Loading...
HomeMy WebLinkAboutCarmel GN001i 8 BD. BOARD BITUM. BITUMINOUS BLDG. Bl11LDING — BIO BOTTOM OF 80W. BOTTOMOFWALL BSMT. BASEMENT C 0 INTERIOR PARTITION HEIGHT CODES P P.L. PROPERTYLME P. LAM PLASTIC LAMINATE PLAS. PLASTER PR. PAIR PREFA6. PREFABRICATED PT. BD. PARTICLE BOARO PTD. PAINTED PWD. PLYWOOD � O.T. QUARRVTILE U U.N.O. UNLESSNOTEDOTHERWISE UTIL. UTILITV U.V. UNITVENTILATOR V V.CT. VINVLCOMPOSITIONTILE VERT. VERTICAL VEST. VESTIBULE VIF VERIFV W RELD (0) TERMINATE AT FLOOR / ROOF DECK (P) PARTIAL HEIGHT:9'-4" � (C)TERMINATEATCEILINGISOFFIT HEIGHT AS IN�ICATE� IN MCHES OR (V) IN�ICATES HEIGHT ' FIRE R4TING AND ACOUSTICAL ATTENUATION WHEN RE�UIRED BV PARTITION SVMBOL S 1 FA GVPSUM WALL BOARD O E SIDE) LAVER 5/8" �� S3A XGVPSUMWALLBO RIDE(ACHSIDE58 T�PE � ' 1 HR RATED UL419 n,� ' ACOUSTIC ATTEN. COMPONENTS STC- NOTES: 1. USE THIS DETAIL TO LOCATE DEVICES THAT ARE INDICATED ON THE DRAWINGS BUT NOT LOCATEO BV DIMENSION, OR TO LOCATE REQUIRED DEVICES THAT ARE NOT INDICATEO ON THE DR4W INGS. 2. ALIGN MULTIPLE �EVICES HORIZONTALLV AND/OR VERTICALLV AS DETAILED. 3. ITEMS OTHER THAN ELECTRICAL RECEPTACLES SHALL BE MOUNTE� NEAR DOORWAVS OR MTERSECTING WALLS AS DETAILED SO AS NOT TO INTERFERE W ITH THE PLACEMENT OF ART OR FUNITURE - E%CEPT THAT W HERE THE WALL SEGMENT IS LE55 THAN 24" W IDE, CENTER THE OEVICES AS DETAILED. ABBREVIATIONS N NAF NOAPPLIEDRNWSH NJ.G NOT IN CONTRACT NO. NUMBER N T.S. NOT TO SCALE O G GA. GAUGE G.C. GENERALCONTRACTOR GEN. GENERAL GL GLASS G.WA/ GVPSUMWALLBOARD GWB H H. HEIGHT HB HOSE BIBB HDWR. HARDWARE H.M. HOLLOW METAL HORIZ. HORIZONTAL HT. HEIGHT HVAG HEATIN6.VENTILATION&A.C. H W. HOT WATER I 0. INSIOE DIAMETER WCAN. MCAN�ESCENT INFO. INFORMATION INSUL. MSULATION INT. INTERIOR J JAN. JANITOR J.C. JANITOR CLOSET JST. BRG. JOIST BEARING JT. JOINT L L LENGTH LAV. LAVATORV LB. POUND L.H. LEFTHAND LL.H. LONG LEG HORIZONTAL LLQ LONG LEG OUT LL.V. LONG LE6 VERTICAL M w w > t w� ti S SO>)u rn rnxwZO w a c'� c'��orco Z Z�I�F F F�r�a X Xwww?w W WZZZm� w wmmm�0 � �6Q60m LL LLUUUUQ 1 1 RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions o4S�a�eantlLocalCodes STANDARD-DEVICE MOUNTWG GUIDELINES City of Carmel '!,,:,,, 'a .�;va,�a� DATE: O3�Z7�2O I I INTERIOR PARTITION TYPES ww� F>g O�� �Wt/IW tnUKU apLL QaN� � KUwN UK�K ��OD WOU� Z --Il4Il--� � r a � tt� O� w UV a �a UW �U w¢ 2" --�o�—�� __ _ _ EARTH . i�.;,,-;,, GRANULAR FlLL � SAND.GROUT AS NOTED � CAST-IN-PLACE CONCRETE PRECAST CONCRETE, CAST STONE CONCRETE MASONRY UNIT � BRICK MASONRV STONE: LIMESTONE, GRANITE, �/���/� MARBLE OR AS NOTED TERRA COTTA, STRUCTURAL CLAVTRE � METAL TVPE AS NOTED � METAL ROLLEDSHAPES � WOODFRAMING/BLOCKING CONTINOUS � WOO�SHIM ARCHITECTURAL MATERIAL LEGEND �� FlNISHEDWO00 