GENERAL NOTES - INTERIOR FRAMING
s� UNIT B4-C3 - TWO BEDROOM
A4-103 SCALE: 1/4" = 1'-0"
ALL MATERIALS AND WORK SHALL BE FURNISHED AND INSTALLED IN
WORKMANSHIP-LME MANNER IN STRICT ACCORDANCE WITH ALL PREVAILING
LOCAL, STATE, AND NATIONAL BUILDING CODES.
CONTRACTORS SHALL STORE, HANDLE AND INSTALL ALL PRO�UCTS AND
ASSEMBLIES PER THE MANUFACTURER'S INSTRUCTIONS, RECOMMENDATIONS,
AND PROCEDURES IN ORDER TO ENSURE THE MANUFACTURER'S WARRANTY IS
VALIDATED.
SUB-CONTRACTORS SHALL VERIFV ALL DIMENSIONS.
ALL �IMENSIONS ARE GIVEN FROM STUD TO STUD, UNLE55 OTHERW ISE NOTE�.
STUD DIMENSIONS ARE 31/2" OR 5112" UNO.
ALL EXTERIOR WALLS ARE TO BE 2x6 STUDS. REFER TO STRUCTURAL FOR OTHER
LOCATIONS.
UNIT LAYOUT IS AS SHOW N ON'/." SCALE PLANS. FOR BUILDWG DIMENSIONS,
REFER TO 1I8" SCALE OVERALL BUILDING FLOOR PLANS.
GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL, PLUMBING, AND
ELECTRICAL CONTRACTOR 5 FOR ALL RESPECTNE OPENINGS, AS REpUIRED,
INC W DING MAINTAINING FIRE RATED ASSEMBLIES.
FOR MATERIALS AND FINISHES, REFER TO FINISH SCHE�ULES ON THIS SHEET.
TVPE "X" 5/8" THICK GVPSUM BOARD SHALL BE USED AT RATED WALL
CONSTRUCTION INCWDING BEARING WALLS. TVPE "C' SIS" GVPSUM BOARD SHALL
BE USE� AT CEILINGS. REFER TO UL ASSEMBLIES.
ALL CEILING ASSEMBLIES ARE TO BE MIN. 1 HOUR FIRE RATEO CONSTRl1CTION
WITH �AMPERS AT ALL �UCT PENETRATIONS. REFER TO MECHANICAL DRAWINGS.
ALL WALLS WHICH FORM PERIMETERS OF �WELLING UNITS AND ALL LOAD
BEARING WALLS SHALL BE MIN. 1 HOUR FIRE RATED ULU305 0R ULU314
ASSEMeLV. NON- LOAD BEARING INTERIOR PARTITIONS WITHIN DWELLWG UNITS
�O NOT REpUIRE FIRE RATING.
USE MIN. 3/8" OSB AT ALL ATTIC DRAFT STOPS.
REFER TO STRUCTURAL FOR ALL WINDOW AND DOOR HEADER SIZES.
CONTRACTOR TO PROVIDE: (1) 12' WO00 SHELF ANO ROD IN ALL ENTRV CLOSETS,
(1) 12" W00� SHELF, ROR AND VERTICAL SHELVING IN BEDROOM CLOSETS, (1) 12"
WOOD SHELF AT LAUNORV, (5) 12" DEEP WOO� SHELVES IN LINEN CLOSETS, AND
(5) 18" OEEP WOOD SHELVES IN PANTRV. PROVIDE SHELVES IN BATH ROOM AS
SHOWN . REFER TO DRAWINGS.
REFER TO STRUCTURAL DRAW INGS FOR IMERIOR BEARING WALL MEMBER SRE
AND SPAqNG.
ROOR TOPPING TO BE 3/4" GVPCRETE 2000 OR APPROVED EQUAL CONTRACTOR
TO ADJUST STAIR RISER HEIGHTS AND DOOR HEADER HEIGHTS ABOVE SUB-FLOOR
ACCORDMGLV.
