HomeMy WebLinkAbout1A1 Floor PlansDEMO ALL EXISTING
�ECORATNE ACOUSTIC
WALLPANELS.
DEMO EXISTING
SPEAKER DEVICE.
r0EM0 EXISTING WOOD BLOCKING
I ON WALL.
DEMO ALL EXISTING
WALL MIRRORS.
DEMOLITION PLAN GENERAL NOTES:
1. SALVAGE ALL DOORS, FRAMES AND HARDWARE FOR POSSIBLE RE-USE IN
NEW CONSTRUCTION. UNUSED PARTS TO BE RETURNED TO LANDLORD OR
DISPOSED OF BV GC AT LANDLORD'S REQUEST.
2. REMOVEALLEXISTINGTOILETROOMFlXTURESBACCESSORIESAS
NECESSARV FOR RENOVATION AND RETURN TO OWNER FOR
RE-WSTALLATION AFTER WORK IS COMPLETE.
3. REMOVEEXISTINGRNISHESIROORINGTHROUGHOUTAREASOFWORK,
EXCEPT WHERE NOTED.
4. REMOVE ALL COATHOOKS THROUGHOUT AREA OF WORK.
1 DEMOLITION PLAN
scn�e ve� _ � a��
WB
I6�-11" SEE NOTE 3
EXISTING ENTRANCE'
STOREFRONTAND
EXTERIOR MATERIALS
TO REMAIN, NO
CHANGEPROPOSED,
TVP.
PACKINGI
¢ a SHIPPING
� � 101
s RETAIL p
$ALES
100
3'-0" SI�E H W GE�
SWINGWG
COUNTERDOOR.
wa _ ioai we
CONSTRUCTION PLAN GENERALNOTES:
7. GCTOPROVIDEANDINSTALLCONTINUOUSLAMINATECOUNTERTOPS
TO ALL NEW PREFABRICATE� CABINETS. SEE Fl1RNITURE PLAN FOR
ADDITIONAL WFORMATION.
2 GC TO PROVIDE BLOCKING/REWFORCEMENT WITHIN STUD WALLSAT
ALLPREFABRICATED CABWETS.PREFABRICATED PHARMACV SHELVES,
DOOR STOPS, NEW TOILET ROOM ACCESSORV LOCATIONS, AND OTHER
WALL ANCHORAGE ITEMS. ANCHORAGE THROUGH GWB ALONE IS NOT
ACCEPTABLE.
3. REMOVE DRYWALL AT EXISTING DEMISING WALL AS NECESSARY TO
INSTALL STUB-DOWN TO FEED KNEE WALL.
4. GC TO PROVIDE AN� INSTALL NEW PLUMBING FIXTURESAND
ACCESSORIES AS INDICATED ON THE DRAWINGS SEE ELEVATIONS 2/1A2
AND 3I1A2 FOR ADDITIONAL INFORMATION.
3 CONSTRUCTION PLAN
sca�e. va. = i,a.
� �m� K7 �+�SEE NOTE 2 -
� ��
3�-8" 3'-8 � p ��
"�rI,�N.� MIN �e:� , �
0
��
,-_ `� � 5,_z.
r�;x.:. ;; ,00
'"• 10I �
3 8" 3 8�
� 4-�
��" iN. 3'��, - MiN. €��
LL ��
a �i
E EO E �
PHARMACV/
PRODUCTION
,oZ
-EXISTING FULL-
HEIGHT WALL TO
REMAIN.
OPEN
OFFICE
103
�- GC TO PROVIDE 81NSTALL
UNDERCARPETCONNECTRAC.
E E'i.
a � IO2
3'-8 3 -
� `�-' �� ii��P�i'�"'
�4 ° ° � �4
J d
2f 2" I5 2.
�03
6 _2• 6 _2•
MiN. �' L�€�� 1 iN. �€��
� ��i ^< �i � � �
o �� ��
� �'r
�� ECA � ���I
n � n �� ✓�Yi
A• 8 fi
POWER SIGNAL PLAN GENERAL NOTES: �
1. GC TO FIEL� LOCATE ALL POWER AND DATA LOCATIONS TO
COORDINATE WITH FURNITURE INSTALL ON SITE.
2 GCTOPROVIDE&INSTALLSTUB-DOWNATE%ISTINGDEMISINGWALLTO
FEED POWER AND LOW VOLTAGE TO KNEE WALL.
3. GC TO PROVIDE & INSTALL LOW VOLTAGE WIRWG.
4. GC TO PROVIDE AN� INSTALL NEW WHITE COVERPLATES TO ALL
RELEA5E0 FOR CONSTRIICTI�N
Su6ject�o compliance with allregula�ions
of S�a�e antl Local Codes
City of Carmel
r
�un��\i lo•rvalM��'
DATE: 03�20�20
5 POWERSIGNALPLAN
SCAlE1/8.=1-0•
OEMO EXISTING RESTROOM
AND RETURN TO LA
UE
@ Sfi"HFF
DEMO E%ISTING
CEILING FAN
mSWITCH.
E E
DEMO EXISTING'
CARPET ON WALL.
DEMO EXISTING
SPEAKER DEVICE.