SHOW N CUT AND ELEVATION ENGWEERED WOOD: GLUE LAMINATED ���� �f� -- s WOODFLOORWOOD �If � " SHINGLES,ORSIDING � PARTICLEBOARD � PLVWO00 ,f�:T;,fj�; GLASSFlBERREMFORCED CONCRETE SIDING OR TRIM EIFS � SPRAVEDFIREPROOFING SHOWN ON ROLLED SHAPE C,C,C.0 C C C Y BATT INSULATION: THERMAL ,�,�J,�,�p A'J OR ACOUSTICAL, UNO RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING GVPSUM WALL BOAR� � PLASTER ON METAL LATH SHEATHING: GVPSl1M, OR AS NOTED ACOUSTICAL CEILING TILE RESINOUS FLOORING: TERRPZQ TROWEL-ON, UNO � -� TILE CERAMIC, �UARRV, UNO � CARPET,CARPETTILE�OETAIL) � GRATING SHOWN IN PLAN � GRATING — INSULATEDGLASS: (SMALL SCALE) � INSULATEDGLASS: (DETAIL) MEMBRANE:WATERPROOF, ROOF, OAMPPROOFING AIR BARRIER SVSTEM NOTE'. PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERW ISE ABOVE. ARCHITECTURAL SYMBOLS LEGEND W ALL END OR EDGE(WHERE OCCURS) I DOOR FRAME OR �I I WINDOWFRAME � � _ COWMNGRIDS ' A '. EXISTING ia l� NEW � ELEVATION DATUM REFERENCE If ^,� q��� ENLARGED DRAWING REFERENCE � � BUILDMG SECTION CUT REFERENCE � DRAWING NUMBER nim SHEETNUMBER WALL SECTION CUT REFERENCE � DRAWING NUMBER A�O� SHEETNUMBER ELEVATION REFERENCE � DftAWIN6 NUMBER q�o� SHEETNUMBEft FIRE ALARM THERMOSTAT OR � TEMPERATURE CONTROL -- - '1���� ----- J TELEPHONES,DOORSWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SW ITCHES ANO SIMILAR ITEMS � (THE INTENT IS TO ALIGN TOPS OF ALL OPERABLE ITEMS W HILE ALLOW IN6 THE OPERABLE PARTS TO BE LESS - ��THAN4'-0"AFF) e 1 J � ELECTRICALRECEPTACLES-SINGLE, � GANGED, OR SEPARATED BV 2" i � DOOR/DOORNl1M6ER i o � CT-7 KEV NOTE (SHAPE VARIES) wOia WINDOW NUMBER � ALIGNDESIGNATED SURFACES NORTHARROW �— INDICATES NORTH DIRECTION �j� , REVISION REFERENCE 1 ) W 1/4'VFOOT ROOFSLOPE-ARROW POINTS TOWARD DR41N Room Name ROOM NAME AND NUMBER 101 WALLENDOR I EDGE(WHERE I OCCURS) I WALL SEGMENT 24" W IDE OR LESS I EQ � Ea ❑ ❑ _ -- _�� _— I 2. WINDOW,DOOROR I� �� "FEATURE" THAT O � O SEPARATES WALL NTO SEGMENTS —�I PARTITION TVPE SYMBOL' �MBA.D 2 A �REFER TO INTERIOR PARTITION LEGEND 52A.P i � GENERAL ARCHITECTURAL NOTES A THESE GENERAL NOTES APPLV TO ARCHITECTURAL DRAW INGS. B I U G H O�SGS 1 1 OG B WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS y n SPECIFICALLV NOTED TO BE BV ALTERNATE BID. NOTE THAT SOI U lI OI I S AREAS NOT IN CONTRACT (N.ID.) ARE GREVED OUT. PoR CLARITV OF EGRE55 ROUTES, HALLWAVS, STAIRS AND LOBBIES HAVE NOT BEENGREYE�OUT.THESESPACESOl1T51�ETHETENANTAREA 11939 N. Meridian St. ARE NOT IN SCOPE. C FlELOVERIFYE%ISTINGFINISHFLOORELEVATIONSPRIORTO E%STING N�LESSNUTTEDO HERWISE FLOORELEVATIONSWITH Carmel, IN 46033 D DIMENSIONSTOEXISTINGCONSTRUCTIONARETOFINISH SURFACE. �IMENSIONSTONEWCONSTRIICTIONARETO STRUCTURAL CENTERLWE, FACE OF CONCRETE OR