HomeMy WebLinkAboutMichelle Bell Plan setRECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46) Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 PV-1 PV-1 PROJECT INFORMATION PV-1A SITE PLAN, HOUSE PHOTO PV-2 ROOF PLAN PV-2A ATTACHMENT DETAILS PV-3 ELECTRICAL LINE DIAGRAM PV-3A ELECTRICAL NOTES, LOAD CALCS PV-4 REQUIRED SIGNAGE PROJECT INFORMATION VICINITY MAPPLAN SET LEGEND SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR LOAD CENTER INVERTER SUB AC DC SLC INV JUNCTION BOXJB COMBINER BOX CB ABBREVIATIONS EXTERIOR INTERIOR EXT INT NEW(N) EXISTING(E) ELECTRICAL METALLIC TUBINGEMT RIGID METALLIC TUBINGRMT VOLTAGE OPEN CIRCUITVOC VOLTAGE AT MAX. POWERVMP SHORT CIRCUIT CURRENTISC CURRENT AT MAX. POWERIMP MONITORING METERM NOT TO SCALENTS OCCUPANCY: R-3 CONSTRUCTION TYPE: VB UNSPRINKLERED MAIN SERVICE PANELMSP DEVICERS RAPID SHUTDOWN DATE: PROJECT INFORMATION N PROJECT SITE AHJ NOTES SHEET INDEXAPPLICABLE CODES PROJECT INFO 24 X 310 W MISSION SOLAR MSE310SQ8K ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 1 X 7600 W Solaredge SE7600H-US (240V) (SI1) 24 X 320 W Solaredge P-320 Power Optimizer SYSTEM SIZE: 7.440 kW DC STC ARRAY AREA: 430 SF AHJ: INDIANAPOLIS APN: 290-925-102-037-000-018 MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 11/21/2019 ALL CONDUIT TO RUN ON EXTERIOR OF HOUSE UNLESS OTHERWISE NOTED ALL WORK TO COMPLY WITH THE FOLLOWING CODES: 2014 NEC 2014 INDIANA BUILDING CODE 2014 INDIANA MECHANICAL CODE 2012 INDIANA PLUMBING CODE 2014 INDIANA FIRE CODE 03/18/20 David Rutti Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46) MSP SIZE IS AN TOTAL # OF PANELS PL (E) POOL DRIVEWAY MSP LOCATED AT EACH PANEL OPTIMIZER PV-1A HOUSE PHOTO DATE: SITE PLAN, HOUSE PHOTO SCALE: N.T.S. ARRAY LOCATION SCALE: 1":20'-0" SITE PLAN N (E) 200 A 24 THORNHURST DR 24 SOLAR MODULES 11/21/2019 (E) ONE -STORY HOUSE RAPID SHUTDOWN LOCATION 142'-0"113'-6"158'-6"93'-3"32'- 1 1" PL PL PL PL (E) DETACHED GARAGE M (E) MAIN SERVICE PANEL INSIDE BASEMENT (E) UTILITY METER INV (N) INVERTER TO BE LOCATED INSIDE BASEMENT 1 256'-1"19'-0"21'-10"10'-6"10'-10" 28'-3" 1 1 1 1 1 1 1 1 1 1 122 22 2 22222203/18/20 David Rutti Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46) SCALE: 1":10'-0" ROOF PLAN MSP SIZE IS AN ATTACHMENT POINTS:R1R2M JBARRAY 1 10 SOLAR MODULES 36 ATTACHMENTS @ 24" O.C. MAX. 3/4" EMT CONDUIT, TO RUN ON ROOF AND UNDER EAVES INTERIOR RAFTER SUPPORT, TYP. EXT. WALL (E) ROOF FRAMING, SEE ROOF INFO LOCATED AT EACH PANEL OPTIMIZER PV-2 ARRAY AND ROOF INFO DATE: ROOF PLANN MODULE TYPE, DIMENSIONS & WEIGHT (E) 200 A " O.C. MAX24 (E) PLUMBING VENT (E) ROOF VENT (E) SKYLIGHT PANEL TYPE: MISSION SOLAR MSE310SQ8K PANEL WEIGHT: 40.1 lb PANEL DIMENSIONS: 39.33 " X 65.53 " PANEL AREA: 17.9 SF UNIT WEIGHT OF PANELS: 40.1/17.9 = 2.24 PSF INVERTER & RACKING: 0.22 PSF AREA PER ATTACHMENT: 2'X2.46 = 4.9 SF WEIGHT PER ATTACHMENT: 4.9X2.7 = 13.23 LB 11/21/2019 SINGLE LAYER OF ROOFING PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS ROOF AREA % R #1 ƒ ƒ COMP. SHINGLE 668 429.6 2X4@24"64.3% PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS ROOF AREA % R #2 ƒ ƒ COMP. SHINGLE 434 250.6 2X4@24"57.7% RAPID SHUTDOWN LOCATION 1' - 6 " 6' - 1 " 6' - 1 " 6' - 1 " 2'-0"1' - 1 1 " MSP INV (E) UTILITY METER (E) MAIN SERVICE PANEL INSIDE BASEMENT (N) INVERTER TO BE LOCATED INSIDE BASEMENT 3/4" EMT CONDUIT, TO RUN INTO INVERTER LOCATED INSIDE BASEMENT JB ARRAY 2 14 SOLAR MODULES 46 ATTACHMENTS @ 24" O.C. MAX.4'-2"2'-5" 