HomeMy WebLinkAboutP103.2-PlumbingSpecifications15275 STERILIZATION
A. STERILIZE NEW DOMESTIC WATERLINES AFTER INSTALLATION.
6. FURNISH A CERTIFICATE CF STERILIZATION AND APPROVAL FOR NUMAN
CONSUMPTION TO BE SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN
74J15 STATE, REGULARLY EMPLOYED BY TNE TESTING LABORATORY.
CERTIFICATE MUST BE GIVEN TO THE TENANT BEFORE FINAL PAYMENT WILL
BE MADE
C. STERILIZATION SHALL 6E BY MEANS OF CFJLORINE INJECTED INTO TNE
WATER SYSTEM NEAR THE SOURCE AND CUTLETS TNROUGNOUT THE
SYSTEM 54JALL BE TESTED TO PROVE PRESENCE OF MINIMUM
RE�UIREMENTS. LEAVE CNLORINE IN FOR 24 NOURS AND FLUSH OUT
SYSTEM UFON COMPLETION OF WORK. STERILIZATION PROGEDURE SFJALL BE
WITNESSED BY TNE TENANT'S GENERAL CONTRACTOR.
D. STERILIZATION SHALL 6E PERFORMED UNDER TFJE IMMEDIATE SUPERVISION
OF A WATER TESTING LABORATORY REGULARLY ENGAGED IN THE SERVICE
AND SNALL BE DONE ACCORDING TO TNEIR INSTRUCTIONS.
15300 ELEGTRIC TANK TYPE WATER HEATER
A_ PRODUCTS� FURNISN AND INSTALL ELECTRIC WATER NFATER, SIZE,
LOCATION AND CAPAQTY AS INDICATED ON TNE DRAWINGS.
B. WATER NEATER SNALL BE AO SMITN. EQUAL 41EATERS BY RUUD, AMERICAN,
STATE, OR LOC4JINVAR MAY BE FURNI54JED AT TNE CONTRACTOR'S OPTION.
C. TANK TYPE ELECTRIC WATER NEATER WITN GLA55-LWED TANK RATED AT
I50 P51 WORKING PRESSURE, MAGNESIUM ANODE PROTECTION, BRONZE
DRAIN VAWE, NIGN TEMPERATURE CUT-OFF SWITCN ANG IMMERSION
TNERMGSTAT. TANK TG NAVE A MINIMUM R-VAWE OF 10.
D- PURNISN AND INSTALL A WATTS NO_ AOL, 3/4" TEMPERATURE AND
PRESSURE RELIEF VALVE AND EXTEND DISCNARGE PIPE, PULL SIZE, TO
WITFIIN 6" ABOVE T4lE JANITOR'S RECEPTOR OR PLOOR DRAIN_
E PROVIDE AMTROL EXPANSION TANK AS SIZED ON THE DRAWINGS. E�UAL
PRGGUCTS BY BELL ANC GOSSETT OR ADAMSON MAY BE PROVIDEC AT
TFIE CONTRACTOR'S OPTION_
15305 INSTANTANEOUS WATER I-IEATER
A_ PRODUCTS- FURNISFI AND INSTALL POINT OP USE ELECTRIC WATER 4lEATER,
SIZE, LOCATION AND CAPAQTY AS INDICATED ON TNE DRAWINGS_
6. WATER HEATER SNALL BE CNRONOMITE.
C. PCMT OF USE WATER NEATER TO NAVE CELCON WATERWAYS AND
NICNROME NEATING COILS OR AN APPROVED E�UAL.
15325 PLUMBING FIXTURES AND EQUIPMENT
A. PRODUGTS: WATER CLOSETS, URINALS AND LAVATORIES SNALL BE
VITREOUS CNINA BY AMERICAN STANDARD. VITREOUS CNINA FIXTURES
SNALL ALL BE BY TNE SAME MANUPACTURER.
B_ ALL PLOOR MOUNTED WATER CLOSETS, LAVATORIES, URINALS AND TRIM,
FWSN VALVES, ET4, SNALL BE MOUNTED AT TNE MANUFACTURER'S
REC0�1MENDED ROUGNING IN MEASUREMENTS, UNLE55 NOTED OTNERWISE.
C. VAWES TO BE AS FOLLOWS�
I25 LB. S.W.P. GATE, GLOBE AND CNECK VALVES:
L GATE (2-V2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED,
SOLID WEDGE DISC, SCREWED BONNET, RISING STEM.
