HomeMy WebLinkAboutS000.5PLAN NAME
SHEET
COMMUNITY NAME
PRODUCTION MANAGER
LAWSON COMMUNITY ID
RELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
SPECIFICATION LEVEL
GARAGE HANDING
REV #
PROJECT TYPENOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
CURRENT
ARCHITECT OF RECORD:ENGINEER OF RECORD:
4/25/13JGF
(c) Copyright PulteGroup, Inc. - 2011
Pulte Central Zone1901 North Roselle Road, Suite 1000Schaumburg, Indiana 60195SINGLE FAMILY
----
----
----
----
----
----
----
----
----
PULTE GROUPMULHERN & KULP
SD.06
\A1;08/05/2013\A1;03/14/2014Indiana DivisionTypical Foundation DetailsSlab on Grade - No Ledge at Porch\A1;04/28/2014
1RECESSED SHOWER @ SLAB ON GRADESCALE: 3/4"=1'-0"
\A1;SEE PLANS
\A1;3 1/2"
\A1;DEPRESS SLAB 3{\H0.7x;\S1#2;}" IN AREA OF SHOWER FOR MUD SET TILE.
\A1;THIN SET CERAMIC TILE AT BATHROOM FLOOR. MUD SET TILE AT SHOWER. NO CURB.
2RECESSED SHOWER @ OPTIONAL BASEMENTSCALE: 3/4"=1'-0"
\A1;SEE PLANS
\A1;3 1/2"
\A1;DEPRESS FLOOR 3{\H0.7x;\S1#2;}" IN AREA OF SHOWER FOR MUD SET TILE.
\A1;THIN SET CERAMIC TILE AT BATHROOM FLOOR. MUD SET TILE AT SHOWER. NO CURB.
FLOOR JOISTS -SEE PLAN
\A1;FRAME-OUT SHOWER AREA ABOVE WITH LSL BEAMS TO MATCH FLOOR SYSTEM DEPTH (SEE PLANS) \A1;2x8 FLOOR JOISTS @ 16" O.C. SET LOW UNDER OPT. SHOWER ABOVE & HANGER TO BEAM AS REQUIRED. (SEE PLANS FOR DIRECTION)
SLOPESLOPE\A1;3 1/2"SLOPESLOPE\A1;3 1/2"
\A1;2x4 LEDGER TO SUPPORT SUBFLOOR @ PARALLEL CONDITION
\A1;2x10 RIM
\A1;2x10 CANT'D. JOIST\A1;X
FASTEN BOTTOM PLATE TO DBL RIM w/ 12d NAILS @ 6" o.c.FLOOR SHEATHING -SEE PLANS
\A1;(2)2x10 RIM. EXTEND EXTERIOR WALL SHEATHING TO BOTTOM OF RIM.
\A1;X\A1;X\A1;X\A1;X\A1;X
\A1;LAP 2x10 JOIST w/\PPOST & FASTEN w/\P(6) {\H0.7x;\S1#4;}" x 4" LONG SDS SCREWS\P(TYP. EA. END)
EXTERIOR WALL BEYOND. SEE PLAN
3SCALE: 3/4"=1'-0"BUMPOUT DETAIL
XX
EXTERIOR WALL STUDS. SEE PLAN
POST\P-SEE PLAN\A1;2x10 JOIST. LAP w/ POST & FASTEN w/(6) {\H0.7x;\S1#4;}"x4" LONG SDS SCREWS \P(TYP. EA END)
(2)2x10 P.T. RIM.SIMPSON HUC210-2\PCONCEALED FLANGE HANGER (TYP.)
SCALE: 3/4"=1'-0"PLAN X-X
SHEARWALL EDGE NAILING PER SPECS\A1;FOUNDATION OR FLOOR SYSTEM BELOW\P-SEE PLANS
YY
\A1;1'-6"\P(MAX.)
SIMPSON H2.5A CLIP
\A1;SIMPSON A34 CLIP FASTENING 2x10 CANT'D TO DOUBLE STUD
THIS DETAIL IS LIMITED TO A 9'-0" WIDE BAY WINDOW SEAT
EXTERIOR WALL STUDS. SEE PLAN
\A1;2x6 FLAT STUD FASTENED TO POST w/ {\H0.7x;\S1#4;}"x4" LONG SDS SCREWS @ 12" O.C.
(2)2x10 P.T. RIM.SIMPSON HUC210-2\PCONCEALED FLANGE HANGER (TYP.)
SCALE: 3/4"=1'-0"PLAN Y-Y
POST\P-SEE PLAN
SHEARWALL EDGE NAILING PER SPECS
\A1;CRIPPLE WALL BEYOND
PLOTTED: June 3, 2015 / Andrew Moore / IND CENTRAL ZONE - MASTER FOUNDATION DETAILS - NO LEDGE.DWG
P:\Client Files\125 - Pulte Central Zone\Master Client admin\Master Details\Central Zone Master Fnd Detail Files\IND Central Zone - Master Foundation Details - No Ledge.dwg, 6/3/2015 11:30:31 AM, DWF6 ePlot.pc3
03/19/20
William Hohlt