HomeMy WebLinkAboutP600REMARKSZURN NO. 100 200 400 500 600 300 P.D.I. CERTIFIED P.D.I. CERTIFIED P.D.I. CERTIFIED P.D.I. CERTIFIED P.D.I. CERTIFIED P.D.I. CERTIFIED WADE NO. W-5 W-10 5005 5010 J.R. SMITH NO. W-50 W-75 W-100 5030 5040 5050 5020 W-20 F.U. RATING 1 - 11 12 - 32 MARK 1" WHA-A WHA-B I.P.S. 3/4" 61 - 113 114 - 154 155 - 330 1" 1" WHA-D WHA-E 1"WHA-F WHA-C 1"33 - 60 Water Hammer Arrestor Schedule (WHA) NOTE: Locate water hammer arrestor in an accessible location, above finished ceiling. NOTE: This contractor to provide for testing and certification per state requirements. Pipe discharge to floor drain Air gap drain funnel From water supply source Line size shut-off (typ) To system 2NWODKPI(KZVWTG5EJGFWNG Mark No. Description HW CW W V Pipe Connections (in)Model Numbers WATER CLOSET - 1.28 GPF, Vitreous china, wall mtd., elongated bowl, siphon jet. Battery operated, automatic, top spud, flush valve. Open front seat less cover. Chrome plated brass supply. Carrier. + 18" A.F.F. to top of seat to suit ADA. Flush actuator to be on wide side of stall. Map score: 800 grams or better. WC-1H -1 3 2 CHURCH #295C CARRIER: PC to select carrier on the basis of field conditions at each location KOHLER #K-4323-0 ZURN #ZEMS6152AV-HET-HW6 MOP SINK - Floor mounted, 24" X 24", cast polymer. Provide hose with hanger, mop hook, p-trap, ss strainer, ss wall guards. Service faucet with vacuum breaker. Seal at wall. MS-1 34 34 3 2 FLORESTONE #MSR-2424 SPEAKMAN #SC-5814 FLORESTONE #MR-370, MR-372, MR-373, MR-375 MURDOCK #M-OBR4-GRD-FRA3 DRINKING FOUNTAIN - Tandum, two-level stainless steel round bowls, recessed bottle filler, barrier free, push buttons, freeze resistant valve system. Provide p-trap, supplies and stops. Mount per ADA requirements at +3412" A.F.F. to bubbler. DF-1H -12 112 114 FLOOR DRAIN - Ductile iron body, nickel bronze round flat strainer. Deep seal p-trap with trap seal.FD-A ---2 SIOUX CHIEF #832 SURE SEAL #SS2009V WILKINS #375XLREDUCED PRESSURE ZONE BACKFLOW PREVENTER - Make and model as approved by the Ind. Dept. of Health.RPZ-A 2--- EXTERIOR CLEAN OUT - (Paved areas) Ductile iron body, round scoriated nickel bronze reinforced cover, brass plug. (Unpaved areas) PVC body, round scoriated nickel bronze cover, brass plug. CO-A SIOUX CHIEF #851-N SIOUX CHIEF #834-NRBH (PAVED AREAS)--SIZE LINE - BRADFORD WHITE #LE120L3-3WATER HEATER - Electric, shelf mounted, 19 gal. storage, 2.5 kW, 120V., 1Ø, energy saver. Overflow pan. Thermal expansion tank. Set outlet temperature to 140°F. WH-A --34 34 WATER-TITE #HP 2022 AMTROL #ST-5 34 34MV-A MIXING VALVE - ASSE 1017. Thermostatically controlled, temperature and pressure compensated. Provide with unions, check stops, shut off valve & thermometer. Set outlet temperature to 110°F. --LAWLER #84008-61-15 Notes Provide one (1) power converter to serve all automatic plumbing valves. Power to faucet to be from power converter supplied with water closet flush valve.KOHLER #K2006-0 LAVATORY - Vitreous china, wall hung. Faucet: 1.5 GPM, single hole, lever handle, flat plate strainer. Accessories: Cast brass trap w/ co., loose key stops, chrome plated supplies, offset tailpiece, protective pipe and valve coverings, floor mounted carrier with concealed arm support. Mount @34" to rim, to suit ADA. L-1H 12 12 112 114 ZURN #Z1231-EZ TRUEBRO #103 E-Z ZURN #Z6913-XL-CP4-MV WOODFORD #B67 FREEZE PROOF HOSE BIB - Wall mounted, cast bronze valve, chrome plated face plate, automatic draining, stainless steel stem, integral backflow protection, locking box. FPHB -34 -- HOSE BIBB - Chrome plated, brass valve, loose key, integral vacuum breaker.HB-A OR --12 WOODFORD #24-12 12 Extend drain to nearest code approved discharge point. 34"CW Wall bracket, if not provided by mfgr., shall be constructed of angle iron suitable for support of unit. Thermometer ASME T&P relief valve Mixing valve (MV-B) 34"HW Thermal expansion tank similar and equal to Amtrol #ST-5. Support as necessary. CW main NOTE: Details shown here are typical only and may not be complete. Contractor shall provide all material and labor necessary for the configuration, piping and accessories required to operate this system in the manner intended with complete safety. Overflow pan Vertical pipe drop out of bottom of horizontal pipe Vertical pipe rise out of top of horizontal pipe Freeze proof hose bibb (FPHB) Floor drain (FD) Shutoff valve in pipe 90° Elbow down (drop in pipe) 90° Elbow up (rise in pipe) Clean out in floorCO Sanitary below grade or slab (W) Vent piping (V) 2NWODKPI5[ODQNUCPF#DDTGXKCVKQPU Cold water piping (CW) Hot water piping (HW)PROF E SS IONA L E N G NIEERSA M U E L L.HU R TINDIA N A 0 N EP1 6 .o 01087 ATS FOET R E TEGIS D ERGNIBMULP·LACITCELE·LACINAHCEM R2410 Executive Drive - Suite 100 Indianapolis, Indiana 46241 317.636.3941 YYY6'%Ä/'2EQO THEENGINEERING C O L L A B OR A T I VE