HomeMy WebLinkAboutGN010.0Indiana 2�2� Perfarman�e �ompliance
Praperty
528 ❑ICKS�N LN
CARM EL, I N 46280
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26
JG2fi1 (AS QESIGNEQ}
JACKSONS GRAhIT 2fi1
11D5
1102.4.1.2
11 D2.5
11 D2.5
11 D4.1
f�landatory Checklist
11 D3.6
11D3.B.1
❑rganixatian
TSI Energy Solutions
Matthew Timmons
Builder
OLD TOWN DESIGN
GRDUP
Annual Energy Cost
Design
Heating
Caoling
Water Heating
Mechanical Ventilatian
SubTotal - Used to determine �omplian�e
Lights & Appliances wlout Ventilation
�nsite generation
Total
Indiana 2020 Performance
$1,642
$244
$2a1
$�fi
$2,142
$990
$0
$3,132
Requirements
�
�
�
�
�
�
�
�
Performance-based compliance passes by 5.4°:0
Air Leakage Testing
Area-weighted average fenestration SHGC
Area-weighted a�erage fenestration U-Factor
Lighting Equipment Efficiency
hlandatory code requirements that are not
checked by Ekotrope must be met.
Mechanical Ventilation Rate
h�lechanical Ventilation Efficacy
Inspe�tion 5tatus
Results are projected
+ TS��nergyS�lutir�ns
As aesigned
$1,582
$231
$201
$13
$2,D26
$990
$0
$3,D17
Air sealing is 4.00 ACH at 50 Pa. It must not exceed 5.00 ACH at 54 Pa.
Design exceeds requirements fvr Indiana 202� Perfvrmance compliance hy 5.4°Io.
As a 3rd party extension of the code jurisdi�tion utilizing these reports, I certify that this energy code complian�e document has been created in accordan�e with the requirements of
Chapter 4 of the adopted Intemational Energy Conservation Code based on Climate Zone 5. If rating is Projected; I certiTy that the building design des�ribed herein is consistent with
the building plans, specifications, and other �al�ulations submitted �tiith the permit application. If rating is Confirmed, I �ertiTy that the address referenced abo�e has been
inspected.+tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
❑rganization
1�+latthew Timmons
TSI Energy 5olutions
5ignature:
Date: 2,'6i2fl at 3:37 PM
Ekotro�e RATER - Vers.on 3.2.2.235:
Indiana 202� Perforinance compliance results calculated using Ekotrope RATER's energ}� and code compliance algorithin, including appropriate amendments.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are 6ased on data entered 6y Ekotrope users.
Ekotrope disclaims all lia6ility for the information shown on this report.
��� a���son� �n�
Building Features
I �►►[•T Ca
Slab R-�.� Perimeter, R-0.0 Under
CARM E L, 1 N 4G28Q
6uilder: OLD T�WN DE51GN GR�UP
Duct Supply R-6.0, Return R-10.0
Ceiling Atti�, R-38
Aboae Grade Walls R-15
Foundation Walls R-14
Framed Floor NIA
linfiltration 4 ACH50
Window U-Value: 0.3, SHGC: 0.27
Duct Leakage to Outside 4 CFM251 10� ft2
Tatal auct Leakage 8 CFM251 10� ft2 (Post-Canstructiony
Heating Furnace • hlatural Gas • 92.1 AFIJE
Cooling Air Canditianer • Electri� • 13 SEER
Water Heating Water Heater • Natural Gas •�.64 Energy Factar
as a 3r� paity extei;sicn of t�e ��de jur,sd,c�,en Gt,lizii;g these repats, I cert,fy that �his zneryy cedz cc�ipliai;ce d�cu�iei:t �as been created in acceraance �rrith t�e reqGire��2i;ts of
Chapter 4 of the adopted International Energy Conservation Code dased on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent �tiith the
building plans: specifications. and other calculations submitted with the permit application. If rating is Confrmed: I certiTy that the address referenced above has been inspected.+tested and
that the mandatory provisions of the IECC hawe been installed to meet or exceed the intent ofthe IECC or vrill be verifed as such by another party.
