HomeMy WebLinkAboutMichelle Bell Plan setRECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
PV-1
PV-1 PROJECT INFORMATION
PV-1A SITE PLAN, HOUSE PHOTO
PV-2 ROOF PLAN
PV-2A ATTACHMENT DETAILS
PV-3 ELECTRICAL LINE DIAGRAM
PV-3A ELECTRICAL NOTES, LOAD CALCS
PV-4 REQUIRED SIGNAGE
PROJECT INFORMATION VICINITY MAPPLAN SET LEGEND
SUB SERVICE PANEL
AC DISCONNECT
DC DISCONNECT
SOLAR LOAD CENTER
INVERTER
SUB
AC
DC
SLC
INV
JUNCTION BOXJB
COMBINER BOX CB
ABBREVIATIONS
EXTERIOR
INTERIOR
EXT
INT
NEW(N)
EXISTING(E)
ELECTRICAL METALLIC TUBINGEMT
RIGID METALLIC TUBINGRMT
VOLTAGE OPEN CIRCUITVOC
VOLTAGE AT MAX. POWERVMP
SHORT CIRCUIT CURRENTISC
CURRENT AT MAX. POWERIMP
MONITORING METERM
NOT TO SCALENTS
OCCUPANCY: R-3
CONSTRUCTION TYPE: VB
UNSPRINKLERED
MAIN SERVICE PANELMSP
DEVICERS RAPID SHUTDOWN
DATE:
PROJECT
INFORMATION
N
PROJECT
SITE
AHJ NOTES SHEET INDEXAPPLICABLE CODES
PROJECT INFO
24 X 310 W MISSION SOLAR
MSE310SQ8K
ROOF MOUNTED SOLAR
PHOTOVOLTAIC MODULES
1 X 7600 W Solaredge SE7600H-US (240V)
(SI1)
24 X 320 W Solaredge P-320 Power
Optimizer
SYSTEM SIZE: 7.440 kW DC STC
ARRAY AREA: 430 SF
AHJ: INDIANAPOLIS
APN: 290-925-102-037-000-018
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
11/21/2019
ALL CONDUIT TO RUN ON EXTERIOR
OF HOUSE UNLESS OTHERWISE NOTED
ALL WORK TO COMPLY WITH
THE FOLLOWING CODES:
2014 NEC
2014 INDIANA BUILDING CODE
2014 INDIANA MECHANICAL CODE
2012 INDIANA PLUMBING CODE
2014 INDIANA FIRE CODE
03/18/20
David Rutti
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)
MSP SIZE IS AN TOTAL # OF PANELS
PL
(E) POOL
DRIVEWAY
MSP
LOCATED AT EACH
PANEL
OPTIMIZER
PV-1A
HOUSE PHOTO
DATE:
SITE PLAN, HOUSE
PHOTO
SCALE: N.T.S.
ARRAY LOCATION
SCALE: 1":20'-0" SITE PLAN
N
(E) 200 A 24
THORNHURST DR
24 SOLAR MODULES 11/21/2019
(E) ONE -STORY
HOUSE
RAPID SHUTDOWN
LOCATION
142'-0"113'-6"158'-6"93'-3"32'-
1
1"
PL
PL
PL
PL
(E) DETACHED
GARAGE
M
(E) MAIN SERVICE
PANEL
INSIDE BASEMENT
(E) UTILITY
METER
INV
(N) INVERTER TO BE
LOCATED INSIDE BASEMENT
1 256'-1"19'-0"21'-10"10'-6"10'-10"
28'-3"
1
1
1
1
1
1
1
1
1
1
122 22 2 22222203/18/20
David Rutti
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)
SCALE: 1":10'-0" ROOF PLAN
MSP SIZE IS AN
ATTACHMENT POINTS:R1R2M JBARRAY 1
10 SOLAR MODULES
36 ATTACHMENTS
@ 24" O.C. MAX.
3/4" EMT CONDUIT,
TO RUN ON ROOF
AND UNDER EAVES
INTERIOR RAFTER
SUPPORT, TYP.