MASONRV CONSTRUCTION, OR TO FACE OF FINISH UNLESS NOTED OTHERWISE RELDVERIFVALLCONDITIONSANDDIMENSIONS ��ef PRIORTOSTARTINGWORKANDNOTIFVARCHITECTIMMEDIATELV BlueHorseshoeSolutions IF DISCREPANCIES ARE FOUND BETW EEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS. 11939 N. Me�idian Sfreet E DONOTSCALEDRAWINGS.REFERDIMENSION�UESTIONSTO Ca�meI,IN46033 ARCHITEQ FOR INTERPRETATION. (317) 730-2641 F DOORAN�FRAMENUMBERSCORRESPONDTO RESPECTNEROOM NUMBERS. IN ROOMS W ITH MULTIPLE OPENINGS, A SUFRX HAS AfChItCC[ BEEN ADDED TO OOOR NUMBERS, I.E., A101-6. jj/�TIO AfCF11iCCi5, IOC. G LOCATE INSIDE FACE OF DOOR FRAME OR WINDOW FRAME JAMBS 6 INCHES FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED pp� F2yZ@ZVIIIB SUBEI, SWfZ 301 OiHERwISE Raleigh, North Carolina 27601 H COOR�INATEEQUIPMENTWORKWITHMANUFACTURERSAND 919$21-0805 SUPPLIERS TO MSURE PROPER ROUGH-IN CLEARANCES FOR INSTALLATION, USE AND MAINTENANCE. I PROTECT EXISTMG SURFACES TO REMAIN THAT ARE NOT INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS OF CONSTRUCTION ACTIVITY. J PATCH,REPAIRAN�RESTOREEXISTINGFINISHESANDSURFACES TO "AS NEW CONDITION" AS REpUIRED TO MATCH SURROUNDING MATERIALS OR TO PROVI�E APPROPRIATE SUBSTRATE PRIOR TO INSTALLING NEW FlNISHES. AREAS NOTED TO BE PATCHED OR REPAIRED ON THE DRAWINGS ARE GVEN PoR REFERENCE AND SHALL NOT BE INTERPRETED TO LIMIT THE SCOPE OF WORK. K WOOD OR METAL STU� SPACING SHALL BE i6" ON CENTER UNLESS NOTED OTHERW ISE. L PROVIDEWATER-RESISTANTGVPSUMBOARDONWALLSWITH OPERABLE PLUMBING FlXTURES AND W ITHIN 4'-0" OF DRINKING FOUNTAINS OR WATER COOLERS. M PROVIDE RNISHED END PANELS, FlLLERS, SUPPORT$ ETC. REQUIREDFORACOMPLETECABINETRVMSTALL4TION. PROVIDE WTOUTS, ACCESS PANELS AND REMOVABLE COMPONENTS AS REQUIRED BV NEW OR EXISTING CONDITIONS SUCH AS ELECTRICAL OUTLETS, JUNCTION BOXES. CIEANOUTS, ETC. MOUNT TOP OF WALL CABW ETS AT +�'-0" A.F.F. UNLE55 OTHERWISE INDICATED. N VERIFVMOUNTINGHEIGHTSOFACCESSORIES,E�UIPMENT,DOOR HARDWARE, CASEWORK, ETC., AND PROVI�E SOLID BLOCKING BEHINDITEMSRE�UIRINGANCHORAGE PROVI�EFIRETREATED WOOD BLOCKING OR METAL STRAPS BETWEEN FRAMING MEMBERS AS REQUIRED TO SUPPORT W EIGHT AND USE OF ITEMS TOBESUPPORTED. WHEREMOUNTINGHEIGHTSARENOT INDICATED, MOUNT ITEMS IN ACCORDANCE W ITH RECOGMZED INDUSTRV STANDARDS, COOR�INATE LOCATIONS W ITH MANUFACTl1RER OR SUPPLIER AN� REFER MOUNTING HEIGHT �UESTIONS TO ARCHITECT FOR INTERPRETATION. O PROVIDESEALANTBETWEENAWMINl1MFRAMEPERIMETERSAND SURROUNDING WALL CONSTRUCTION UNLESS OTHERW ISE IN�ICATED. P PROVIDESEALANTBETWEENINTERIORANDEXTERIORWINDOW AND STOREFRONT FRAME PERIMETERS AND SURROUNDMG CONSTRUCTION UNLE55 OTHERW ISE INDICATED. Q PROVIDESEALANTeETWEEN�I551MILARMATERIALSSUCHAS GVPSUMBOAROAN�MASONRV,MASONRVANOCONCRETE, COUNTERTOPS