oi UNIT B7-A3 - ONE BEDROOM
Ab100% SCALE: 1/4" = 1'-0"
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
,
�{�n„� i,.�awa'
�
onrE: 03/19/20
� nz UNIT B1-B2 - TWO BEDROOM
Ai-100 SCALE: 1I4" = 1'-0"
•P.•
/ o� UNIT B7-A2 - ONE BEDROOM
Ai-102 SCALE: 1I4" = 1'-0"
f
�
�
d
¢
�
os UNIT B7-A1 - ONE BEDROOM
Ai-102 SCALE: 1I4" = 1'-0"
A5 � UNIT B1-B1 - TWO BEDROOM
Ai-102 SCALE: 1/4" = 1'-0"
GENERAL NOTES - INTERIOR FRAMING
1. ALLMATERIALSANDWORKSHALLBEFURNISHEDANDINSTALLEDIN
WORKMANSHIP-LIKE MANNER IN STRICT ACCORDANCE WITH ALL
PREVAILING LOCAL, STATE, AND NATIONAL BUILDWG CODES.
2. CONTRACTORSSHALLSTORE,HANDLE,AND WSTALLALLPRODUCTSAND
ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS,
RECOMMENDATIONS, AND PROCEDURES IN ORDER TO ENSURE THE
MANl1FACTURER'S WARRANTV IS VALIDATED.
3. SUB-CONTRAGTORSSHALLVERIFVALLDIMENSIONS.
4. ALL DIMENSIONS ARE GIVEN FROM STUD TO STUD, UNLE55 OTHERW ISE
NOTED.
5. STUD DIMENSIONS ARE 3 VT' OR 5 1/2" UNO.
6. ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR
OTHER LOCATIONS.
]. UNITLAYOUTISASSHOWNON'/."SCALEPLANS.FORBWLDING
DIMENSIONS, REFER TO 1/8" SCALE OVERALL BUILDING FLOOR PLANS.
8. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL,
PLUMBING, AND ELECTRICAL CONTRACTOR S FOR ALL RESPECTIVE
OPENINGS, AS REQUIRED, MCLUDING MAINTAINWG FlRE RATED
ASSEMBLIES.
9. FOR MATERIALS AND FlNISHES, REFER TO FlNISH SCHEDULES ON THIS
SHEET.
10. TYPE "X" Sl8" THICK GVPSUM BOARD SHALL BE USED AT RATED WALL
CONSTRl1CTION INCW DING BEARING WALLS. TVPE "C" 5/8" GYPSl1M BOARD
SHALL BE USED AT CEILINGS. REFER TO UL ASSEMBLIES.
11. ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATED
CONSTRUCTION WITH DAMPERS AT ALL DUCT PENETRATIONS. REFER TO
MECHANICAL DRAW INGS.
12 ALL WALLS W HICH FORM PERIMETERS OF DWELLING UNITS AND ALL LOAD
BEARING WALLS SHALL BE MIN. 1 HOUR FlRE RATED UL-U3050R UL-U314
ASSEMBLV. NON- LOAD BEARING INTERIOR PARTITIONS WITHIN �WELLING
UNITS DO NOT REQUIRE FIRE RATING.
13. USEMIN.3/8"OSB ATALLATTICDRAFTSTOPS.
14. REFER TO STRUCTURAL FOR ALL W INDOW AND DOOR HEADER SRES.
15. CONTRACTOR TO PROVIDE: (1) iP' WOOD SHELF AND ROD IN ALL ENTRV
CLOSET$ (1 � 72" WOOD SHELF, ROD, AND VERTICAL SHELVWG IN BEDROOM
CLOSETS, (1) 12" WOOD SHELF AT LAUNDRV, (5) 12" DEEP WOOD SHELVES IN
LINEN CLOSETS, AND (5) 18" DEEP WOOD SHELVES IN PANTRV. PROVIDE
SHELVES IN BATH ROOM AS SHOWN . REFER TO DRAW INGS.
i6. REFERTOSTRUCTURALDRAWINGSFORINTERIORBEARINGWALLMEMBER
SIZE AND SPAGNG.
17. FLOOR TOPPMG TO BE 3l4" GVPCRETE 2000 OR APPROVED EQUAL.
CONTRACTOR TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER
HEIGHTS ABOVE SUB-FLOOR ACCORDINGLY.
18. CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL EXTERIOR
WALLS. PROVIDE TYVEK VAPOR BARRIER ON ALL EXTERIOR WALLS.
19. ALL WALL AND CEILING GVPSUM BOARD TO BE SMOOTH FlNISH COATWG.
REFER TO FINISH SCHEDULE FOR SHEEN.
20. PROVI�EWASHERAN��RVERHOOKUPSINALLUNITSASftEQUIREDTO
MEET OR EXCEED APPLICABLE CODES.
21. DWELLINGUNITSEPARATIONWALLSOFAPARTMENTUNITSSHALLBEMIN.
ONE HOUR FIRE RATED CONSTRUCTION.
22. PROVIDE WOOD BLOCKING SUPPORTAS RE�UIRED. INCLUDING, BUT NOT
LIMITED TO'. ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL
STAIR RAILS, SUPPORT FOR SHEATHING EDGES NOT ON FRAMING KITCHEN
WALL CABMETS ON ALL FLOORS, AND AT N WALL LOCATIONS.
