Loading...
HomeMy WebLinkAboutCarmel M201� i a"o �I� � � �� � �n CD1 12"fl 400 CFM � RG1 � TB-2-12 1100 CFM ia"m �_— TB-2i14 1150 ICFM I� SRq 12x8 20 CFM i a"m sn � m CD1 10" R�2 25� � I III i a"o sn �,�; �_��1� II I4: '�t a"m sa � �� - � — _ — — _ — _ _ _ _ _— � TB-2-09 W1 6"4 750 CFM 75 CFM� _ f�J1�E CD7 8"0 17'6� . �� %C/ 200 FM � GDi 80 200 CFM - 10 0 li _ � m � � � �� �- RG2��i: � �— RG2 RG2 � I , ' I..r.-,.- � wi s"o1 � 75 CFM � � I CD7 10"0 co> >o°o I — i— — — -- coi io"m �R 25� CFM I 250 CF I 250 CFM N I I CD1 10"0 � CD1 10"4 � � CD1 10"4 C�1 10"0 � 250 CFM ' 2`3�� 'I TB-2-15 16"m ' 2`3�� I �� I 1200 CFM SR1 12x8 T� 300 CFM � � 1200 CFM �i � 10°0 II 14"4 ��II 10"6 I 12��0 I � II � SR1 iBx6 I SR1 12x8 I SR1 12x8I SR1 12x8I SR1 12x8 I SR1 12x8I SR1 12x8 I 300 CFIA 300 CFM 300 CFM I 300 CFM 300 CFM 300 CFM I 300 CFIA —�L�—�'��—�'� - c---� — - r_— - �-- — - - __ - — - — � � � � � � � E r` F F.5 G "` H �� FLOOR PLAN - MECHANICAL e 16 � O �\ — — 2�6 — 8 — — — � AIR DEVICE SCHEDULE DESIGN BASIS NECK FRAME NUMBER TAG iYPE SIZE SIZE PATTERN OF MATERIAL RNISH REMARKS/NOTES MANUFACiURER MODELNUMBER IN IN SLOTS CDt PRICE SCD SUPPLY REF PLAN 24X24 4-WAY WA STEEL WHITE 1 RG1 PRICE 80 RETURN REF PLAN 24X24 EGGCR4TE fWA STEEL WHITE 1,3 RG2 PRICE 80 RETURN REF PLAN 24X12 EGGCRATE WA STEEL WHITE 1,3 REMARKS/NOTES 1. LAY-IN 3. SOUND BOOT 2.DUCTMOUNTED BASED ON MIN. 20% OA FROM CENTRAL AHU VENTILATION AIR SCHEDULE TABLE 64 TABLE 6-1 TABLE 6-1 TABLE 6-� ROOM ROOM Az OCCUPANCV OCCUPANT Pz Rp Ra Ra Vbz Voz DESIGN OUTSIDE SVSTEM ACTUAL NUMBER NAME AREA CLASSIFICA�ON DENSITI' POPULATION PEOPLE AREA AREA OUTSIDE AIR OUTSIDE AIR CFM AIR % % OUTSIDE OUTSIDE AIR NOTES 0 0 0 PEOPLEI1000 SF OUTSIDE AIR OUTSIDE AIR OUTSIDE AIR CALC CFM REQUIRED REQUIRED AIR CFM f51DE VENTILATION AIR OESIGN PER ASHRAE STANOARO 62.180161N ACCORDANCE WITH OMC SECTION 403.1 ANO IMC SECTION E03.3 Vbz =(Rp' Pz) +(Ra' Az) Vbz = BREATHING ZONE OUTDOOR AIR FLOW Rp = OUTDOOR AIR FLOW RATE PER PERSON (TABLE fi-1) Pz = ZONE POPULATION - MAk7MUM OCCUPANCY (TABLE 6-1) Ra = OUT�OOR AIR FLOW RATE PER UNIT AREA (TABLE 6-i) Az = ZONE FLOOR AREA Voz = Vbz I Ez Voz = ZONE OUTDOOR AIR FLOW Vbz = BREATHING ZONE OUiDOORAIR FLOW (CALCULATED) Ez = ZONE AIR DISiF21BUilON EFFECPVENE% (TABLE 6d) Ez = 0.80 (BASE� ON CEILING SUPPLY, CEILING RETl1RN) RELEA5E0 FOR CON$TRUCTION E� _, o �enseo oN ceiuNc suPP�v, �ow ReTURN� Su6ject�o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 03�27�20 ^ TR.4NSFER AIR IS PERMITTE� TO PROVIOE MAK6UP AIR TO KITCHENS, BATHS, TOILET ROOMS, ELEVATORS, AND SMOKING LOUNGES. T}1E AMOUNT OF TRANS FER AIR AND EkHAUSTAIR SHALL BE SUFFIQENTTO PROVIDE FLOW R4TES AS SPECIFIED IN TABLE 4033. �OORS SHALL BE UNOERCUT 1". OR DOOR GRILLES OF SUFFICIENT SIZE SHALL BE PROVIDED BV GENER4L GONTRAGTOR. O KEYNOTES 1 ROUTE 36x18 TRANSFEft DUCT ABOVE CEILING AND ACRO55 CORRIDOft. PROVIDE TRANSFER GRILLE TG-1 ON EACH END. � � z a 0 � � o w� w �� � _ � 'm m Y c� 0 w ^ o � n � � �� 0 U � a U` w t�W =N XV O`� W m�Z �- L wo�a� �oaLLg' w` w _inog W ����� � � Q r N � � Z N m m U ? r M n M � �� `� NU.nin Z J � a � M � � z Z O � = 0 � � � � �-J�Z Q O m � W Z � � Z � UJ � � m � rn U w � � SHAPE I PRE55. I DUCT MATERIAL I INS. TVPE I INS. AMT. DUCT CONSTRUCTION BY PRESSURE CLPSS JOB NO.: SCALE AS NOTED REQANGUL4RPRESSURECL455 DATe 2-14-20 A55 L4R6ESTDIM. CONNEQOR DRnWN Br: CKB /2" 4'• 36" 5&D /2" 37"-120" TDC APPROVEo BY: CSL S�� 4�� ?H�� SRD DRAWING NUMBER: 1" 29"- 120" TDC Z, 4. zo� s&o M_ � 2" 21"- 120" TDC 3'• 4'•-18" 5&D 3" 19"_t20" TDL REVISION NO.: 0