Loading...
HomeMy WebLinkAboutE0.1 Electrical SchedulesSYMBOL LLU � W Vll K � WIRING (OUTLET) DEVICE SYMBOL LEGEND DESCRIPTION DUPLE% RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDWG ttPE MOUNTED AT 18" AFF UNLE55 NOTED OTHERWISE DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING ttPE AIOUNTED AT 18" AFF UNLESS NOTED OTHERW6E GFCI GROUND iYPE �UPLE% RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING IYPE MOUNTED AT 18° AFF UNLE55 NOTED OTHERWISE RECEPTACLE SYMBOL WITH AD�ITIONAL SUBSCRIPT DESIGNATES IYPE OR SPEQFlC REQUIREMEN7S AS FOLLOWS: "+48" RECEPTACLE MOUNTED AT HEIGHT INDICATED JUNCiION BOX - SIZE PER N.E.C. ARTICLE 314 REOUIREMENTS SYMBOL � LIGHTING CONTROLS SYMBOL LEGEND oEscRiPrioN LIGHT SWITCH. SINGLE POLE, 20 AA�PERE, 120/277 VOLT, 1HP. �. LIGHi SWITCH. '%" INDICATES THE FOLLOWMG "a" CONTROL OF INDICATED LUMINAIRES 'VD" WALLBOx PIR VAVANCY SENSOR WITH 0-10V DIMMING AND AIABIENT LIGHT DETECTION SENSOR. LUTRON �MS-Z101-V-WH 'VS' WALLBOx DUAL TECHNOLOGY VACANCY SENSOR WIiH AMBIENT LIGHT DETECTION. LUTRON MAESTRO �IAS-A102-V-WH TELECOMMUNICATION OUTLET SYMBOL LEGEND SYMBOL DESCRIPTION V COMBINATION VOICE/DATA OUTLEf (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLEfE WITH SINGLE GANG DRY WALL RMG (VERIFY DRYWALL THICKNESS) MOUNTED AT 18' AEF. PROVIDE 3/4' CON�UIT WITH INSUUTING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. LUMINAIRE SCHEDULE IAMPS IAANUFACTURER IYPE WATfAGE VOLTAGE OESCRIPTION AND CATALOG REMARKS No. TYPE NUMBER LED 2'x2' RECESSED LUMINAIRE WITH 4EEL HOUSING AND CENTER CLEAR ACRYLIC LITHONIA LIGHTING: F2 B LED 35 UNV DIFFUSER. STANDARD 0-10V DIMMING DRIVER. �2VR2-40L-ADP-EZI-LP835 350�'K SAME AS ttPE "F2B" E%CEPT WITH SELF CONTAINED EMERGENCY BATfERY PACK LITHONIA LIGHTING: FZ B E - �E� 35 UNV {�2��-40L-ADP-EZI-LP835-EL14L J500'K LED RECESSED OPEN WALL WASH �OWNLIGHT WITH 4" SQUARE APERTURE, GOTHAM: F4A _ LED p� UNV SELF-FLANGE� SEMI-SPECULAR, MATfE-DIFFUSE LOWER REFLECTOR, AND STANDAR� �EVO SOLW-35/10-4AR-L�-277 J500'K 0-1�V �IMMING �RIVER. LED 30' ON�ER CABWEf WMINAIRE WITH EX�RU�ED AWMINUM HOOSING, SOLID MEfAL JUNO: NOTE 7 F6 _ LED �� �Zp FRONT, UV IMPACT RESISTANT ACRYLIC LENS, IMEGRATED OCCUPANCY SENSOR AN� �UPLED30-OC-WH 3000'K ROCKER SWITCH. SAIAE AS NPE 'F' E%CEPT WITHOUT OCCUPANCY SENSOR OR ROCKER SWITCH. JUNO: NOiE 7 F6A - LED �� �Zp �UPLED30-NS-WH 300�'K SAME AS ttPE 'F' EXCEPT WITHOUT OCCUPANCY SENSOR OR ROCKER SWITCH AND 22" JUNO: NOTE 7 F/�8 - �gp g �Zp W LENGTH. {�UPLE�22-NS-WH �� J000'K 1. THE ELECTRICAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO COORDINATE AND VERIFY WITH THE ARCHITECT AND ALL ARCHRECTURAL DRAWINGS SUCH AS FLOOR PLANS, CEILING PLANS, SCHE�ULES, ELEVATIONS, SECTIONS, DEfAILS, EfG ALL CEILING ttPES CONFIGURATIONS AND SPECIFICATIONS LUMINAIRE COLORS AND FINISHES LENGTHS TRIMS MOUNTINGS MOUNTING SYSTEMS HARDWARE LUMINAIRE CONFIGURATIONS SttLES SHAPES HEIGHT OF SUSPENDED AND � � � WALL MOUNTED LUMINAIRES, EfC. PRIOR TO SHOP DRAWING SUBMITfALS, ANY ROUGH-INS, AND PLACING FINAL PURCHASE ORDERS. . 2. VERIFY FINAL LUMINAIRE LOCATIONS WITH OTHER CEILING MOUNTE� EQUIPMENT SUCH AS DIFFUSERS, FIRE AIARM �EVICES, SPEAKERS, EfG WITH ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 3. VERIFY EXACT HEIGHT AND LOCATIONS OF ALL WALL MOUNTED AND PENDANT/CABLE MOUNTED LUMINAIRES WITH ARCHRECTURAL ELEVATIONS PRIOR TO ANY ROUGH-IN. 4. LUMINAIRES SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING SUPPORTS UNLESS A�DITIONAL CEILING FRAMING AND SUPPORTS ARE ADDED BY THE CEILING CONTRACTOR ACCOR�ING TO MANUFACTURER'S RECOMMEN�ATIONS LLL. LISTINGS, AND ANY APPLICABLE STATE OR LOCAL CODES. 5. CONNECTIONS TO RECESSED LUMINAIRES SHALL BE MADE WITH MINIMUM 1/2° FLEXIBLE MEfAL CONDUIT (FMC) FROM FI%TURE TO OUTLEf BO%. LENGTH OF FMC SHALL NOT EkCEED 6'. 6. AT THE CONCLUSION OF THE WORK, EACH LUMINAIRE MUST BE CLEANED PER MANUFACTURER'S INSTRUCTIONS, EQUIPPED WITH THE PROPER ttPE, NUMBER OF LAMPS, INCLUDING KELVIN TEMPERATURE AND WATfAGE, AND ALL IN GOOD OPERATING CON�ITION. 7. ELECTRICAL CONTRACTOR TO CONFIRM SIZE TO PROVIDE FULL LENGTH OF UNDER CABINEf. FIRST FI%TURE SHALL BE ttPE 'F6' REST SHALL BE ttPE 'F6A', 'F6B' AND 'F6C LIGHTING SYMBOL LEGEND SYMBOL F2B � a �NL F4A U F6A �� DESCRIPTION RECESSED MOUNTED 2'x2' LUMINNRE. °F2B" INDICATES NPE; "a" INDICAiES SWITCH CONTROL. REFER i0 LUTAINAIRE SCHEDULE FOR ADDIiIONAL MFORMATION. LUMINAIRE WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. "NL"- DENOTES LUAIINAIRE TO BE WIRED AS A NIGHT LIGHT. RECESSED WALL WASH WIAINAIRE. "F4A" INDICATES WMINNRE 1VPE. REFER ID WMINAIRE SCHEDULE FOR A��ITIONAL MFORMATION. UN�ERCABINEf WMINAIRE. "F6A" IN�ICATES WMINAIRE iYPE. REFER ID WMINAIRE SCHEDULE FOR ADOITIONAL INFORMATION. CIRCUITING AND RACEWAY LEGEND SYMBOL DESCRIPTION _ HP2�� HOME RUN TO PANEL "HP2", CIRCUIT �7 VIA A 20A/1P CIRCUIT BREAKER WITH 2�12AWG, �12(G), 3/4"CONDUIT UNLESS NOTED OTHERWISE. �3�8AWG, j�10(G), ��� HOME RUN TO PANEL "LPi", CIRCUITS w'S 8,10,12 VIA A 40A/3P CIRCUIT BREAKER LP7�8,10,12 CONDUCTOR SIZE/QUANiItt AS INDICAiED. 