Loading...
HomeMy WebLinkAboutA015.5-SpecificationsDIVISION 09� FINI541E5 SECTION Oq 21 16 - GYPSUM BOARD ASSEMBLIES A. PRODUCTS/MANUFACTURERS= USG, GEORGIA PACIFIC, OR NATIONAL GYPSUM. B_ GENERAL: PROVIDE GYPSUM BOARD SYSTEMS WCLUDING METAL FRAMING ACCESSORIES, GYPSUI'1 BOARD, JOWT TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION_ C. STANDARDS- COMPLY WITN ASTM C754 AND ASTM C840, AND REQUIREMENTS POR PIRE RATINGS_ I. DEFLECTIONS- MAXIMUM L/240 TYPICAL, L/360 AT LOCATIONS INDICATED TO RECENE TILE. D. FIRE-RATED ASSEMBLIES: LISTED BY UNDERWRITER'S LABCRATORY, GYPSUM ASSOQATION I. (GA) FlLE NO'S IN GA-600 PIRE RESISTANCE DESIGN �1ANUAL OR OTNER LISTING APPROVED BY APPLICABLE AUT4JORITIES. E. SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS I'1ANUFACTURED BY OR RECOMMENDED BY MANUFACTURER OF GYPSUM BOARD TO MAINTAIN SINGLE-SOURCE RESPCNSIBILITY FOR SYSTEM. F. METAL FRAMING- CONFORM TO ASTM C754; COMPLETE I6 GAGE AND LIGNTER STEEL FRAMMG AND SUSPENSION SYSTEM FOR GYPSUM BOARD SYSTEMS_ PROVIDE ACCESSORIES REQUIRED FOR COI'1PLETE WSTALLATION. I. WSTALL OWNER PURNI54JED GARCY STUDS AND STANDARDS. PROVIDE ACCESSGRIES AS REQUIRED FOR C01"IPLETE WSTALLATION. 2. MANUFACTURED SUSPENSION SYSTEM SUC4J AS G4JIGAGO METALLIUDRYWALL SYSTEM IS AGCEPTABLE. G. GYPSUI'1 BOARD: CONFORI'1 TO C840; UL LISTED FIRE RESISTANT GYPSUf'I BOARD TNROUGNOUT. I_ STANDARD� ASTI'1 C36, 5/8" TNICK 2. GORE BOARD= ASTM C442, I" T4JIGK. H- GYPSUI'9 BOARD ACCESSORIES: COFIPLY WITN ASTf'I C840_ I. PROVIDE PROTECTIVE COATED STEEL CORNER BEADS AND EDGE TRIM; TYPE DESIGNED TO BE CONCEALED IN RNISNED CONSTRUCTION BY TAPE AND JOMT C01'1POUND. 2. CORNER BEADS: MANUFACTURER'S STANDARD METAL BEADS. 3 REINFORQNG TAPE, JOINT C01"IPOUND, ADNESIVE, WATER� FASTENERS: TYPES RECOMMENDED BY SYSTEM MANUFACTURER AND CONFORMING TO ASTM C475. 4. CONTROL/EXPANSION JOINTS: 2-PIECE DRYWALL JOINTS; DESIGN TO BE FINISNEG TO ADJACENT SURFACE WITFI TAPE 4 SPACKLE AT 30' CENTER TO CENTER L PIRE RATED CONSTRUGTION: GOMPLY WITN UNDERWRITER'S LABORATORIES CERTIFIED FIRE TESTS AND APPLICABLE CODE REQUIREI'�ENTS. L SNAFT WALL SYSTEM= PROVIDE AT SFJAPTS AND WFJERE INDIGATED. 