HomeMy WebLinkAboutCarmel GN001i
8
BD. BOARD
BITUM. BITUMINOUS
BLDG. Bl11LDING
— BIO BOTTOM OF
80W. BOTTOMOFWALL
BSMT. BASEMENT
C
0
INTERIOR PARTITION HEIGHT CODES
P
P.L. PROPERTYLME
P. LAM PLASTIC LAMINATE
PLAS. PLASTER
PR. PAIR
PREFA6. PREFABRICATED
PT. BD. PARTICLE BOARO
PTD. PAINTED
PWD. PLYWOOD
�
O.T. QUARRVTILE
U
U.N.O. UNLESSNOTEDOTHERWISE
UTIL. UTILITV
U.V. UNITVENTILATOR
V
V.CT. VINVLCOMPOSITIONTILE
VERT. VERTICAL
VEST. VESTIBULE
VIF VERIFV W RELD
(0) TERMINATE AT FLOOR / ROOF DECK
(P) PARTIAL HEIGHT:9'-4"
� (C)TERMINATEATCEILINGISOFFIT
HEIGHT AS
IN�ICATE� IN
MCHES OR (V)
IN�ICATES HEIGHT
' FIRE R4TING AND ACOUSTICAL ATTENUATION
WHEN RE�UIRED BV PARTITION SVMBOL
S 1 FA GVPSUM WALL BOARD O E SIDE) LAVER 5/8"
��
S3A XGVPSUMWALLBO RIDE(ACHSIDE58 T�PE �
' 1 HR RATED UL419 n,�
' ACOUSTIC ATTEN. COMPONENTS STC-
NOTES:
1. USE THIS DETAIL TO LOCATE DEVICES
THAT ARE INDICATED ON THE
DRAWINGS BUT NOT LOCATEO BV
DIMENSION, OR TO LOCATE REQUIRED
DEVICES THAT ARE NOT INDICATEO ON
THE DR4W INGS.
2. ALIGN MULTIPLE �EVICES
HORIZONTALLV AND/OR VERTICALLV AS
DETAILED.
3. ITEMS OTHER THAN ELECTRICAL
RECEPTACLES SHALL BE MOUNTE�
NEAR DOORWAVS OR MTERSECTING
WALLS AS DETAILED SO AS NOT TO
INTERFERE W ITH THE PLACEMENT OF
ART OR FUNITURE - E%CEPT THAT
W HERE THE WALL SEGMENT IS LE55
THAN 24" W IDE, CENTER THE OEVICES
AS DETAILED.
ABBREVIATIONS
N
NAF NOAPPLIEDRNWSH
NJ.G NOT IN CONTRACT
NO. NUMBER
N T.S. NOT TO SCALE
O
G
GA. GAUGE
G.C. GENERALCONTRACTOR
GEN. GENERAL
GL GLASS
G.WA/ GVPSUMWALLBOARD
GWB
H
H. HEIGHT
HB HOSE BIBB
HDWR. HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HT. HEIGHT
HVAG HEATIN6.VENTILATION&A.C.
