15 6-3-15 0-0-46-9-112.82 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.58 0.04 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-3-15. (lb) - Max Horz 1=174(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 6 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-402/124, 2-3=-291/91 NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Corner(3) 0-4-1 to 4-6-15, Exterior(2) 4-6-15 to 6-2-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T01 Truss Type Common Qty 5 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348342 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:32 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-w9nbb1YGwY3Cj?z3Qw9V4C3m7sd04T8OmrBRX1yHZCr Scale = 1:53.9 1 2 3 4 5 6 7 8 9 10 11 14 13 12 23 24 25 26 27 28 3x6 4x6 3x6 5x8 3x4 3x8 3x6 2x4 3x6 2x4 5x8 3x4 8-5-138-5-13 16-8-38-2-5 25-2-08-5-13 -1-0-0 1-0-0 6-5-4 6-5-4 12-7-0 6-1-12 18-8-12 6-1-12 25-2-0 6-5-4 26-2-0 1-0-0 0-9-09-1-110-9-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.44 0.74 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.31 -0.45 0.06 (loc) 12-14 12-14 10 l/defl >990 >668 n/a L/d 240 180 n/a PLATES MT20 Weight: 101 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-12,4-14: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1157/0-3-8, 10=1157/0-3-8 Max Horz 2=-145(LC 7) Max Uplift 2=-11(LC 9), 10=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1506/70, 4-6=-1386/132, 6-8=-1386/132, 8-10=-1506/70 BOT CHORD 2-14=0/1185, 12-14=0/819, 10-12=0/1185 WEBS 6-12=-26/606, 8-12=-309/133, 6-14=-26/606, 4-14=-309/133 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-7-0, Exterior(2) 12-7-0 to 15-7-0, Interior(1) 15-7-0 to 26-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T02 Truss Type Common Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348343 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-OMKzpNZuhrB3L9XFzegkdPczaG3vpxXY_Vw_4TyHZCq Scale = 1:30.5 1 2 3 4 5 6 7 8 17 18 19 20 3x8 3x4 3x8 3x4 2x4 4x6 6-4-06-4-0 12-8-06-4-0 -1-0-0 1-0-0 6-4-0 6-4-0 12-8-0 6-4-0 13-8-0 1-0-0 0-9-04-11-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-4-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.26 0.38 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.09 0.03 (loc) 8-15 8-15 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=567/0-3-8, 6=567/0-3-8 Max Horz 2=-78(LC 7) Max Uplift 2=-17(LC 9), 6=-17(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-517/65, 4-6=-517/65 BOT CHORD 2-8=0/389, 6-8=0/389 WEBS 4-8=0/276 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-4-0, Exterior(2) 6-4-0 to 9-4-0, Interior(1) 9-4-0 to 13-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T03 Truss Type Common Qty 2 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348344 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:33 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-OMKzpNZuhrB3L9XFzegkdPcuDG_9pvDY_Vw_4TyHZCq Scale = 1:39.6 1 2 3 4 5 6 7 8 17 18 19 20 21 22 4x10 3x4 5x12 4x6 4x10 3x4 8-10-08-10-0 17-8-08-10-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 18-8-0 1-0-0 0-9-06-7-110-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-4-13,Edge], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.61 0.68 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.34 0.07 (loc) 8-11 8-11 2 l/defl >999 >619 n/a L/d 240 180 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=916/0-3-8, 6=916/0-3-8 Max Horz 2=105(LC 8) Max Uplift 2=-14(LC 9), 6=-14(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1022/84, 4-6=-1022/84 BOT CHORD 2-8=0/754, 6-8=0/754 WEBS 4-8=0/524 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T04 Truss Type Common Qty 9 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348345 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-sYuL0jaWS9JwyJ6RXLBz9d83ngHFYM0hD9gXcwyHZCp