HomeMy WebLinkAboutE103-LowVoltagePlan0 7 RELOCAiE THERMOSTAT FOR (E)RN-5 TO THIS LOCAiION� �, - - � � � II / 2 I � I � � !L i nl------------ C�J ATTACH BRACKETS TO STRUT USING I/4" BOLT, I/4" FENDER WASNER AND I/4" FIEX NUTS - SEE SECTION B-I ' �I/4" WASNER (AB-241-I/4") TO ROOF FRAMING MEMBER OR JOIST SEE SECTION B-I �ABOVE SYMBOLS LIST LOW VOLTAGE PLAN ISOMETRIC B-2 TO NEXT FIXTURE LAY-IN GRID ATTACNMENT (8Y 6C) IF APPLICABLE I 5/8" x 13/I6" SUPER TO CEILING/STRUCTURE MOUNTED JUNCTION BOX. STRUT� (B1400H5 IOPG) THREE WIRE, ONE JUNCTION BOX AND COVER PLATE PAINTED TO NALF SLOT, 20'-0" CIRCUIT MC CABLE MATCN CEILING. LENGTNS, GALV. FINISH. (BY EC) STRAIGNT MC ZIP TIE MC CABLE Bi2 CABLE TO ALL TNREAD. CONNECTOR AIRCRAFT CABLE MOUNTED TO STRUCTURE (TYP.) 90 DEGREE MC CABLE CONNECTOR RUN MC CABLE UP TNROUGN SLOT M STRUT MOUNTING BRACKET POWER SUPPLY UNIT CNANNEL TO Np(T FIXTURE TNEN BACK DOWN (SUPPLIED WITN (PROVIDED WITFI FIXTURE) TNROUGH SLOT CLOSEST FIXTURE) NOTE: TO NEXT FIXTURE. PROVIDE A GROMMET TO I. NO PAINT APPLIED TO TNIS ASSEMBLY PROTECT MC CABLE AT EACN SLOT USED. UNLE55 OTNERWISE N07ED. 5 -- - ---/�/O \�/ SPEED LINK CABLE (SLD205) I/4" X 2" EYE BOLT (R142E8) SOUARE WASNER (A8241-I/4) SPRING NUT (A100-I/4) / SUPER STRUT � I/4" BOLT, (B1400H5 IOPG) I/4" FENDER MOUNTING BRACKET WASHER AND (SUPPLIED WITN FIXTURE) I/4" HEX pOWER UNIT NUTS (SUPPLIED WITN FIXTURE) LED LAMP (VERIFY PER SPECS.) REFLECTOR SECTION B-I (VERIFY PER SPECS.) RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions � I of S�a�e antl Local Codes / NTS City of Carmel �"�n„�i,•va�a1_ ITING DETAILS DATE: 03�20�20 TRACK IOTE� DO NOT FASTEN TO CEILING OR ROOF DECK. ATTACH TO STRUCTURE �BOVE ONLY (TYP.).SEE SNEET A4.1 FOR FIXTURE LOCATIONS. � � � � � WF DEVICE LEGEND O J-BOX «^' CCTV DVR C7 DELNERY BUZZER "°g MUSIC NEAD IN ❑° DELIVERY BUZZER BUTTON O PEND. MTD. SPEAKER ^^E FIRE CONTROL PANEL aFlo RFID/EAS DEVICE 0 INTRUSION ALARM PANEL � PENDANT MTD DEVICE PENDANT MTD.INTRUSION WIRE COILED ABOVE � DEVICE � CLNG � WALL MTD.INTRUSION DEVI E� MANUAL PULL-STATION '" INTRUSION SIREN WIRE LEGEND RFID/EAS CAT6 SOLID COOPER CORE WIRE BY EC CCTV CAMERAS CAT5E WIRE BY EC INTRUSION KEYPAD 22GA / 4C - SOLID COPPER WIRE BY EC INTRUSION DOOR 22GA / 4C - SOLID COPPER WIRE BY EC CONTACTS INTRUSION MOTION 22GA / 4C - SOLID COPPER WIRE BY EC INTRUSION SIREN 22GA / 4C - SOLID COPPER WIRE BY EC MUSIC SPEAKERS 18GA / 2C - STRANDED PLENUM COPPER WIRE BY E.C. MUSIC VOLUME 18GA / 2C - STRANDED PLENUM COPPER CONTROLS WIRE BY E.C. DOOR BUZZER AND 18GA / 2C - SOLID COPPER WIRE BY EC BUTTON ALL LOW VOLTAGE WIRE- INCLUDING CAT5E-MUST BE WNITE AIRCRAFT CABLE (SLD3L2-10' CABLE) SEE SECTION B-I I/4" EYE BOLT, SEE SECTION B-I I 5/8° SUPER STRUT (81400N5 IOP6) NALF 5L0T, 10'-0" LENGTNS, GALVANIZED FINISN, TYP. I 5/B" SUPER STRUT ° 2' 4' 8' r'` (81400N5 IOPG) FIALF