Loading...
HomeMy WebLinkAboutA015.6-SpecificationsSEGTION 09 90 00 - PAINTS AND GOATINGS A. PRODUCT/MANUFACTURER: SNERWIN WIL�IAI'S5. NO SUBSTITUTES. B. GENERAL- PAMT EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE FINISNED MSTALLATION. 4 SURFACES NOT TO BE PAINTED� PREFINISNED ITEMS, CONCEALED AND INACCESSIBLE AREAS, AND CODE-REQUIRED LABELS. D. STANDARDS: PROVIDE MATERIALS MEETING AS A MINIMUM CURRENT SCAQMD RULE III3 VOC STANDARDS OR LOCAL REGULATIONS WNICNEVER IS MORE STRINGENT. E SUBMITTALS- FURNISN PRODUCT DATA AND SAf'IPLES. I. DUPLICATE PAINTED FINISNES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES AND �OMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK. F. GELNERY: DELNER I"IATERIALS TO JOB SITE IN ORIGINAL, NEW AND UNOPENED PACKAGES AND CONTAMERS BEARING MANUFACTURER'S NAME AND LABEL. G. I"IATERIAL OUALITY: PROVIDE TOP LINE QUALITY GOMMERGIAL GRADE (PROFESSIONAL PAIN?ER) PAINTS. MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A BEST-GRADE PRODUCT SNALL NOT BE ACCEPTABLE. I METALS a. PRIMER� SNERWIN WILLIAMS PRO-CRYL UNIVERSAL PRIMER 866-310 SERIES b. TOP COAL SNERWIN WILLIAMS PRO INDUSTRIAL ZERO VOC AGRYLIC B66-600, B66-650, B6o-6o0 SERIES AS REQUIRED FOR FINI51-I. 2 MASONRY/CONCRETE� a. PRIMER� SNERWIN WILLIAP'IS LOXON CONCRETE & MASONRY PRIf'IER SEALER A24W8300 OR LOXON BLOCK SURPACER A24W200 AS RECOMMENDED BY MANUFACTURER FOR SURFACE. b. TOP COAT: SNERWIN WILLIAMS PRO MAR 200 ZERO VOC 820-2600, 830-2600 OR 83I-2600 SERIES AS REQUIRED FOR FINISN 3. GYPSUM 60ARD, BRICK PANELS, WOOD a. PRIMER� SNERWIN WILLIAMS PRO MAR 200 ZERO VOC LATEX PRII'9ER B28W2600 OR PREP RITE PROBLOCK LATEX FRIMER/SEALER 851-620 SERIES AS RECOMMENDED BY MANUFACTURER FOR SURFACE. b. TOP COAL SNERWIN WILLIAMS PRO MAR 20G ZERO VOC B20-2600, B30-2600 OR B3I-2600 SERIES AS REQUIRED FGR FINISN 4. DRYFALL: SNERWIN WILLIAMS PRO INDUSTRIAL WATERBASED DRYFALL FLAT 842-80 SERIES 5. COORDINATION: PROVIDE PRIMER, UNDERCOAT, BARRIER COAT AS RECOMMENDED FOR SURFACE TO BE PAINTED. PROVIDE FINISN COATS WNICN ARE COMPATIBLE WITN PRIME PAINTS, UNDERCOATS, AND BARRIER COATS. 6. INTERIOR PAINTS SNALL BE LOW ODOR, NO VOC IF AVAILABLE OR MEET VOC STANDARD IF NOT AVAILABLE. N_ COLORS AND FINISNES= PURE, NON-FADING; TYPES TO SUIT SERVICE INDICATED. NO LEAD CONTENT FERMITTED. COLORS AS INDICATED ON TFIE MATERIALS SCNECULE. I. PREPARATION�� PERFORM PREPARATION AND CLEANING PRGCEDURES IN ACCORDANCE WITN PAIN7 MANUFACTURER'S INS7RUCTIONS AND AS SPEQFIED FOR SUBSTRATE CONDITION. J. L EXAI'9WE AREAS AND CONDITIONS UNGER WNICN PAMTING WORK IS TO BE APPLIED. START OF PAMTING WGRK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS OF SURFACES AND CONDITIONS WITNIN ANY PART����AR AREA 2. REMOVE NARDWARE, ACCESSORIES, AND ITEMS IN PLACE AND NOT TO BE PAWTED, OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARATION AND PAINTING. REINSTALL REMOVED ITEMS AFTER PAMTING IS G0�1PLETED. APPLIGATION= APPLY PAWT IN ACCORDANCE WIT4J MANUPACTURER'S CIRECTIONS. USE APPLICATORS AND TECNNIG?UES BEST SUITED FOR SUBSTRATE AND TYPE GF I�ATERIAL BEING APPLIED. I. APPLY ADDITIONAL COATS IF STAINS OR BLEMISNES SNOW TNROUG41 FINAL COAT UNTIL PAINT IS A UNIPORM FINISN, COLOR AND APPEARANCE. RELEASEOFOR CONSTRIICTI�N sorTOMs aN� si�e e�Ges saMe as Faces. Su6jecuocompliancewithallregula�ions -ION TO ASSURE DRY FILM T4-IICKNE55 AT otS�a�eantlLocelCodes IS EQUIVALENT TO TNAT OF FLAT SURFACES. City of Carmel r �un��\i lo•rvalM��_ DATE: 03�20�20 K L. 3. PAMT SURFACES 6ENIND MOVABLE E�UIPMENT AND FURNITURE SAME AS SIMILAR EXPOSED SURPACES. PAINT SURFACES BEWND PERMANENTLY-FIXED EQUIPMENT AND FURNITURE. 4. PAINT BACK SIDES OF ACCE55 PANELS AND REMOVABLE OR NINGEC COVERS TO MATCN EXPOSED SURFACES_ 5. SAND LIGHTLY BETWEEN EACN SUCCEEGING ENAMEL AND VARNISN COAT. SCNEDULING PAINTING� APPLY FIRST COAT TO SURFACES TNAT NAVE BEEN CLEANED, PRETREATED OR PREPARED POR PAINTING AS SOON AS PRACTICABLE AFTER PREPARATION. I. ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT RECOAT UNTIL PAINT FEELS FIRM AND DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE TNUMB FRESSURE. MINIMUM COATING THICKNESS�� APPLY MATERIALS AT NOT LESS TNAN MANUFACTURER'S RECOMMENDED SPREADING RATE, ?0 ES?ABLISN A TOTAL DRY FlLM TFIICKNE55 AS RECOMMENDED BY COATING MANUFACTURER. M. PRIME CGATS� APPLY TO ITEMS NOT PREVIOUSLY PRIMED. RECOAT PRIMEG AND SEALED SURFACES WNERE THERE IS EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS M FIRST COAT. N. FINISN COATS: PROVIDE EVEN TEXTURE. LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID MARKS, OR OTNER SURFACE IMPERFECTIONS. C. PAINT SYS?EMS: PROVIDE MINIMUM ?WO COAT FLUS PRIMER SYSTEMS. I. GYPSUM 60ARD WALLS: EGGSLIELL (SATIN) LATEX EMULSION. 2. GYPSUM BOARD CEILINGS� FLAT LATEX EMULSION. 3. TOILET ROOM WALLS AND CEILINGS: SEMIGLO55 ACRYLIC ENAMEL. 4. INTERIOR PAINTED METAL. SEMIGLO55 100% ACRYLIC 5. SNEENS�� C01"IPLY WITN ASTI'1 D523, REFLECTANCE OF PAMT. P. CLEAN-UP� REMOVE DISCARDED PAINT MATERIALS, RUBBISN, CANS AND RAGS FROM SITE AT END OF EACN WORK DAY. I. CLEAN GLA55 AND PAINT-SPATTERED SURPACES IMMEDIATELY BY WASNING AND SCRAPWG- EXERQSE CARE NOT TO SCRATCN OR DAMAGE FINISNED SURPACES_ SEGTION 09 97 23 — GONGRETE FLOOR CAATINGS A. PRODUCTS/MANUFACTURERS: L CS-2: SNERWIN WILLIAMS REXTNANE I PLOOR COA?ING - CLEAR WITN 32 oz N&C SFJARKGRIP SLIP RESISTANT ADDITNE PER I GALLON REXTNANE I FLOOR COATING. 