Name: Matthew Timmons
Si�nature:
Organization: TSI Energy Salutions aate: 2f6J2� at 3:37 PM
Ekotrope RATER - Version 3.2.2.235'I
Irdiara 2C2ii Certiicate cam� wnce r�s.alts calculated using Ekotrope RATER's energy and code compliance algorithm. including appropriate ainendments.
E4;atrooe P..=.TER is a RESNETHcc-edited HERS Rat rg Tool. =.1 resul°s are based on data an:ered h, E4;otrope �sers.
-E:o�r��:e : a=1a -is all lial: :.: i� t a in-c ma:ic� a�o::n o� 1� a r=��c �.
Energy �ode Inspectian Checklist
Praperty
528 ❑ICKS�N LN
CARM EL, I N 46280
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26
JG2fi1 (AS QESIGNEQ}
JACKSONS GRAhIT 2fi1
�eneral Building Infvrmatian
Conditioned Area �sq ft}
Canditioned Volume (�ubic ft)
Insulated Shell Area (sq fty
❑rganixatian
TSI Energy Solutions
Matthew Timmons
Builder
OLD TOWN DESIGN
GRDUP
�,2��
49,18�
10,36Q
Inspe�tion 5tatus
Results are projected
+ TS��nergyS�lutir�ns
The building energy model in Ekotrope reflects the building assemhlies and energy features listed below. Sometimes errergy
features will �hange in the field from what has been modeled. The inspection pro�ess should identify any �hanges and ensure
that the home continues to meet the applicable energy code.
51ab
� Name: BSMT�1,975 s.f., 231 ft. exterior perimeter}
R-0 perimeter insulation, R-� under slab insulatian.
Framed Flvar
Nane Present
Fvundatian Wall
� Name: C�NDlAM6 �Exterior Perimeter [ft]: 12G, HeightAbove Grade [ft]: 1, aepth Below Grade [ft]: 8}
R-3.1 continuous insulation, R-11 cavity insulation
Insulati�n Grade: I
Feet from tap af wall to tap of insulation: 1, Feet from top of wall to bottom of insulatian: 8
� Name: C�NDlAM6 UNFIN (Exterior Perimeter [ft]: 51, HeightAbove Grade [ft]: 1, ❑epth 6elaw Grade [ft]: 8}
R: 13.10
Feet from top af wall t� tap of insulatian: 0, Feet fr�m top of wall to bottom of insulatian: 4
� Name: C�NDfGAR �Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth 6elow Grade [ft]: 8}
R-3.1 continuous insulation, R-11 cavity insulation
Insulation Grade: I
Feet from top af wall to tap of insulation: 1, Feet from top of wall to bottom of insulatian: 8
� Name: C�NDlGAR UNFIN (Exterior Perimeter [ft]: 23, HeightAbove Grade [ft]: 1, ❑epth 6elaw Grade [ft]: 8}
R: 13.10
Feet from top of wall to tap of insulatian: 0, Feet from top of wall to bottam of insulation: 4
Abvve �rade Wall
Energy �ode Inspectian Checklist
Property ❑rganixatian
528 ❑ICKS�N LN TSI Energy Solutions
CARMEL, IN 46280 Matthew Timmons
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26 Builder
OLD TOWN DESIGN
JG2fi1 (AS QESIGNEQ} GRDUP
JACKSONS GRAhIT 2fi1
� Name: C�NDlAM6 �2,481 s.f.}
R-0 continuous insulati�n, R-15 cavity insulatian
Insulati�n Grade: I
� Name: C4NDfGAR �54D s.f.y
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
� Name: C�NDlATTIC �870 s.f.}
R-0 continuous insulation, R-15 cavity insulatian
Insulation Grade: I
Rim Jaist
� Name: C�N DlAM 6� 177 s.f. }
R: 11.691
� Name: C�NDlGAR �54 s.f.y
R: 11.691
� Name: BANa C�NDIAM6 �37 s.f.y
R: 11.691
� Name: C�NDfATTIC �164 s.f.}
R: 11.691
Ravf
� Name: ATTIC (1,755 s.f.}
R-27.�5 continuaus insulation, R-1 D.15 �avity insulation
Insulation Grade: I
