HomeMy WebLinkAboutE103-LowVoltagePlan0
7
RELOCAiE THERMOSTAT FOR
(E)RN-5 TO THIS LOCAiION�
�, - -
� �
� II /
2 I
�
I � �
!L i
nl------------
C�J
ATTACH BRACKETS TO STRUT USING
I/4" BOLT, I/4" FENDER WASNER AND I/4"
FIEX NUTS - SEE SECTION B-I
' �I/4" WASNER (AB-241-I/4") TO ROOF FRAMING MEMBER OR JOIST
SEE SECTION B-I �ABOVE
SYMBOLS LIST
LOW VOLTAGE PLAN
ISOMETRIC B-2
TO NEXT FIXTURE LAY-IN GRID ATTACNMENT (8Y 6C) IF APPLICABLE
I 5/8" x 13/I6" SUPER TO CEILING/STRUCTURE MOUNTED JUNCTION BOX.
STRUT� (B1400H5 IOPG) THREE WIRE, ONE JUNCTION BOX AND COVER PLATE PAINTED TO
NALF SLOT, 20'-0" CIRCUIT MC CABLE MATCN CEILING.
LENGTNS, GALV. FINISH. (BY EC)
STRAIGNT MC ZIP TIE MC CABLE
Bi2 CABLE TO ALL TNREAD.
CONNECTOR AIRCRAFT CABLE MOUNTED
TO STRUCTURE (TYP.)
90 DEGREE
MC CABLE CONNECTOR
RUN MC CABLE UP TNROUGN SLOT M STRUT MOUNTING BRACKET POWER SUPPLY UNIT
CNANNEL TO Np(T FIXTURE TNEN BACK DOWN (SUPPLIED WITN (PROVIDED WITFI FIXTURE)
TNROUGH SLOT CLOSEST FIXTURE) NOTE:
TO NEXT FIXTURE. PROVIDE A GROMMET TO I. NO PAINT APPLIED TO TNIS ASSEMBLY
PROTECT MC CABLE AT EACN SLOT USED. UNLE55 OTNERWISE N07ED.
5
-- - ---/�/O
\�/
SPEED LINK CABLE
(SLD205)
I/4" X 2" EYE BOLT
(R142E8)
SOUARE WASNER
(A8241-I/4)
SPRING NUT
(A100-I/4) /
SUPER STRUT �
I/4" BOLT, (B1400H5 IOPG)
I/4" FENDER MOUNTING BRACKET
WASHER AND (SUPPLIED WITN FIXTURE)
I/4" HEX pOWER UNIT
NUTS
(SUPPLIED WITN FIXTURE)
LED LAMP
(VERIFY PER SPECS.)
REFLECTOR
SECTION B-I (VERIFY PER SPECS.)
RELEA5E0 FOR CONSTRIICTI�N
Su6jec��o compliance with allregula�ions � I
of S�a�e antl Local Codes / NTS
City of Carmel
�"�n„�i,•va�a1_ ITING DETAILS
DATE: 03�20�20
TRACK
IOTE� DO NOT FASTEN TO CEILING OR ROOF DECK. ATTACH TO STRUCTURE
�BOVE ONLY (TYP.).SEE SNEET A4.1 FOR FIXTURE LOCATIONS.
�
�
�
�
�
WF
DEVICE LEGEND
O J-BOX «^' CCTV DVR
C7 DELNERY BUZZER "°g MUSIC NEAD IN
❑° DELIVERY BUZZER BUTTON O PEND. MTD. SPEAKER
^^E FIRE CONTROL PANEL aFlo RFID/EAS DEVICE
0 INTRUSION ALARM PANEL � PENDANT MTD DEVICE
PENDANT MTD.INTRUSION WIRE COILED ABOVE
� DEVICE � CLNG
� WALL MTD.INTRUSION DEVI E� MANUAL PULL-STATION
'" INTRUSION SIREN
WIRE LEGEND
RFID/EAS CAT6 SOLID COOPER CORE WIRE BY EC
CCTV CAMERAS CAT5E WIRE BY EC
INTRUSION KEYPAD 22GA / 4C - SOLID COPPER WIRE BY EC
INTRUSION DOOR 22GA / 4C - SOLID COPPER WIRE BY EC
CONTACTS
INTRUSION MOTION 22GA / 4C - SOLID COPPER WIRE BY EC
INTRUSION SIREN 22GA / 4C - SOLID COPPER WIRE BY EC
MUSIC SPEAKERS 18GA / 2C - STRANDED PLENUM COPPER
WIRE BY E.C.
MUSIC VOLUME 18GA / 2C - STRANDED PLENUM COPPER
CONTROLS WIRE BY E.C.
DOOR BUZZER AND 18GA / 2C - SOLID COPPER WIRE BY EC
BUTTON
ALL LOW VOLTAGE WIRE-
INCLUDING CAT5E-MUST BE WNITE
AIRCRAFT CABLE (SLD3L2-10' CABLE)
SEE SECTION B-I
I/4" EYE BOLT, SEE SECTION B-I
I 5/8° SUPER STRUT
(81400N5 IOP6) NALF 5L0T, 10'-0"
LENGTNS, GALVANIZED FINISN, TYP.
I 5/B" SUPER STRUT
° 2' 4' 8' r'` (81400N5 IOPG) FIALF SLOT, 10'-0"
�-� LENGTNS, GALVANIZED FINISN.
CODED NOTES
O1 EC TO SUPPLY AND INSTALL NETWORK GABLE (GAT6) AT ROOF
STRUCTURE AND M CONDUIT FROM CASNWRAP TO DSW NETWORK
SWITCN. CONFIRM SWITCN LOGATION WITN DSW PM.
O2 EC TO COORDINATE SPEAKER RELOCATION WITN DSW PM PRIOR
TO ROUGN-IN.
O
�� ��
4O EC TO SUPPLY AND INSTALL CAMERA WIRE (CATSE) AT ROOF
STRUCTURE FROM INDICATED LOCATION TO MANAGER'S OFFICE.
LEAVE 30' SERVICE LOOP AT CAMERA LOCATION AND 20' ABOVE
CEILING OF MANAGER'S OFFICE. SEE DETAIL L
SO DSW VENDOR TO RELOCATE EXISTING CAMERA VERIFY EXACT
LOCATION WITN SECURITY VENDOR PRIOR TO ROUGN-IN.
O6 EXISTING WIFI DEVICE TO REMAIN.
NOTES
NOT TO SCALE I A
ROOF DECK� BAR J015T
RED IRON
BDEVICE SUPPLIED AND
SECURED BY OTNER
20'-0" SERVICE
WIRE U.O.N.
DEVICE AND ADJUSTABLE
PENDANT SUPPLIED AND
SECURED BY OTFIERS
I-5/8" SUPER STRUT
STRAP - CNANNEL JOINER
WITN INTERNAL SET SCREWS (A213EG PG)
\ BUTT 10'-0" SECTIONS OF
SUPER STRUT TOGETNER,
CENTER STRAP-CHANNEL OVER
BUTT ENDS. (TNIS 15 AN
INTERIOR/NIDDEN CONNECTOR.
\ SET SCREW IS INTERNAL)
� STRUT CONNECTION DETAIL
NTS
E.C. RESPONSIBLE FOR
ATTACNMENT OF STEMS TO
ROOF STRUCTURE ABOVE
POWER FEED CONNECTS �
TO JUNCTION BOX AT
ROOF STRUCTURE
POWER FEED MCLUDED�
IN LIGNTING PACKAGE;
INSTALLED 8Y E.C., TO
BE NEATLY TIED TO
AIRCRAFT CABLE WITN
WHITE ZIP TIES.
WIRE COVER, INCLUDED IN LIGNTING
PACKAGE
TRACK MOUNTED
FIXTURE
�POWER UNIT
LED FIXTURE
NOTES:
I. SUPPLY AND INSTALL ALL REQUIRED SEISMIC REINFORCEMENTS
REQUIRED PER CODE AND AHJ.
2. NO PAINT APPLIED TO TFIIS ASSEMBLY UNLE55 OTFIERWISE NOTED.
3. ALL ITEMS SNOWN ARE PROVIDED BY DSW.
SUSPENSION STEM, PROVIDED BY
LIGNTING VENDOR. STANDARD 12" IB"
24", 36" AND 48" LENGTNS AVAILABLE.
IF LONGER LENGTNS ARE REOUIRED, E.C.
IS RESPONSIBLE FOR EXTENSION TO
STRUCTURE ABOVE.
PAINT SUSPENSION
57EM5 TO MATCFI
ROOF STRUCTURE
ABOVE, TYP.
12� I��� �20'-0" SERVICE
U.O.N. WIRE U.O.N.
FLOOR {
NOT6 TELESCOPING PENDANT MOUNT IS SUPPLIED AND WSTALLED BY
OTNERS. REFER TO RESPONSIBILITY SCNEDULE.
NOTE� TNESE DETAILS PERTAIN TO CAMERAS, INTRUSION DEVICES
SPEAKERS, FA DEVICES AND OTHER DEVICES SUPPLIED AND WSTALLED
BY OTNERS.
STRUCTURAL MTD DEVICESI"°TT°5°A`E I L
WIRE TO NEXT
SPEAKER
EXTEND I/2" CONDUIT �
�IAI_Idd�l � FP/IM PML
STRUCTURE WITN q0
DEGREE BEND (INSTALL
eUSNINGS)
CEILING MOUNTED
SPEAKER SUPPLIED AND
SECURED BY OTNERS —
J-BOX (IN-WALL) FOR
VOLUME GONTROL
20'_0" SERVICE WIRE
U.O.N.
No'TOS�A�E I N I AUDIO DETAIL
10'-0" SERVICE WIRE
�.a.N.
�%" CONDUIT (IN-WALL) FROM
BOX TO ABOVE ROOM CEILING
TILE (INSTALL BUSNINGS)
NOTTOSCALE I M
Z W � N
� = O
� F N N
� �
> � w �
� a o 0
w
N
�
� >
J
W � mN
� � W W M
Vo c
3 �aa� �
N��Z u
� O W H H J 0
w
V) OJJK �
� W (% U U (¢j .
r
Z �
h �
w
�
�
W
�
a
�
�
�
�'�GE A:.Maq ,,,
y`Z', �V�STFkc::�i
�
0
r
m
0
Y
U
U
z
¢
❑
m
z
¢
�
0
��� �� � y��.N�k ��4 �
ENG JOB # 19-41-215 0
DRAWING NUMBER: s
E1.3 r�
b