H W. HOT WATER
I 0. INSIOE DIAMETER
WCAN. MCAN�ESCENT
INFO. INFORMATION
INSUL. MSULATION
INT. INTERIOR
J
JAN. JANITOR
J.C. JANITOR CLOSET
JST. BRG. JOIST BEARING
JT. JOINT
L
L LENGTH
LAV. LAVATORV
LB. POUND
L.H. LEFTHAND
LL.H. LONG LEG HORIZONTAL
LLQ LONG LEG OUT
LL.V. LONG LE6 VERTICAL
M
w w
> t
w�
ti
S SO>)u
rn rnxwZO
w a
c'� c'��orco
Z Z�I�F
F F�r�a
X Xwww?w
W WZZZm�
w wmmm�0
� �6Q60m
LL LLUUUUQ
1 1
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
o4S�a�eantlLocalCodes STANDARD-DEVICE MOUNTWG GUIDELINES
City of Carmel
'!,,:,,, 'a .�;va,�a�
DATE: O3�Z7�2O I I
INTERIOR PARTITION TYPES
ww�
F>g
O��
�Wt/IW
tnUKU
apLL
QaN�
�
KUwN
UK�K
��OD
WOU�
Z
--Il4Il--�
�
r
a
�
tt�
O�
w
UV
a
�a
UW
�U
w¢
2"
--�o�—��
__ _ _ EARTH
. i�.;,,-;,, GRANULAR FlLL
� SAND.GROUT
AS NOTED
� CAST-IN-PLACE CONCRETE
PRECAST CONCRETE, CAST
STONE
CONCRETE MASONRY UNIT
� BRICK MASONRV
STONE: LIMESTONE, GRANITE,
�/���/� MARBLE OR AS NOTED
TERRA COTTA, STRUCTURAL
CLAVTRE
� METAL TVPE AS NOTED
� METAL ROLLEDSHAPES
� WOODFRAMING/BLOCKING
CONTINOUS
� WOO�SHIM
ARCHITECTURAL MATERIAL LEGEND
�� FlNISHEDWO00
SHOW N CUT AND ELEVATION
ENGWEERED WOOD: GLUE
LAMINATED
���� �f� -- s WOODFLOORWOOD
�If � " SHINGLES,ORSIDING
� PARTICLEBOARD
� PLVWO00
,f�:T;,fj�; GLASSFlBERREMFORCED
CONCRETE SIDING OR TRIM
EIFS
� SPRAVEDFIREPROOFING
SHOWN ON ROLLED SHAPE
C,C,C.0 C C C Y BATT INSULATION: THERMAL
,�,�J,�,�p A'J OR ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
GVPSUM WALL BOAR�
� PLASTER ON METAL LATH
SHEATHING: GVPSl1M, OR AS
NOTED
ACOUSTICAL CEILING TILE
RESINOUS FLOORING:
TERRPZQ TROWEL-ON, UNO
� -� TILE CERAMIC, �UARRV, UNO
� CARPET,CARPETTILE�OETAIL)
� GRATING
SHOWN IN PLAN
� GRATING
— INSULATEDGLASS:
(SMALL SCALE)
� INSULATEDGLASS:
(DETAIL)
MEMBRANE:WATERPROOF,
ROOF, OAMPPROOFING
AIR BARRIER SVSTEM
NOTE'. PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN
OR SECTION, UNLESS NOTED OTHERW ISE ABOVE.
ARCHITECTURAL SYMBOLS LEGEND
W ALL END OR
EDGE(WHERE
OCCURS) I
DOOR FRAME OR �I I
WINDOWFRAME � �
_ COWMNGRIDS
' A '. EXISTING
ia l� NEW
� ELEVATION DATUM REFERENCE
If ^,�
q��� ENLARGED DRAWING REFERENCE
� �
BUILDMG SECTION CUT REFERENCE
� DRAWING NUMBER
nim SHEETNUMBER
WALL SECTION CUT REFERENCE
� DRAWING NUMBER
A�O� SHEETNUMBER
ELEVATION REFERENCE
� DftAWIN6 NUMBER
q�o� SHEETNUMBEft
FIRE ALARM
THERMOSTAT OR
� TEMPERATURE CONTROL
-- - '1���� -----
J TELEPHONES,DOORSWITCHES,
DOOR CONTROLLERS, FIRE ALARM
PULL SW ITCHES ANO SIMILAR ITEMS
� (THE INTENT IS TO ALIGN TOPS OF ALL
OPERABLE ITEMS W HILE ALLOW IN6
THE OPERABLE PARTS TO BE LESS -
��THAN4'-0"AFF) e
1
J
� ELECTRICALRECEPTACLES-SINGLE,
� GANGED, OR SEPARATED BV 2"
i
� DOOR/DOORNl1M6ER
i o
� CT-7 KEV NOTE (SHAPE VARIES)
wOia WINDOW NUMBER
� ALIGNDESIGNATED
SURFACES
NORTHARROW
�— INDICATES NORTH DIRECTION
�j� , REVISION REFERENCE
1 )
W
1/4'VFOOT ROOFSLOPE-ARROW
POINTS TOWARD DR41N
Room Name ROOM NAME AND NUMBER
101
WALLENDOR I
EDGE(WHERE I
OCCURS) I
WALL SEGMENT 24" W IDE OR LESS I
EQ � Ea
❑ ❑ _
-- _�� _—
I 2.