Scale = 1:66.0 1 2 3 4 5 6 7 8 9 12 11 10 21 22 23 24 25 26 27 28 3x6 4x6 3x6 6x8 3x6 5x8 3x6 2x4 3x6 2x4 6x8 3x6 8-0-48-0-4 15-9-07-8-12 23-5-127-8-12 31-6-08-0-4 8-0-4 8-0-4 15-9-0 7-8-12 23-5-12 7-8-12 31-6-0 8-0-4 0-9-011-3-00-9-08.00 12 Plate Offsets (X,Y)-- [11:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.62 0.82 0.32 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.30 0.10 (loc) 11-12 11-12 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 127 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 7-10,3-12: 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-11, 3-11 REACTIONS.(lb/size)1=1483/Mechanical, 9=1483/Mechanical Max Horz 1=-174(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2099/77, 3-5=-1456/137, 5-7=-1456/137, 7-9=-2099/77 BOT CHORD 1-12=0/1661, 11-12=0/1661, 10-11=0/1661, 9-10=0/1661 WEBS 5-11=-26/1029, 7-11=-730/105, 7-10=0/343, 3-11=-730/105, 3-12=0/343 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=32ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-0-0 to 3-1-13, Interior(1) 3-1-13 to 15-9-0, Exterior(2) 15-9-0 to 18-10-13, Interior(1) 18-10-13 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T04A Truss Type Roof Special Qty 3 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348346 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:34 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-sYuL0jaWS9JwyJ6RXLBz9d84hgIuYBHhD9gXcwyHZCp Scale = 1:74.6 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 13 12 1615 14 29 30 31 32 33 34 3x6 4x6 3x6 5x8 3x6 3x6 3x4 5x12 3x8 5x6 6x8 3x6 3x6 3x12 5x8 6x8 3x6 5x6 2x4 8-0-48-0-4 15-10-127-10-8 17-4-01-5-4 20-4-03-0-0 23-5-123-1-12 31-6-08-0-4 -1-0-0 1-0-0 8-0-4 8-0-4 15-9-0 7-8-12 20-4-0 4-7-0 23-5-12 3-1-12 31-6-0 8-0-4 0-9-011-3-00-9-02-0-08.00 12 Plate Offsets (X,Y)-- [2:0-4-13,Edge], [12:0-3-8,0-2-8], [13:0-2-7,0-2-14], [14:0-6-0,0-4-12], [16:0-4-0,0-2-8], [17:0-2-9,0-2-14], [20:0-3-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.56 0.71 1.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.29 0.16 (loc) 14 18-20 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 153 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-13,13-17: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud *Except* 4-16: 2x4 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. Except: 6-0-0 oc bracing: 13-14 10-0-0 oc bracing: 14-15 WEBS 1 Row at midpt 4-16, 7-16 JOINTS 1 Brace at Jt(s): 16, 14 REACTIONS.(lb/size)2=1438/0-3-8, 11=1376/Mechanical Max Horz 2=182(LC 8) Max Uplift 2=-8(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1911/71, 4-6=-1588/108, 6-7=-1516/118, 7-9=-2203/99, 9-11=-1902/78 BOT CHORD 2-20=0/1508, 11-12=0/1492, 16-18=0/256, 6-16=-16/1235, 15-16=0/1775, 14-15=0/1780, 7-14=-18/910 WEBS 16-20=0/1480, 4-16=-407/117, 7-16=-902/66, 12-14=0/1834, 9-14=0/426, 9-12=-853/29 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=32ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-1-13, Interior(1) 2-1-13 to 15-9-0, Exterior(2) 15-9-0 to 18-10-13, Interior(1) 18-10-13 to 31-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T05 Truss Type Common Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348347 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:35 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-KkSjE3b8DTRmaThd53iCiqhGI4cGHqLqSpP58MyHZCo Scale = 1:37.6 1 2 3 4 5 6 7 8 17 18 19 20 21 22 4x8 3x4 5x12 4x6 4x8 3x4 8-2-08-2-0 16-4-08-2-0 -1-0-0 1-0-0 8-2-0 8-2-0 16-4-0 8-2-0 17-4-0 1-0-0 0-9-06-2-50-9-08.