HomeMy WebLinkAboutA006-ConstructionPlanEXIlAUST DUGT DOWN
��2
LOUNGE
� �
� �
� �
� DUQ I DUCT � �l4'T p�G7F�M W=T � I pEDICURE
\%
� � � � � �f14� � � I SPHCE
�3 J
— —
—
� ° � Fz 120
� I q„ NAIL SALON
C
�� O
� 4�_��� 4�_��� nzi
A�.I
___J � I /�
I I o � �)..(,�q�//J
2 v /!/ LJ
I FI �
��—���� A�.I �
M
Alo.l erunusr eruws
DUQ DUCf
1
_ _ _ _ _ _ _ _ _ _ _ _ _ �
I 6�_��� � 6�_��� �� � � I
5 _�Ou
NOLD TO GYP
59 _�0°
0
a
�
v
�
6'-4 V2" 5'-10" I'-5" 12'-0"
NOLD TO GYP.
100
SALES
CONSTRUCTION PLAN
I. FLOOR TRENCN FOR NEW SANITARY CONNECTION. SEE FLUMBING DRAWINGS AND SLAB CUTTING NOTES.
2. FLOOR TRENCN FOR NEW SERVICE DESK ELECTRICAL. SEE ELECTRICAL DRAWINGS AND SLAB CUTTING NOTES.
4'"FCO
n
A'!.I
IXHAUST DULT _
�WWN / THRGUGH
WALL.
5�_�0" ��u — 5�_�Du
FJOLG TO GYP. NOLD TO GYP.
I2 _0
c4 a� �.2/cz
�� 12I
C3
iII SHELF
I`� j 12
I 12 I D4
10
D3 q7,2 DI
- �--
_ �
AI �5 _3"
10'_0" —
R
A'/.I
N
��isTw� nAsoNRr PaRririoN O e; isriNG PnRririoN
z
�
�
�
0 NEW P�iRTITIQN �
PARTITION LEGEND "°TT°S°A`E C
SSI=STUD
SIZE
GA=GAUGE
rvPe LOCATION SSP=STUD CONSTRUCTION
SPACING
�Q.C.)
WI=WIDTH
551 =' 4 A OUSTIC� BAT TYPE T O YAND �GAEGESA 0 4 FOROBOX ABOVE.
„ SIDE ONE 5/8' 'X' YP BD. RUN TIGFIT -0
GA 20 �� � � EILING- MSTAL
AI SALES WALL SSP 2° COMPONENT CONSTRUC ION B�M/POST
WI - 7 I/4"
SIDE ONE: WC-3 BRICK SIDING TO I4'-0° SEE N/AIO.I.
551 - 6" SIDE TWO� NONE. SEE SNEET AI0.4 FOR BOX BEAM/POST COMPONENT
A2 SALES WALL GA - 20 CONSTRUCTION AND GAUGES.
cJCJP — 2Qn
WI — 7 I/Qn
551 — 6" EACF! SIDE: 5/8" TYPE 'X' GYP- BD. RUN TO 6" ABOVE CEILWG. SEE
A, INTERIOR GA — 20 SNEET AI0.4 FOR BOX BEA�1/POST C0�1PONENT CONSTRUCTION AND
PARTITION SSP — 24" GAUGES.
WI � % ��41i
551 - 6° EACN SIDE 5/8" TYPE 'X' GYP. BD. TO 8'-0" APF
PARTIAL NEIGIIT GA -20 GA REFER TO DETAIL G/AIOA POR STUD GAUGE, SPAQNG, AND SUPPORT
Aq DISPLAY WALL SSP -2q"
WI - 7 I/q
551 - 6" SIDE ONE- WC-3 BRICK SIDMG TO I4'-0° SEE N/A101
AS PARTIAL FIEIGNT GA -20 SIDE TWO� g' TYPE 'X' GYP. BD TO Iq'_0"
PERIf11TER SSP -24" SEE SNEET AIOA FOR BOX BEAI7/POST COMPONENT CONSTRUCTION
WI - 7 I/4" AND GAUGES.
551 - 6"
PAR?IAL NEIGN? GA -20 EACN SIDE: e" TYPE 'X' GYP. BD TO Iq'_0"
A6 PERIMITER SSP -24" SEE SNEET AI0.4 FOR BOX BEAM/POST COMPONENT CONSTRUCTION
WI - 7 I/4" AND GAUGES.