WINDOW,DOOROR I� ��
"FEATURE" THAT O � O
SEPARATES WALL
NTO SEGMENTS —�I
PARTITION TVPE SYMBOL'
�MBA.D 2 A �REFER TO INTERIOR PARTITION LEGEND
52A.P
i �
GENERAL ARCHITECTURAL NOTES
A THESE GENERAL NOTES APPLV TO ARCHITECTURAL DRAW INGS. B I U G H O�SGS 1 1 OG
B WORK SHOWN ON THE DRAWINGS SHALL BE BASE BID UNLESS y n
SPECIFICALLV NOTED TO BE BV ALTERNATE BID. NOTE THAT SOI U lI OI I S
AREAS NOT IN CONTRACT (N.ID.) ARE GREVED OUT. PoR CLARITV
OF EGRE55 ROUTES, HALLWAVS, STAIRS AND LOBBIES HAVE NOT
BEENGREYE�OUT.THESESPACESOl1T51�ETHETENANTAREA 11939 N. Meridian St.
ARE NOT IN SCOPE.
C FlELOVERIFYE%ISTINGFINISHFLOORELEVATIONSPRIORTO
E%STING N�LESSNUTTEDO HERWISE FLOORELEVATIONSWITH Carmel, IN 46033
D DIMENSIONSTOEXISTINGCONSTRUCTIONARETOFINISH
SURFACE. �IMENSIONSTONEWCONSTRIICTIONARETO
STRUCTURAL CENTERLWE, FACE OF CONCRETE OR MASONRV
CONSTRUCTION, OR TO FACE OF FINISH UNLESS NOTED
OTHERWISE RELDVERIFVALLCONDITIONSANDDIMENSIONS ��ef
PRIORTOSTARTINGWORKANDNOTIFVARCHITECTIMMEDIATELV BlueHorseshoeSolutions
IF DISCREPANCIES ARE FOUND BETW EEN CONTRACT DOCUMENTS
AND ACTUAL FIELD CONDITIONS. 11939 N. Me�idian Sfreet
E DONOTSCALEDRAWINGS.REFERDIMENSION�UESTIONSTO Ca�meI,IN46033
ARCHITEQ FOR INTERPRETATION. (317) 730-2641
F DOORAN�FRAMENUMBERSCORRESPONDTO RESPECTNEROOM
NUMBERS. IN ROOMS W ITH MULTIPLE OPENINGS, A SUFRX HAS AfChItCC[
BEEN ADDED TO OOOR NUMBERS, I.E., A101-6. jj/�TIO AfCF11iCCi5, IOC.
G LOCATE INSIDE FACE OF DOOR FRAME OR WINDOW FRAME JAMBS
6 INCHES FROM FINISH FACE OF ADJACENT WALLS UNLESS NOTED pp� F2yZ@ZVIIIB SUBEI, SWfZ 301
OiHERwISE Raleigh, North Carolina 27601
H COOR�INATEEQUIPMENTWORKWITHMANUFACTURERSAND 919$21-0805
SUPPLIERS TO MSURE PROPER ROUGH-IN CLEARANCES FOR
INSTALLATION, USE AND MAINTENANCE.
I PROTECT EXISTMG SURFACES TO REMAIN THAT ARE NOT
INCLUDED IN SCOPE OF WORK BUT THAT ARE WITHIN AREAS OF
CONSTRUCTION ACTIVITY.
