HomeMy WebLinkAboutP100_02
�
PROPOSED PARTIAL
� PLUMBING DIMENSION PLAN m
Pt.t SCALE'. 3/18'•=1'_0'• N
RELEASED FOR CONSTRl1CTI�N
Su6ject ta compliance with all regulatlons
of State and Local Codes
City of Cannel
�
$�Y,����x�.��
�
oarE: 06/05/19
�
�
�----
aooa
GENERALNOTES:
1. SLOPEFLOOPIDFLOOPOPAINASINOICAiEOONCONCPEiEPIACEMENiPLNJ.
2. REFERi06WL01NG5VECIFlCNilONSECilON2213��FORPVVROVEOVIVINGMPiERIqL.
9. PEFEPiOPWMBINGPIANFOPLOGilON5PNO51ZE50FOPAWSANOPIPING.
4. iWIGLLVI'BUiPREFERABLVt2'IFFERMIiiE�BVLOGLPWMBWGWSPECi0Ri0
Fnnurnre mrvoervsnre oenw wsruwnoN.
ORiGwn� i66UE �niE sis0i06
NOiE
1
NoiE
3
�I��
PLUMBING
� WASTE AND VENT ISOMETRIC PLAN
P��� SCALE�. N.T.S.
PROPOSED PARTIAL
� PLUMBING FLOOR PLAN �
P1.1 SCALE'. 3/18"=1'-0" N
�`/
i4P]:i9J-
REMOVE THIS PORTION OF
HUB DRAIN TO BE CAPPED
AN�ABAN�ONE�
��
o e I x l'
�: e „
4"PVC
SCHEDULE
a0 PIPE —
0'.'P' TRAP
PATCH FLOOR FLUSH WITH
CONCRETE ARER HUB DRAIN
IS REMOVE�
CORE DRILL SAWCUT
�AROUND EXISTWG CO
ANDIOR FD TO BE REMOVED
0
f . o e ° .
ie
������������������\����
j��j��j��j� �
\ \�%\��j/�
��\\/�
� CAPDRAINBELON�SLAB
%
��%�� /�.
� — — — — O _
r�—�r_�1
� �� (I� � (
� �� I� �(
�---��r—ri--m----------E«Fo � — ��
II II II ' I
I II II
II glll II �
I I I �JI O
II I I II
II I I II
II I I II
II, I I ,II
�-L1�-� o ❑
ii 0 n
�L � = J� ❑
�
�
PLUMBING PARTIAL
� DEMOLITION FLOOR PLAN m
Pt.t SCALE'. 3/18'•=1'_0'• N
DEMOLITION GENERAL NOTES
A) COORDINATEALLREMOVEDPWMBINGFI%TURESWITHG.CANDKROGER
ENGINEER FOR IN STORE RELOCATION OR FUTURE KROGER USE.
B) ALLPLUMBINGPIPINGINWORKAREATHATISFOUNDTONOLONGERSERVE
ANV PURPOSE SHALL BE REMOVED AND CAPPED BEVOND RNISH SURFACE.
C) ATALL LOCATIONS WHERE PLUMBING RXTURESARE TO BE REMOVED. AND
THE PIPING SHALL NOT BE REUSED. PLUMBING CONTRACTOR SHALL REMOVE
PIPING (WATER. WASTE. VENT) TO A POINT BEYOND FINISH SURFACE AND
CAP. WHERE PIPING SERVING EXISTING FlXTURE TO BE REMOVED ALSO
SERVES FIXTURES THAT ARE TO REMAIN. PIPING SHALL BE REROUTED AND
RECONNECTE�ASREpUIRE�TOACCOMMO�ATEREMO�ELE�AREA5A5
REQUIRED.
D) WHEREE%ISTINGWALLSAREREMOVEDANDPIPINGISFOUNDTHATMUST
REMAIN, PLUMBING SUBCONTRACTOR SHALL REROUTE AND RECONNECT
PIPING AS RE�UIRED. EG. DOMESTIC WATER PIPINfi. GA$ SOIL. WASTE.
VENL. AN� ROOF LEA�ER PIPING.
NEW WORK GENERAL NOTES
A) VERIFYEXISTINGCONDITIONSRELATIVEIDEXTENTRE�UIREDFORNEW
WORK.
BJ COORDINATEWORKWITHALLDISCIPLINESINCLUDINGBUTNOTLIMITEDTO
OWNER'S FI%TURESAN� �ECOR. REFRIGERATION. FIRE PROTECTION
PLUMBING MECHANICAL, ELECTRICAL AND TELECOMMUNICATIONS, PRIOR TO
ANVINSTALLATION.
C) COORDINATEALLWORKWITHPHASINGPLANBE�UENCES.
D) PIPINGROUTEDINCOOLERORFREEZERWALLSWILLNOTBEPERMITfED.
E) NMENPOSSIBLELOCATEQEANOUTS.SOASNOTIDFALLINDOOR
OPENING$ UN�ER PALLET RACK$ OR IN MAIN TRAFRC AISLES.
F) WATERPIPINGINAREASSUBJECTIDFREEZINGTEMPERATURESWILLNOTBE
PERMITfED.
GJ ALLGAS,WATER.ANDSPRINKLERLWESINSIDEBUILDINGTOBEINSTALLED
AS HIGH AS POSSIBLE.
