HomeMy WebLinkAbout20010049 State CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 1/2
CONSTRUCTION DESIGN RELEASE
State Form 41191 (R9/5-98)
Report Printed on:January 13, 2020
Project number Release date
412053 11/25/19
Construction type Occupancy classification
Scope of release
V-A, SPK M, R-2
Type of release
Project name
Street address
City County
ARCH ELEC FA FDN MECH
PLUM STR
Standard
Proscenium Building 1
1212 S Rangeline Rd
CARMEL HAMILTON
To: Owner / Architect / Engineer
Woolpert
James Dobrozsi AR10700165
4454 Idea Center Blvd
Beavercreek OH 45430
Note :(A1A & A1B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans
and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety
Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000.
The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of
the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions
listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All
construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with
and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation
of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and
void, if the work authorized is not commenced within one (1) year from the above date.
CONDITIONS:
14B
14B050312A
14B05042
14B0601VA
4G0603AE
A2
14B07134
14B07037
This project has been reviewed under the 2014 Indiana Building Code.
Two or more buildings on the same lot shall be regulated as separate buildings or shall be
considered as portions of one building if the building height of each building and the aggregate
building area of the buildings are within the limitations of Table 503 as modified by Sections 504 and
506. The provisions of this code applicable to the aggregate building shall be applicable to each
building in accordance with Section 503.1.2, IBC (675 IAC 13-2.6).
NOTE: This project consists of an existing underground parking structure, construction type I-A
Podium, (#397917) and a type V-A four story appartment building with a commercial shell space.
Sprinklers are being provided for this project to increase the number of story levels or 20 feet above
Table 503 in accordance with Section 504.2, IBC (675 IAC 13-2.6).
The minimum construction type permitted for this building is Type V-A. Building elements shall be
protected as specified in Chapters 5, 6, and Table 601, IBC (675 IAC 13-2.6).
Detailed plans and specifications of the fire suppression system shall be filed with the required
application and appropriate fees in accordance with 675 IAC 12-6-3(a), 675 IAC 12-6-7(g)(17), and
675 IAC 13-1-8. (N.F.P.A. 13)
An elevator installation permit shall be obtained from the Elevator Safety Division in accordance with
IESC (675 IAC 21-1-1). Please visit: http://www.in.gov/dhs/2374.htm
Shaft enclosures shall have a fire-resistance rating of not less than 2 hours where connecting four
stories or more, and not less than 1 hour where connecting less than four stories in accordance with
Section 713.4, IBC (675 IAC 13-2.6).
Fire walls and vertical fire barriers shall be effectively and permanently identified with signs or
stenciling. Such identification shall: 1. Be located in accessible concealed floor, floor-ceiling or attic
spaces; 2. Be located within 15 feet of the end of each wall and at intervals not exceeding 30 feet
Indiana Department of Homeland Security
DIVISION OF FIRE & BUILDING SAFETY
PLAN REVIEW DIVISION
402 W. Washington St., Room E245
Indianapolis, IN 46204
Fax & e-mail:
SUPPORT HOOSIER SAFETY
Available At Your Local Licence Branch
In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform
exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a
copy of the design release.
9374610743, james.dobrozsi@woolpert.com
ELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.gov/dhs/2650.htm.
This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans.
Use Internet Browser to View this report, other browsers are not compatible to view this report
Page 2/2
14B0707310A
14B0707310B
14B071659
14B10181
14B0907
14W09077
14B11076212A
4G05
AREL
measured horizontally along the wall or partition; and 3. Include lettering not less than 3 inches in
height with a minimum 3/8 inch stroke in a contrasting color incorporating the suggested wording,
"FIRE WALL or FIRE BARRIER PROTECT ALL OPENINGS" or similar wording in accordance with
Section 703.7, IBC (675 IAC 13-2.6).
One or more fire barriers or horizontal assemblies are being provided for the purpose of separating
a single occupancy into different fire areas in accordance with Section 707.3.10, IBC (675 IAC 13-
2.6).
One or more fire barriers or horizontal assemblies are being provided for the purpose of separating
mixed occupancies into different fire areas in accordance with Section 707.3.10, IBC (675 IAC 13-
2.6).
Fire doors shall be self-closing or automatic-closing in accordance with Section 716.5.9, IBC (675
IAC 13-2.6).
Corridors shall be fire-resistance rated in accordance with Table 1018.1, IBC (675 IAC 13-2.6).
NOTE: Flexible air ducts, both metallic and nonmetallic, shall comply with Sections 603.6.1,
603.6.1.1, 603.6.3 and 603.6.4, IMC. Flexible air connectors, both metallic and nonmetallic, shall
comply with Sections 603.6.2 through 603.6.4, IMC, in accordance with Section 603.6, IMC.
The fire alarm system shall be designed as specified in Section 907, IFC, and N.F.P.A. 72, in
accordance with Section 907, IBC (675 IAC 13-2.6).
Upon completion of the installation of the fire alarm system, a satisfactory test of the entire system
shall be made. All functions of the system or alteration shall be tested in accordance with Section
907.7, IFC (675 IAC 22-2.5).
Type B units shall be provided in R-2 occupancies in accordance with Section 1003, ICC A117.1,
2009 edition and Section 1107.6.2.1.2, Chapter 11, IBC (675 IAC 13-2.6).
All conditions set forth by the Indiana Fire Prevention and Building Safety Commission on variance
submissions shall be considered part of the release documents and do not apply to future additions
or alterations of this structure in accordance with 675 IAC l2-5. 19-05-57; One unisex restroom
facility in amenity area.
Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from
required compliance with all applicable rules of the commission, even if noncompliant conditions
appear in the plans and specifications that have been filed with the division. The owner is
responsible for correcting any and all areas of noncompliance even if they are discovered
subsequent to the issuing of this design release.
Please be advised that if an administrative review of this action is desired, a written petition for review must be filed at the above address with the
Fire Prevention and Building Safety Commission identifying the matter for which a review is sought no later than eighteen (18) days from the above -
stated date, unless the eighteenth day falls on a Saturday, a Sunday, a legal holiday under State statute, or a day in which the Department of Fire
and Building Services is closed during normal business hours. In the latter case, the filing deadline will be the first working day thereafter. If you
choose to petition, and the before-mentioned procedures are followed, your petition for review will be granted, and an administrative proceeding will
be conducted by an administrative law judge of the Fire Prevention and Building Safety Commission. If a petition for review is not filed, this Order will
be final, and you must comply with its requirements.
Code review official
Address (name,title of local official,street,city,state and ZIP code
KEVIN HANSON
JIM BLANCHARD
ONE CIVIC SQUARE
CARMEL,IN 46032
DEPT OF COMMUNITY SERVICE
Fax & e-mail: 3175712499, jblanchard@carmel.in.gov
Indiana State Building Commissioner khanson@dhs.in.gov