2 GS-3�. SNERWIN WILLIAMS REXTNANE I FLOOR COATING - BASE WNITE B. EXAMINATION: C. I. GENERAL CONTRACTOR AND C01'9PETENT INSTALLER TO REVIEW SUBSTRATE CONDITION AND NOTIFY DSW PM OF ANY CONDITIONS POTENTIALLY IMPACTING A TIMELY AND PROPER INSTALLATION. 2 INSTALLER TO ENSURE TNAT SUBSTRATE AND ENVIRONMENTAL CONDITIONS COMPLY WITN MANUF. WRITTEN APPLICATION INSTRUCTIONS. NOTIPI' DSW PM OF ANY CONDITIONS POTENTIALLY IMPACTING A TIMELY AND PROPER INSTALLATION. 3. PRIOR TO APPLICA?ION, CONFIRM TNA? SUBS?RA?E MEETS DSW STANDARDS FOR LEVEWE55 AND SLAB UNIFORMITY. CONSULT DSW PM ALL CONDITIONS ARE NOT ME?. SURFAGE PREPARATION= I. SURFACES TO BE OF SOUND CONDITION, T410ROUGFILY QEAN AND DRY PRIOR TO PRODUCT APPLICATION. ALL FOREIGN MATTER INCLUDMG BUT NOT LIMITED TO OIL, DUST, GREASE, DIRT, CNEMICAL RESIDUE, AND RUST TO BE REMOVED PRIOR TO APPLICATION. REPERENCE MANUPACTURER'S RECOMMENDATIONS PRIOR ?0 PRODUCT APPLICA?ION_ REFERENCE MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE TNAT ALL NECESSARY CONDITIONS ARE MET. 2 PATCN ANY VOID, DEFECT, OR CRACK LARGER TNAN Yz' IN WIDTN OR DEPTN PRIGR TO APPLICATION. ALLOW ALL PATCNES AND PGUR BACKS TO SUFFIQENTLY CURE PER MANUF. RECOh'IMENDATIONS PRIOR TO PRODUCT APPLICATION. NOTIFY THE DSW PI'9 SNOULD CURE TII'1ES POTENTIALLY IMPACT A TIMELY AND PROPER INSTALLATION. FLOOR PATCNING I"IATERIAL TO BE I'91NIMALLY APPLIED AND OF SII"IILAR COLOR TO EXISTING SUBSTRATE. �. PROTECTION: PRGTECT WORK OF OTNER TRADES, WNETNER TO BE PAMTED OR NGT. CORRECT DAP'IAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS ACCEPTABLE TO OWNER'S PROJECT MANAGER. I. PROVIDE "WET PAMT' SIGNS TO PROTECT NEWLY-PAWTED FINISNES. D 2 REMOVE TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTNERS FOR PROTECTION OF TNEIR WORK AFTER COMPLETION OF PAINTWG OPERATIONS. R. REPAIR� AT COMPLE?ION OF WORK OF OTNER TRADES, TOUCN-UP AND RESTORE DAMAGED SURFACES OR DEFACED PAINTED SURFACES_ S. CONTRACTOR IS TO LEAVE I GALLON UNOPENED OP EAG4J COLOR USED AND TAGGED W/ TNE FOLLOWING INFORI"IATION= I. PAINT # 2. PAINT COLOR AND SNEEN 3. MIX DATE MO/DAY/YEAR A. IDENTIFICATION OP ALL LOGATIONS TNE GOLOR IS USED 3. DO NOT CAULK OR FILL CONTROL JOINTS UNLE55 TNEY ARE Y" OR LARGER IN WIDTFI_ 4. MECHANICAL FLOOR PREP SNALL BE KEPT TO A MINIMUM. DO NOT EXCESSIVELY GRIND FLOOR INTEN? IS ONLY TO REMOVE CONTAMINAN?5 TFIAT WOULD PREVEN? PROPER ADNESION AND TO CREATE A PROPILE ADEGrUATE TO RECENE REXTNANE I FLOOR COATING. EXPOSING AGGREGATE SHOULD BE AVOIDED. 