Loading...
HomeMy WebLinkAboutC305 Storm Water Poll. & Prev. Plan S4B-C307750750 755 755751751 752 753 754 754756 756757 757750750755755755751751752752753753754754756758759 756 756 757 757756EX. MH. #735 T.C.=755.73 8" S.D.R. 35 P.V.C N INV.=750.21 EX. MH. #736 T.C.=755.93 8" S.D.R. 35 P.V.C S INV.=750.50 EX. MH. #726 T.C.=758.49 8" S.D.R. 26 P.V.C N INV.=744.62 8" S.D.R. 26 P.V.C S INV.=744.52 8" S.D.R. 26 P.V.C W INV.=746.23 EX. MH. #725 T.C.=757.98 8" S.D.R. 26 P.V.C E INV.=748.98 8" S.D.R. 35 P.V.C W INV.=749.08 EX. MH. #714 T.C.=754.21 8" S.D.R. 26 P.V.C W INV.=740.71 8" S.D.R. 26 P.V.C E INV.=740.65 EX. MH. #713 T.C.=753.44 8" S.D.R. 26 P.V.C W INV.=739.21 8" S.D.R. 26 P.V.C E INV.=739.16 EX. MH. #712 T.C.=755.06 8" S.D.R. 26 P.V.C S INV.=741.69 8" S.D.R. 26 P.V.C N INV.=737.61 8" S.D.R. 26 P.V.C W INV.=737.43 8" S.D.R. 26 P.V.C E INV.=737.09 EX. MH. #720 EX. MH. #722A T.C.=755.68 8" S.D.R. 26 P.V.C E INV.=742.24 8" S.D.R. 26 P.V.C S INV.=737.81 EX. MH. #722 T.C.=756.30 8" S.D.R. 26 P.V.C N INV.=742.86 8" S.D.R. 26 P.V.C W INV.=742.76 EX. MH. #724 T.C.=757.23 8" S.D.R. 26 P.V.C N INV.=743.60 8" S.D.R. 26 P.V.C S INV.=743.52 8" S.D.R. 26 P.V.C W INV.=745.14 EX. MH. #734 T.C.=757.89 8" S.D.R. 35 P.V.C S INV.=748.92 8" S.D.R. 26 P.V.C E INV.=748.82 8" S.D.R. 35 P.V.C N INV.=749.70 EX. CURB INLET #803 T.C.=755.18 18" R.C.P. NW INV.=749.74 21" R.C.P. S INV.=749.64 21" R.C.P. E INV.=749.74 EX. CURB INLET #804 T.C.=754.42 21" R.C.P. N INV.=749.14 24" R.C.P. S EX. MANHOLE #802 T.C.=755.43 18" R.C.P. N INV.=749.93 18" R.C.P. SE INV.=749.83 12" R.C.P. W INV.=750.28 EX. CURB INLET #813 T.C.=755.25 12" R.C.P. W INV.=751.66 12" R.C.P. E INV.=751.56 EX. CURB INLET #812 T.C.=755.32 12" R.C.P. E INV.=751.76 EX. YARD INLET #801 T.C.=755.97 18" R.C.P. N INV.=750.90 18" R.C.P. S INV.=750.80 EX. YARD INLET #800 T.C.=755.77 15" R.C.P. N INV.=751.41 18" R.C.P. S INV.=751.31 EX. YARD INLET #799 T.C.=755.68 15" R.C.P. S INV.=752.05 12" R.C.P. N INV.=752.65 EX. END SECTION #800A 12" R.C.P. S INV.=753.15 20' Force Main Easement Inst. No.: 2008-043639 EX. YARD INLET #836 T.C.=756.37 12" R.C.P. W INV.=752.50 EX. YARD INLET #825 T.C.=756.44 15" R.C.P. W INV.=751.54 12" R.C.P. E INV.=751.54 EX. MANHOLE #826 T.C.=755.94 27" R.C.P. SW INV.=751.16 18" R.C.P. S INV.=751.25 15" R.C.P. E INV.=751.16 EX. MANHOLE #862 T.C.=756.49 18" R.C.P. E INV.=751.50 18" R.C.P. N INV.=751.45 EX. CURB INLET #827 T.C.=756.18 27" R.C.P. NE INV.=751.00 30" R.C.P. W INV.=751.00 EX. YARD INLET #828 T.C.=755.47 30" R.C.P. E INV.=750.80 30" R.C.P. W INV.=750.80 12" R.C.P. S INV.=751.00 15" R.C.P. N INV.=751.00 EX. CURB INLET #829 T.C.=755.69 30" R.C.P. E INV.=749.97 36" R.C.P. W INV.=749.97 EX. CURB INLET W/2' SUMP #829A T.C.=755.63 36" R.C.P. E INV.=749.91 36" R.C.P. W INV.=749.91 EX. YARD INLET #843 T.C.=755.98 12" R.C.P. N INV.=751.71 EX. END SECTION #830 36" R.C.P. E INV.=749.79 EX. CURB INLET #839 T.C.=757.25 15" R.C.P. N INV.=753.12 EX. MANHOLE #840 T.C.=757.15 15" R.C.P. S INV.=752.91 18" R.C.P. W INV.=752.00 12" R.C.P. E INV.=752.10 EX. MANHOLE #837 T.C.=757.17 12" R.C.P. S INV.=752.91 12" R.C.P. W INV.=752.81 EX. CURB INLET #838 T.C.=757.32 12" R.C.P. N INV.=752.99 EX. MH. #725 T.C.=755.57 8" S.D.R. 35 P.V.C N INV.=745.22 8" S.D.R. 35 P.V.C SE INV.=745.12 EX. MH. #726 T.C.=756.32 8" S.D.R. 35 P.V.C S INV.=746.22 8" S.D.R. 35 P.V.C E INV.=746.32 EX. MH. #727 T.C.=756.66 8" S.D.R. 35 P.V.C N INV.=747.36 8" S.D.R. 35 P.V.C S INV.