551 - 3 5/8° EACN SIDE� 5/8" TYPE 'X' GYP. BD. RUN TO 6" ABOVE CEILING.
B� IN?ERIOR GA - 20
ARTITION SSP - 2q"
NOR7H �� � nPE
�� WI - 4 7/8
551 - 3 5/8" SIDE ONE: 5/8" ?YPE 'X' GYP. BD. RUN ?0 13'-0" APF.
� B2 INTERIOR GA - 20 SIDE TWO: 5/8' 'X' GYP. BD. RUN TO 6" ABOV CEILWG-
PARTITION SSP - 24" MSTALL ACOUSTIC BATS TO q'-0"
WI - 4 7/8"
0 2� 4� B� G
EACN SIDE 5/8" TYPE 'X' GYP. BD. RUN 13'-0" A.EF.
B3 INTERIOR G 3 208�� BR DOWNORIZONTALLY AT 6'-0" O C. ? EXTERIOR WALL ABOVE
PARTITION SSP - 4"
L PROVIDE W-WALL BLGCKING WNERE REQUIRED. SEE TNIS PLAN CGDED NOTE 10 AND ELEVATIONS SNEET ALI � WI _ q 7°
A7 2
�
H
�
K
a
� o
W N
� O
� N
N
W �
¢ N
o �
w
N
�
� >
J
W � mry
� � W W r�
3 NUU� �
O���v o
N�rtz >
� � W ��w �
�ViOJJK `°
W �UUU 3
r
Z �
� �
w
�
� E ONE: 5/8" GREEN B RD BENIND FRP OR WALL COVERING, RUN
3. FLOOR TRENCN FOR NEW WAXIN� TABLE FLOOR OUTLET. SEE ELECTRICAL DRAWINGS AND SLAB CUTTING MTERIOR 551 - 3 5/8° TO " ABOVE CEILING
NOTES PARTITION W/ GA - 20 SIDE T � 5/8° T E'X' GYP. BD. RUN TO 6" ABOVE CEILING.
Q WqLL COVERING SSP - 16° SIDE TWO A OR'S GLOSET)�� 5/8" GREEN BOARD BENIND FRP, RUN
4- .. - OR PRP WI - 4 7/8° TO 6" ABOV ILING
5. SEE SNEET A10.4 FOR BOX POST AND BEAM FRAI7ING � �
MTERIOR 551 - 6" SIDE NE: 5/8' GRE BOARD BE411ND PRP OR WALL COVERING, RUN
6. EXISTING SANITARY MAIN TIE IN POMT. COORDINATE WIT41 PLUMBING. C2 PARTITION W/ GA - 20 T 6" ABOVE CEILING-
WALL COVERING SSP - 16" SIDE TWO: 5/8' GREEN BOA BENIND FRP OR WALL COVERING, RUN Q..i
Z EXISTWG SANI?ARY_ VERIPY IN PIELD- OR PRP WI - 7 I/ TO 6" ABOVE CEILMG. �
SIDE ONE 5/8° TYPE 'X' GYP. BD., IGNT TO STRUCTURE ABOVE (OR O
8_ PEI"rtlR ��BAR vvPifl2E vd#�� bv#5 BEM6ti5bEB z i i�EF'#RE �2R �dfbd i t.^.2i: 6Sv'EGII'v'v S - I I/2" TO 6" ABOVE FINISNED CEILING WI-IER XISTING� OVER I V2" I�IETAL
Norroscn�e p� FURRED MASONRY GA - 20 FURRING CNANNELS AT 24" O.C. (RUN VE ICALLY) ON MASONRY �i
q. ���T=�-«��F�E�-�-=^�' ` ^��� GENERAL NOTES F wa�� ssP - za wa��. (>
� �� �� .� �� �. � wi - z va" sioe Two: NONe �
10. PROVIDE IN-WALL BLOCKING FOR ALL WALL MOUNTED ITEMS. SEE INTERIOR ELEVATIONS FOR ALL ITEMS
REQUIRING BLOCKING L CONCRETE REPLACEMENTS SUCN AS TRENCN POURBACKS SNALL BE SQUARED OFF QEANLY, FLUSN WITN TNE � �
SURROUNDING AREA AND DOWELEC WTO TNE ADJACENT SLAB. PLACEMENT PRCCE55 TO BE IN ACCORDANCE 551 - 3 5/8" SIDE ONE: 5/8" TYPE X' GYP. BD., TIGNT TO STRUCT E ABOVE (OR