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [6:0-4-13,Edge], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MS 0.51 0.90 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.28 0.06 (loc) 8-11 8-11 2 l/defl >999 >689 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-11-0, Right 2x4 SPF-S Stud 1-11-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=836/0-3-8, 6=836/0-3-8 Max Horz 2=-97(LC 7) Max Uplift 2=-15(LC 9), 6=-15(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-913/68, 4-6=-913/68 BOT CHORD 2-8=0/674, 6-8=0/674 WEBS 4-8=0/451 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-2-0, Exterior(2) 8-2-0 to 11-2-0, Interior(1) 11-2-0 to 17-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T06 Truss Type Common Qty 3 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348348 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ox06RPcn_mZdCcGqfmDRF2ES7TwP0Ej_hS9ehoyHZCn Scale = 1:37.9 1 2 3 4 5 6 7 8 9 10 11 12 4x6 4x6 5x12 2x4 2x4 4x6 10-10-010-10-0 21-8-010-10-0 -1-0-0 1-0-0 5-7-0 5-7-0 10-10-0 5-3-0 16-1-0 5-3-0 21-8-0 5-7-0 22-8-0 1-0-0 0-5-104-11-130-5-105.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-11], [6:0-0-0,0-0-11], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.44 0.97 0.37 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.28 -0.73 0.06 (loc) 2-8 2-8 6 l/defl >923 >349 n/a L/d 240 180 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS.(lb/size)2=924/0-3-8, 6=924/0-3-8 Max Horz 2=50(LC 8) Max Uplift 2=-16(LC 9), 6=-16(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1580/105, 3-4=-1194/56, 4-5=-1194/56, 5-6=-1580/105 BOT CHORD 2-8=-44/1401, 6-8=-49/1401 WEBS 4-8=0/614, 5-8=-422/123, 3-8=-422/123 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 10-10-0, Exterior(2) 10-10-0 to 13-10-0, Interior(1) 13-10-0 to 22-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T07 Truss Type MONOPITCH Qty 6 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348349 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:36 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ox06RPcn_mZdCcGqfmDRF2EXVT8H0JR_hS9ehoyHZCn Scale = 1:10.5 1 2 3 4 5 2x4 2x4 2x4 2-11-82-11-8 -1-0-0 1-0-0 2-10-0 2-10-0 2-11-8 0-1-8 0-5-11-6-61-2-140-3-81-6-64.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.09 0.08 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=190/0-3-8, 4=92/0-1-8 Max Horz 2=36(LC 8) Max Uplift 2=-30(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T08 Truss Type Half Hip Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348350 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-G7aUekcPk4hUqmr0CTkgnFmcstNflje7v6uCDFyHZCm Scale = 1:22.4 1 2 3 4 7 6 5 8 9 10 6x6 6x6 3x6 2x4 3x6 3x6 7-10-127-10-12 10-3-82-4-12 -1-0-0 1-0-0 7-10-12 7-10-12 10-3-8 2-4-12 0-5-13-2-153-4-93-3-00-5-84.50 12 Plate Offsets (X,Y)-- [2:0-0-12,0-1-8], [6:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.52 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.27 0.01 (loc) 2-7 2-7 8 l/defl >999 >449 n/a L/d 240 180 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=476/0-3-8, 8=381/0-1-8 Max Horz 2=77(LC 9) Max Uplift 2=-13(LC 9), 8=-1(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-456/27, 4-6=-89/409 BOT CHORD 2-7=-62/347, 6-7=-71/336 WEBS 3-7=0/289, 3-6=-510/96, 4-8=-383/78 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-10-12, Exterior(2) 7-10-12 to 9-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T08A Truss Type Half Hip Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348351 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-G7aUekcPk4hUqmr0CTkgnFmfLtRplid7v6uCDFyHZCm Scale = 1:19.7 1 2 3 4 7 6 5 8 9 10 11 6x6 6x6 3x6 2x4 3x6 3x6 5-10-125-10-12 10-3-84-4-12 -1-0-0 1-0-0 5-10-12 5-10-12 10-3-8 4-4-12 0-5-12-5-152-7-102-6-00-5-84.50 12 Plate Offsets (X,Y)-- [6:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.28 0.31 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.09 0.01 (loc) 2-7 2-7 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=476/0-3-8, 8=381/0-1-8 Max Horz 2=60(LC 9) Max Uplift 2=-17(LC 9), 8=-9(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-604/70, 4-6=-24/271 BOT CHORD 2-7=-94/503, 6-7=-101/500 WEBS 3-6=-458/93, 4-8=-386/72 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-10-12, Exterior(2) 5-10-12 to 9-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss T09 Truss Type MONOPITCH Qty 8 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348352 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:37 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-G7aUekcPk4hUqmr0CTkgnFmectS1lmh7v6uCDFyHZCm Scale = 1:14.2 1 2 3 4 5 2x4 2x4 2x4 4-11-84-11-8 -1-0-0 1-0-0 4-10-0 4-10-0 4-11-8 0-1-8 0-5-12-3-61-11-140-3-82-3-64.