Loading...
HomeMy WebLinkAboutA000.1PLOTTED: February 14, 2020 / Prem Kumar / 2975-IN-NAPLES-ET01.DWG A3-ET01 1FB.3English Tudor2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule1901 North Roselle Road, Suite 1000Schaumburg, Illinois 60195Pulte Central ZonePLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Suzette Schuette3/30/2015 GARAGE LEFT 2975-Naples 1815.0000 LOT 25 02/13/2020 SCALE:FRONT ELEVATION1/4" = 1'-0"- ROOF SHINGLES, PER SPEC \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 8" FASCIA, PER SPEC8" FRIEZE, PER SPEC4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC STONE SOLDIER COURSE, PER SPEC 18"x60" SHUTTERS, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC STONE SILL, PER SPEC STONE VENEER, PER SPEC 1214 1214 1214 12141214 1214 1214 1214 FYPON BRACKET #DTLB4X6X5\POR APPROVED EQUAL \A1;3'-6"\A1;MIN. 8:12 8:12 3:12 2650 FX \A1;3'-1"\A1;3'-1" \A1;4'-7{\H0.750000x;\S1#4;}" \A1;5'-5" \A1;3'-0" \A1;4'-7{\H0.750000x;\S1#4;}"\A1;4'-7{\H0.750000x;\S1#4;}" 4:12 \A1;8'-7{\H0.750000x;\S7#8;}"\A1;PLATE HEIGHT FYPON #TRLVL60X30\POR APPROVED EQUAL 4" BATTENS @ 26" O.C. O/ HARDIE PANEL (SMOOTH), PER SPEC +12"+6"+0" 6" FRIEZE, PER SPEC 10" TRIM BOARD, PER SPEC (CUT TO SIZE) 8" COLUMNS w/ SITE BUILT 4X4 BRACKETS 1x2 O/ 12" FRIEZE, PER SPEC 8" FRIEZE, PER SPEC 4" FRIEZE, PER SPEC 4" TRIM BOARD, PER SPEC TOP OF FOOTING 1214 SCALE:ROOF PLAN1/8" = 1'-0"- \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"2986ROOF AREA:SQ. FT. "B"28ROOF AREA:SQ. FT. 14:12 14:12 14:12 \pxi-4,l4,ql,t3;POT VENT\A1;13'-0" \A1;5'-8{\H0.750000x;\S1#2;}" \A1;2'-7" \A1;7'-5" \A1;1'-3" \A1;2'-7" \A1;32'-8"14:1214:12 14:1214:1214:12 14:12 14:12 14:1214:12 8:12 8:12 8:12 14:128:12 \A1;12'-0" 8:12 8:12 3:12 \A1;4'-0" \A1;5'-0" 8:12 14:128:12 3:12 \A1;16'-9" SCALE:LEFT ELEVATION1/8" = 1'-0"- TOP OF PLATE ROOF SHINGLES, PER SPEC WINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPEC 4" TRIM BOARD (TYP.), PER SPECHORIZONTAL SIDING, PER SPECMASONRY WRAP, PER SPEC STONE VENEER, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC\A1;15'-6{\H0.750000x;\S1#4;}" TOP OF PLATE 1x3 OVER 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC 128128128 128 128 \A1;3'-6"\A1;MIN.\A1;3'-1" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC2" FRIEZE, PER SPEC STONE SOLDIER COURSE, PER SPEC STONE VENEER, PER SPEC BLACKOUT WINDOW MASONRY WRAP, PER SPEC 4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPEC SCALE:RIGHT ELEVATION1/8" = 1'-0"- 123 128 128 128 12142030 FX2030 FX 1x3 OVER 6" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC10" FRIEZE, PER SPEC 4" TRIM BOARD, PER SPEC \A1;15'-6{\H0.750000x;\S1#8;}" \A1;3'-6" \A1;7'-1{\H0.750000x;\S1#8;}"\A1;HEAD HT.\A1;3'-1" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;8'-11{\H0.750000x;\S1#2;}" 1214 MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPECHARDIE PANEL (SMOOTH), PER SPEC6" TRIM BOARD (TYP.), PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- 1214 1214 1214 8" TRIM BOARD, PER SPEC 4" TRIM BOARD, PER SPEC\A1;15'-6{\H0.750000x;\S1#8;}"\A1;PLATE HT. ELEVATION ET01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2986 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.98 4.98 4.66 46.89 11 0 AT EAVE 5.97 4.98 5.28 53.11 0 76.00 TOTAL (MIN)9.95 9.95 9.94 100.00 3 HIGH - RIDGE VENT 3.98 4.98 5.00 50.00 0 0 40.00 AT EAVE 5.97 4.98 5.00 50.00 0 72.00 TOTAL (MIN)9.95 9.95 10.00 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 28 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.04 0.05 0.28 80.00 0 1 AT EAVE 0.06 0.05 0.07 20.00 0 1.00 TOTAL (MIN)0.09 0.09 0.35 100.00 3 HIGH - RIDGE VENT 0.04 0.05 0.13 64.29 0 0 1.00 AT EAVE 0.06 0.05 0.07 35.71 0 1.00 TOTAL (MIN)0.09 0.09 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 03/17/20 Mike Sheeks