EXT. WALL
(E) ROOF
FRAMING, SEE
ROOF INFO
LOCATED AT EACH
PANEL
OPTIMIZER
PV-2
ARRAY AND ROOF INFO
DATE:
ROOF PLANN
MODULE TYPE, DIMENSIONS & WEIGHT
(E) 200 A
" O.C. MAX24
(E) PLUMBING
VENT
(E) ROOF VENT
(E) SKYLIGHT
PANEL TYPE: MISSION SOLAR MSE310SQ8K
PANEL WEIGHT: 40.1 lb
PANEL DIMENSIONS: 39.33 " X 65.53 "
PANEL AREA: 17.9 SF
UNIT WEIGHT OF PANELS: 40.1/17.9 = 2.24 PSF
INVERTER & RACKING: 0.22 PSF
AREA PER ATTACHMENT: 2'X2.46 = 4.9 SF
WEIGHT PER ATTACHMENT: 4.9X2.7 = 13.23 LB
11/21/2019
SINGLE LAYER OF ROOFING
PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS
ROOF
AREA %
R #1 COMP. SHINGLE 668 429.6 2X4@24"64.3%
PITCH AZIMUTH MATERIAL SP SQ.FT ARRAY SQ.FT RAFTER SPECS
ROOF
AREA %
R #2 COMP. SHINGLE 434 250.6 2X4@24"57.7%
RAPID SHUTDOWN
LOCATION
1'
-
6
"
6'
-
1
"
6'
-
1
"
6'
-
1
"
2'-0"1'
-
1
1
"
MSP
INV
(E) UTILITY
METER
(E) MAIN SERVICE
PANEL INSIDE
BASEMENT
(N) INVERTER TO BE
LOCATED INSIDE
BASEMENT
3/4" EMT CONDUIT,
TO RUN INTO INVERTER
LOCATED INSIDE BASEMENT
JB
ARRAY 2
14 SOLAR MODULES
46 ATTACHMENTS
@ 24" O.C. MAX.4'-2"2'-5"
2'-0"
1'-6"6'-7"6'-7"1'-6"03/18/20
David Rutti
WITH ALUMINUM FLASHING
ALUMINUM "L" BRACKET
IRONRIDGE FLASHFOOT
IRONRIDGE XR-10
5/16" STAINLESS STEEL LAG BOLT
MIN. 2.5"PENETRATION SEALED W/
M1 SEALANT
(E) ROOF FRAMING, SEE ROOF INFO
MATCH (E) ROOF SLOPE
PV MODULES
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)
SCALE: N. T. S.ATTACHMENT DETAIL
PV-2A
DATE:
ATTACHMENT
DETAILS
11/21/20190'-4"
03/18/20
David Rutti
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)PV-3
DATE:
ELECTRICAL LINE
DIAGRAM
ELECTRICAL SINGLE LINE DIAGRAM
7.440kW SOLAR ARRAY
24 MISSION SOLAR 310W MODULES TOTAL
MISSION SOLAR MSE310SQ8K 310W
Vmp= 33.11V Voc= 40.09V
Isc= 9.82A Imp= 9.36A
CEC PTC POWER=285.7W
LOW MEAN TEMP
PER ASHRAE
HANDBOOK
MFR VOLTAGE TEMP
COEFFICIENT (oC)
VOLTAGE LOW
TEMP. CORR. (oC)
HIGH AMBIENT
TEMP (oC)
CONDUIT
HEIGHT (in)
ROOF TOP ADDED
TEMP PER Table
%R&
ADJUSTED
TEMP
ROOF -22
-0.28 1.13
44 0.5-3.5 19 63
WALL -22 44 N/A 0 44
ATTIC -22 56 N/A 0 56
7.6kW INVERTER
SOLAREDGE SE7600H-US (240V) (SI1)
INVERTER 240 VAC, 32A NEMA 3R, UL LISTED,
(WITH INTEGRATED DC DISCONNECT)
600 V, NEMA 3R W/
EUROSTRIP OR POLARIS IT CONNECTORS
JUNCTION BOXA
B
ELECTRICAL EQUIPMENT CALLOUTS
SOLAREDGE SE7600H-US (240V) (SI1)INVERTER
MAX DC VOLTAGE: 480V
DC VOLTAGE INPUT RANGE: 400-480V @ 240V
PEAK POWER TRACKING VOLTAGE: 400-480V @ 240V
AC NOMINAL VOLTAGE/RANGE: 211-264V @ 240V
MAX AC OUTPUT CURRENT: 32A
CEC WEIGHTED EFFICIENCY: 99.2% @ 240V
120%RULE
BUS BAR MAIN BREAKER ALLOWED MAX
PV OCPD
200 200 40
PV BREAKER IS TO BE LOCATED AT
THE OPPOSITE END OF THE BUS BAR
FROM THE MAIN BREAKER.