� Name: VAULT (228 s.f.}
R-0 continuous insulation, R-38 cavity insulatian
Insulation Grade: I
Dpaque Daar
Inspe�tion 5tatus
Results are projected
+ TS��nergyS�lutir�ns
2
Energy �ode Inspectian Checklist
Praperty
528 ❑ICKS�N LN
CARM EL, I N 46280
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26
JG2fi1 (AS QESIGNEQ}
JACKSONS GRAhIT 2fi1
� Name: FR�NT (48 s.f.}
U: 0.476
� Name: GARAGE (20 s.f.}
U: 0.182
�lazing
❑rganixatian
TSI Energy Solutions
Matthew Timmons
Builder
OLD TOWN DESIGN
GRDUP
Inspe�tion 5tatus
Results are projected
� Name: FRONT (101 s.f.}, Ll: D.30D, SHGC: 0.27, �rientatian: INEST
� Name: BAGK (60 s.f.}, U: 0.300, SHGC: 0.27, �rientation: EAST
� Name: SLIDER (96 s.f.), U: 0.300, SHGC: 0.27, Drientation: EAST
� Name: RIGHT �98 s.f.}, lJ: 0.3D0, SHGC: D.27, arientation: 5DL1TH
� Name: LEFT (30 s.f.}, Ll: D.3�0, SHGC: 0.27, �rientation: NORTH
� Name: BSMT RIGHT �27 s.f.}, U: 0.30D, SHGC: 0.27, Drientation: SOUTH
� Name: BSMT LEFT (16 s.f.}, U: 0.300, SHGC: 0.2�, Orientation: SOUTH
� Name: BSMT BACK (16 s.f.}, lJ: 0.300, SHGC: �.27, Drientation: EAST
5kylight
Nane Present
Mechanical Ventilativn
� Mechanical ventilatian system rated for, and capable of, praviding cantinuous ventilation.
System shall include autamatic timing controls.
System type: Exhaust �nly, 24 hrsJday, 151Natts
Mechanical Equiprnent
+ TS��nergyS�lutir�ns
3
� Furna�e • Natural Gas • 100°Io Heating Load a�? 92.1 AFUE
Energy �ode Inspectian Checklist
Property ❑rganixatian
528 ❑ICKS�N LN TSI Energy Solutions
CARMEL, IN 46280 Matthew Timmons
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26 Builder
OLD TOWN DESIGN
JG2fi1 (AS QESIGNEQ} GRDUP
JACKSONS GRAhIT 2fi1
� Air Canditioner • Ele�tric • 100°Io Caoling Load @ 13 SEER
Inspe�tion 5tatus
Results are projected
� Water Heater • Natural Gas • 100°Io Hot Water Load �7a 0.64 Energy Fa�tor
Air Leakage Cvntrvl
� Test Status: 6lawer-door tested
House is air-sealed as to achieve 3,279 CFM50 �4.00 ACH50J ar less at final blower-doar test.
Infiltratian Requirements for IECC in Climate Z�ne 5
2a09 IECC Infiltration limit for the design hame is 7 ACHS�.
2�12 IECC Infiltration limit fQr the design home is 3 ACHS�.
2a15 IECC Infiltration limit far the design home is 3 ACHS�.
2a18 IECC Infiltration limit for the design hame is 3 ACHS�.
Duct Leakage
Duct 5ystem 1
NOT entirely within �onditioned spa�e, testing required
Leakage to Outside spe�ified as: � CFM251 1 DD f#2
Total Leakage spe�ified as: 8 CFM251 1D� ft2 �Post-Constru�tion}
Duct Leakage Cvde Requirements fvr IECC
20fl9 IECC:
Pastconstruction Leakage Test: auct Leakage to Dutdoors �= 8 CFM251 100 sq ft CFA.
Rough in Test with AHU: Tatal auct Leakage �= 6 CFM251 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage �= 4 CFM25 1 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Tatal auct Leaka�e �= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total auct Leakage �= 4 CFM251 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage �= 3 CFM25 ! 100 sq ft CFA.
2Q15 Performance Path �Cost Campliance}:
+ TS��nergyS�lutir�ns
Leakage testing is required UNLESS all ducts and air handlers are lo�ated entirely within the thermal er#i�elope.
There is no passlfail threshold for duct leakage on the performance path.
Energy �ode Inspectian Checklist
Praperty
528 ❑ICKS�N LN
CARM EL, I N 46280
Madel: CAR�LL RESIDENCE
Cammunity: JACKSONS GRANT 26
JG2fi1 (AS QESIGNEQ}
JACKSONS GRAhIT 2fi1
Praject Nates
❑rganixatian
TSI Energy Solutions
Matthew Timmons
Builder
OLD TOWN DESIGN
GRDUP
Inspe�tion 5tatus
Results are projected
+ TS��nergyS�lutir�ns
5
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JA.CKSOfVS G4ANT 251
General Building Infarmation
Number Df Bedrecr�s
Number Of Floors
Conditioned FlaorArea [sq. ft.]
Unconditioned; atta�hed garage7
Conditioned Volume [�u. ft.]
Total Units in Building
Residence Type
Flaar Number
Madel
Cammunity
Climate Zone
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Inspectian Status
Results are proje�ted
�
4
2
5;245
Yes
49;184
1
5ingle family detached
CAROLL RESIDENCE
JACK50NS GRRNT 261
5A
r TSICner�,�S�l�atir�ns
Foundativn Wall
Name Library Type Height Above Grade Depth Below Grade
CaND.'APY96 OLD TaWN FINISHED 1 8
COND.+AP;1BlJNFIN DLD70VVN 1 8
UNFINISHED
CaND.'GAR OLD TaWN FINISHED 1 8
COND.+GARIJNFIN DLD701'VN 1 8
UNFINISHED
Perimeter
12G
51
31
23
Foundati�n Wall Library List
Name Feet From Wall Tap To Feet From Wall Top To Is Fully Insulated Continuous R•value
Continuouslnsulation Continuouslnsulation
Top Battam
❑L� TDU"JN FINISHED 1 8 No 3.1�
OLD TaWN 0 4 No N?A
11NFINISHED
51at}
Name Lihrary Type
BSh�1T Llninsulated
Locatian Enclosing
Exposed Exterior Conditioned Space
Exposed Exterior Conditioned Space
Exposed Exterior Conditioned Space
Exposed Exterior Conditioned Space
Cavity R-value Effective Insulation R•
�alue
11.00 N.+A
N.'A 13.10
Perimeter FloorGrade CarpetR Exposed SurtaceArea Location Enclosing
Masonry Area
231 BeloU: Grade D 0 1,975.D ft� Exposed Exterior Conditioned
Space
�
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JA.CKSONS GRANT 2fi1
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Slab Library List
Name Wall Construction 51ah Completel�+ LJnderslab Perimeter Perimeter Thermal Break Effective R-value
rype Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated �M1lood Frame ? Dther fVo 0 0 D No 6.00
Framed Flaor
Framed Flvar Library List
I Rim Jaist
Name
6AN� CaND.'Ah16
CaN D.'AF;16
Cd N D.`ATTI C
C a N D.� GAR
Rim Jaist Library List
Name
G1 R-15. DS6
None Present
Inspectian Status
Results are proje�ted
r TSICner�,�S�l�atir�ns
None Present
Lihrary Type
Surtace Area
Location
G1 R-15. DS6
G1 R-15. DS6
Gi R-15. dS6
G1 R-15. DS6
Effective Insulation R-value
11.591
37. � ft�
177. � ft�
164. � ft�
54. � ft�
Exposed Exterior
Exposed Exterior
Attic
Exposed Exterior
�
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JA.CKSONS GRANT 2fi1
� IIVa l l
Name
CaN D.'AF;16
CD N D.'ATTI C
CaN D.'GAR
Wal1 Library List
Name
G1 R-15 BATT. �S6
G1 R-15 GarVJalls
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Liqrary Type
G1 R-15 6ATT. a5B
G1 R-15 6ATT. a5B
G1 R-15Gar4^Jalls
�
13.423
11. 972
Inspectian Status
Results are proje�ted
5urface Colar
F�ledium
F�ledium
f�ledium
r TSICner�,�S�l�atir�ns
5urtace Area
Lacation
2,481.D f[� Exposed Exterior
870.D f[� Atti�
540.D f[� Unconditioned. attached garage
Glazing
Name Lihrary Type Wall Assignment Foundation Wall a�erhang Depth Dverhang Ft To Oyerhang Ft To Orientation Surface prea
Assignment Top Hottom
BRCK LI-.3�. SHGC-.27 COND.+AP;1B D � 0 East so.o n=
BSh;1T 6ACK lJ-.30. SHGC-.27 CONa+'Ah�1B D 0 0 East 16.0 ft�
BSh4T LEFT lJ-.3�. SHGC-.27 CDNa+AI�1B D � 0 South 16.� ft�
BSI�1T RIGHT lJ-.3�. SHGC-.27 CDNQ+Ah�1B D � 0 South z�.o n�
FRDNT lJ-.30. SHGC-.27 COND.+AI;1B D 0 0 4"Jest 1 D1.0 ft�
LEFT ll-.3�. SHGC-.27 COND.+AI;1B D � 0 North 30.� ft�
RIGHT ll-.3�. SHGC-.27 COND.+AP;1B D � 0 South 98.� ft�
SLIDER ll-.3�. SHGC-.27 COND.+AP;1B D � 0 East 96.� ft�
Effective R-value
�
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JACKSONS G4ANT 2fi1
Glazing Library List
Name
ll-.3D. SHGC-.27
Skylight
5kylight Library List
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Shgc
D.27
None Present
None Present
Dpaque Davr
Name Library l]rpe Wall Assignment Foundatian Wall
Assignment
FRDNT 4"Joad Door COND.+AIr9B
GARAGE Fiberglass+'Steel COND.+GAR
Door
�paque D�vr Library List
Name
Fiberglass.+Steel Door
4"Joad Door
Effective L!-factor
�.182
�.476
Inspectian Status
Results are proje�ted
L!-factor
�. 300
r TSICner�,�S�l�atir�ns
Emittance Solar SurtaceColor SurtaceArea Lacatian
Aqsorptance
0.9 0.75 1;ledium 48.6 ft� Exposed Exterior
0.9 0.75 P;ledium 20.6 ft� Exposed Exterior
�
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JACKSC?fV5 G4ANT 2fi1
Ravf Insulation
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Inspectian Status
Results are proje�ted
Name Liqrary Type Attic ExteriorArea [s.f.] Clay or Concrete Raof
Tiles
ATTIC R-38 Blo�tin. GR1 1.755 No
VALILT R-38 Vaulted. GR1 228 No
Ravf Insulatian Lihrary List
Name Has Radiant Barrier
R-38 Blown. GR1 Na
R-38 Vaulted. GR1 No
Whale House Infiltrativn
Infiltration Measuremant Type
4 ACH at 50 Pa Blower�oor tested
Mechanical Ventilation
Ventilation rype Ventilation Rate [ft" f Dperational hours per day
Minute]
Exhaust Only 105 CFI�1 24
Effective R-value
38.268
32.263
Shelter Class
4
�
r TSICner�,�S�l�atir�ns
5urtace Color Surtace Area
F;ledium 1.755.�f[�
F;ledium 2�s.on=
Lacation
Atti�
Vaulted Roof
Fan Watts Runs once every three Energy Recovery Percent
hours
15'�"Jatts No 0
Lighting
Io Interior Fiuorescent =�� Interior LED Lighting `.: Exterior Fluorescent °o Exterior LE� Lighting °� Garage Fiuorescent =�� Garage LED Lighting
Lighting Lighting Lighting
90 Q 9D � 90 0
�
Building 5ummary
Property Organ ization
528 aICKSON LN TSI Energy Solutians
CARI,�EL. IN 45280 I,�atthewTimmons
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261 Builder
DLD T01`VN aESIGN GRaUP
JG2S1 �AS aESIGNE�}
JA.CKSOfVS G4ANT 251
Onsite Generation
None Present
�nsite Generation Library List '
None Present
Solar Generativn � '
None Present
5olar Generativn Library List
None Present
C�nditioning Equipment
Name Liqrary Type
Ai r Con d iti o ner
Furna�e
VJater Heater
CAI3NAOA8
9125A48�86517
RG1PV54S'N
Inspectian Status
Results are proje�ted