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.33 0.24 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.03 -0.07 0.00 (loc) 2-4 2-4 4 l/defl >999 >788 n/a L/d 240 180 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=264/0-3-8, 4=178/0-1-8 Max Horz 2=57(LC 6) Max Uplift 2=-25(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 Pyatt Builders - 82 TG Job Reference (optional) I39348353 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:38 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-kJ8ss4d1VOqLRwQCmBGvKTJhCHfAU?WH8mellhyHZCl Scale = 1:54.1 1 2 3 4 5 9 8 7 61011121314151617 18 19 20 4x8 5x10 MT18HS 8x8 5x8 4x10 5x8 4x10 10x10 10x10 6-4-06-4-0 12-7-06-3-0 18-10-06-3-0 25-2-06-4-0 6-4-0 6-4-0 12-7-0 6-3-0 18-10-0 6-3-0 25-2-0 6-4-0 0-9-09-1-110-9-08.00 12 Plate Offsets (X,Y)-- [1:0-0-10,0-0-0], [1:0-4-3,0-1-15], [1:Edge,0-2-15], [5:Edge,0-2-15], [5:0-4-3,0-1-15], [5:0-0-10,0-0-0], [7:0-4-0,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.85 0.82 0.92 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.14 -0.31 0.08 (loc) 7-9 7-9 5 l/defl >999 >974 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 394 lb FT = 20% GRIP 169/123 244/190 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-7: 2x4 SPF No.2 WEDGE Left: 2x8 SP 2400F 2.0E, Right: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=9152/0-3-8, 5=10078/0-3-8 Max Horz 1=-139(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-13244/0, 2-3=-9041/0, 3-4=-9042/0, 4-5=-13496/0 BOT CHORD 1-9=0/10606, 7-9=0/10606, 6-7=0/10814, 5-6=0/10814 WEBS 3-7=0/9552, 4-7=-4208/0, 4-6=0/5063, 2-7=-3951/0, 2-9=0/4771 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1356 lb down at 2-0-12, 1356 lb down at 4-0-12, 1356 lb down at 6-0-12, 1463 lb down at 8-0-12, 1463 lb down at 10-0-12, 1463 lb down at 12-0-12, 1463 lb down at 14-0-12, 1463 lb down at 16-0-12, 1463 lb down at 18-0-12, 1463 lb down at 20-0-12, and 1463 lb down at 22-0-12, and 1464 lb down at 24-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Continued on page 2 November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss TG01 Truss Type COMMON GIRDER Qty 1 Ply 3 Pyatt Builders - 82 TG Job Reference (optional) I39348353 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:38 2019 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-kJ8ss4d1VOqLRwQCmBGvKTJhCHfAU?WH8mellhyHZCl LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 9=-1356(B) 10=-1356(B) 11=-1356(B) 12=-1463(B) 13=-1463(B) 14=-1463(B) 15=-1463(B) 16=-1463(B) 17=-1463(B) 18=-1463(B) 19=-1463(B) 20=-1464(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss TG03 Truss Type Common Girder Qty 1 Ply 2 Pyatt Builders - 82 TG Job Reference (optional) I39348354 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-CWiE3QefGhyC34?PKun8sgsubh2wDX5QNQNIH7yHZCk Scale = 1:41.4 1 2 3 6 5 47891011 12 13 14 5x8 5x12 5x8 6x8 3x12 3x12 6-9-26-9-2 10-10-144-1-12 17-8-06-9-2 8-10-0 8-10-0 17-8-0 8-10-0 0-9-06-7-110-9-08.00 12 Plate Offsets (X,Y)-- [1:0-1-12,0-2-8], [3:0-1-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.74 0.59 0.58 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.21 0.04 (loc) 3-4 3-4 3 l/defl >999 >982 n/a L/d 240 180 n/a PLATES MT20 Weight: 214 