11/21/2019
STRINGS CONNECTED IN PARALLEL
SOLAREDGE POWER OPTIMIZER P320 (240V)
MAX DC VOLTAGE: 48V
DC VOLTAGE INPUT RANGE: 8-48V @ 240V
PEAK POWER TRACKING VOLTAGE: 8-48V @ 240V
DC NOMINAL VOLTAGE/RANGE: 8-60 @ 240V
MAX DC OUTPUT CURRENT: 15ADC
CEC WEIGHTED EFFICIENCY: 98.8% @ 240V
MAX PV VOLTAGE & CURRENT CALCS:
ZKZ>KtdDW;ȗͿ͗;WZ^,Z
HANDBOOK) -2
TEMP COEFFICIENT (Voc) PER
MANUFACTURER: -0.28 %/C
VOLTAGE CORRECTION: 1.13
Vcorrection X Voptm
1.13 *400 = 452 V
OUTPUT FROM POWER OPTIMIZER PER
STRING: 9.30 ADC
1.00 X Iopt
1.00 * 9.30 = 9.30 ADC
WIRE TAG # CONDUIT WIRE QTY
(CARRY
CURRENT)
WIRE
GAUGE
(AWG)
WIRE TYPE WIRE
LENGTH
(FEET)
TEMP
RATING:
WIRE
LOCATION
ADJUSTED
WIRE TEMP
WIRE
AMP
TEMP
CORRECTION
PER TABLE
310.15(B)(2)(a):
CONDUIT FILL
PER Table
310.15(B)(3)(a):
WIRE OCP: TERMINAL
75oC
RATING
STRINGS PER SET OF
WIRES (DC) OR # 0F
INVERTERS:
SHORT CIRCUIT
CURRENT (DC) OR
AC OUTPUT
NEC
690.8(A)
NEC
690.8(B)
STRING
AMPS
GROUND
SIZE
GROUND
TYPE
OCPD CHECK
1 NONE 2 10 PV WIRE 15 ϵϬΣ ROOF 63 40 X 0.65 X 1 = 26 35 1 X 9.30 X 1.00 X 1 = 9.3 #6 SBC NONE
2 3/4" EMT 4 10 THWN-2 60 ϵϬΣ ROOF 63 40 X 0.65 X 0.8 = 20.8 35 1 X 9.30 X 1.00 X 1 = 9.3 #8 THWN-2 NONE
3 3/4" EMT 3 8 THWN-2 5 ϵϬΣ WALL 44 55 X 0.87 X 1 = 47.85 50 1 X 32.00 X 1.25 X 1 = 40 #8 THWN-2 40A 2P
(E)200 A MAIN SERVICE
DISCONNECT
JB
STRING 2
7,/7
$=,087+
STRING 1
7,/7
$=,087+
A
12 OPTIMIZERS/MODULES IN SERIES
W/ INTEGRATED RAPID SHUTDOWN
12 OPTIMIZERS/MODULES IN SERIES
W/ INTEGRATED RAPID SHUTDOWN
TO UTILITY GRID
BOND TO
EXISTING UFER
1PH, 120/240V,
3W
BI-DIRECTIONAL
UTILITY METER
(E)200 A MAIN
SERVICE
PANEL
NO CENTER
MAIN BREAKER
2-POLE 40A PV BREAKER,
BACKFED
B
EXISTING AC
GROUNDING
ELECTRODE
03/18/20
David Rutti
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)PV-3A
DATE:
ELECTRICAL NOTES,
LOAD CALCS
ELECTRICAL NOTES
11/21/2019
GROUNDING:
IRONRIDGE INTEGRATED
CLAMP
MODEL # 1
4"-20
UL LISTED #2703
"PV SYSTEM TO BE IRREVERSIBLY CONNECTED TO UFER, IF UFER IS NOT PRESENT IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO BRING GROUNDING UP TO CODE."
1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATICALL DE-ENERGIZE ITS OUTPUT TO
THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL
REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC
690361)
2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAINTIGHT THREADLESS COMPRESSION TYPE.
3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED
4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,
PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE
OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER.
5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF.
6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER
APPROPRIATE NEC REQUIREMENTS.
7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS
8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED PROTECTIVE COATINGS ARE
NOT ACCEPTABLE.
9. JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM
CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND
CONNECTED BY A FLEXIBLE WIRING SYSTEM. (NEC 690.34)
10. IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM, THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWNIG WARNING AT EACH
JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE : "
WARNING - ELECTRIC SHOCK HAZARD. THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE
UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS." (NECE
690.35(F))
11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM
ANY PHYSICAL DAMAGE.
12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY.
ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250.
ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED
SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES 690.9 (A)
RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/
IRONRIDGE INTEGRATED GROUNDING..
03/18/20
David Rutti
Solar Photovoltaic System
MICHELLE BELL
33 THORNHURST DR
CARMEL, IN 46032
(317) 289-3829
RECTIFY LLC DBA
RECTIFY SOLAR
133 W. MARKET ST #268.
INDIANAPOLIS, IN, 46204
PHONE: (812) 325-3537
(812) 583-3341
CSLB: #1014694 (C-46)
1. PROVIDE A PLACARD WITH THE FOLLOWING
WORDING IN 1
4" HIGH LETTERING PER NEC 690.17.