J PATCH,REPAIRAN�RESTOREEXISTINGFINISHESANDSURFACES
TO "AS NEW CONDITION" AS REpUIRED TO MATCH SURROUNDING
MATERIALS OR TO PROVI�E APPROPRIATE SUBSTRATE PRIOR TO
INSTALLING NEW FlNISHES. AREAS NOTED TO BE PATCHED OR
REPAIRED ON THE DRAWINGS ARE GVEN PoR REFERENCE AND
SHALL NOT BE INTERPRETED TO LIMIT THE SCOPE OF WORK.
K WOOD OR METAL STU� SPACING SHALL BE i6" ON CENTER UNLESS
NOTED OTHERW ISE.
L PROVIDEWATER-RESISTANTGVPSUMBOARDONWALLSWITH
OPERABLE PLUMBING FlXTURES AND W ITHIN 4'-0" OF DRINKING
FOUNTAINS OR WATER COOLERS.
M PROVIDE RNISHED END PANELS, FlLLERS, SUPPORT$ ETC.
REQUIREDFORACOMPLETECABINETRVMSTALL4TION. PROVIDE
WTOUTS, ACCESS PANELS AND REMOVABLE COMPONENTS AS
REQUIRED BV NEW OR EXISTING CONDITIONS SUCH AS
ELECTRICAL OUTLETS, JUNCTION BOXES. CIEANOUTS, ETC.
MOUNT TOP OF WALL CABW ETS AT +�'-0" A.F.F. UNLE55
OTHERWISE INDICATED.
N VERIFVMOUNTINGHEIGHTSOFACCESSORIES,E�UIPMENT,DOOR
HARDWARE, CASEWORK, ETC., AND PROVI�E SOLID BLOCKING
BEHINDITEMSRE�UIRINGANCHORAGE PROVI�EFIRETREATED
WOOD BLOCKING OR METAL STRAPS BETWEEN FRAMING
MEMBERS AS REQUIRED TO SUPPORT W EIGHT AND USE OF ITEMS
TOBESUPPORTED. WHEREMOUNTINGHEIGHTSARENOT
INDICATED, MOUNT ITEMS IN ACCORDANCE W ITH RECOGMZED
INDUSTRV STANDARDS, COOR�INATE LOCATIONS W ITH
MANUFACTl1RER OR SUPPLIER AN� REFER MOUNTING HEIGHT
�UESTIONS TO ARCHITECT FOR INTERPRETATION.
O PROVIDESEALANTBETWEENAWMINl1MFRAMEPERIMETERSAND
SURROUNDING WALL CONSTRUCTION UNLESS OTHERW ISE
IN�ICATED.
P PROVIDESEALANTBETWEENINTERIORANDEXTERIORWINDOW
AND STOREFRONT FRAME PERIMETERS AND SURROUNDMG
CONSTRUCTION UNLE55 OTHERW ISE INDICATED.
Q PROVIDESEALANTeETWEEN�I551MILARMATERIALSSUCHAS
GVPSUMBOAROAN�MASONRV,MASONRVANOCONCRETE,
COUNTERTOPS AND wALLS, ETC.
R VERIFV EXISTING RATED CONSTRUCTION W ITH SHELL
CON�ITIONS/�RAW INGS
5 STAIRWELLS,ELEVATORHOISTWAVS,ELEVATORWUIPMENT
ROOMS, AND SHAFT WALLS SHALL BE RATEO PER SHELL BWLDING
DRAW ING& EXISTING TO REMAIN, REPAIR IF REQUIRED.
T REPAIR AND PATCH SPRAYED FlRERESISTIVE AND FlRESTOP
MATERIALS WHERE DAMAGED DUE TO INSTALLATION OF NEW
MATERIALS TO RESTORE SPECIFlED FlRE RATING.
ll DO NOT BEGIN WORK THAT MAV REpUIRE COORDINATION, SUCH
AS CEILING INSTALLATION, PRIOR TO FlNAL SUBMITTAL OF
MECHANICAL AND ELECTRICAL COORDINATION DRAW INGS TO
ARCHITECT NOR PRIOR TO RESOLUTION AND APPROVAL OF
COORDINATION ISSUES.