II. REFER TC INTERIOR ELEVATIONS, SECTIONS, ANC DETAILS FOR HOW TO ROUTE DUCT WORK INSIDE WALL c TO 6" ABOVE FINISHED CEILING WNERE EXISTING) OVER 3 8 METAL C%l
CAVITIES WITN SECTION 3= OPOUR BACK NOTES'. OVERCUTTING POUR BACK WILL RESULT IN A CNARGE BACK FOR D2 P RED WALL / GA - 20 57UD5 AT 24" O.C. PURRING STUDS NELD TIGNT ?0 EXIS?I WALL �
OVERLAYMG TNE FLOOR. FRAI7EG CGRNER SSP - 24" SIDE TWO: NONE Q
12. ALL WALLS SURROUNDING WAXING ROOM TO F1AVE BATT INSULATION INSTALLED IN WALL FROM FlNISFI FLOOR 2. EXISTING ANCNOR BOLTS, CONDUIT, PIPES, AND SUCN PROTRUDING OUT FROM TNE SLAB SNALL BE WI - 4 I/4" U
TO 6" ABOVE WAXING ROOM CEILING. RECESSED A MINIMUM OF '/."BELOW TNE SLA.B SURPACE PRIOR TO POLISFIING. SIDE ONE= 5/8" TYPE 'X' GYP- BD- TO 6" ABOVE CEILMG-
551 - 6" ' �o�nnnn,v
J SIDE TWO: NONE ,.s�`oGsoEsqti�,,,,
13. OFFSET IN-WALL DUCT LIGNTLY TO MI55 CENTER LEG SUPPORT OF BENCN. COORCINATE WITN ELEVATIONS 3. POUR BACK NOTES: FURRED GA - 20 ,��'�.;� „�.m.,,
D3 =i,:e Fo•.,s,,
AND PIXTURE DRAWINGS. PARTITION SSP - 2q" _ . _
a. MIX SNALL BE MINIMUM 3,000 P51 WI - 6 5/8" '��`�`��= _
14. EXISTING SANITARY FLOOR CLEAN-OUT TO REMAIN. VERIFY IT IS FLUSN WITFI SLAB = sro-+eor f.-
b. DO NOT USE FLY ASN� GROUND GRANULATED BLAST FURNACE SLAG OR AIR-ENTRAINING AD MIXTURES '%�`'��.aro�awy' '
SIDE ONE: 5/8" TYPE 'X' GYP. BD., TO NEIGNT SNOWN IN ELEVATIONS "a„?ACHi1Ec�,,."°�
15. WATER HEATER ON CONCRETE CURB. SEE PLUMBING DRAWINGS c. ADMIXTURES SNALL NOT BE CALGUM CNLORIDE-BASER SSI - 6" "������^°°
SIDE TWO: NONE znvzozo
r
m
0
w
Y
U
w
_
U
>I
m
z
¢
�
0
d. NOf11NAL MAXIMUM COARSE AGGREGATE SNALL BE '/a" D4 FURRED WALL GA - 20
I6. FLOOR DRAIN - SEE PLUMBING DRAWINGS SSP - 2q"
e. FIBER MESN NOT PERMITTED. WI - q I/q" '
17. W41EN TRENCNING MAKE SURE TO NOT IMPACT SANITARY LINE. q. CONFIRM ALL FLOOR CUT LOCATIONS WITN DSW PM PRIOR TO CUTTING. ,
SIDE ONE: 5/8' GYP �F^��TM��e������� �PP�=^aE���F a
RELEA5E0 FOR CONSTRIICTI�N 5. sEE Giaio.i FOR s�ae PouR sacK oETai� _ 6 ��a si�E rwo: NONE "re`�=""."°."`_.`.`��`_""°°.`R" �
D5 FURRED WALL GA — 20 NO , SEE N/AI0.1 ARCH JOB # 2019.050 -
Su6jecuocompliancewlthallregula�ions 6. GC TO CONFIRP1 WITN LL DURING BIDDWG IF AN XRAY OF TNE SLAB IS RE(:�UIRED. GC TO WCLUDE PRICE IN SSP — 24" DRAWINGNUMBER: �
otS�a�eantllocelCodes PROPOSAL IF REQUIRED. _ � ��2�� �
City of Carmel w
" , "°TT°5°A`E M SLAB CUTTING NOTES "°TT°5�"`E E PARTITION SCHEDULE "°TT°5°A`E /� �.1 �
�{�n„� i,.va�1_
DATE: 03�20�20