5. DO NOT BEAD BLAST OR MECNANICALLY PREPARE FLOOR BY ANY METH01 TNAT WILL LEAVE ANY TYPE OF GRIND/GUT MARK. APPLICATION OF STRIPING� I_ APPLICATION PATTERN: a. APPLY IN AGCORDANGE WITN DETAILS AND LOGATIONS INDICATED IN DSW SITE-SPEGFIC FINISN PLAN. 2. APPLY STRIPES PER MANUFACTURER'S WRITTEN WS7RUCTIONS: a. PROPERLY PREPARE SUBSTRATE PER TNE FOLLOWING INDUSTRY STANDARDS: ol_ ASTM D4258 - STANDARD PRACTICE FOR CLEANING CONCRETE a2. ASTM D425q - STANDARD PRACTICE FOR ABRADING CONCRETE a3 ASTM D4260 - STANDARD PRACTICE FOR ETCNING CONCRETE a4. ASTM F1869 - STANDARD TEST METNOD FOR MEASURING MOISTURE VAPOR EMISSION RATE OF CONCRETE. b. AFTER MASKING OFF ALL ADJACENT SURFACES NOT TO BE STRIPED, APPLY P9ATERIAL USING A 3/16" I"IONAIR ROLLER COVER. c. APPLY A SECOND COAT TO ACNIEVE SOLID, OPAQUE STRIPES AS REQUIRED. FOLLOW MANUFAC?URER'S RE-COAT WSTRUCTIONS. d_ ALLOW MA?ERIAL TO DRY AND CURE PER MANUPAC?URER'S RECOM�1ENDATIONS. E APPLICATION OP SEALER COAT� I. APPLY SEALER COAT PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND ALL GUIDELINES LISTED IN TNIS DOCUMENT. a_ PROPERLY PREPARE SUBSTRATE PER T4lE FOLLOWING INDUSTRY STANDARDS: al. ASTM D4258 - STANDARD PRACTICE FOR QEANING CONGRETE a2 ASTM DA25q - STANDARD PRACTICE POR ABRADING CONCRETE a3_ ASTM D4260 - STANDARD PRACTICE FOR ETCFIWG CONCRETE a4. ASTM F1869 - STANDARD TEST METNOD FOR MEASURING MOISTURE VAPOR EMISSION RATE OP GONGRETE. b. TNOROUGNLY MIX ONE 32 oz. CONTAINER OF SNARKGRIP SKID RESISTANT ADDITIVE PER ONE GALLON OF CLEAR REXTNANE I FLOOR COATING. APPLY MATERIAL USMG A�jb' MONAIR ROLLER COVER TO ENTIRE SALES FLOOR. CLEAR �OAT TO BE APPLIED OVER STRIPES AS WELL. c. GLEAR GOAT TO BE APPLIED PER STANDARD INDUSTRY PRACTICE TO PREVENT TNE APPEARANCE OF LAP AND APPLICATOR MARKS. d. REAPPLY TO ACNIEVE UNIFORM COVERAGE AND SNEEN PER WRITTEN MANU FACTURER' S I NSTRUC710N5_ DIVISION 10: SPECIALTIES SEGTION 10 14 00 — SIGNAGE A. PRODUCTS- ADA SIGNAGE B. GENERAL� INTERIOR SIGNAGE. C_ COMPLY WITN LOCAL CODE AND CURRENT ADA REQUIREMENTS_ D. PROVIDE AND INSTALL ADDITIONAL ADA SIGNAGE TO MATGN RESTROOM SIGNAGE AS REOUIRED BY GODE. E. LOCATE SIGNS WNERE REQUIRED BY APPLICABLE CODES E WSTALL LEVEL, PLUMB AND AT NEIGFIT SPEQFIED OR REQUIRED, WITFI SURPACES FREE FROM DISTORTION OR OTFIER APPEARANCE DEFECTS_ � � � a � Z 0 > � � o W N � O � N N w � Q N o � w N � � > J � w O mN o � � W W M NUUo 3 N��Z � rc�_ > � � W � � W � v=i 0¢�� m � W �UUU x n Z � � � N w � z � U � V a C/� a"�pfLOSsq' ��t��:e�3�5 iLqh;o Tef � _ ,, - �' �p�,�g-, z �%.l�SiAIEOF . ....pIDIPNAi.: . ; ��W NqCHREGoo�••••••`" ,,,,zniizozo > 0 Y U 2 U > z Q � 0 F .�.��rw�.xEs-r..�oEs��.�ai.Eai� a Si ARCH JOB # 2019.050 � DRAWING NUMBER: AS.6 � c