1 ACOUSTICAL ACCESSORIES: PROVIDE ASTI'1 C665, TYPE I ACOUSTICAL INSULATION AND ASTM C919 PAINTABLE ACOUSTICAL SEALANTS WLIERE ACOUSTICAL SYSTEMS ARE INDICATED. K. MSTALLATION: C01'1PLY WIT41 I'1ANUFACTURER RECOI'1MENDATIONS, REFERENCED AND APPLIGABLE REQUIREMENTS FOR RRE RATINGS AND ACOUSTICAL RATINGS. I. SPEGAL I'1ETAL STUD AND GYPSUI'1 DOOR: PROVIDE SPEQAL CONFIGURATION AS INDICATED. L. METAL FRAMING ERECTION�. ERECT I'9ETAL FRAMING IN ACCORDANCE WITN ASTM C754 AND I'1ANUPACTURER'S RECOI'1F�ENDATIONS. I. DOOR OPENING FRAMING- MSTALL DOUBLE STUDS AT DOOR FRAME JAMBS. I"I_ CEILMG PRAI"IING WSTALLATION: ERECT IN ACCORDANCE WIT41 ASTf1 C75A AND I'1ANUFACTURER'S RECOI'11'1ENDATIONS. REMFORCE OPENINGS IN CEILING SUSPENSION SYSTEM. I. LATERALLY BRACE ENTIRE SUSPENSION SYSTEf'I_ RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 03�20�20 N. GYPSUM BOARD MSTALLATION= INSTALL IN ACCORDANCE WIT41 ASTI"I C840 AND I'1ANUPACTURER'S RECOMPIENDATIONS. USE SCREWS POR PASTENING GYPSUI"I BOARD TO FURRING AND FRAMING- I. FOR FIRE RATED SYSTEI'15 C01'1PLY WITFI REQUIREI'1ENT5 FOR FlRE RATINGS_ 2 PLACE CCRNER BEADS AT EXTERNAL CORNERS. USE LONGEST PRACTICAL LENGTNS 3. PLACE EDGE TRIM W4JERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 4- TAPE, FILL� AND SAND EXPOSED JOINTS, EDGES� CORNERS AND OPENMGS TO PRODUCE SURFACE READY TO RECEIVE FINISLIES. FEATNER COATS ONTO ADJOINWG SURFACES. 5. FINISNING- COMPLY WITN GYPSUM ASSOCIATION (GA) "LEVELS OF GYPSUM BOARD PINISN" GA LEVEL 4 CONSISTING OF I COAT USG-I PRIMER AND 2 COATS OP PINISN PAMT. PROVIDE FLUSN, 51"IOOTN JOMTS AND SURFACES READY FGR APFLIED PAINT FINISNES. 6. REI'�OVE AND REPLACE DEFECTIVE WORK. O. ACOUSTIGAL ACCESSORIES MSTALLATION. I. PLACE ACOUSTICAL WSULATION TIG41T WITWN SPACES� AROUND CUT OPENINGS, BEl11ND AND AROUND ELEGTRIGAL AND MEGFJANICAL ITEMS WIT4JIN PARTITIONS, AND TIGNT TO ITEMS PASSING TNROUGN PARTITIONS_ 2. PLACE ACOUSTICAL SEALANT WITNIN PARTITIONS IN ACCORDANCE WITN MANUFACTURER'S RECOMMENDATIONS.INSTALL ACOUSTICAL SEALANT AT GYPSUM BOARD PERIMETER, AT BASE LAYER AND FACE LAYER OF GYPSUM BOARD, AND PENETRATIONS OF PARTITIONS. 3. TOLERANCE� MAXIMUM I/4" SPACE BETWEEN GYPSUM BOARG AT FLOOR, CEILING, AND PENETRATIONS. 