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=7484/0-3-8, 3=7083/0-3-8 Max Horz 1=-97(LC 15) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-8310/0, 2-3=-8340/0 BOT CHORD 1-6=0/6741, 4-6=0/5165, 3-4=0/6766 WEBS 2-4=0/4737, 2-6=0/4663 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-3-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1469 lb down at 0-6-12, 1463 lb down at 2-6-12, 1463 lb down at 4-6-12, 1463 lb down at 6-6-12, 1463 lb down at 8-6-12, 1463 lb down at 10-6-12, 1463 lb down at 12-6-12, and 1463 lb down at 14-6-12, and 1464 lb down at 16-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 6=-1463(F) 7=-1469(F) 8=-1463(F) 9=-1463(F) 10=-1463(F) 11=-1463(F) 12=-1463(F) 13=-1463(F) 14=-1464(F) November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V01 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348355 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:39 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-CWiE3QefGhyC34?PKun8sgs1sh9ZDdSQNQNIH7yHZCk Scale: 1/4"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 3x4 4x6 3x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 23-9-123-9-1 23-9-70-0-6 11-10-11 11-10-11 23-9-7 11-10-11 0-0-47-11-20-0-48.00 12 Plate Offsets (X,Y)-- [10:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.15 0.17 0.24 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 23-8-11. (lb) - Max Horz 1=-121(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 11, 12, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=428(LC 1), 11=415(LC 13), 12=317(LC 1), 9=415(LC 14), 8=317(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-260/107, 5-9=-260/107 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 11-10-11, Exterior(2) 11-10-11 to 14-10-11, Interior(1) 14-10-11 to 23-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 12, 9, 8. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V02 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348356 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:40 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-hiGcHmfH1?43hEabucINPuO965P7y5Lab47sqZyHZCj Scale = 1:40.1 1 2 3 4 5 9 8 7 6 10 11 12 13 14 153x4 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 0-0-60-0-6 19-9-719-9-1 9-10-11 9-10-11 19-9-7 9-10-11 0-0-46-7-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.37 0.47 0.13 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 59 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 19-8-11. (lb) - Max Horz 1=-100(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=368(LC 1), 9=528(LC 13), 6=528(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-346/136, 4-6=-343/135 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 9-10-11, Exterior(2) 9-10-11 to 12-10-11, Interior(1) 12-10-11 to 19-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V03 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348357 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-hiGcHmfH1?43hEabucINPuOCQ5V3y6pab47sqYyHZCj Scale: 3/8"=1' 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-60-0-6 15-9-715-9-1 7-10-11 7-10-11 15-9-7 7-10-11 0-0-45-3-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.16 0.09 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-8-11. (lb) - Max Horz 1=79(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=351(LC 13), 6=351(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-264/110, 4-6=-264/110 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 7-10-11, Exterior(2) 7-10-11 to 10-10-11, Interior(1) 10-10-11 to 15-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V04 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348358 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-9up?U6fvoJCwIO9nRJpcx5xIyUnahZ0jqksPM0yHZCi Scale = 1:24.8 1 2 3 4 5 6 7 8 3x8 4x8 3x8 2x4 0-0-60-0-6 11-9-711-9-1 5-10-11 5-10-11 11-9-7 