@
m
E E
..Slf
.. �
m
E E
cx«,
. ��
m
E E
..xli,
.. r
m
E
�:5�.
0
E E
- y�� DEMO EXISTING CEILING�
-��r FANSWITCH.
o f -� -�_
m
E E � ��
&
DEMOLITION REFLECTED CEILING PLAN GENERAL NOTES:
1. GC TO REPLACE EXIT SIGNAGE AS NECESSARV PER CODE.
2. DEMOALLEXISTINGACOUSTICCEILWGTILEANDGRIDINAREAOFWORK.
REPLACE WITH NEW. SEE FINISH SCHEDULE SHEET 1A2.
3. DEMOEXISTINGSURVEILLANCECAMERASTHROUGHOUT.
4. DEMOALLEXISTINGCEILINGFANS.
2 DEMOLITION REFLECTED CEILING PLAN
scn�en;e�� = uo�
----------------
- z .
� �
� y'-7' 7'-7' Q ESTROOM
6 JANITOR O B
inz `� � � � ROOM 'I08 � �
140.1 � 04
: z � 6� b�-b" Y-
m ������ LIGN_ 1402
� � p /
J LPROVI�E4'-0"
HIGH PLVWOOD
PHARMACVI
STORAGE
106
=fi�
�� ss" AFF
�� 102
m m m
E E E E q.ie.o��urmr E E
1OI
� "�'
m m m
E E E E E E
103
REFLECTED CEILING PLAN GENERAL NOTES:
1. ALLACOUSTICCEILINGSARETORECBVENEWTILES,(ACT7).
2. ALLACOUSTICCEILINGSARETORECEIVENEWCEILINGGRID,�GRi).
3. GC TO CONFlRM ALL EXISTMG EXIT SIGNS PROVIDED BV LANDLOR�
ARE UP TO CODE. REPLACE AS NECESSARV.
4. GC TO PROVIDE AND INSTALL (i ) CAT fi CABLE IN CEILING WHERE
WAPs & CAMERAS ARE INDICATED ON PLAN.
5. GC TO INSTALL FAN IN RESTROOM 108 AS NECESSARV PER CODE.
�n
�
� E
/
m
� � qns.o�wvc�r
100
m
E E
��
4 REFLECTED CEILING PLAN
9GALP.1/8"=1 L'
E
E
104 ' 108
-'� �ryCt'� MW �
4Y
° ��b4`a
��5
4'-7' 3. 8. 3. 8.
�I� �� ° MiN. �
, LL
� 106 0
� E EdU
J
8'-6"
II� ELECTRICAL
t� PANEL TO
REMAIN, VIF
i\�oe,...��,�i
3'' MIN,
100
p� P?
P1 WC1
P2
102
P1
P1 P1
�� P1
IOI
103
FINISH PLAN GENERAL NOTES:
1. PAINTALLWALLSURFACES(Pi),U.N.O.
2. PAINT EXISTWG CEILING AND HVAC ELEMENTS (P7) FLAT FINISH-
3. EVALUATE CONDITION OF ALL EXTERIOR DOOR THRESHOLDS. REPAIR AND
REPLACE AS NECESSARV.
4. PAINT ALL NEW �OORS AND FRAMES (Pi) SEMI-GLOSS FINISH, U N O. PREPARE
DOORS AS NECESSARV TO RECENE PAINT FlNISH.
5. GCTOPROVI�EANDINSTALLALLACCESSIBILITVSIGNAGEASNECESSARVPER
CODE.
6. GC TO PROVIDE AND INSTALL 3M ULTRA 5600 SAFETV AND SECURITV FlLM TO
EVERV PANE OF GLASS, INCLU�ING DOORS ON THE REAR AND FRONT OF SUITE
1G GC TO VISIT SITE TO DETEftM WE E%ACT pUANTITIES NEEpED.
6 FINISH PLAN
SCALE�.1i8' - li0'
.�
O
0
E
p�
B.ie. r �
mrr
E E
m
106
,os
�
WhknayArehlbels, Ine.
123 N Waebr I Sulb 2�50
Chleapo,IL 80808
T. 913A]1.3T/0
whltnqAO.eom
IL fARPORPTE LIC 18<-001680
uNosamvs�aEavwiorvauo.orrEarsro uvkrvowiFooE.
rorrmwi.Hmeaeo iRemenrsor.n-or o-cnr+me
BUILDiupORDiuqNCE,
WwiuEVAR4Y�REQ6,INC
nRcni.ea .._.._.._..
N
0
�
/ �
�
U/ �
\ �
� �
W
� W
� �
�
Z
� Q
O � N
M
�
Uw�
W �z
= o-
O���/
LL
Q NU
r
- ISSUEFORBIDANDPERMIT 122319
REV. �ESCRIPTION �ATE
ISSUES
PHASE:
CONSTRUCTION
DOCUMENTS
sHEEr oES�R�pr�oNPHASE
FLOOR PLANS
FLOOR NO.:
1 st
FLOOR
Scale: Joh N�mber:
i�e.=va�� nzo.os
Nanh: �rawn:
� �hkaKB 1 A 1
Q 2019 WHITNEV ARCHITECTS. MC.