4. INSTALL ELECTRICAL BOX PADS WITN PADS MOLDED AND PRESSED ON BACK SIDE OF BOX, CLOSING OPENINGS, IN ACCORDANCE WI?N MANUPACTURER'S INSTRUCTIONS, FOR COMPLETE ACOUSTICAL BARRIER. SEGTION 09 30 00 - TILE A_ TILE PRODCUTS/I'�ANUFACTURERS�. AS INDICATED ON DRAWINGS_ L FLOOR TILE- PROVIDE NON-SLIP UNITS WITFJ MINIMUM WET AND DRY VAWE OF 060 COEPRQENT OF PRICTION WNEN TESTED IN ACCORDANCE WITN ASTM CI028. B. GENERAL: PROVIDE TILE SYSTEMS MCLUDING SETTING MATERIALS, GROUT, AND ACCESSORIES AS REQUIRED FOR C01'1PLETE FlNISNED INSTALLATION. C. STANDARGS: COMPLY WITN TILE COUNQL OF AMERICA "NANDBOOK OF CERAMIC TILE MSTALLATION" INCLUDING REFERENCED ASTM AND AN51 STANDARDS. D. LATcX TNIN SET: TNINSET BOND COAT, LATEX-CEMEN?ITIOUS MOR?AR CONFORI'�ING TO AN51 AlIBA_ E_ GROUT�� ANSI AII86 C AI36J, LATIX CEf'IENTITIOUS TYPE BY POLYBLEND BUILDING PRODUCTS AND ACRYLIC ADFIESNE MAPEI TYPE I. GROUT JOINT I/4" MAX OR AS NOTED ON PINISN SCNEDULE COLOR AS INDICATED IN TNE MATERIALS SCNEDULE. E INTEGRAL WATERPROOFMG: LATICRETE, BOSTIK, OR NOBEL LIQUID RUBBER MTEGRAL TILE SETTING WATERPROOFlNG SYSTEI'1 WIT41 NO BITUI"IINOUS EXTENDERS. PROVIDE AT FLOOR TILE APPLICATIONS ABOVE GRADE AS REQUIRED. G. QEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT I'�ANUFACTURERS. N. PREPARATION: DO NOT COMMENCE WORK UNTIL SURFACE CONDITIONS ARE WIT4JIN TOLERANCES REQUIRED FOR PROPER INSTALLATION_ APPLY LATEX LEVELING MATERIAL WNERE REQUIRED TO MEET TOLERANCES. I. MSTALLATION= COMPLY WITN TILE GOUNGIL OP AMERICA (TGA) NANDBOOK FOR CERAI'91C TILE INSTALLATION POR LATEX BOND COAT TNIN SET APPLICATION_ I. TILE- MSTALL TILE IN ACCORDANCE WIT4J REFERENCED AN51 STANDARDS AND ?CA RECOMMENDA?IONS POR TYPE OF SUBSTRA?E AND INDICATED SETTING MET410D. 2 FLOOR TILE WSTALLATION METNOD: TCA METNOD PII3. 3. FLOOR TILE INSTALLATION I'1ETFIOD ON ABOVE GRADE SLABS: FI22. 4. WALL TILE INSTALLATION METNOD� W243. 5. PLACE TILE IN ACCORDANCE WITFI PATTERNS INDICATED ON DRAWINGS OR AS DIRECTED BY OWNER'S PROJECT �1ANAGER. CAREFULLY PLAN TILE LAYOUTS AND ENSURE PATTERN IS UNINTERRUPTED FROM ONE SURFACE TO TFIE NEXT AND TFIROUGFI DOORWAYS. 6. SEAL TILE AND GRGUT SURFACES. SEGTION 09 51 00 - ACOUSTICAL CEILIN65 A_ PRODUCTS: ACOUSTICAL UNITS: TYPES AS INDICATED ON DRAWINGS. MANUPACTURERS� ARMSTRONG OR APPROVED EQUAL. I. FISSURED CORTEGA I'�INABOARD tt76q� 24"XAS°X5/8"� SQUARE CUT, NON-DIRECTIONAL, (WF11TE ON WFIITE) WIT4J 15/16" PRELUDE GRID AND LOCK-DOWN CLIPS IN VESTIBULE ONLY. 2 FOR ARMSTRONG #769 CBLING= ARMSTRONG PRELUDE XL 15/16° EXPOSED TEE WITN EDGE TRII"I AND F10LD-DOWN �LIPS IN VESTIBULE ONLY 3. SUSPENSION