WARNING
ELECTRICAL SHOCK HAZARD.
DO NOT TOUCH TERMINALS. TERMINALS ON BOTH
THE LINE AND LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION.
AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN
WITH THE FOLLOWING WORDING:
CAUTION:
SOLAR ELECTRIC SYSTEM CONNECTED
THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER
IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH
THE SERVICE PANEL CLOSED
3. ON ALL INTERIOR AND EXTERIOR PV CONDUIT,
RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND
JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING
WORDING:
WARNING: PHOTOVOLTAIC POWER SOURCE
MARKING SHALL BE REFLECTIVE AND
PLACED EVERY 10 FEET AT TURNS
AND ABOVE AND/OR BELOW PENETRATIONS AND AT
ALL PV COMBINER AND JUNCTION BOXES.
2. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF
3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD),
WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND
AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL.
PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED
OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO
PLATING, IN A CONTRASTING COLOR TO THE PLAQUE.
PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT
WITH POP-RIVETS OR SCREWS.
4. PER NEC 690.64 AND 705.12(D)(4) EQUIPMENT CONTAINING
OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A
BUSBAR FROM MULTIPLE SOURCES SHALL BE MARKED TO
INDICATE THE PRESENCE OF ALL SOURCES.
LOCATED AT BACKFED BREAKER
5. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE
FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX,
DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED
CIRCUITS MAY BE EXPOSED DURING SERVICE PER NEC690.35(F)
WARNING
ELECTRIC SHOCK HAZARD.
THE DC CONDUCTORS OF THIS PHOTOVOLTAIC
SYSTEM ARE UNGROUNDED AND MAY BE
ENERGIZED.
6. LABEL FOR SOLAR AC DISCONNECT:
"SOLAR AC DISCONNECT"
7. PROVIDE WARNING LABEL AT THE UTILITY
INTERACTIVE INVERTER OR GROUND FAULT
INDICATOR STATING:
WARNING ELECTRICAL SHOCK HAZARD. IF A
GROUND FAULT IS INDICATED, NORMALLY
GROUNDED CONDUCTORS MAY BE
UNDERGROUNDED AND ENERGIZED.
8. PLAQUE TO BE INSTALLED ON FACE OF THE
UTILITY AC DISCONNECT:
PV SYSTEM DISCONNECT
FOR UTILITY OPERATION
9. TO BE INSTALLED ON THE FACE OF THE
SERVICE METER PANEL:
CAUTION:
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH DISCONNECT
LOCATED AS SHOWN
ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE
BUILDING SHALL BE INSTALLED IN A METALLIC
RACEWAY AND SHALL ALSO HAVE LABEL IDENTIFIED
EVERY 10 FEET - AND WITHIN 1 FOOT OF TURNS OR
BENDS AND WITHIN 1 FOOT ABOVE AND BELOW
PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS
OR BARRIERS - WITH A MINIMUM OF 3/8" HIGH WHITE
LETTERING ON RED BACKGROUND READING:
WARNING
INVERTER CONNECTION.
DO NOT RELOCATE THIS OVERCURRENT DEVICE.
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS AS SHOWN
10. PLAQUE TO BE INSTALLED ON THE FACE OF THE
SERVICE METER PANEL:
11. LABEL FOR SOLAR DC DISCONNECT:
"SOLAR DC DISCONNECT"
PV-4
DATE:
REQUIRED SIGNAGE
11/21/2019
THORNHURST DR
PHOTOVOLTAIC SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
13. PLAQUE TO BE INSTALLED AT ELECTRIC SERVICE:
12. LABEL FOR SOLAREDGE SE7600H-US (240V) (SI1) INVERTER:
GRID-TIED PHOTOVOLTAIC POWER SOURCE
OPERATING CURRENT = 9.30 A
OPERATING VOLTAGE = 400 V
MAX SYSTEM VOLTAGE = 452 V
MAX SYSTEM CURRENT = 11.6 A
MAX INVERTER OUTPUT = 7.6 kW, 32 A, 240VAC
UTILITY METER
MAIN SERVICE
PANEL (INSIDE
BASEMENT)
EQUIPMENT AT
DC DISCONNECT
INVERTER (INSIDE
BASEMENT)
21
1
2
3
EQUIPMENT AT
EACH MODULE
OPTIMIZER
3
PLACARDS ARE TO BE INSTALLED BASED ON AHJ REQUIREMENTS
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti
03/18/20
David Rutti