Loading...
HomeMy WebLinkAboutE100_0rmsfiie wesa��� o� nuiwis� e o�aenM m� i��zoy�san� LOAD SUMMARY EpuiOmenl(Panel� PanelBusl Ex191n9 �4 Rnnov�LmJ PJJ N WeJ FlneIWeJ Fusewere cana veeeeM r�na�wzernmosi NyAP �kVP� �k/PI �kVP� �k/!Q *o*nuonosirvn)�. on os os o0 EwsungServi�'. V,PH,W 2/11680V,9PH,dW memeemnceisemmesne�. �qmps) e000 eesune oenana�. Ikvn) 53s.1 EoryingPaak�aman6 �kVA) 535.1 iolalRemovetl LoaB. �kVA) 0.5 ra�inaaeamaa�. �kvn) os i2nNoimerLoaB. �kVA) 538.1 ian9oimerLoatl�. �qmps) 644B "iHE COMPLEiE BOILDING LOAD AMPS �fi44H Amps) IS LESS iHAN iHE MAIN OVERCORRENi PROiECiION OF iHE EXISiING SERVICE DISGONNEGi SWIiGH pppp Amps�. EXISiING ELEGiRIG SERJIGE WILL REMAIN". ELECTRICAL REQUIREMENTS - CONNECTION SCHEDULE e�� U mQ — � � ZZ �m > O O �pw �w � � Z Z VZ U �� Qw � V � ED 1 SWILTI2HX NEW 1�CASECONN. � � (1)IX12H,(1)IX12G,(1)IX12N DETAIVF' 2 SWILTEHH NEW - - - - 1-0ASECONN. DC,DT,SS,TS - (i)k12H,(i)k12G(i)k12N DETAIL'F' q. IN GENERAL, RECEPTACLES SHOWN WITHOOT Ep01PMENT MARKING OR OTHER CALLOOT ARE CONVENIENCE OOTLETS THAT SHALL BE MOONTED AT 18" AFF. B. REFERTOREFRIGERATIONDEFROSTWIRINGCHARTFORMOREINFORMATION. � PROVI�ETHEFOLLOWINGMINIMUMWIRES¢ETOTHERRSTOUTLET(�EVICE)OFA150R20AMPBRANCHCIRCUIT. PROVI�EMINIMUMIXIOAWGTOTHELASTOUTLETFORALLBRANCH CIRCUITS MORE THAN 200 FEET W LENGTH. DISTANCE AWG WIRE SIZES UP TO 50 FEET IX12 MIN 50 T0200 FEET IX10 MIN � 200 FEET p8 MIN m�sn e ras creaee o� nzsizm s� ens ae nu� iaieazo��sazs ELECTRICAL REQUIREMENTS - NEW EQUIPMENT ¢rv. NnMe srnrus oescaiarioN veNooa Mooe� 1 9WILT12HH NEW �BOWFORFANS&A.S.HTRS,4800W(208V,1PH)FORELECDEF(ROOTECONDOITTOMECHCENTERORPROTOCOL H099MANN FW(LT) UNIT FOR CONTROL CKT & DEFROST WIRINGJ ON 12' WIDE ISLAND GROCERV CASE QCE CREAM TEMPJ 2 SWILTEH% NEW BBWFORFANS&A.S.HTRS,1360W(208V,iPH)FORELEGDEF(ROUTEGONDUITTOMEGHGENTERORPROTOGOL HUSSMANN FWE(L� UNIT FOR CONTROL CKT & �EFROST WIRING) ON WI�E ISLAN� GROCERY CASE EN� KEY NOTES L EXISTINGE�UIPMENTSHALLBEDEMOLISHED. EXISTINGFANCIRCUITSHALLBEREUSEDFORNEWWORK. 2 REUSEEXISTINGCIRCUITAN�EXTEN�ASREpUIRE�TOPOWERNEWEpUIPMENL FlEL�VERIFVEXISTINGCIRCUITSHAVESPARECAPACIN TO ACCOMMODATE THESE LOADS PRIOR TO ROUGH IN. PROVIDE BREAKERS IF NECESSARV SPARES ARE NOT AVAILABLE. 