HomeMy WebLinkAboutE200C1 C1
L1
W1 W1
W1
EF-1 EF-1 EF-1
P1-2
P1-1
11
1
EWH-1
EWH-1
EWH-1
Panel
'P1'
Service Disconnect.
(Confirm exact
location prior to
rough-in.)WPWPP1-3
P1-9
P1-3
P1-4
P1-5
P1-6 WH-A
P1-7
P1-8
J
Digital Time
Switch Location.
3
4
J
P1-10
JJ
P1-6 P1-6
P1-13
J J
J5
5 5
2
A.All 120V., 20 Amp circuits over 60' in length shall be #10
AWG.
B.Contractor shall coordinate with all other trades to avoid
conflicts of space.
C.Contractor shall coordinate the exact location of all
devices with all other trades prior to rough-in. Exact
location to be determined in the field.
D.Contractor shall coordinate with the mechanical and
plumbing contractors for exact locations of equipment prior
to rough-in.
E.Refer to sheet E600 for light fixture and panel schedule.
F.Refer to sheet E700 for symbols and details.
G.Shared neutrals shall not be permitted.
H.Switches shall be a maximum 48" A.F.F. to the top of the
device.
I.Outlets above counters shall be a maximum of 46" A.F.F.
to the top of the device.
J.All receptacles and data outlets shall be installed 18"
A.F.F. to top of the device unless otherwise noted in the
plans.
)GPGTCN0QVGU
Circuit shall be controlled by photocell 1P and digital time
switch 1HH. Provide and install photocell on roof.
Provide connection to hardwire power converter and make
connections to all water closet and faucet sensors as
required. Coordinate exact locations with plumbing
contractor prior to rough-in.
Provide circuit and connection to water fountain as required.
Coordinate exact location with plumbing contractor prior to
rough-in.
Provide 2" schedule 40 conduit under slab to IT cabinet,
confirm exact location prior to rough-in. Coordinate conduit
location with site utility plan.
Provide conduit from door security cabinet to a junction box
at latch side each door. Provide conduit to the head of the
door and around to the hinge side for future door security.
confirm exact locations prior to rough-in.
2NCP0QVGU
1
2
3
4
5 PROF
E
SS
IONA L E N G NIEERSA M U E L L.HU
R
TINDIA N A
0
N
EP1 6
.o
01087
ATS FOET
R E TEGIS
D
ERGNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100
Indianapolis, Indiana 46241
317.636.3941
YYY6'%Ä/'2EQO
THEENGINEERING
C O L L A B OR
A
T
I
VE