SYSTEM= TYPE AS INDICATED ON DRAWINGS. MANUFACTURERS- ARMSTRONG. a. FOR ARMSTRONG tt769 CEILING- ARMSTRONG PRELUDE XL 15/I6° EXPOSED TEE WITN EDGE TRIM AND NOLD-DOWN CLIPS IN VESTIBULE ONLY. B_ GENERAL. PROVIDE ACOUSTICAL CEILINGS INCWDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISNED WSTALLATION. C. STANDARDS: CONFORf'I TO ASTP'I C635 FOR !"IETAL SUSPENSION SYSTEI'9 AND ASTM C636 FOR WSTALLATION OF AGOUSTIGAL GEILINGS. C. PERFORI"IANCE REC:IUIREMENTS�. PROVIDE PRGDUCTS LISTED BY UNDERWRITERS LABORATORIES (UL). L FLAME SPREAD/SMOKE DENSITY� PROVIDE FRODUCTS MEETING CODE REQUIREf'IENTS FOR f'IAXIf'IUI'1 25 FLAI"IE SPREAD AND I'1AXII'9Uf'I 25 SI'10KE DENSITY. E SEISMIC REQUIREMENTS: COMPLY WITN STATE AND LOCAL CODE REQUIREMENTS FOR SEISMIC BRA,CING OF CEILING SUSPENSION SYSTEI'"I, AND WITN ASTI'1 E580. F. WSTALLER= FIRM WITFJ MINIMUM TNREE YEAR'S SUCCESSFUL EXPERIENCE IN PROJECTS OF SIMILAR TYPE AND SCOPE; ACCEPTABLE TO MANUFACTURER OF ACOUSTICAL UNITS. G. PROJECT CONDITIONS: DO NOT INSTALL CEILINGS UNTIL BUILDING IS ENCLOSED, SUFFlQENT FIEAT IS PROVIDEG, DUST GENERATING ACTIVITIES NAVE BEEN COMPLETED AND OVERFJEAD MECFJANICAL WORK IS COMPLETED, TESTED AND APPROVED. ALLOW WET WORK TO DRY PRIOR TO INSTALLATION. F1. PREPARATION= MEASURE CEILMG AREA AND ESTABLISN LAYOUT OP ACOUSTICAL UNITS TO BALANCE BORDER WIDTNS AT OPPOSITE EDGES OF EACN CEILING- DO NOT USE LESS T4JAN FIALF WIDTFI UNITS AT BORDERS. COORDINATE WITFI OTNER WORK SUPPORTED BY OR PENETRATING TNROUGFJ CEILINGS, MCLUDING LIGIJT FIXTURES� FIVAC EQUIPMENT AND PARTITION SYSTEI'1S_ I. WSTALLATION= COMPLY WIT4J MANUFACTURER REGOMMENDATIONS, ASTM C636, AND APPLICABLE REQUIREMENTS POR FIRE RATINGS_ L FINISNED CEILINGS- TRUE TO LMES AND LEVELS AND FREE FROM WARPED, SOILED OR DAMAGED GRID OR ACOUSTICAL UNITS. 2. INSTALL CEILING SYSTEI"IS IN A MANNER CAPABLE OF SUPPORTING SUPERIMPOSED LOADS, WITN MAXIMUM PERMISSIBLE DEFLECTION OF I/8" IN 10'_0" 3. ENSURE SUSFENSION SYSTEM IS LOCATED TO ACCOMMODATE FITTINGS AND UNITS OF EQUIPFIENT WFIICN IS TO BE PLACED APTER INSTALLATION OP GBLING GRID. 4. WNERE DUCTS OR OTNER EQUIPI'1ENT PREVENT REGULAR SPAQNG OF 4JANGERS, REMFORCE NEAREST ADJACENT NANGERS AND RELATED CARRYING CNANNELS AS REQUIRED TO SPAN REQUIRED DISTANCE. 5. INSTALL EDGE �10LDINGS AT WTERSECTION OF CEILING AND VERTICAL SURFACES, USING MAXIMUM LENGTNS, STRAIGFIT, TRUE TO LINE AND LEVEL; I"IITER CORNERS. 