5-10-11 0-0-43-11-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.50 0.33 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=213/11-8-11, 3=213/11-8-11, 4=440/11-8-11 Max Horz 1=-58(LC 7) Max Uplift 1=-9(LC 9), 3=-9(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-274/60 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 5-10-11, Exterior(2) 5-10-11 to 8-10-11, Interior(1) 8-10-11 to 11-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V05 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348359 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:41 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-9up?U6fvoJCwIO9nRJpcx5xJZUpghaxjqksPM0yHZCi Scale = 1:17.7 1 2 3 4 5 6 7 8 2x4 4x6 2x4 2x4 0-0-60-0-6 7-9-77-9-1 3-10-11 3-10-11 7-9-7 3-10-11 0-0-42-7-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.39 0.26 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=146/7-8-11, 3=146/7-8-11, 4=253/7-8-11 Max Horz 1=-36(LC 7) Max Uplift 1=-12(LC 9), 3=-12(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 3-10-11, Exterior(2) 3-10-11 to 6-10-11, Interior(1) 6-10-11 to 7-3-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V06 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348360 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-d4NNiSgXZcKnwXk_?1KrUJUZNuA3Q1ws3OcyuSyHZCh Scale = 1:9.0 1 2 3 2x4 3x4 2x4 3-9-13-9-1 3-9-70-0-6 1-10-11 1-10-11 3-9-7 1-10-11 0-0-41-3-20-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.18 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=113/3-8-11, 3=113/3-8-11 Max Horz 1=15(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V07 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348361 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:42 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-d4NNiSgXZcKnwXk_?1KrUJUQiu61Q?Ys3OcyuSyHZCh Scale = 1:28.1 1 2 3 4 5 6 3x8 4x8 3x8 2x4 0-0-60-0-6 13-6-713-6-1 6-9-3 6-9-3 13-6-7 6-9-3 0-0-44-6-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.69 0.44 0.15 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=247/13-5-11, 3=247/13-5-11, 4=511/13-5-11 Max Horz 1=-67(LC 7) Max Uplift 1=-11(LC 9), 3=-11(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-319/66 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 6-9-3, Exterior(2) 6-9-3 to 9-9-3, Interior(1) 9-9-3 to 13-0-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V08 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348362 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-5HxlvohAKwSeYhIAZkr41W0hNIVw9T70I2LWQuyHZCg Scale = 1:21.0 1 2 3 4 5 6 7 8 3x6 4x6 3x6 2x4 0-0-60-0-6 9-6-79-6-1 4-9-3 4-9-3 9-6-7 4-9-3 0-0-43-2-20-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-S 0.31 0.21 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=169/9-5-11, 3=169/9-5-11, 4=348/9-5-11 Max Horz 1=-46(LC 7) Max Uplift 1=-7(LC 9), 3=-7(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 4-9-3, Exterior(2) 4-9-3 to 7-9-3, Interior(1) 7-9-3 to 9-0-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. November 20,2019 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job TG-191 Truss V09 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 82 TG Job Reference (optional) I39348363 8.240 s Jul 14 2019 MiTek Industries, Inc. Tue Nov 19 16:46:43 2019 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-5HxlvohAKwSeYhIAZkr41W0jPIRr9UA0I2LWQuyHZCg Scale = 1:13.5 1 2 3 2x4 3x4 2x4 0-0-60-0-6 5-6-75-6-1 2-9-3 2-9-3 5-6-7 2-9-3 0-0-41-10-20-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.18 0.47 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=183/5-5-11, 3=183/5-5-11 Max Horz 1=24(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (all heights) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. November 20,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths