Loading...
HomeMy WebLinkAboutCarmel A131� 0 0 0 0 0 CEILING LEGEND CEILING TAG �� CEILINGTYPE XXX-01 28'-00" AFF. �� CEILING HEIGHT (ABOVE FINISH FLOORf 9 SPOT ELEVATION MARKER �EXPOSED-PAWTEXPOSE� DECK CEILING PT40 �ACOUSTICCEILINGTILE-BUILDINGSTANDARDARMSTRONG. CORTEGA SECOND LOOK TO MATCH NORTH SUITE. ❑ DRVWALLBULKHEAD Ilf� 0 2 x 4 LIGHT FI%TURE - MATCH EXISTMG NORTH SUITE, INCLUDING WLORTEMPERTURE. PENDANT CAN- 8" DIAMETER - MATCH NORTH SUITE. INCWDMG COLOR TEMPERATURE. RWESSED LMEAR DOWN LIGHT - MATCH NORTH SUITE, CORONET LSR3 LED / NO TRIM SPACKLE FLANGE SRE TO MAINTAIN iT' CLEAR ON BOTH ENDS OF BULKHEAD. COLOR TEMPERTURE TO MATCH ExISTING NORTH SUITE. � 0 Blue Horseshoe SOIUtIOC1S 11939 N. Meridian St. Carmel, IN 46033 Blue Horseshoe Solutions 11939 N. Meridian Street Carmel, IN 46033 (317)730-2641 RATIO Architects, Inc. 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 CONSTRUCTION DOCUMENTS 04.04.2017 REISSUE CHECKEDBY APPROVEDBY I� jo fi;: RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel '!,,:,,, 'a .�;va,�1_ DATE: 03�Z��2O �BASE-SECOND LEVEL i.n� n n n n GENERAL CEILING PLAN NOTES � A THESE GENERAL NOTES APPLV TO SHEET A-131 REFLECTED CEILING �RAW INGS. B CENTER CEILING GRI�S WITHIN ROOMS EACH DIRECTION UNLE55 NOTED OTHERWISE. C LOCATECEILINGGRI�SWITHINROOMSSIICHTHAT BOR�ERS CONTAIN NOT LESS THAN 12 TLLE W IDTH. UNLE55 OTHERW ISE INDICATED. D CENTERPENETR4TIONSINACOUSTICALCEILINGSVSTEMS W ITHIN IN�IVI�UAL CEILMG PANELS. SUCH AS SPRINKLER HEA�S. DIFFUSER$ LIGHT FIXTURES. ETC., UNLE55 OTHERW ISE INDICATED. E PAINT EXPOSE� GVPSUM BOARD AND PLASTER CEILING SURFACES UNLESS OTHERWISE INDICATED.SEE FMSIH PLANS. F PROVIDE CONTROL JOINTS (C J.) IN GVPSUM BOARD CEILMG CONSTRUCTION AS INDICATED. WHERE NOT SHOW N, PROVIDE MAXIMUM SPACING BETW EEN JOMTS OF 30'-0" VERIFY FINAL CONTROL JOINT LOCATIONS WITH ARCHITECT PRIOR TO STARTING W ORK W HETHER OR NOT INDICATED ON THE DRAWMGS. G PROVIDEFULLCOVERAGEOFSOUN�BATTMSULATION OVER ENTIRE CEILING OF ENCLOSED ROOMS, INCW�ING TWO LARGE TEAM ROOMS, MEDIUM ENCLAVE ROOM, THREE OFFICES AND FOUR FOCUS ROOMS. PROVIDE SOUND BOOTS ABWE RETURN AIR GRILLS IN THESE ROOMS AS WELL TO MITIGATE SOUNO TR4NSFER. H REFERTOSHEETA-�01GENERALWFORMATIONDRAWINGS FOR MATERIAL SVMBOL KEV. I REFERTOSHEETA451FINISHPLANFORADDITIONAL CEILIN6 FlNISH MFORMATION. J REFER TO ELECTRICAL DRAW INGS FOR CEILING-MOUNTED LIGHT FIXTURE TVPES AND Ql1ANTITIES. K REFERTOMECHANICALDRAWMGSFORCEILING-MOUNTED DIFFUSERS, GRILLE TVPES AND QUANTITIES. L REFERTOFIREPROTECTIONDRAWINGSFORSPRINKLER HEA� TYPES AND QUANTITIES. HEADS HAVE BEEN INTENTIONALLV OMITTED FROM REFLECTE� CEILING PLANS FOR CLARITV. M PROVIDE4" STRAIGHTARMSTRONGAXIOMPERIMETER TRIM AT ALL FLOATING ACOUSTICAL CEILING CLOUDS. ACOUSTICAL CEILING CLOUDS TO HAVE FULL SIZE TLLES. N ACTATMECHANICALouCTLOCATI0N5-REFERTO ARMSTRONG CEILINGS "TRAPESE" AND "STRONG BACK" SUPPORT oETAILS ANo MANUFACTURER INSTRUCTION TO SPAN GRID AT MECHANICAL DUCT LOCATIONS AS NEEDED. O UNLESSNOTE�OTHERWISE,ALLCEILINGSINDICATE�AS "EXPOSED" OR "E%POSED CEILING' ARE TO 8E PAINTED PT-0ODRVFALLPAINT. TREATALLDUCTWORK.CONDUIT AND OTHER COMPONENTRY TO MATCH THAT IN NORTH SUITE. ALLTRANSITIONSFROMEXPOSEDDECKTO VERTICAL DRVWALL TO BE CLEAN TO ENSURE DEFINED PAINTCUTLMEBETWEENTHEPNOSURFACES. ALL PENETRATIONS WTO BULKHEADS AND VERTICAL WALLS FROM OUCTS , CONOUIT ANO OTHER COMPONENTRV MUST BE WTERNAL SEALE� SVSTEM TO MSURE DEFlNED AND CLEAN TRANSITION. P WHERETHEPUBLICCORRIDORISMO�IREqEXTENDNEW GRI� CEILING FROM COftRI�OR TO ALIGN W ITH EXISTING. � GONFlRMALLTHERMOSTATLOGATIONSWITHTENANT PRIOR TO INSTALLATION. � PROJECTNO. I 19124.000 ''.�� � coarRicHrrvonce. rHisnacHirEcruan� AN�ENGINEERINGDRAWINGISGIVENIN GONRDENCEANDSHALLBEUSEDONLY y� PlIRSUANTTOTHEAGREEMENTWITHRATlO ARCHITECTS,INC. NOOTHERUSE, DiSSEMWATiON OR DUPLiCATiON MAY BE MADE W ITHOUT PRIOR W RITfEN CONSEIJr OF RATIO ARCHITEQS, INC. ALL COMMON RATIO OTHERWISEAOREHEREBYSPECIOFICALLV RESERVED. SHEET TITLE SECOND FLOOR REFLECTED CEILING PLAN SHEETNUMBER A-131