SLOT, 10'-0" �-� LENGTNS, GALVANIZED FINISN. CODED NOTES O1 EC TO SUPPLY AND INSTALL NETWORK GABLE (GAT6) AT ROOF STRUCTURE AND M CONDUIT FROM CASNWRAP TO DSW NETWORK SWITCN. CONFIRM SWITCN LOGATION WITN DSW PM. O2 EC TO COORDINATE SPEAKER RELOCATION WITN DSW PM PRIOR TO ROUGN-IN. O �� �� 4O EC TO SUPPLY AND INSTALL CAMERA WIRE (CATSE) AT ROOF STRUCTURE FROM INDICATED LOCATION TO MANAGER'S OFFICE. LEAVE 30' SERVICE LOOP AT CAMERA LOCATION AND 20' ABOVE CEILING OF MANAGER'S OFFICE. SEE DETAIL L SO DSW VENDOR TO RELOCATE EXISTING CAMERA VERIFY EXACT LOCATION WITN SECURITY VENDOR PRIOR TO ROUGN-IN. O6 EXISTING WIFI DEVICE TO REMAIN. NOTES NOT TO SCALE I A ROOF DECK� BAR J015T RED IRON BDEVICE SUPPLIED AND SECURED BY OTNER 20'-0" SERVICE WIRE U.O.N. DEVICE AND ADJUSTABLE PENDANT SUPPLIED AND SECURED BY OTFIERS I-5/8" SUPER STRUT STRAP - CNANNEL JOINER WITN INTERNAL SET SCREWS (A213EG PG) \ BUTT 10'-0" SECTIONS OF SUPER STRUT TOGETNER, CENTER STRAP-CHANNEL OVER BUTT ENDS. (TNIS 15 AN INTERIOR/NIDDEN CONNECTOR. \ SET SCREW IS INTERNAL) � STRUT CONNECTION DETAIL NTS E.C. RESPONSIBLE FOR ATTACNMENT OF STEMS TO ROOF STRUCTURE ABOVE POWER FEED CONNECTS � TO JUNCTION BOX AT ROOF STRUCTURE POWER FEED MCLUDED� IN LIGNTING PACKAGE; INSTALLED 8Y E.C., TO BE NEATLY TIED TO AIRCRAFT CABLE WITN WHITE ZIP TIES. WIRE COVER, INCLUDED IN LIGNTING PACKAGE TRACK MOUNTED FIXTURE �POWER UNIT LED FIXTURE NOTES: I. SUPPLY AND INSTALL ALL REQUIRED SEISMIC REINFORCEMENTS REQUIRED PER CODE AND AHJ. 2. NO PAINT APPLIED TO TFIIS ASSEMBLY UNLE55 OTFIERWISE NOTED. 3. ALL ITEMS SNOWN ARE PROVIDED BY DSW. SUSPENSION STEM, PROVIDED BY LIGNTING VENDOR. STANDARD 12" IB" 24", 36" AND 48" LENGTNS AVAILABLE. IF LONGER LENGTNS ARE REOUIRED, E.C. IS RESPONSIBLE FOR EXTENSION TO STRUCTURE ABOVE. PAINT SUSPENSION 57EM5 TO MATCFI ROOF STRUCTURE ABOVE, TYP. 12� I��� �20'-0" SERVICE U.O.N. WIRE U.O.N. FLOOR { NOT6 TELESCOPING PENDANT MOUNT IS SUPPLIED AND WSTALLED BY OTNERS. REFER TO RESPONSIBILITY SCNEDULE. NOTE� TNESE DETAILS PERTAIN TO CAMERAS, INTRUSION DEVICES SPEAKERS, FA DEVICES AND OTHER DEVICES SUPPLIED AND WSTALLED BY OTNERS. STRUCTURAL MTD DEVICESI"°TT°5°A`E I L WIRE TO NEXT SPEAKER EXTEND I/2" CONDUIT � �IAI_Idd�l � FP/IM PML STRUCTURE WITN q0 DEGREE BEND (INSTALL eUSNINGS) CEILING MOUNTED SPEAKER SUPPLIED AND SECURED BY OTNERS — J-BOX (IN-WALL) FOR VOLUME GONTROL 20'_0" SERVICE WIRE U.O.N. No'TOS�A�E I N I AUDIO DETAIL 10'-0" SERVICE WIRE �.a.N. �%" CONDUIT (IN-WALL) FROM BOX TO ABOVE ROOM CEILING TILE (INSTALL BUSNINGS) NOTTOSCALE I M Z W � N � = O � F N N � � > � w � � a o 0 w N � � > J W � mN � � W W M Vo c 3 �aa� � N��Z u � O W H H J 0 w V) OJJK � � W (% U U (¢j . r Z � h � w � � W � a � � � �'�GE A:.Maq ,,, y`Z', �V�STFkc::�i � 0 r m 0 Y U U z ¢ ❑ m z ¢ � 0 ��� �� � y��.N�k ��4 � ENG JOB # 19-41-215 0 DRAWING NUMBER: s E1.3 r� b