CONTRACTOR TO PROVIDE PAPER FACED INSULATION FOR ALL E%TERIOR WALLS.
PROVIDE TVVEK VAPOR BARRIER ON ALL EXTERIOR WALLS.
ALL WALL AND CEILMG GVPSUM BOARD TO BE SMOOTH FINISH COATING. REFER
TO FINISH SCHEDULE FOR SHEEN.
PROVIDE WASHER AND DRVER HOOKUPS IN ALL UNITS AS REQUIRED TO MEET OR
EXCEED APPLICABLE CODES.
�WELLING UNIT SEPARATION WALLS OF APARTMENT UNITS SHALL BE MIN. ONE
HOUR FlRE RATED CONSTRUCTION.
PROVIDE WOOD BLOCKING SUPPORT AS REQUIRED. INCLU�ING, BUT NOT LIMITED
TO: ALL LOCATIONS FOR GRAB BARS IN ALL UNITS AND AT ALL STAIR RAILS,
SUPPORT FOR SHFATHING EDGES NOT ON FRAMING, KITCHEN WALL CABMETS ON
ALL FLOORS. AND AT TV WALL LOCATIONS.
PROVIDE R-13 (3 %") MIN. ACOUSTIC BATT INSULATION IN ALL DWELLING UNIT
SEPARATION WALLS. IN CEILINGS PROVIDE R-�3 (3 %") MM. ACOUSTIC BATT
MSULATION AT LOCATIONS WHERE OCCUPIED SPACE ABOVE HAS A HARD ROOR
SURFACE. PROVIDE R-09 (5 V2") MIN. PAPER FACEO THERMAL BATT INSULATION IN
EXTERIOR WALLS. PROVIDE R30 (9") MM. IN CEILING ABOVE GARAGES. PROVIDE
R-38 (11") MIN. IN CEILING BELOW ROOF AREAS.
ALL LIVING UNITS SHALL BE CONSTRUCTED TO COMPLV WITH OBC ADAPTABLE
UNIT TVPE "B" REQUIREMENTS, UNLESS DESIGNATE� ADA ACCESSIBLE UNIT TVPE
"A" IN UNITS LOCATIONS SHOWN.
PROVIDE CONTROL JOINTS IN CORRIDOR GVPSUM BOARD CEILWG 30 FEET O.C.
WITH RESILIENT CHANNELS, TVPICAL.
STRUCTURAL MEMBERS SUPPORTING MORE THAN ONE FLOOR SHALL BE
INDIVIDUALLV PROTECTED BV A ONE-HOUR FIRE RESISTANCE RATED ASSEMBLV.
GENERAL NOTES - ACCESSIBILITY
RELEA5E0 FOR CONSTRUCTION IIT B4-C1 - ONE BEDROOM
Suhjec��ocompliancewithallregula�ions LE: i/4°=1�-�°
04 S�a�e antl Local Codes
City of Carmel
�
�{�n„� i,.�a�'
oarE: 03/19/20
�
�� UNIT B4-C2 - TYPE A ONE BEDROOM
A44�1 SCALE: 1/4" = 1'-0"
��, UNIT 64B1 - TWO BEDROOM
A44�1 SCALE: 1l4" = 1'-0"
Y�
7
� a� UNIT B4-C2 - ONE BEDROOM
�4-103 SCALE: 1/4" = 1'-0"
��� UNIT B4-A1 - ONE BEDROOM
A4-101 SCALE: 1/4" = 1'-0"
�i
t.
2.
a.
a.
5.
6.
].
8.
9.
10.
11.
12.
13.
14.
15.
16.
11.
18.
19.
20.
21.
22.
23.
z4
25.
26.
1. THE HEIGHT OF THE WATER CLOSET SHALL BE AT LEAST 15" AN� NO MORE THAN
19" MEASURED TO THE TOP OF THE TOILET SEAT.