2'-0" 1'-6"6'-7"6'-7"1'-6"03/18/20 David Rutti WITH ALUMINUM FLASHING ALUMINUM "L" BRACKET IRONRIDGE FLASHFOOT IRONRIDGE XR-10 5/16" STAINLESS STEEL LAG BOLT MIN. 2.5"PENETRATION SEALED W/ M1 SEALANT (E) ROOF FRAMING, SEE ROOF INFO MATCH (E) ROOF SLOPE PV MODULES Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46) SCALE: N. T. S.ATTACHMENT DETAIL PV-2A DATE: ATTACHMENT DETAILS 11/21/20190'-4" 03/18/20 David Rutti Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46)PV-3 DATE: ELECTRICAL LINE DIAGRAM ELECTRICAL SINGLE LINE DIAGRAM 7.440kW SOLAR ARRAY 24 MISSION SOLAR 310W MODULES TOTAL MISSION SOLAR MSE310SQ8K 310W Vmp= 33.11V Voc= 40.09V Isc= 9.82A Imp= 9.36A CEC PTC POWER=285.7W LOW MEAN TEMP PER ASHRAE HANDBOOK MFR VOLTAGE TEMP COEFFICIENT (oC) VOLTAGE LOW TEMP. CORR. (oC) HIGH AMBIENT TEMP (oC) CONDUIT HEIGHT (in) ROOF TOP ADDED TEMP PER Table  %  ‹ R& ADJUSTED TEMP ROOF -22 -0.28 1.13 44 0.5-3.5 19 63 WALL -22 44 N/A 0 44 ATTIC -22 56 N/A 0 56 7.6kW INVERTER SOLAREDGE SE7600H-US (240V) (SI1) INVERTER 240 VAC, 32A NEMA 3R, UL LISTED, (WITH INTEGRATED DC DISCONNECT) 600 V, NEMA 3R W/ EUROSTRIP OR POLARIS IT CONNECTORS JUNCTION BOXA B ELECTRICAL EQUIPMENT CALLOUTS SOLAREDGE SE7600H-US (240V) (SI1)INVERTER MAX DC VOLTAGE: 480V DC VOLTAGE INPUT RANGE: 400-480V @ 240V PEAK POWER TRACKING VOLTAGE: 400-480V @ 240V AC NOMINAL VOLTAGE/RANGE: 211-264V @ 240V MAX AC OUTPUT CURRENT: 32A CEC WEIGHTED EFFICIENCY: 99.2% @ 240V 120%RULE BUS BAR MAIN BREAKER ALLOWED MAX PV OCPD 200 200 40 PV BREAKER IS TO BE LOCATED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. 11/21/2019 STRINGS CONNECTED IN PARALLEL SOLAREDGE POWER OPTIMIZER P320 (240V) MAX DC VOLTAGE: 48V DC VOLTAGE INPUT RANGE: 8-48V @ 240V PEAK POWER TRACKING VOLTAGE: 8-48V @ 240V DC NOMINAL VOLTAGE/RANGE: 8-60 @ 240V MAX DC OUTPUT CURRENT: 15ADC CEC WEIGHTED EFFICIENCY: 98.8% @ 240V MAX PV VOLTAGE & CURRENT CALCS: ZKZ>KtdDW;ȗͿ͗;WZ^,Z HANDBOOK) -2 TEMP COEFFICIENT (Voc) PER MANUFACTURER: -0.28 %/C VOLTAGE CORRECTION: 1.13 Vcorrection X Voptm 1.13 *400 = 452 V OUTPUT FROM POWER OPTIMIZER PER STRING: 9.30 ADC 1.00 X Iopt 1.00 * 9.30 = 9.30 ADC WIRE TAG # CONDUIT WIRE QTY (CARRY CURRENT) WIRE GAUGE (AWG) WIRE TYPE WIRE LENGTH (FEET) TEMP RATING: WIRE LOCATION ADJUSTED WIRE TEMP WIRE AMP TEMP CORRECTION PER TABLE 310.15(B)(2)(a): CONDUIT FILL PER Table 310.15(B)(3)(a): WIRE OCP: TERMINAL 75oC RATING STRINGS PER SET OF WIRES (DC) OR # 0F INVERTERS: SHORT CIRCUIT CURRENT (DC) OR AC OUTPUT NEC 690.8(A) NEC 690.8(B) STRING AMPS GROUND SIZE GROUND TYPE OCPD CHECK 1 NONE 2 10 PV WIRE 15 ϵϬΣ ROOF 63 40 X 0.65 X 1 = 26 35 1 X 9.30 X 1.00 X 1 = 9.3 #6 SBC NONE 2 3/4" EMT 4 10 THWN-2 60 ϵϬΣ ROOF 63 40 X 0.65 X 0.8 = 20.8 35 1 X 9.30 X 1.00 X 1 = 9.3 #8 THWN-2 NONE 3 3/4" EMT 3 8 THWN-2 5 ϵϬΣ WALL 44 55 X 0.87 X 1 = 47.85 50 1 X 32.00 X 1.25 X 1 = 40 #8 THWN-2 40A 2P (E)200 A MAIN SERVICE DISCONNECT JB STRING 2 7,/7ƒ $=,087+ƒ STRING 1 7,/7ƒ $=,087+ƒƒ A 12 OPTIMIZERS/MODULES IN SERIES W/ INTEGRATED RAPID SHUTDOWN 12 OPTIMIZERS/MODULES IN SERIES W/ INTEGRATED RAPID SHUTDOWN TO UTILITY GRID BOND TO EXISTING UFER 1PH, 120/240V, 3W BI-DIRECTIONAL UTILITY METER (E)200 A MAIN SERVICE PANEL NO CENTER MAIN BREAKER 2-POLE 40A PV BREAKER, BACKFED B EXISTING AC GROUNDING ELECTRODE 03/18/20 David Rutti Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46)PV-3A DATE: ELECTRICAL NOTES, LOAD CALCS ELECTRICAL NOTES 11/21/2019 GROUNDING: IRONRIDGE INTEGRATED CLAMP MODEL # 1 4"-20 UL LISTED #2703 "PV SYSTEM TO BE IRREVERSIBLY CONNECTED TO UFER, IF UFER IS NOT PRESENT IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING GROUNDING UP TO CODE." 