2. BALL (2-I/2" AND SMALLER) - ALL BRONZE, TEPLON STEM SEALS
AND SEAT, I/4 TURN SNUT-0FF, VINYL GOVERED NANDLES.
3. GLOBE (2-V2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED,
SOLID WEDGE DISC, SCREWED BONNET, RISING STEM.
4- CFIECK (2-I/2" AND SMALLER) - ALL BRONZE, SCREWED,
NORIZONTAL SWING CNECK WIT4! BRONZE DISC.
D. VAWES SNALL BE MILWAUKEE. EOUAL PRODUCTS BY GRANE, NAM�10ND,
POWELL, WALWORTN, NIBCO OR STOCKNAM MAY BE FURNISNEC AT TNE
CONTRACTOR'S OPTICN.
E. UNIONS TO BE AS FOLLOWS:
I. UNIONS FOR COPPER PIPE TO BE 150L8., ALL BRONZE, SOLDER
NORTNERN INDIANA BRA55 COMPANY MAY BE FURNISNED AT TNE
CONTRACTOR'S OPTIGN.
2. DIELECTRIC UNIONS BETWEEN FERROUS AND COPPER SNALL BE
WSULATED TO PREVENT METAL-TO-METAL CONTACT AND SNALL BE
MANUFACTURED BY CAPITAL MANUFACTURING COMPANY OF
COLUMBUS, ONIO_ EQUAL FRODUCTS BY PATROL OR PECO SALES
COMPANY
RELEA5E0 FOR CONSTRIlCTION
Su6jec��o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��_
DATE: 03�20�20
F. QEANOUTS TO BE AS FOLLOWS:
I. FLOOR TYPE TO BE ADJUSTABLE CAST IRON WITN NICKEL BRONZE
TOP. ZURN #ZN-1400-T. TOP TO BE FLU54! WIT41 FLOOR FINISNES.
2. ALL TYPE TO BE CAST IRON TEE WITH ROUND POLISNED
STAWLE55 STEEL ACCE55 COVER AND TFJREADED PLUG. ZURN
#Z-1446_
G. FLGOR DRAINS TO BE AS FOLLOWS- CAST IRON BODY SNALLOW SUMP
DRAIN WITH DOUBLE DRAINAGE FLANGE AND WEEP4JOLE5, FLA54JING CLAMP,
BOTTOM OUTLET WITH NEOPRENE GASKET WSIDE CONNECTOR, SQUARE
ADJUSTABLE GRATE. FRAME AND GRATE TO NAVE POLISNED
NIGKEL-BRONZE FINISN. SEE DRAWINGS FOR MODEL AND MANUFAGTURER.
EQUAL PRODUCT MAY BE SUPPLIED AT T4lE CONTRACTOR'S OPTION.
N. BACKFLOW PREVENTER SNALL BE WILKINS 575 RP SERIES REDUCED
PRESSURE PRINCIPLE BACKPLOW PREVENTER TYPE, SIZE AS SNOWN ON TNE
DRAW I NGS.
15350 INSULATION
A. PRODUCTS: PIPE INSULATION AND APPURTENANCES AND COVERINGS ON
PIPES USED IN CNASES, SNAFTS OR OTNER CONCEALED SPACES IN TYPES I
AND 2 GONSTRUCTION SNALL NAVE A FLAME SFREAD RATING NOT
EXCEEDWG TWENTY-FIVE (25) AND IN TYPE 3 AND 4 CONSTRUCTION NOT
EXCEEDING SEVENTY-FIVE (75) AND A SMOKE DEVELOPED RATING NOT
EXCEEDING PIPTY (50).
B. INSULATION SNALL BE SCNULLER MICRO-LOK 650 FIBERGLA55 WITN
FAGTCRY APPLIED ALL SERVIGE JACKET WITN SELF-SEALING TAPE.
INSULATION SNALL LIMIT NEAT LO55 TC 25 BTU/NR./SO.FT. °F PIPE
SURFACE WITN 55 DEGREES AMBIENT, AND SNALL BE V^<" TNI�K GN COLD
WATER PIPING AND I" TNICK ON NOT WATER PIPING.
C. GLUE IN PLAGE WITN SCNULLER U-GLUE.
D. TNE FITTINGS SNALL BE INSULATED WITN SCNULLER ZESTON INSULATION
AND HAVE FACTORY PREMOLDED PVG COVERS. BUTT TNE JOINTS
TOGETNER AND WRAP WITN 3" WIDE STRIP TAPE, SEAL IN PLACE WITH
SCNULLER U-GLUE.