6. FIT ACOUSTIC UNITS IN PLACE, FREE FROM DAMAGED EDGES OR DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION_ LAY DIRECTIONALLY PATTERNED UNITS ONE WAY WITN PATTERN AS DIRECTED. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURPACES. 7. INSTALL UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS. 8_ WSTALL HOLD-DOWN CLIPS WNERE REQUIRED BY APPLICABLE CODES AND W4JERE GEILING IS wITF1M 20'-0" OP AN EXTERIOR DOOR. J. ADJUSTI"IENT�. ADJUST SAGS OR TWISTS WFIICFI DEVELOP IN �EILING SYSTEI'1 AND REPLACE ANY PART WNICN IS DAMAGED OR FAULTY. SEGTION 09 68 00 - GARPET A_ PRODUCT/I'�ANUPACTURERS: S41AW CARPET TILES AS INDICATED IN DRAWINGS_ B. GENERAL= PROVIDE CARPET AGCESSORIES AS REQUIRED POR COMPLETE PIN154JED INSTALLATION. C. STANDARDS: C01'1PLY WIT41 CARPET AND RUG INSTITUTE (CRI) STANDARDS. D. WSTALLER QUALIFICATIONS: APPROVED BY CARPET MANUFACTURER. UPON REQUEST, SUBI'�IT LETTER FRGI'� CARPET f'IANUFACTURER STATING INSTALLER IS ACCEPTABLE. E. WARRANTY- PROMPTLY REPAIR OR REPLACE CARPET WFJICFJ EXNIBITS EVIDENCE OF DEFECTIVE MATERIALS OR WORKMANSl11P- WARRANTY PERIOD TWO YEARS_ F. TYPE= FURNISHED BY OWNER AS INDICATED ON T4JE FIN1511 SCNEDULE. G- ADNESIVE�� NONTOXIC TYPE RECOMMENDED BY CARPET AND UNDERLAY MANUFACTURERS TO SUIT APPLICATION AND EXPECTED SERVICE. L LEVELWG AND RAMPMG MATERIAL�� LATEX-CEMENT MATERIAL DESIGNED FOR PROVIDING TWN SOLID SURFACE FOR LEVELING AND F11NGR RAI'1PING OF SU65URFAGE TO ADJAGENT FLOOR FINISFJES. USE MATERIAL CAPABLE OF BEING APPLIED AND FEATNERED OUT TO ADJACENT FLOCR WITNOUT SPALLiNG. N_ TRANSITION STRIPS: AS INDICATED ON TNE DRAWINGS AND MATERIALS SCFIEDULE. L PREPARATION: CLF1aN FLOORS OP DUST, DIRT, SOLVENTS, OIL, GREASE, PAWT, PLASTER AND GTFIER SUBSTANCES DETRII'1ENTAL TO PROPER PERFORMANCE OF AD4JESNE AND CARPET. ALLOW FLOORS TO TFJOROUG4JLY DRY. I. USE LEVELING AND RAMPING MATERIAL TO PATCN CRACKS, SMALL NOLES, LEVELMG AND FOR RAI'1PING TO PROVIDE FINISFIED CARPET WITWN V2" OP AD�ACENT FLOORING MATERIALS. J. CARPET WSTALLATION�.INSTALL CARPET IN ACCORDANCE WITN CARPET MANUFACTURER RECOMMENDATIONS AND MSTALLATION MSTRUCTIONS. L PRIME SUBSTRATE IF REQUIRED AND AS RECOMMENDED BY MANUFACTURER- SPREAD ADNESIVE IN QUANTITY RECOMMENDED BY �1ANUFACTURER TO ENSURE PROPER ADNESION OVER FULL AREA OF INSTALLATION. 