HomeMy WebLinkAboutE1-501-ELECTRICAL-DETAILS-Rev.0�
UNSW ITCHED 1
CIRCUIT HPi-1�
SPAR
SPAR
ra
3
BUILDING MOUNTED
LIGHTING
SPARE 1"CON�l11TT0
OUTSIDE BUILDING
SPARE 1"CONDUITTO
OUTSIDE BUILDING
BASIS OF DESIGN:
LCP4: HUBBELL C%, ACUITY, WATT STOPPER.
SEQUENCE OF OPERATION:
ALL EXTERIOR LIGHTING SHALL OPERATE FROM DUSK TO DAW N VIA ASTRONOMICAL TIME
CLOCK. EXTERIOR EGRESS LIGHTING SHALL HAVE EMERGENCV BACKUP POWER.
n EXTERIOR LIGHTING CONTROL PANEL LCP-1
U Nrs
Cf
7
ELEVATOR SHAFT
ELEVATOR PIT
VAPORTITE LED
LIGHT FIXTURE W ITH
GLOBE
LIGHTSWITCHANO RGS ANDGUARD.HUBBELL
GFI RECEPTACLE VTG5K-G-U-W-2GG
WITH g� OREQUAL
WEATHERPROOF
COVER
3/4" RIGI� STEEL
CONDUIT
NOTE:
A. ENSURE THAT ALL ELVATOR CLEARANCES ARE MAINTAINED
B. PROVIDE SEPARATE LIGHTING AND RECEPTACLE CIRCUITS
n ELEVATOR PIT DIAGRAM
U NTs
;7
/1
C7
���
�
WOOLPERT
10.W IiERURElEN6dEERIXGI4E03P1iILL
76351nterective Way
Suite 100
G Indianapolis, IN
46278
317.299.7500
FAX: 317.291.5805
novo�::
:cj:�`:rv:,�� r F,�c:�,%':
• ND.Pc1100G2C/ ;
•1 __ - :e
o��, uL�T=4. ; p-
:�Vo ��!NUIPIIP..' �4>'j
�nNN
,��'�
F
E
5
ro
�
U
W
J
W
m
C
�
�
m
V
0
rn
v
r
ro
�
E
�
�
� U
¢ o
a a
oi '
��
�
W
D �
�
O
W
�
— W
�
�
U �
C J ��
J �
�
W �
� V �
�
� � �
�
o O �
_ � L �
� �
� �o
o �
� ��
w` � U �
� W � `o m
�a
C � � o �
L � N N
U � � ��
�
B m - U
0 Issuances:
Proi. No.: 074904
Date: 10/24/18
A Sheet Name:
ELECTRICAL DETAILS
E1-501
RELEA5E0 FOR CONSTRUCTION
Suhjec��o compliance with allregula�ions
04 S�a�e antl Local Codes
City of Carmel
,
�{�n„� i,.�a�'
\
oarE: 03/19/20
67