E. INSULATION SNALL NOT BE APPLIED UNTIL TNE GENERAL CONSTRUCTION
NAS PROGRESSED SUPFICIENTLY TO MSURE AGAWST PFJYSICAL OR
MOISTURE DAMAGE TO TNE WSULATION. ALL MSULATION DAMAGED
TNROUGN FAILURE TO OBSERVE TNIS DIRECTIVE SNALL BE REPLACEC AT
PLUMBING GONTRACTOR'S EXPENSE.
F. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS.
G. INSULATION 541ALL NOT BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN
PIPING.
N. INSULATION SNALL BE SCNULLER- EQUAL PRODUCT BY ARMSTRONG,
CERTAINTEED, OWENS-CORNING OR KNAUF MAY BE FURNISFIED AT T4lE
CONTRACTOR'S OPTION.
I_ ALL DOMESTIC NOT AND COLD WATER PIPWG IS TO BE INSULATED.
15375 PLUMBINCr SYSTEM TESTING
A. SYSTEM TESTING SNALL FROVIDE FOR TNE FOLLOWING�
I. TEST NEW INTERIOR DOMESTIC WATER SYSTEM.
2 TEST ALL SOIL, WASTE, AND VENT PIPING.
3. FURNISN ALL PUMPS FOR AIR AND WATER PRESSURE TESTS ALONG
WITN GAUGES AND ANY OTNER REQUIRED TEST EQUIPMENT-
4. UNDERGRGUND LINES TO BE TESTED BEFORE BEING CONCEALED.
CONTRACTOR
SNALL REPAIR ANY LEAKS AND ALL DAMAGE RESULTING T4JEREFROM.
5. CNANGES IN AMBIENT TEMPERATURE WILL BE TAKEN INTO ACCOUNT
WNEN TESTING UNDERGROUND PIPING, NOWEVER, TNE VARIOUS
SYSTEMS SNALL BE TNOROUGNLY INSPECTED FOR LEAKS BEFORE
NYDROSTATIC PRESSURE TESTS ARE CONCLUDED.
6_ INTERIOR WATER PIPMG� NYDROSTATIC TEST AT 125 P51 AWWA
PROCEDURES.
7. SOIL, WASTE, AND VENT PIPING SNALL BE WATER AND SMOKE OR AIR
T�GNT
(STATE PWMBING CODE).
B. MEASURE LEAKAGE BY METERING WATER REQUIRED TO MAMTAIN LME
PRESSURE. REMOVE AIR BEFORE TESTING.
C_ REPAIR ANY LEAKWG JOINTS AND DEMONSTRA7E ACCEPTABLE LEAKAGE TO
SATISFACTION OF TENANT'S REPRESENTATNE AND APPROVING AUTNORITY.
PWSN ALL PIPING BEPORE PLACING MTO OPERATION.
15410 FIRE PROTECTION CrENERAL PROVISIONS
A_ SPRINKLER CONTRACTOR SNALL DESIGN NEW SPRINKLER SYSTEM TO
MEET ALL LOCAL AND STATE REQUIREMENTS.
B. FURNISN ALL MATERIALS, LABOR, TOOLS, ADMINISTRATION,
TRANSPORTATION, INCIDENTALS AND APPURTENANCES WFJICN ARE
REQUIRED TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING
ORDER ALL ITEMS OF WORK CALLED FOR NEREIN OR SFJOWN ON TNE
ACCOMPANYING DRAWINGS. TWS CONTRACTOR IS RESPONSIBLE FOR
CONNECTING TO TNE FIRE ALARM SYSTEM. COORDINATE WITH FIRE ALARM
CONTRACTOR AND SPRINKLER CONTRACTOR.
C. FIRE PROTECTION CONTRACTOR TO DETERMINE ACTUAL AMOUNT AND
LOCATION CF NEADS. FIRE PROTECTION WATER SERVICE SIZE TO BE
DETERM MEG BY FIRE PROTECTION CONTRACTOR BY NYGRAULIC
CALCULATIONS PRIOR TO START OF WORK AS REQUIRED- FLOW & TAMPER
SWITCNES TO BE FROVIDED, INSTALLED, AND WIRED BY FIRE
PROTECTION CONTRACTOR AS REQUIRED.
D. INCLUDE ANY MINOR ITEMS OF WGRK NECESSARY TO PRCVIDE A
COMPLETE AND FULLY OPERATNE FIRE PROTECTION SYSTEM.