23. PROVIDE R43 (3'/z") MIN. ACOUSTIC BATT INSULATION IN ALL DW ELLING
UNIT SEPARATION WALLS. IN CEILINGS PROVIDE R-03 (3 %") MIN. ACOUSTIC
BATT INSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A
HARD FLOOR SURFACE. PROVIDE R49 (5 1l2") MIN. PAPER FACED THERMAL
BATT INSULATION M EXTERIOR WALLS. PROVIDE R30 (9") MIN. IN CEILING
ABOVE GARAGES. PROVIDE R38 (11") MIN. M CEILING BELOW ROOF AREAS.
24. ALL LIV WG UNITS SHALL BE CONSTRUCTED TO COMPLV W ITH OBC
A�APTABLE UNIT TVPE "6" REQUIREMENTS, UNLE55 �ESIGNATE� ADA
ACCESSIBLE UNIT TVPE "A" IN UNITS LOCATIONS SHOWN.
25. PROVIDE CONTROL JOINTS IN CORRIDOR GVPSUM BOARO CEILING 30 FEET
O.G WITH RESILIENT CHANNELS, TVPICAL.
26. STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE
INDIVIDUALLV PROTECTED BV A ONE-HOUR FIRE RESISTANCE RATED
ASSEMBLV.
GENERAL NOTES -ACCESSIBILITY
ALL DW ELLING UNITS SHALL COMPLV W ITH THE FOLLOW ING:
1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST 15" AND NO MORE
THAN 19" MEASURED TO THE TOP OF THE TORET SEAT.
2. THE DIAMETER OR W IDTH OF THE GRIPPWG SURFACES OF A BRAG BAR OR
HANDRAIL SHALL BE 1.1/4" TO 1-1/2".
3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS
AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS
3.1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCES BV THE
MAXIMUM BENDMG MOMENT FROM THE APPLICATION OF 250 LBF
SHALL BE LESS THAN THE ALLOWABLE STRESS OF THE MATERIAL
OF THE GRAB BAR OR SEAT.
32 SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BV THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAR. IF
THE CONNECTION BETWEEN THE GRAB BAR AND ITS MOUNTING
BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLV
RESTftAMED, THEN DIRECT AND TORSIONAL SHEAR STRESSES
SHALL BE TOTALED FOR THE COMBINED SHEAR STRE55, WHICH
SHALL NOT E%CEEDED THE ALLOWABLE SHEAR STRESS.
3 3. SHEAR FORCE INDUCEO IN A FASTENER OR MOUNTING DEVICE
FROM THE APPLICATION OF 250 LBF SHALL BE LESS THAN THE
ALLOWABLE LATERAL LOAD OF BTHER THE FASTENER OR
MOUNTING DEV ICE OR THE SUPPORTING STRl1CTlIRE, W HICHEVER
IS THE SMALLER ALLOWABLE LOAD.
34. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION
FORCE OF 250 LBF PLUS THE MAXIMUM MOMENT FROM THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE
W ITHORAWAL AND THE SUPPORTING STRl1CTURE.
3.5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FlTTINGS.
TYPE'B' ACCESSIBLE UNIT
ALL UNITS NOT DESIGNATED AS TVPE'A' PER BUILDING FLOOR PLAN SHEETS A1401
THRU Ai-1048
1. PRIMARY ENTRANCE �OOR HAR�WARE TO BE LEVER TYPE LOCKING
MECHANISM TO BE ACCESSIBLE PUSH BUTTON TVPE PER ANSI 1003.5
2 ALL THRESHOLDS TO BE VT' MAXIMUM CHANGE M LEVEL FROM TOP OF
THRESHOLD TO FINISHED FLOOR. PATIO SURFACE SHALL BE 4" MAXIMUM
BELOW FLOOft LEVEL OF ADJACENT IMERIOR SPACE
3. TOILETCENTERLINESSHALLBEIB"(MIN.)FROMWALLMEASUREDFROM
FACE OF DRVWALL.
4. PRIMARV ENTRANCE DOOR SHALL BE 36" W IDE AND HAVE 18" (MIN.) PULL
SIDE QEARANCE.
5. INTERIOR UNIT PASSAGE DOORS SHALL BE 34" W IDE (MIN.).
6. INSTALL BLOCKING FOR FUTURE GR4B BARS AT TOILETS AND TUBS
���
�-
WOOL'L'PERT
CMrtECTU0.E�nGINEEPIH6I4E0A1T11L
76351nteractive Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
novo�::
�y
��
��]
i�l
�:j
��
�
�
�
�
O
W
�`
W
�
�
U �
J •
J �
�UA
C v /
Q O
� �
�
^i' �W
�
� �
� �
U�
a
K
N
m
�
N
O
N
N M
O
r �
N V
� U �
� `o m
C a
� o c
- d d
'� � £
N
m - U
Dlssuances:
Proi. No.: 074904
Date: 10/24/18
A Sheet Name:
UNIT PLANS
A1-401
4• 3'• 5'-0" 1'-OV2" 4'-10" Y_3•• ]••