9. PROVIDE60A2FOLEBREAKERWITH(2)pBHAND(1)pBGFORNEWDEFROSTCIRCUITSTIEINTOENISTINGREFRIGERATIONSVSTEM. COORDINATE INSTALLATION WITH PROJECTMANAGER. ELECTRICAL SYMBOLS I _ I � �._� �. I � � i L� t —�--- 1 r — — 7 T — — � �� � � �I �� � � �I I� � � �I I� � � �I I� � � �I I� � � �I I� fl � � �I II � I I g II II I I u II O II I I II � I� � � �I I� � � �I �� � � �I �� � � �I ��e � � a�l 1 L � — _ _ _ _ _ JI I II II II II r� � ---�—�i ELECTRICAL PARTIAL , POWER DEMOLITION PLAN E1.1 SCALE�. 1/4"=1'-0" N MISCELLANEOUS LV3 LIGHTWG/POWERHOMERUNWITHPANELBOARDANDCIRCUITCALLOUT UN�ERGROUN� CIRCUIT WORK ANNOTATION XX DRAWING NOTE.MM=DRAWING NOTE DESIGNATION POWER � DUPLEM RECEPTACLE.MOUNTEDIB"AFFUNLESS OTHERWISE NOTED � �UAD RECEPTACLE,MOUNTEDIB"AFFUNLE55 OTHERWISE NOTED OOOO CEILINGMOUNTEDDUPLEMRECEPTACLE � FLOOR MOUNTED.THREE PHASE SPECIALRECEPTACLE � WALLMOUNTED.THREE PHASE SPECIALRECEPTACLE.MTD.18"AFF UNLE55 OTHERWISE NOTED � FLOORMOUNTED.SINGLEPHASESPECIALRECEPTACLE � WALLMOUNTED,SINGLE PHASE SPECIALRECEPTACLE,MTD18"AFF UNLE55 OTHERWISE NOTED y� DISCONNECT-FUSED ❑� DISCONNECT-NO&FUSED PLUGMOLD 0 �uNcnoNeox i SURFACE MOUNT ELECTRICALPANEL,ASINDICATED ON PLANSAND SCHEDULES � RECESSEDMOUNTELECTRICALPANELASINDICATEDONPLANSANDSCHEDULES GE38� DUPLEXRECEPTACLE.OWNERTAG/IDOFEpUIPMENTSERVED $� CASECONNECTION ABBREVIATIONS n nNnswenT cFa cRouNOFnu�TciRcuiTiNTeRRuaTeR AFF ABOVEFINISHEDFLOOR GFI GROVNDFAULTCIRCVITINTERRUPTER AHJ AUTHORITVHAVINGJURISDICTION GND GROUND AIC AMPEREINTERRUPTWGCAPACIiV L LIGHT ATS AUTOMATIC TRANSFER SWITCH MCB MAIN CIRCUITBREAKER BEC BUIL�ING ELECTRICALCONTRACTOR MLO MAINLUG ONLV C CONDUIT NEC NATIONALELECTRICALCODE CT CURRENTTRANSFORMER PNL PANELBOARD EM EMERGENCV (RJ EXISTING RELOCATED (E) EXISTINGTOREMAIN ST SHUNTTRIP E% E%ISTING TVP TVPICAL F FAN WP WEATHERPROOF FEC FIMUREELECTRICALCONTRACTOR MATERIAL AN� WORKMANSHIP SHALL COMPLV WITH THE FOLLOWING'. 2016 NATIONALELECTRICALCODE. 201] OHIO BUILDING CODE INCLUDING REFERENCED CODES AND STANDARDS. MATERIALS SHALL BE LISTED FOR INTENT OF USE. MATERIALS SHALL BE NEW UNLESS NOTE� OTHERWISE ON THE �RAWINGS. RELEASED FOR CONSTRl1CTI�N Su6ject ta compliance with all regulatlons of State and Local Codes City of Cannel �� n ;;,'�:,..,�zv.a>,.� oarE: 06/05/19 cOrvrvEcilOry POlrvi FOk CPSEANiI-SWEAiHEAiERS. CONNECiION POIM PoR �CNSELIGHiS. CONNECiION POIM FOR � CASE FANS. JUNCiION BO%MOUME� IN FlNISHED FLOOR BY B.EL. (4) GE63G24 (N) v�i � � I � � �, �� t t swi�risr�x RPCK 3, CIRCUR P h 0 ..���� — _ s a _ ELECTRICAL PARTIAL � POWER PLAN m E1.1 SCALE'. 1/4"=1'-0" N � � � .. (��\° � � + i i + JUNCiION BO% MOUNiEDIN WPLL 81"P.F.F., HORIZONiPLLY CENiERED ON "iIC"BY B.E.C. 0 i-in°coNouiraourEo ` AeovE caouNo coNouir allo �— corvrvEc.iory voirv.FOR uNOEacaouNorosouacE cor�ouc*oasFuaNisnEonr�o cnsEFnrvs. PANELBOARDBYBEC. INSiALLE�BYFIXiURE CONNECilONP01MPoR CONiRACiOR. CASELIGHiS. GONNECiION POIM PoR CASEANiLSWEAiHEAiERS. MECHANICAL HOUSE SYSTEM coNNEc*ioN aoiN* Foa cnsE oEFaos*. cor�r�Ec*ior� aoir�* Foa cnsE nN*i. swEn* xEn.Eas. coNNEc*iory aoirv.FOR �uNc*ioN earn�ouN*EoiN � �cnseucn.s. �wnu.evn.F.F.,HoaaoN.nuvi ceN.eaeo (CONNECilONP01NiFOR ON"iIC"�BYB.6C. / CPSEFANS. . . i-vz�coNouiraourEai �aeovEcaouNocoNoui*nNo /���coNNEc*ioNaoiN*FOR uNOEa�aouNorosouacE coNoucroasFuaNisHEonNo / cnsEFnNs. PANELBOARDBYBEC. INSiALLE�BYFIXiURE � CONNECilONP01NiPoR CONiRACiOR. / CNSELIGHiS. CONNECiION POIMPoR J CONNECiION POIMPoR CASEDEFROSi. CASEANiI-SWEAiHEAiERS. PROTOCOL / IPAC SYSTEM NOiP.FA�E�"iIC'MARK6 6HOWN WIiHIN iHE PoOiPRINi OFA REFRIGERAiE�GA6EIN�IGAiEROUGH�INI6iUB�UPLOGAilONS.WHEN LOOKING Ai iHE CASE FROM iHE FRONi, MARKS i0 iHE LEFi WIiHIN iHE CASE IN�ICAiE ELECiRIC LOCAilONS. PROVI�E WIRING BEiWEEN CONNECiION POINiS AS SHOWN. PROVI�E 1-0IP"CON�UIi AN� WIRE BACK i0 CASE FANS, LIGHiS, AN� ANiI�SWEAi SOURCE PANELBOPRDMIIREWAY FROM JUNCiION BO%OF CASES WIiH HOMERUN PRROWS i01NDICPiED CIRCUIi. NOiE�. FEC IS FESPONSIBLE FOR ALL NEC FEpNFE� LOCAL �ISW NNECiING MEANS �NOi FURNISHE� WIiH EpUIPMENi OR BV KFOGEF) FOR P COMPLEiE INSWLLAiION. PROVI�E PLL �ISCONNECiING MEPNS PER NEC J4491. � I I � �� l ■� vQ�/. :' U Z r 0 r J o � m Q� Z \ � / a� � Q � J U�/� � N LL p � O � z � ZZ W �� U S N N � LL ('7 Z LL.I M �, (� � ^ O 0 � � Y iss�eo on*e 51EEi iliLE ELECTRICAL POWER a PLAN rc z � SC/LLE COMM.NO. W 0 H0640 �RAWrvBY �AiE �,,,,�o,s — s�ee.a E1.1 0 THIS DRAWING IS PART OF A SET