=747.14 8" S.D.R. 35 P.V.C W INV.=747.04 EX. MH. #728 T.C.=755.61 8" S.D.R. 35 P.V.C N INV.=748.22 EX. MH. #724 T.C.=758.66 8" S.D.R. 35 P.V.C E INV.=751.07 EX. MH. #226 T.C.=758.65 8" S.D.R. 35 P.V.C W INV.=749.66 8" S.D.R. 35 P.V.C E INV.=749.56 EX. MH. #723 T.C.=758.23 8" S.D.R. 35 P.V.C W INV.=749.17 8" S.D.R. 35 P.V.C E INV.=749.13 EX. MANHOLE #177 T.C.=754.60 30" R.C.P. NW INV.=748.97 30" R.C.P. S EX. END SECTION #178 30" R.C.P. SE INV.=749.81 EX. INLET #881 T.C.=754.04 12" R.C.P. S INV.=750.28 75775 8 756756 751 752 753 BIRTHRIGHT WAY WILBUR ROADANTIQUITY DRIVE BIRTHRIGHT WAY PICKETT PLACE JAMES DEAN DRIVE(PRIVATE) (PRIVATE) EX. 12" FORCEMAIN EX. 8" WATER MAIN EX. FIRE HYDRANT EX. FIRE HYDRANT EX. 8" WATER MAIN EX. FIRE HYDRANT W W W W W W W W W W W W G.C.A. #12 5,988 sq.ft. VAR. D.U.S.S.& 10' B.L.10' B.L.10' B.L. 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.VAR. D.U.P.A.E.& L.M.A.E. VAR. D.U.S.S.& L.M.A.E. PICKETT PLACE LARSON DRIVE15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E. 15' D&U.E.15' D&U.E.15' D&U.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E. 10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.(PRIVATE)(PRIVATE)(PRIVATE)EX. LAKE #2 (DD2) N.P.=750.00 10 YR. ELEV.=751.50 100 YR. ELEV.=753.94 T.O.B.=756.00 15 L.F. 12" R.C.P. @ 0.47% 240 L.F. 15" R.C.P. @ 0.22% 191 L.F. 15" R.C.P. @ 0.31% 15 L.F. 12" R.C.P. @ 1.40%115 L.F. 18" R.C.P. @ 0.18%188 L.F. 12" R.C.P. @ 0.30%113 L.F. 18" R.C.P. @ 0.14%191 L.F. 15" R.C.P. @ 0.18% 15 L.F. 12" R.C.P. @ 1.00% 160 L.F. 12" R.C.P. @ 0.61%WILBUR ROADL.C.A. #11 3,150 sq.ft. 86878889909192141140139138137 99989796959493132133134135136 166 167 161 160 159168 158 169 170 157 171 172 173 174 175 WWWWWWWWWWWL.C.A. #10 2,726 sq.ft.WWWWWSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFDATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942PERM. STORM WATER POLL. & PREV. PLANSECTION FOUR BC307 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT FOR EROSION CONTROL ONLY. THIS SHEET TO BE USED PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: TODD PYATT PHONE: (317) 379-0184 LEGEND DENOTES CONSTRUCTION LIMITS DENOTES SILT FENCE DENOTES PERMANENT SEEDING & MULCH AREAS SEEDING RATE: SEEDING MIXTURE: 130#/ACRE OR 3#/1000 S.F. 25% CREEPING RED FESCUE 35% PERENNIAL RYE 40% KENTUCKY BLUEGRASS DENOTES SEEDING W/FIBER BLANKET #S75 BY NORTH AMERICAN GREEN SEEDING RATE: SEEDING MIXTURE: 110#/ACRE OR 2.5#/1000 S.F. 38% KENTUCKY 31 FESCUE 19% PERENNIAL RYE 19% ANNUAL RYE 14% ORCHARD GRASS 10% KENTUCKY BLUEGRASS DENOTES TEMPORARY SEEDING & MULCHING SEEDING RATE: SEEDING MIXTURE: 50#/ACRE 100% PERENNIAL RYE SF SF NOTES 1 ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. 2 IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON POLYMER. 3 CONTRACTOR TO STAY WITHIN CONSTRUCTION LIMITS TO MAINTAIN VEGETATIVE BUFFER AREAS. 4 NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5 ANY DISCHARGE OF CONTAMINATED WATER DUE TO DEWATERING SHALL OUTLET THROUGH EXISTING VEGETATION OR FILTER BAGS THAT WILL NOT ADVERSELY IMPACT STORM WATER QUALITY. 55115PYT-S4THE GROVE at THE LEGACYKJJM/JAW BKR CLAY TOWNSHIPHAMILTON COUNTY, INDIANA03/18/20DP IT E S G E E O TS R P RTE W LE D E HVADIRJ .ADNINAI EEG NIRENOILA NS F EPRO STATE OF S File Name:S:\55115-PYT-S4\DWG\C305 Storm Water Poll. & Prev. Plan S4B.dwg - C307Modified / By:March 17, 2020 10:11:22 AM / jthurmanPlotted / By:March 18, 2020 12:35:29 PM / Kenny Mitchell