2 THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A BRAG BAR OR
HANDR4IL SHALL BE 1.1/4" TO 1-V2".
3. THE STRUCTURAL STRENGTH OF GRAB BARS, BATH TUB SEATS FASTENERS AND
MOUNTWG DEVICES SHALL MEET THE FOLLOWING SPEqRCATIONS
3.1. BENDWG STRESS IN A GRAB BAR OR SEAT INDUCES BV THE MAXIMUM
BENDWG MOMEM FROM THE APPLICATION OF 250 LBF SHALL BE LESS
THAN THE ALLOWABLE STRE55 OF THE MATERIAL OF THE GRAB BAR OR
SEAT.
32 SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BV THE APPLICATION OF
250 LBF SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE
MATERIAL OF THE GRAB BAR OR SEAR. IF THE CONNECTION BETWEEN THE
GRAB BARAND ITS MOUNTING BRACKET OR OTHER SUPPORT IS
CONSIDERED TO BE FULLY RESTftAMED, THEN �IRECTAND TORSIONAL
SHEAR STRESSES SHALL BE TOTALED FOR THE COMBMED SHEAR STRESS,
WHICH SHALL NOT EXCEE�ED THEALLOWABLE SHEAR STRE55.
3.3 SHEAR FORCE INOUCED IN A FASTENER OR MOUNTING DEVICE FROM THE
APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE LATERAL
LOAD OF EITHERTHE FASTENER OR MOUNTING �EVICE OR THE
SUPPORTING STRUCTURE, W HICHEVER IS THE SMALLER ALLOWABLE LOA�.
3.4 TENSILE FORCE INDUCED IN A FASTENER BV A DIRECT TENSION FORCE OF
250 LBF PWS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 LBF
SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL AND THE
SUPPORTING STRUCTURE.
3 5 GR4B BARS SHALL NOT ROTATE WITH W THEIR FITTINGS.
TYPE'B' ACCESSIBLE UNITS
ALL UNITS NOT �ESIGNATED AS TVPE'A' PER BUILOING FLOOR PLAN SHEETS Ai-001 THRU
A1-1p4B
1. PRIMARV ENTRANCE DOOR HAROWARE TO BE LEVER TVPE LOCKING MECHANISM
TO BE ACCESSBLE PUSH BUTTON TVPE PER ANSI 10035
2 ALL THRESHOLDS TO BE V2" MAXIMUM CHANGE M LEVEL FROM TOP OF
THRESHOLD TO FINISHED FLOOR. PATIO SURFACE SHALL BE 4" MA%IMUM BELOW
FLOOR LEVEL OF ADJACENT INTERIOR SPACE
3. TOILET CENTERLINES SHALL BE 18" (MIN.) FROM WALL MEASURED FROM FACE OF
DRYWALL.
4. PRIMARV ENTRANCE DOOR SHALL BE 36" WIDE AND HAVE 18" (MIN.) PULL SIDE
CLEARANCE.
5- INTERIOR UNIT PASSAGE DOORS SHALL BE 34" W IDE (MIN-)-
6. INSTALL BLOCKING FOR FUTURE GRAB BARS AT TOILETS AN� TUBS
��/
��
WOOLPERT
RRCMRECNPEIEH6IXEEPIXGI4E09PRT11L
76351nteractive Way
Suite 100
� Indianapolis, IN
462�8
317.299.7500
FAX: 317.291.5805
F
E
n
r
�.J
�--r
�A`
W
�
Q
�
�
�i\
W
�
�
U �
J•
J �
� UA
�
� Y /
Q O
� �
�
i^' �W
0 �
C �
U�
K
N
m
K
m
❑
N M
� E�
�
mv
� U cp
c
� `O m
ca
� o �
� d �
�� � E
m � `m
�U
Dlssuances:
Proi. No.: 074904
Date: 11/12/18
A Sheet Name:
UNIT PLANS
A4-401
8.�.. a.��. s�� vQ