HomeMy WebLinkAboutCarmel LS200� u u CODESUMMARY u 2014 INDIANA BUILDING CODE, (2012 INTERNATIONAL BUILDING CODE & LOCAL AMENDMENTS) 2014 INDIANA FIRE CODE, (2012 INTERNATIONAL FIRE CODE & LOCAL AMENDMENTS) 2009 INDIANA ELECTRICAL CODE (2008 NATIONAL ELECTRICAL CODE AND LOCAL AMENDMENTS) 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE AND LOCAL AMENDMENTS) 2010 INDIANA PLUMBING CODE (2012 INTERNATIONAL PLUMBING CODE AND LOCAL AMENDMENTS) OCCUPANCY CLASSIFICATION OF NEW CONSTRUCTION- B(BUSINESS) AREA (NEW TENANT SPACE): ACTUAL: 2nd= 7,896, 3rd=20,235 (does not include exist shell spaces) ALLOWABLE: 86,250 per floor CODE STRATEGY: CONSTRUCTION TYPE SPRINKLER SYSTEM EGRESS CORRIDORS: EXIT TRAVEL DISTANCE FIRE ALARM SYSTEM FIRE SEPERATION INTERIOR BUILDOUT WITHIN EXISTING BUILDING TYPE II-B EQUIPPED THROUGHOUT WITH AND AUTOMATIC SPRINLER SYSTEM IN ACCORDANCE WITH 903.3.1.1 NOT REQUIRED TO BE RATED NOT TO EXCEED 300FT PROVIDED NOT REQUIRED WITHIN SCOPE OF WORK u 3NCLOSURE I�[N41.YIl:iy 0 GENERAL LIFE SAFETY PLAN NOTES A REFER TO DOOR SCHEDULE FOR REQl11RED DOOR RATING. B REFER TO INTERIOR PARTITION TVPES AND FLOOR PLAN FOR ADDITIONAL PARTITION REpUIRMENTS INCWDWG WALL HEIGHT, UL DESIGN, AND FIRE RATING. C REFER TO FLOOR PLANS FOR FIRE EXTINGUISHER LOCATIONS LIFE SAFETY PLAN LEGEND RM NAME� ROOMNAME,AREAB iSOSF OCCUPANTCAPACITV � EXIT DIRECTION ARROW 44 EXITPOPULATION 240 EXITCAPAQTV[POPULATION] e--� PATHOFTRAVEL —2-21—P— �FIRERATEOWALL } RATINGREQUIRE0.3PMIN,1-HR, 2-HR, ETC. •3S•315•35• � SMOKEBARRIER } RATIN6IFREQUIRED..1-HR,2-HR,ETC. �`�. ` `�� FlFE RATED WALL PATTERN INDICATESCODE RWUIRED SEPARATION AS NOTED � FlREBA._.� FlRESEPARATIONANDOTHER ANNOTATION SO NOTED � � FlRERATEDCEILING.RATINGAS NOTED...1-HR, 2-HR, ETC. OCCUPANT LOAD: 4,460 S.F. TRAVEL DISTANCE SCHEDULE EXIT ROUTE DISTANCE TRAVELDIST. A 89'-0" TRAVELDIST. B 209'-10" � GENERAL PROJECT NOTES A THE FOLLOW ING GENERAL NOTES APPLV TO THESE CONTRACT DOCUMENTS AND ARE NOT SPECIRC TO ANV ONE DISCIPLME. B ITISTHECONTRACTORSRESPONSIBILITYTOREVIEWANDCOORDINATETHE W ORK OF ALL SUB-CONTRACTORS, TRADES AND SUPPLIERS W ITH THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENQNG CONSTRUCTION, AND TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLE55 OF W HERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, W HICH MIGHT AFFECT THE WORK OF THAT PARTY. C PARTIALSETSOFORAWINGSAREINCOMPLETEANDSHOULDNOTBE DISTRIBUTED OR UTILRED BV THE CONTRACTOR. D THECONSTRl1CTIONDOCUMENTSESTABLISHDETAILEDMINIMUM REQUIREMENTS FOR THE CONSTRUCTION OF THE PROJECT. E THE GENERAL NOTES, SVMBOLS AND DEFINITIONS APPLICABLE ONLV TO EACH DISCIPLINE CAN BE FOUND AT THE FRONT OF EACH DISCIPLINES PORTION OF THE SET OF DRAW INGS AND IS LISTED AS PART OF THE OVERALL PROJECT INOEX OF DRAW W G5. F BASIC FIRE PROTECTION AND THE EXITING SCHEME ARE ILLUSTRATED BV THE EGRESS PLAN(5) AND APPLICABLE RRE AND BUILDING COOE SUMMARV ON SHEET G-002. G THEARCHITECTURALDRAWINGSESTABLISH,COORDINATEASWELLASTAKE PRECEDENCE FOR THE FINISH APPEARANCE OF ALL EXPOSE� ELEMENTS OF THE W ORK OF ALL TRADES MC W DING THAT W ORK W