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATICALL DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAINTIGHT THREADLESS COMPRESSION TYPE. 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS, PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 9. JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM. (NEC 690.34) 10. IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM, THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWNIG WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE : " WARNING - ELECTRIC SHOCK HAZARD. THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS." (NECE 690.35(F)) 11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A) RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ IRONRIDGE INTEGRATED GROUNDING.. 03/18/20 David Rutti Solar Photovoltaic System MICHELLE BELL 33 THORNHURST DR CARMEL, IN 46032 (317) 289-3829 RECTIFY LLC DBA RECTIFY SOLAR 133 W. MARKET ST #268. INDIANAPOLIS, IN, 46204 PHONE: (812) 325-3537 (812) 583-3341 CSLB: #1014694 (C-46) 1. PROVIDE A PLACARD WITH THE FOLLOWING WORDING IN 1 4" HIGH LETTERING PER NEC 690.17. WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THE FOLLOWING WORDING: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED 3. ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING WORDING: WARNING: PHOTOVOLTAIC POWER SOURCE MARKING SHALL BE REFLECTIVE AND PLACED EVERY 10 FEET AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND AT ALL PV COMBINER AND JUNCTION BOXES. 2. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. 4. PER NEC 690.64 AND 705.12(D)(4) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. LOCATED AT BACKFED BREAKER 5. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER NEC690.35(F) WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. 6. LABEL FOR SOLAR AC DISCONNECT: "SOLAR AC DISCONNECT" 7. PROVIDE WARNING LABEL AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING: WARNING ELECTRICAL SHOCK HAZARD. IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUNDED AND ENERGIZED. 8. PLAQUE TO BE INSTALLED ON FACE OF THE UTILITY AC DISCONNECT: PV SYSTEM DISCONNECT FOR UTILITY OPERATION 9. TO BE INSTALLED ON THE FACE OF THE SERVICE METER PANEL: CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL ALSO HAVE LABEL IDENTIFIED EVERY 10 FEET - AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS - WITH A MINIMUM OF 3/8" HIGH WHITE LETTERING ON RED BACKGROUND READING: WARNING INVERTER CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN 10. PLAQUE TO BE INSTALLED ON THE FACE OF THE SERVICE METER PANEL: 11. LABEL FOR SOLAR DC DISCONNECT: "SOLAR DC DISCONNECT" PV-4 DATE: REQUIRED SIGNAGE 11/21/2019 THORNHURST DR PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 13. PLAQUE TO BE INSTALLED AT ELECTRIC SERVICE: 12. LABEL FOR SOLAREDGE SE7600H-US (240V) (SI1) INVERTER: GRID-TIED PHOTOVOLTAIC POWER SOURCE OPERATING CURRENT = 9.30 A OPERATING VOLTAGE = 400 V MAX SYSTEM VOLTAGE = 452 V MAX SYSTEM CURRENT = 11.6 A MAX INVERTER OUTPUT = 7.6 kW, 32 A, 240VAC UTILITY METER MAIN SERVICE PANEL (INSIDE BASEMENT) EQUIPMENT AT DC DISCONNECT INVERTER (INSIDE BASEMENT) 21 1 2 3 EQUIPMENT AT EACH MODULE OPTIMIZER 3 PLACARDS ARE TO BE INSTALLED BASED ON AHJ REQUIREMENTS 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti 03/18/20 David Rutti