r TSICner�,�S�l�atir�ns
Heating Percent Load Cooling Percent Load Hot Water Percent Load
0°a
100°a
Q °Io
1 DO°I
0%
�°Io
�91�
�°io
10D°io
�quiprnent Type: 9125A4808�S17
Fuel Ty;�e Natural Gas
Distri�utian Type Farced Air
MatorType PSG {Single Speed}
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtu.�h] 78
Use default EAE No
EAE [kWh] 977
Location
Conditioned Space
Conditioned Space
Conditioned Space
�
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
JG2S1 �AS aESIGNE�}
JA.CKSOfVS G4ANT 2fi1
Equiprnent Type: CAI3NAD48
Fuel Ty;�e
Disiri�utian Type
Mator Type
Caaling Efficien�y
Cooling Gapa�ity [kBtu.�h]
Inspectian Status
Results are proje�ted
�
Electri�
Farced Air
PSC {Single Speed}
13 SEER
45.5
Equiprnent Type: R�1PV5flS*N
Fuel Ty;�e
Distributian Type
Hot Water Efficien�y
Tank Capacity {gal.}
Hot Water Capa�ity [kBtu,'h]
Recavery Efficiency
Natural Gas
Hydranic Delivery
0.64 Ener�y Factar
5a
4�
0.86
r TSICner�,�S�l�atir�ns
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JA.CKSOfVS G4ANT 251
�istribution System
Distributian Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply DuctArea [ftz]
Return �uct Area [ftz]
Leakage ta Outdaars
TotalLeakage
Total Leakage Duct Test Gonditions
Use Default Flaw Rate
Duct 1
Duct Lacation
Percent Supply Area
Percent ReturnArea
Duct 2
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Duct 3
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Duct 4
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Duct 5
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Duct 6
Duct Lacation
Percent 5upply Rrea
Percent ReturnArea
Ceiling Fan
Has Ceilino Fan
Cfm Per 4`L`att
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Inspectian Status
Results are proje�ted
�
Farced Air
Furnace
Air Conditianer
5245
�
�
�o
1416.15
131125
4 CFI�125 .+' 10� ftz
419.fi GFf4125
Post-Ganstruction
Yes
Conditianed 5pace
50
5C1
Attic {well vented; under insulation}
5�
5a
Conditianed 5pace
0
4
Conditianed 5pace
0
❑
Conditianed 5pace
4
0
Conditianed 5pace
0
0
No
r TSICner�,�S�l�atir�ns
Building 5ummary
Property
528 QICKSON LN
CARI�IEL. IN 45280
h9odel: CARDLL RESIDENCE
Communitv: JACKSaNS GRANT 261
JG2S1 �AS aESIGNE�}
JA.CKSOfVS G4ANT 251
'Water Distriputian
Organ ization
TSI Energy Solutians
I,�atthew Timmons
Builder
DLD T01`VN aESIGN GRaUP
Inspectian Status
Results are proje�ted
�
Water Fixture Type 5tandard
Use Default Nct'�ti'ater Piae Length No
Hot Water Pipe Length [ft] �L3
At Least R3 Pipe Insulatian7 No
Hot Water Recirculation System7 No
Recirculation System Pipe Loop Length [ft] 17�
Drain Water Heat Re�overy? No
Clvthes Dryer �
Fuel Tyae
Gef
Field Utilization
Clvthes Washer
Electric
Timer Contrals
�Label E; ie; �, ,�ati, ��: ?��4 k'��rh Year
Electric Rate 5�7.68�kWh
Annual Gas Gost 523.4fl
Gas Rate 5�.58rTherm
Capacity 2.874
Imef 0.33053
Appliances and �antrals
Programr�a�le thermastat? Yes
Dishwasher Size 5tandard
Dishwasher Efficiency 27� kWh
Range'Duen Fuel Natural Gas
Canvectian Dven7 No
Ilnductian Range? No
ReYeigeratar Consumption 709 kWhlYear
N�tes
r TSICner�,�S�l�atir�ns
9