V REFERTOLIFESAFETYPLANDRAWINGSANDCODESUMMARVFOR
FIRE-RATED FLOOR, WALL, CEILING AND ROOF LOCATIONS.
INSTALL FIRESTOPPING AT PENETRATIONS IN RATED
CONSTRUCTION AND AT TOPS OF RATED WALLS.
INTERIOR PARTITION NOTES
A ALLWALLSARETYPE53A.D.AUNLESSNOTEDOTHERWISE.
B PARTITION SVMBOLS APPEAR ON LARGEST SCALE FLOOR PLAN
PROVIDED FOR AREA.
C REFERTOFINISHANDCEILINGPLANSFORWALLFINISH,BASE,
ANDCEILING WFORMATION.
D PROVIDEWATERRESISTANTGWBINALLROOMSCONTAINING
OPERABLE P W MBING FIXTURES AND W ITHIN 4 FEET OF
DRINKING FOUNTAINS / W ATER COOLERS, U.N.O.
E PROVIDELATERALBRACINGFORPARTITIONSWHICHEXTEND
ABOVE CEILING.
F PROVIDE FIRE RESISTNE RATED GVPSUM WALL BOARD ATALL
RATED ASSEMBLIES TO MEET ASSEMBLV REpUIREMENTS.
G PROVIDERRERESISTNEJOINTSVSTEMSE�UALTOWALL
RATING AT ALL PENETRATIONS AND AT HEAD / FLOOR
INTERSECTIONS WITH RATED ASSEMBLIES.
H PROVIDEACOUSTICALSEALANTATWALLSILL,HEAD,
PENETRATIONS AND ADDITIONAL SPEQFlED SOUND
ATTENl1ATION COMPONENTS AT SOUND RATED WALLS.
J PROVIDESPEQFIEDTILEBACKERBOARDATALLWALLS
SCHEDULED TO HAVE CERAMIC TILE.
K ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING
STRUCTURE TO PREVENT TRANSFER OF VERTICAL LOADS
W MLE PROVIDING LATERAL SUPPORT AS SPEGFIE�.
L STUDSPACINGI6"O.C.UNLESSNOTEDOTHERWISE
M ALL WALLS TO HAVE SOUND BATT INSULATION.
INTERIOR PARTITION LEGEND
�PARTITION DESIGNATION
�PARTITION TYPE
�FIRE RATING Q E. 1= 1 HOUR)
ACOUSTICALATTENUATIONREQ'D
MBA.D 2 A
� PARTITIONHBGHTCODE
52A P
� ADDITIONAL PARTITION
DESIGNATION, WHEREOCCURS
� NEW PARTITIONS
�
�-�
EXISTING PARTITIONS TO REMAIN
PARTITIONS TO BE DEMOuSHEo
�
CONSTRUCTION DOCUMENTS
04.04.2017
REISSUE
CHECKEDBY
APPROVEDBY Ip���
�
9? b,:-
PROJECTNO.
19124.000 I
''.�� � coarRicHrrvonce. rHisnacHirEcruan�
AN�ENGINEERINGDRAWINGISGIVENIN
GONRDENCEANDSHALLBEUSEDONLY
y� PlIRSUANTTOTHEAGREEMENTWITHRATlO
ARCHITECTS INC. NOOTHERUSE,
DiSSEMWATiON OR DUPLiCATiON MAY BE
MADE W ITHOUT PRIOR W RITfEN CONSEIJr
OF RATIO ARCHITEQS, INC. ALL COMMON
RATIO OTHERWISEAOREHEREBYSPECIOFICALLV
RESERVED.
SHEET TITLE
GENERAL NOTES,
SYMBOLS, WALL
LEGENDS
SHEETNUMBER
A-001
L ANGLE
� CENTER LINE
# NUMBER