E. TNE FIRE PROTECTION CONTRACTOR SNALL BE RESPONSIBLE FOR
DETERMINING TNE EXACT NAZARD CLASSIFICATION, AS WELL A5, TNE
QUANTITY, SPACING, AND PROTECTED AREA LIMITATION OP SPRINKLER
NEADS. CONTRACTOR SNALL FURTNER BE RESPONSIBLE FOR CONFIRMING
HIS DETERMINATION WITFJ TNE OWNER'S INSURING AGENCY AND TFJE LOCAL
FIRE AUTNORITY NAVING JURISDICTION OVER TNE PROJECT.
P. WNERE APPLICABLE, LOCATE SPRINKLER NEADS IN CENTER OF CEILING
TILE, USE ARMOVER ON ALL SPRINKLER BRANCN LINES TO ACCOMPLISN
EXACT LOCATION OF NEAD.
G. T4lE INSTALLING CONTRACTOR SFIALL BE LICENSED AND CERTIFIED IN T41E
INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS IN TFlIS STATE
H. TNIS CONTRACTOR SFJALL OBTAIN AND PAY FOR ANY INSPECTION FEES,
CHARGES AND ANY OTHER GGVERNMENTAL FEES APPLICABLE.
L TNIS CONTRACTOR SNALL PILE ALL NECESSARY DRAWINGS,
SPEQFICATIONS, CONTRACTOR'S MANUAL AND TEST CERTIFICATES.
J. TNIS CONTRACTOR SNALL PROVIDE ALL PRODUCTS AND LABOR REQUIRED
TO COMPLETE TNE INSTALLATION OF ALL FIRE PROTEGTION SPRINKLER
SYSTEMS.
K. FIRE PROTECTION PIPING AND EQUIPMENT LAYOUT SNALL BE
COORDINATED WITN ALL EQUIPMENT, BOTN KNCWN AND UNKNOWN, AND
EQUIPMENT INCLUDED UNDER OTNER DIVISIONS OF TNE SPECIPICATIONS.
L. ALL FIRE PROTECTION PIPING SNALL BE INSTALLED AS CONCEALED WORK,
WNERE APPLICABLE
M. TFJE TENANT RESERVES TNE RIGHT TO CNANGE TNE LGCATION OF ANY
SPRINKLER 4JEAD DURING T4JE SUBMITTAL PROCESS EVEN IF TNE MOVE
SNOULD REQUIRE ADDITIONAL NEADS.
N. FILL ANNULAR SPACE BETWEEN SLEEVE AND PIPE OR INSULATION ON ALL
PENETRATIONS TNROUGN FIRE RATED WALLS. FIRESTOPPING MATERIALS
SNALL BE UL CLASSIFIEC AND MEET TNE REQUIREMENTS OF ASTM. TNE
METNOD OF INSULATION SNALL CONFORM TO UL FIRE RESISTANCE
DIRECTORY.
Q INSTALL ALL SPRINKLER NEADS IN ROOMS IN AN AESTNETIC MANNER.
SPRINKLER ARRANGEMENT SNALL BE PARALLEL AND PERPENDICULAR TO
TNE BUILDING WALLS.
P- TNE CONTRACTOR SNALL VERIFY TNE LOCATION OP UTILITIES AND NOTE
CONDITIONS WNICN WOULD AFFECT TNE WORK. ALL DISCREFANQES
SNALL TNEN BE REPORTED TO DSW PRIOR TO TNE BID AWARD.
Q. CONTRACTOR TO MAINTAIN ONE SET OF DRAWINGS ON TNE JOB TO BE
USED STRICTLY FOR RECORDWG ANY INSTALLATION DEVIATIONS FROM
TNE CONTRACT DRAWINGS.
R. TFJIS CONTRACTOR SNALL REVIEW AND FOLLOW ALL LANDLORD
REQUIREMENTS. TNE SUBMITTING OP A BID AUTOMATICALLY IMPLIES
TFJAT TNESE REQUIREMENTS HAVE BEEN REVIEWED AND ARE IN TNE BID
PRICE AND INFORM LANDLORD IN AGVANCE OF ANY SYSTEM DOWN TIME.
15413 SHOP DRAWINC.�S
A. ALL CONTRACTORS SUBMITTING PROPOSALS FOR TWS WORK SNALL FIRST
EXAMME TNE SITE AND ALL CONDITIONS TNEREIN. ALL PROPOSALS
SNALL TAKE INTO CONSIDERATION ALL SUCN CONDITIONS AS TNEY MAY
AFFECT TNE WORK UNDER TNIS CONTRACT. THE SUBMITTING OF A BID
AUTOMATICALLY IMPLIES TNAT TNIS EXAMINATION OP T4JE SITE 4JAS BEEN
DONE.