AND wALLS, ETC. R VERIFV EXISTING RATED CONSTRUCTION W ITH SHELL CON�ITIONS/�RAW INGS 5 STAIRWELLS,ELEVATORHOISTWAVS,ELEVATORWUIPMENT ROOMS, AND SHAFT WALLS SHALL BE RATEO PER SHELL BWLDING DRAW ING& EXISTING TO REMAIN, REPAIR IF REQUIRED. T REPAIR AND PATCH SPRAYED FlRERESISTIVE AND FlRESTOP MATERIALS WHERE DAMAGED DUE TO INSTALLATION OF NEW MATERIALS TO RESTORE SPECIFlED FlRE RATING. ll DO NOT BEGIN WORK THAT MAV REpUIRE COORDINATION, SUCH AS CEILING INSTALLATION, PRIOR TO FlNAL SUBMITTAL OF MECHANICAL AND ELECTRICAL COORDINATION DRAW INGS TO ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF COORDINATION ISSUES. V REFERTOLIFESAFETYPLANDRAWINGSANDCODESUMMARVFOR FIRE-RATED FLOOR, WALL, CEILING AND ROOF LOCATIONS. INSTALL FIRESTOPPING AT PENETRATIONS IN RATED CONSTRUCTION AND AT TOPS OF RATED WALLS. INTERIOR PARTITION NOTES A ALLWALLSARETYPE53A.D.AUNLESSNOTEDOTHERWISE. B PARTITION SVMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN PROVIDED FOR AREA. C REFERTOFINISHANDCEILINGPLANSFORWALLFINISH,BASE, ANDCEILING WFORMATION. D PROVIDEWATERRESISTANTGWBINALLROOMSCONTAINING OPERABLE P W MBING FIXTURES AND W ITHIN 4 FEET OF DRINKING FOUNTAINS / W ATER COOLERS, U.N.O. E PROVIDELATERALBRACINGFORPARTITIONSWHICHEXTEND ABOVE CEILING. F PROVIDE FIRE RESISTNE RATED GVPSUM WALL BOARD ATALL RATED ASSEMBLIES TO MEET ASSEMBLV REpUIREMENTS. G PROVIDERRERESISTNEJOINTSVSTEMSE�UALTOWALL RATING AT ALL PENETRATIONS AND AT HEAD / FLOOR INTERSECTIONS WITH RATED ASSEMBLIES. H PROVIDEACOUSTICALSEALANTATWALLSILL,HEAD, PENETRATIONS AND ADDITIONAL SPEQFlED SOUND ATTENl1ATION COMPONENTS AT SOUND RATED WALLS. J PROVIDESPEQFIEDTILEBACKERBOARDATALLWALLS SCHEDULED TO HAVE CERAMIC TILE. K ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT TRANSFER OF VERTICAL LOADS W MLE PROVIDING LATERAL SUPPORT AS SPEGFIE�. L STUDSPACINGI6"O.C.UNLESSNOTEDOTHERWISE M ALL WALLS TO HAVE SOUND BATT INSULATION. INTERIOR PARTITION LEGEND �PARTITION DESIGNATION �PARTITION TYPE �FIRE RATING Q E. 1= 1 HOUR) ACOUSTICALATTENUATIONREQ'D MBA.D 2 A � PARTITIONHBGHTCODE 52A P � ADDITIONAL PARTITION DESIGNATION, WHEREOCCURS � NEW PARTITIONS � �-� EXISTING PARTITIONS TO REMAIN PARTITIONS TO BE DEMOuSHEo � CONSTRUCTION DOCUMENTS 04.04.2017 REISSUE CHECKEDBY APPROVEDBY Ip��� � 9? b,:- PROJECTNO. 19124.000 I ''.�� � coarRicHrrvonce. rHisnacHirEcruan� AN�ENGINEERINGDRAWINGISGIVENIN GONRDENCEANDSHALLBEUSEDONLY y� PlIRSUANTTOTHEAGREEMENTWITHRATlO ARCHITECTS INC. NOOTHERUSE, DiSSEMWATiON OR DUPLiCATiON MAY BE MADE W ITHOUT PRIOR W RITfEN CONSEIJr OF RATIO ARCHITEQS, INC. ALL COMMON RATIO OTHERWISEAOREHEREBYSPECIOFICALLV RESERVED. SHEET TITLE GENERAL NOTES, SYMBOLS, WALL LEGENDS SHEETNUMBER A-001 L ANGLE � CENTER LINE # NUMBER