2. APPLY ONLY ENOUGN ADFIESIVE TO PERF�IT PROPER ADFIESION OF CARPET BEFORE INITIAL AD4JESIVE SET. K TRANSITION STRIPS: INSTALL IN ACCORDANCE WITN MANUFACTURER'S RECOI'1FIENDATIONS AND INSTALLATION INSTRUCTIONS. SEGTION 09 77 00 - PREFINISNED FIBERGLASS WALL PANELS (F.R.P.) A. PROCUCTS/MANUFACTURERS- MARLITE. B. GENERAL� PROVIDE PREFINISNED GLA55 FIBER REWFORCED PGLYESTER RESIN FABRIGATED WALL PANELS, WITN TRIM PIECES AND ACGESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. C. PANELS: FIBERGLA55 REINFORCED PLASTIC (FRP) PANEL SYSTEM; NOMINAL O.OqO" TNICKNE55; WNITE. L PIRE-RATING= CLA55 I(UL CLA55 A), MAXIMUM 25 FLAME SPREAD, 25 SMOKE GENERATION BASED ON ASTM E84. D. WORK ROOM ONLY: TRIM PIECES: MANUFACTURER'S STANDARD MATCNING MOLGINGS AND TRIM PIECES AS REQUIRED FOR COMPLETE, FINISNED WSTALLATION, AND AS REQUIRED POR JOINTS, CORNERS AND PANEL EDGES SALON FRP-2 SUBWAY TILE. TRIM WITH PAINTED WOOD PER DRAWINGS. JOINTS TO BE COMPLIMENTARY RLLER PER MARLITE. NO TRIM PIECES AT JOINTS E. ADNESIVE- LOCTITE PL 200 OR MANUFACTURER'S RECOMMENDEG NONTOXIG, WATERPROOF ADNESNE SUITABLE FOR SUBSTRP,TES INDICATED. P. PRIMER: PROVIDE NON-STAINING RELEASE COAT PRIMER AS RECOMMENDED BY WALL PANEL MANUFACTURER WNERE PANELS ARE APPLIED TO GYPSUM BGARD. G. MECNANIGAL FASTENERS: CONCEALED TYPE ONLY; TYPES AS RECOMMENDED BY WALL PANEL MANUFACTURER. N. WSTALLATION: COMPLY WITFI MANUPACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS POR PIRE RATWGS_ COPE AND MITER TRIM PIECES. INSTALL PANELS IN MAXIMUM SIZE WCREMENTS AVAILABLE. I. INSTALL WALL PANELING BEPORE INSTALLATION OP PLUI'981NG, BASES, NARDWARE, AND SIMILAR ACGESSORIES. 2 ADNESIVELY APPLY PANELS TO WALL SURFAGES. SUPPORT PANELS IN PLACE AS REQUIRED UNTIL ADNESIVE DRIES. EXPOSEG MECNANICAL FASTENERS ARE NOT A�GEPTABLE. REMOVE EXCE55 ADNESIVE FRCM EDGES AND WIPE SEAM CLEAN WITN DRY CLGTN TOWEL. m � � a � Z 0 > � � o W N � O � N N w � Q N o � w N � � j J � w O mN o Q NUU� z 3 N��Z � �/� w www- � V J � ~ ~ w � v=i 0¢�� m � W �UUU 3 n Z � � � N w � z � U � U a C/� �`OpcLO55A r°�v�`-��sr@' �'T`�. c:�.'P4 qg0`0S%� _ ,' p��9•. : %�� �STA�EOF . � �1., !NUTAN�.:;.;.c � � qFCHITE�2acP•�: ,,,,zniizoso > m 0 Y U x U 'm � � 0 F .a�ME�rw�.rEs-r..�oEs���.Eai. a � ARCH JOB # 2019.050 � DRAWING NUMBER: AS.S � a