15417 TESTS
A. CONTRACTOR SNALL BE RESPONSIBLE FOR ALL TESTING OF SPRINKLER
PIPING PER NPPA_
B. TEST SPRINKLER PIPING WITN A NYDROSTATIC TEST AT 200 PSI FOR 2
HOURS WITN NO VISIBLE LEAKAGE.
C. TEST ALARMS, FLOW SWITCNES, ANC TAMPERPROOF SWITCNES AND
ADJUST AS NECESSARY.
15426 INTERIOR PIPE TUBE AND FITTINUS AND
SPRINKLER HEADS
A. SPRINKLER FIEADS:
I. ALL SPRINKLER HEADS SHALL BE NEW U.L, F.M. LISTED ANG
APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY CENTRAL
SPRINKLER CO_, GLOBE, SIMPLEX GRINNELL, RELIABLE, STAR, OR
VIKING.
2. ALL SPRINKLER NEADS SNALL BE RATED FOR 165°F UNLESS
INDICATED OTNERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES.
3. SPRINKLER NEADS IN CEILINGS (RESTROOMS, BREAK ROOM,
OFFICES) TO BE WNITE SEMI-RECESSED WIT4J WNITE TRIM. ANY
OTNER LOCATIONS TO BE DETERMMED BY TENANT GONSTRUCTION
MANAGER. VERIFY FJEAD TYPES AND COLORS WITFJ TNE
CONSTRUCTION MANAGER AND SUBMIT WITN SPRINKLER DRAWINGS
FOR PERMIT.
B. PIPING
L SCNEDULE 10, BLACK STEEL PIPE, ASTM A-53 POR FERROUS PIPING,
WELDED AND SEAMLE55, AN51 B-36-10-70 FOR WROUGNT STEEL
PIPE.
2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2
MCNES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS
POR PIPES LARGER T4JAN 2 WCNES.
3. GALVANIZED OR BLACK MALLEABLE IRON WITN BRA55 SEAT
SCREWED UNIONS FGR PIPES 2 INCNES AND SMALLER.
4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WNERE APPROVED BY
CODE AND TNE LANDLORD.
5. HANGERS SNALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS.
C. SPRINKLER SPAGNG SNALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS
AND I00 SQ. FT. IN "STOCK" AREAS. COMPLY WITN LANDLORD'S DESIGN
CRITERIA. PIPE SIZING SNALL BE BASED ON NFPA ORDINARY NAZARD.
D. WNERE POSSIBLE, REWORK TNE EXISTWG SPRINKLER SY57EM TO MEET
T4lE NEW REQUIREMENTS OF TWS DESIGN.
E_ PROVIDE AND WSTALL A VALVED TEST CONNECTION IN AN ACGESSIBLE
LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY
TNE LANDLORD, LOCAL INSPECTOR, OR INSURANGE GARRIER.
F. TNIS CONTRACTOR SNALL BE RESPONSIBLE FOR DAMAGE CAUSED BY
LEAKS IN ANY OF TNE EOUIPMENT MSTALLED BY NIM. ALL REPAIRS OR
REPLACEMENT OF DAMAGES SNALL BE AT TNIS CONTRACTOR'S EXPENSE.
G. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL
AND TEST CERTIFICATES" SNALL BE PURNISNED TO DSW, AND
AUTNORITIES NAVING JURISDICTION.
15430 SPRINKLER PIPIN6 SPEGIALTIES
A. PROVIDE ALL NECESSARY DRAINS. GOORDINATE TNE EXACT LOCATION
WITN TNE ARCNITECT AND LANDLORD PRIOR TO ANY INSTALLATION.
Z W w N
� � o
� F N N
� �
> � w �
W W � N
� a o 0
w
N
�
O �
W � mN
� � W W M
Vo c
3 �aa� �
N��Z u
�p W ��w o
V)OJJK �
� W (% U U (¢j .
r
Z �
C� �
h
w
�
�
�
U
�
a
�
�`�
f--1
�
�
r"GE q, !HQ ^+,
�y`Z'� �V�STFkr��i
❑
m
U
r
m
0
w
U
x
U
Y
a
�
m
z
¢
�
0
�
ENG JOB # 19-41-215 0
s
DRAWING NUMBER:
P6.2 