H) MAKEFINALCONNECTIONTOKROGERSUPPLIE�EpUIPMENT.
I) BRANCHISOLATIONVALVESTOBEMOUMEDATIO'-fi"AFFUNLESSUNABLE.
IN WHICH CASE MOUNT AS CLOSE TO 10'-6" A.F.F. AS POSSIBLE. HIDE FROM
PUBLIC VIEW, AN� MAKE ACCESSIBLE FOR MAINTENANCE.
JJ WHEREVERPOSSIBLE,NEWPIPINGANDRELOCATEDPIPINGSHALLBE
CONCEALED. COORDINATELOCATIONOFALLPIPINGWITHHVACAND
ELECTRIC SUBCONTRACTOR.
K) ALLPIPEDROPSINSALESAREAFROMRWFIDEpUIPMENTORHALFHEIGHT
WALLS SHOUL� BE COOR�INATE� AN� GROUP TOGETHER WITH OTHER
MECHANICALPIPES.
LJ DROPWATERDOWNINWALLROUTEWATERTHRUWALLTOSERVEMULTIPLE
FlXTURES ON THE SAME COMMON WALL.
M) PIPINGTOSERVICEAREASSHALLBEINSTALLE�INFRAME�WALLONWARM
SIDE OF INSULATED WALL PANELS USED FOR PREP ROOM N�ALLS. INSTALL
SHORTEST �ISTANCE TO EpUIPMENT. GROUP INSUTATE� LINES TOGETHER
WHERE E%POSED IN SALES AREA FOR ALL LINES AT BOTTOM OF BAR JOISTS.
N) WHEREVERFI%TURESREQUIRINGPWMBINGCONNECTIONSAREFURNISHED
BY OWNER OR ARE RELOCATE�, PLUMBING SUBCONTRACTOR SHALL FURNISH
AND INSTALL CARRIERS. "P"TRAP AND STOPS.
O) SURFACEMOUMEDWATERORVENTPIPINGSHALLNOTBEEXPOSEDINPREP
ROOMS.
P) PROVIDEBACKFLOWPROTECTIONONALLRXTURESWITHTHEPOTENTIALTO
MI%. FOR E%AMPLE MOP SINK FAUCET SUPPLY. 3 COMPARTMENT SINK FAUCET
SUPPLY, ICE MAKER, COFFEE MAKER, �RINKING MACHINE, ETC.
aJ FORALLFI%TURESTHATREQUIREWATERFlLTERS,MOUNTFlLTERUNITSNOT
HIGHER THAN 6'�4" ABOVE FLOOR AND LOCATE OUT OF PUBLIC VIEW AND
EASV ACCESS FOR MAIMENANCE.
R) PROVIDEANDINSTALLABENTMETALPLATEAROUNDANVPIPINGTHAT
COUL� BE E%POSE� TO �AMAGE. COOR�INATE LOCATIONS WITH KROGER PM
VERIFICATION NOTE:
CONTRACTOR SHALL VERIFV EXISTWG CONDITIONS. DIMENSIONS 8 QEARANCES
BEFORESTARTINGCONSTRUCTION. COMMENCEMENTOFWORKCONSTITUTES
ACCEPTANCE OF CONDITIONS.
SHOULD DIFFERING CONDITIONS BE ENCOUNTERED. CONTACT KROGER
REPRESENTATNE AND ARCHITECT BEFORE PROCEEDING WITH WORK.
CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS FOR ALTERNATE SANITARV
CONNECTIONS THAT ARE EITHER CLOSER TO THE AREA OF WORK OR LESS
INTRUSIVE TO THE OPERATION OF THE STORE �URING CONSTRUCTION. REPORT
ANY FOUND CONDITIONS TO THE OWNER AND ARCHITECT PRIOR TO ANY SLAB
CUTfING
PLAN KEYNOTES (�
1. REMOVEDRAIR.CUTANDCAPPIPEFORFUTURECLEANOUT.REFERTO
�ETAI V P�0'
2. WHENCASESAREREMOVE�.REMOVEANYA��ITIONALHUB�RAINSTHAT
ARE FOUND UNDER THE REMOVED CASES. CUT AND CAP PIPE FOR FUTURE
QEANOUT AS RE�UIRED. REFER TO DETAIL'P-4'
3. TIETHEDRAINFROMTHISCASEINTOTHEHUBDRAINOFASIMILAR
ADJACENT CASE ABOVE THE SLAB
4. CONNECTNEWSANITARVPIPINGIDEXISTINGPIPING. PLUMBING
CONTRACTOR SHALL VERIFV EXACT LOCATION. INVERT DEPTH AND
DIRECTION OF FLOW OF E%ISTING PIPING PRIOR TO ANY SAW CUTTING AND
INSTALLATION OF ANV PIPING.
�
l�ro�er � �
z
n O
r
Q1 ? >
r W —
� J Q
J
Q m J
U�/� �
L.L ❑ �
O � z
ZZ W
�� U
_ �
(� Z w(n
� � V
� ^ O
0
� �
Y
issveo oa�
sHEErnnE
PLUMBING ;
FLOOR PLAN &
AND DETAILS ;
�
SCPLE COMM.NO. �
e-iosae
oaawNev oa�
mww oainizme
SHEETp
P1.1 0
THIS DRAW ING IS PART OF A SET
Y
— — ex.
—�--