Loading...
HomeMy WebLinkAboutC600 - Storm Plan & Profile S4A-C601752.57752.62FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM 20' Force Main Easement Inst. No.: 2008-043639 EX. BASIN (VS4) W WW W WW WWWWWWW> o o o15' D&U.E.10' D.U.&S.S.E.50' VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.4' R.A.E.THE GROVE AT THE LEGACY SECTION THREE A Inst.#2020004967 PC. #5, Slide #1105 CHERRY CREEK BOULEVARD ANTIQUITY DRIVE JAMES DEAN DRIVEEX. 12" FORCEMAIN EX. 8" WATER MAIN EX. FIRE HYDRANT W W W W W W W W W W W W W W W W W WWWWWWWWWWWWWWW W W W W W W W W W W W50' R/W30' B-BANTIQUITY DRIVE (PUBLIC)WILBUR ROAD(PRIVATE)ALLEY WEST(PRIVATE)ALLEY EAST(PRIVATE)873 845 846 849 867 868 869 872 750 753752751 754 755847 875 874 876 877 878 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.LARSON DRIVE(PUBLIC)LARSON DRIVE(PUBLIC)30' R.D.E.CHERRY CREEK BOULEVARD 10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E. 10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E. 10' D.U.&S.S.E. 10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' B.L.6' D.U.&S.S.E.6' D.U.&S.S.E.10' D.U.&S.S.E.VAR. SIGNEASEMENTANTIQUITY DRIVE (PUBLIC) ALLEY WEST TO EAST (PRIVATE) 184A 184B 183A 183B 182A 182B 66A 66B 67A 67B 68A 68B 63A63B64A64B65A65B181A181B180A180B179A179B 60B 60A 61B 61A 62B 62A176B 176A 177B 177A 178B 178A 440' L.F. OF PROPOSED 6" SSD 229' L.F. OF PROPOSED 6" SSD511' L.F. OF EXISTING 6" SSD 600' L.F. OF EXISTING 6" SSD SCALE: 1"=50' HOR. 1"=5' VERT. 735 740 750 760 735 740 750 760AREA INLET #847STA. 0+00TC=753.61CURB INLET #846STA. 0+92TC=754.62CURB INLET #845STA. 1+22TC=754.6230 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=750.65 DOWN INV.=750.56 12" R.C.P. N INV.=749.65 15" R.C.P. S INV.=749.55 12" R.C.P. E INV.=749.97 92 L.F. 0.53% 12" R.C.P. CLASS II I 749.97 750.46 PROPOSED GRADE EXISTING GRADE ANTIQUITY DRIVEHYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 735 740 750 760 735 740 750 760CURB INLET #875STA. 0+61TC=754.09CURB INLET #874STA. 0+31TC=754.09MANHOLE #EX177STA. 0+00TC=755.1031 L.F. 0.33% 12" R.C.P. CLASS III UP INV.=749.90 DOWN INV.=749.80 30 L.F. 0.43% 12" R.C.P. CLASS III UP INV.=750.13 DOWN INV.=750.00 12" R.C.P. NE INV.=749.80 30" R.C.P. NW INV.=748.97 30" R.C.P. S INV.=748.87 PROPOSED GRADE EXISTING GRADE ANTIQUITY DRIVEHYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 740 750 760 740 750 760 21" R.C.P. W INV.=747.85 12" R.C.P. E INV.=748.08 15" R.C.P. S INV.=749.95 14 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=749.99 DOWN INV.=749.95DBL. CURB INLET #878STA. 0+14TC=754.77MANHOLE #872STA. 2+36TC=754.77PROPOSED GRADE EXISTING GRADE HYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 740 750 760 740 750 760 23 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=751.62 DOWN INV.=751.55 12" R.C.P. N INV.=749.45 12" R.C.P. W INV.=749.35 12" R.C.P. SW INV.=751.55 12" R.C.P. E INV.=751.35CURB INLET #876STA. 0+23TC=756.11AREA INLET #869STA. 0+00TC=755.87PROPOSED GRADE EXISTING GRADE HYDRAULIC GRADE LINE SCALE: 1"=50' HOR. 1"=5' VERT. 740 750 760 740 750 760 EXISTING GRADE 14 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=751.39 DOWN INV.=751.35AREA INLET #869STA. 0+00TC=755.87CURB INLET #877STA. 0+14TC=755.8512" R.C.P. N INV.=749.45 12" R.C.P. W INV.=749.35 12" R.C.P. SW INV.=751.55 12" R.C.P. E INV.=751.35 PROPOSED GRADE HYDRAULIC GRADE LINE 8" WATER18"MINLEGEND DENOTES CONSTRUCTION LIMITS EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE DENOTES FULL DEPTH GRANULAR BACKFILL (SEE TRENCH DETAIL 10-31 ON SHEET C801A APPROXIMATE LIMITS OF FLOODWAY, AS SCALED FROM FIRM MAP PANEL Nos.: 18057C0206G / 208G DATED: NOVEMBER 19, 2014 APPROXIMATE LIMITS OF FLOODWAY, AS SCALED FROM FIRM MAP PANEL Nos.: 18057C0206G / 208G DATED: NOVEMBER 19, 2014 FWF(FIRM) FWF(FIRM)DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO.THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942SHEET NO. DRAWN BY:CHECKED BY:STORM PLAN & PROFILESECTION FOUR AC601 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT NOTES ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD PLAN D-18 ON SHEET C801A. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A ON THE TRENCH DETAIL. ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. ANY STORM SEWERS UNDER PRIVATE ROADS WILL BE PRIVATE. ALL OTHER STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC. THE CITY OF CARMEL WILL NOT MAINTAIN CURBSIDE SSDs OR STORM SEWER IN PRIVATE ALLEYS. MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. STORM SEWER NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY THE CITY OF CARMEL. UTILITY CROSSINGS CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 55115PYT-S4THE GROVE at THE LEGACYKJJM/JAW BKR CLAY TOWNSHIPHAMILTON COUNTY, INDIANA03/18/20DP IT E S G E E O TS R P RTE W LE D E HVADIRJ .ADNINAI EEG NIRENOILA NS F EPRO STATE OF S File Name:S:\55115-PYT-S4\DWG\C600 - Storm Plan & Profile S4A.dwg - C601Modified / By:August 14, 2020 2:21:49 PM / dmetzPlotted / By:August 14, 2020 2:56:58 PM / Darren Metz04/29/20REVISED PER TAC COMMENTSDSM05/13/20REVISED PER CLIENT COMMENTSDSM