HICH IS ILLUSTRATED PRIMARILV ON DRAWINGS OF OTHER DISCIPLINES H THEDRAWINGSMAVMAKEREFERENCETOAND/ORILLUSTRATEITEMSWHICH ARE NOT PART OF THE WORK OF THE CONTRACT. THESE "NOT IN CONTRACT" ITEMS ARE REFERENCED AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION AND COORDINATION ONLY. J THECONTRACTORISRESPONSIBLETOCOMPLVWITHAPPLICABLELAWS. CODES, REGULATIONS AND ORDINANCES OF THE PLACE (CITY, COUNTV, DISTRICT AND STATE) WHERE THE PROJECT IS LOCATED -ALTHOUGH SUCH REQUIREMENTS MAV NOT BE RERECTED BV THESE CONTRACT DOCUMENTS. L THECONTRACTORSHALLOBTAINALLREpUIREDPERMITSANDSIMILAR RELEASES RE�UIRED FOR THE CONSTRUCTION AND OCCUPANCV OF THE PROJECT. THE CONTRACTOR SHALL FURNISH COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT W ITHIN 10 DAVS OF RECEIPT OF SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN W N�ITIONS OR REVISIONS TO THE WORK OR IF PERMITS ARE DELAVED FOR ANY REASON, THE CONTRACTOR SHALL NOTIFV THE OW NER AND ARCHITECT. M THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW WORK AS WELL AS EXISTING SVSTEMS AND ELEMENTS WHICH ARE TO REMAIN. ANV DAMAGE TO SUCH SVSTEMS AND ELEMENTS SHALL BE IMMEDIATELV REPAIRED IN A MANNER ACCEPTABLE TO THE ARCHITECT. IF SATISFACTORV REPAIRS CANNOT BE MAOE, THE CONTRACTOR SHALL REPLACE SVSTEMS AND ELEMENTS W ITH "LIKE NEW" QUALITY ACCEPTABLE TO THE ARCHITECT. ALL REPAIRS AND REPLACEMENT COST SHALL BE THE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. DRAWING INDEX Sheet # Sheet Name GENERAL G-002 SHEET INDEX, PROJ LOCATION, CODE SUMMARY AND LIFE SAFEN PLAN ARCHITECTURAL A-001 GENERAL NOTES, SYMBOLS, WALL LEGENDS A-101 SECOND FLOOR PLAN A-121 FURNITURE PLAN FOR REFERENCE ONLY A-131 SECOND FLOOR REFLECTED CEILING PLAN A-151 SECOND FLOOR FINISH PLAN A-211 INTERIOR ELEVATIONS MECHANICAL M-1 SECOND FLOOR PLAN- MECHANICAL ELECTRICAL E1 SECOND FLOOR LIGHTING PLAN E2 SECOND FLOOR POWER PLAN E3 DETAILS AND SCHEDULES Blue Horseshoe SOIUtIOC1S 11939 N. Meridian St. Carmel, IN 46033 Blue Horseshoe Solutions 11939 N. Meridian Street Carmel, IN 46033 (317)730-2641 RATIO Architects, Inc. 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 CONSTRUCTION DOCUMENTS 02.28.2020 REISSUE RELEA5E0 FOR CONSTRUCTION Suhjec� �o compliance with all regula�ions 04 S�a�e antl Local Codes City of Carmel �!,,:,� �;va�n�! DATE: 03�Z��2O i i i i PROJECT LOCATION ' II9 II6 � ���q4 k 5` a 2�e��0�a� Carmel ii� E 126iN 51 O 3 11939 N — Meritlian St n �Y/ll6th9 E116tM151 Ell6�F5t y _ _ 3 3 a — - Ulo�� L — V Ccuniry�Cli.b C�wkWS�irh 4 � � �+ �o�,<<�e � ��m� P,a�� � � 31 Z j n_ _____. n_ e�i - /. �65�33 y,�. . �. � W 96tM1 SI � ���,, ri CHECKEDBY APPROVEDBY l�lo I j�. n? cz:- PROJECTNO. 19124.000 ''.�� � COPVRIGHTNOTICE'. THISARCHITWTURAL AN�ENGINEERINGDRAWINGISGIVENIN GONRDENCEANDSHALLBEUSEDONLY 'y� auasunrvrromEncreEEMErvrwirHrenrio ARCHITECTS INC. NOOTHERUSE, DiSSEMWATiON OR DUPLiCATiON MAY BE MADE W ITHOUT PRIOR W RITfEN CONSEIJr OF RATIO ARCHITEQS, INC. ALL COMMON RATIO OTH RIWISEAOREHEREBYSPECIOFICALLV RESEavED. SHEET TITLE SHEET INDEX, PROJ LOCATION, CODE SUMMARY AND LIFE SAFETY PLAN SHEETNUMBER G-002