HomeMy WebLinkAbout37 - Carmel OBGYN P121BRFA�9ROOM
I
� �S�
� - ��
S�AFF TOILE�
�8 WHA-A
\
� �2 L
t
�VB-1
FPLL
M/
? JffRF
c a�e
�
� � L
� 5K-1 /.�1, EH�Z ll
�1 �
� (�
I
L�
PROCEDUREI=' —�I
�46
�
"�, —r,�
�-314"HW
I3I4"HW Z��CW`
� ��]
/SKd O�
- -11/7'V-
_I - DiQ.
444
—1 lav- — — —}— —f �
I� E 42813
���
} ex a^sr oN `
b `
SK-1 ' 21 � -- �
EXAM16 ��._ � -
424 �q10
423
�
\ S70RA6E
421
� I 501'
,z�
Ex i i/z"F�I
� Ex a^snm om � 3
�
�x a"v oN �
i
FXI�N 15 �
12i �"�
SK 1 2
��
o� �
�
SK-1 � i
�
E 418 6
�i wai �i'
w�-A �— �
f
�
I
�a �a �
>
� �
�
4 �
FXOM 5 �
di�
�
SK-1 �� -1 1/2'V-�� �� -1 l�2"V- �K � �
EXAM C FXAN'0 FXOM 9
445 r 443 � � 441
� �
HnLL �
44C
� £ 1 \2 :
-�'_� -1112"V_ - �
e � e
0
DIQ.
IX�fd G 992
1s1
.� � ,
�Ex i ilz^�
I� m DIQ.
J;H 435
�T ��CE -
� 4l 4
O1L� HALL
43I 932
4)
l0) / �I.IAV.l ..
� T� �
��
TEAM ROOf�I
411
1 \LL
912
1
�(z� �L �� �
- ---1 1�2"V � SK-1 2
I Lti� 1 "s
I �-'
I
o-� SK-1�) �
� _ _ _1 1/2"W - �
o-J EX 1 1/2"FP �
EX SHl7�-OFF
vn�ves
- 1 1/2'�h ^�
I NURSETRIA6E
I 439
� EX 11/2"F
�
�
fr�Hw ��sia^nwc
-yy _ _� 3/4"HW z����
� 3�q"HW
� � 3I�WC
o� � ' � _ — -�, r,
sL �z) �� - -i i�av> i i�
I I I� � 1 1/2 FP�—
EXA`d s' BLOOD DRAVJ �
93u 438
� _��1
�^ — — — �� ilr�v — —
I
� � �O � EX 4"5T DN
— I
� IXG`:li
�� 43J
SK-1 � 2 I
�1/P'CW —
�- �
�1/2"HW
� ]V �KE
�
�
I� ; I! :`�RE
9CS
�scneouuveoece I
i �od
� I
I
I
E J��I 2
109
I1/7'V -
EXAM 1
40�
f
>
- EX 4"V�R
Ex i
I U
- �� EX 9"SAN DN
^ I � - -
- EX 4"V-
EX 4"V DN
HALL
4W I
i
v
u'S
WAITL�G I
aoo
EX 11�2"FP li
- �
� �
1
11 .�1'
1 PLUMBING PLAN - 4TH FLOOR
3116" =1• 0••
RELEA5E0 FOR CONSTRIICTI�N
Su6jec� �o compliance with all regula�ions
of S�a�e antl Local Codes
City of Carmel
��!,,:,,,� ;:,.va�.
DATE: 03�Z6�2O
lAB
403
I:iii
SK-1 ( 21
� �
� WG2'..�1�W�I
��� 2���WAB
�
>
� NJOMEV�RFSTROOM�
� 902
�
F�-�
R-c-�noN N
�ioi
_ ---lz �
E%SHIJr-OFF
VALVES
I
j� - I I
L
;�
�'�03 �:
�`-_ 403i'>
<,4��,i
(iGIVKAL IYV 1 CJ:
A. THIS FNCILRY IS TO BE A FULLY SPRINKLED BUILDING. AS PART OF TH6
PRO]ECT, CONTRAQOR SHALL PROVI�E ADEQUATE COVERAGE OF THE SPACE IN
COMPLIANCE WITH NFPA-13. COMRAQOR SHALL BE RESPONSIBIE FOR
HYDRAULIC CALCUU+TfON$ AN� FIRE PROTEQION ORAWING$ NNO $UBMCfTALS
REQUIRED FOR SfATE APPROVAL REFER TO SPECIFICATIONS FOR REQUIRED
HFAD iYPES. PROVIDE NEW HEADS WHERE REQUIRED TO MEET SPECIFICATION
REQUIREMEGfrS.
B. PIDMG OFFSETS ARE NOT NECESSARILV SHOWN ON PLANS. IXTENSIVE
COORDINATION I$ REQUIRED BETWEEN TRADES. CONTRAQOR $HALL VERIFY
ALL ROUT1N65 PRIOR TO FABRICATION AND PROVIDE OFFSEfS 0.5 REQUIRED.
PLAN NOTES:
Di a° snN nno z�v oowN.
O2 2" SAN DOWN.
O CONNEQ2"VTOEX2"V.
O CONNECT 2" QN, 1" HW NND 3�9" HWC TO EX 2" CW 1" HW
AND 3�4" HWC.
OS 1-1/2" S4N DOWN.
O6 CONNER 1�2" HW AND 1/2" CW TO EX 1" HW AND 2" CW.
O7 CONNELT 3�4" HW AND 3�4" CW TO EX 1" HW AND 2" CW.
OB CONNELT 1-1�P' V TO EX P' V.
O CONNER 3�4" HW, 3�4" CW AND 3�4" HWC TO EX 1" HW, 2"
CW AN� 3�4" HWC.
10 CONNECT 1�2" HW AND 1-1�2" QN TO EX 1" HW AND 2" QN.
11 HOT WATER REfURN &4lANCMG STATION, T1'P. SEE DETAIL
2 ON THIS SHEEf.
12 CONNECT2"VTOEX4"V.
13 1/2" HW, 1�2" CW AND 1-1�Y' V DOWN IN WALL, 1�2' HW
AND 1�2" CW TO EMERENCY THERMOSfATIC MIXIN6 VALVE
BELOW COUNTEk. 1�2" TEPIDTO DECK MOUMED
EMER6ENCV EYEWASH. 1�2" CW AND 1�2" HW AND 1-1�2" V
TO SINK, 2" SAN DOWN.
PLUMBING FIXTURE ROUGH-IN SCHEDULE
DESCRIPTION ROUGHiNCONNECRONS
HW CW TEPID WPSfE VENT
WATER CLOSEf - 1 - 4" P'
IAVATORY 1/2" 1/2' - l-1/2" 1-1/2"
SINK 1/2" 1/2" - 2" 1-1/2"
ICE MAKER ROUGHiN - 1/2" - - -
EMERGENCYEVEWASH - - 1/2" - -
WATER HAMMER ARRESTER SCHEDULE
'E I.P.S FU, RATING J.R. SMIiH No. JOSAM No. ZURN No. WATTS No. REMFRN
�A 3�9" 1-11 5005 ]SOO1N Zll00-100 15M2-N P.D.I.CERT
; 6 1" 12-32 5010 ]5002B Zll04200 15MLB P.D.I. CERT
� C 1" 33-60 5020 ]5003C Zv00-300 15M2-C P.D.I.CERT
NOTE: PROVIDE SHUT-OFF VALVE WITH WATER HAMMER ARRESTER
TO HOT WATER
RECIRNIAIING MAIN
3�4
BA�� �A��E (TYP)
MANUAL BAIANCING VALVE, APPROVED
FOR USE WITH POTABLE WATER.
AD]UST TO APPROPRIATE FLOW
STRAINER WCfH BLOW�OWN
CONNECRON VALVED & CAPPED
2 HOT WATER RETURN BALANCING STATION DETAIL
NO SCALE
TRUE
NORTH
arc �Esi�N
. ..li _.:.. . . � _.,. ...-.
201 N. Delaware Street, Suite B
Indianapolis, IN 46204
317.951.9192 T � 317.951.9194 F
www.arcdesign.us
This tlrawing and its con�ents are the propehy
of arcDE51GN P.C., and shall not be
reproduced in whole or in pah by any means,
mechanical orelec�mnic, withou� express
wri[ten permission of arcDE51GN.
�-`
i or r.s tnr,iv�uiw:�, in<-.
``,.Q�EW K. fN,,,,,,,�
..
,P�..e��1§iEREo�O�;
No.
• PE11200650�i•
Z
� m w N
� O � �
� J � �
� � ��Q
� a �HZ
O � �(�w
� �
W M � Q
� � � U
Q �
Z
100% CONSTRUCTION
DOCUMENTS
0 REVISIONS:
DATE:
MARCH 12, 2020
arcDESIGN PROJECT NUMBER:
19764
DRAWNBV:
Author
DRAWING TITLE:
PLUMBING PLAN
- 4TH FLOOR
DRAWING NUMBER:
P121