40/3 POWER DISTRIBUTION EQUIPMENT SYMBOL LEGEND SYMBOL DESCRIPTION � 480Y/277 WLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOAR� � 2�BY/120 VOLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOARD FIRE ALARM SYMBOL LEGEND � VISUAL (SiROBE) ONLY SIGNALING DEVICE DEMOLITION ANNOTATION LEGEND "g° DENOTES ExISTMG DEVICE/EQUIPMENT TO BE REIAWED IN ITS ENTIREIY INCLUDMG JUNCTION BOXES, CONDUITS AND CIRWITRY, ETC. COMPLETE, BACK TO SOURCE OR NERT ACTNE DEVICE BEMG MAINTAMED ON CIRCUIT. "XR" DENOTES EXISTING DEVICE/EOUIPAIENT TO BE RELOCATED IN IT$ ENTIREIY. MAINTAIN ALL BRANCH CIRWIT WIRING, CONDUIT, EiC. FOR RELOCATION TO NEW LOCATION ('%N") AS INOICAiED ON "NEW WORK' DRAWINGS. °%N" DENOTES NEW LOCATION OF EXISTMG RELOCATED ("NR') DEVICE/EQUIPMENT. REWORK ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. i0 NEW LOCAiION A$ REQUIRED. "%M" DENOTES EXISiING DEVICE/E�UIPA�ENT TO BE MAINTAMED. TYPICAL DEVICE MOUNTING FIRE AIARA� AUDIBLE/VISUAL AND VISUAL ONLY SIGNALING DEVICES RECEPTACLES BEHIND 0 REFRIGERAi0R5 AND VENDING MACHMES WALL TELEPHONES FlRE AlAR1A MANUAL PULL STATION LIGHTING CONTROLS CONFIRM MOUNTING HEIGHT � ( � � WIiH LOCAL CODE RE�UIREMEMSJ � VOLUME CONTROLS DEVICES ABOVE COUNTERiOP � AND/OR BACKSPLASH � ? � � � RECEWACLES IN MECH/ELEC � � � � � IAVATORIESO ADJACENT TO � � � � �� RECEPTACLES BEHIND � � �OIAESTIC WASHERS AND DRYERS �GENERAL PURPOSE � � RECEPTACLES M � � �'� R�ECE TACLES SERVING � DISHWASHER AND _ GARBAGE �ISPOSAL NOTES: 1. ALL MOUNTING HEIGHiS SHALL BE MEASURED FR01A FlNISHED FLOOR TO THE CEMERLWE OF DEVICE E%CEPT FIRE AURM STROBE LIGHi. 2. NO WIRING DEVICE OUTLEf BO%ES SHALL BE MOUNTED BACK TO BACK. 3. ALL MOUNTING DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AS INDICATE� ON THIS DEiAIL UNLE55 OTHERWISE NOTED. 4. FOR ALL ELEVATIONS (WHERE APPLICABLE), CASEWORK �EfAILS, FIRE WALLS, SMOKE WALLS, LOCATION OF COUNTERTOP RECEPTACLES, LIGHTING FIXTURE SWITCHES, TELEPHONE OUTLEfS, EQUIPMENT ROUGH-INS, HEA�WALLS, EfC., SEE ARCHITECTURAL �RAWINGS. WHERE NO ARCHITECTURAL ELEVATIONS OR DEfAILS OCCUR, THE ELECTRICAL CONTRACTOR SHALL USE PRACTICAL MFANS AN� MEfHODS AS WELL AS HIS FIEL� KNOWLEOGE ID LOCATE �EVICES IN THE BEST SUITE� AND MOST PRACTICAL LOCATIONS FOR THE �EVICE. �Inregrared 1�En�'meerinp Consvdtants,l�c. 9700 ROCNSIDE RD. SUITE 290 CLEVELAND.OX 44125 PHONE:716901�6711 FA%:216-901-6712 GENERAL ELECTRICAL NOTES 1. ALL 'BUIL�ING STAN�AR�S" ANO/OR "BUILDING SPECIFICATIONS" SHALL BE CONSI�ERED AN INiEGRAL PART OF THESE OOCUMENTS AN� THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS AN� COMPLY WITH ALL REQUIREMENTS, STAN�AROS, AND SPEQFICATIONS CONTAINED WITHIN. 2 THESE DRAWINGS ARE GENERALLY �IAGRAMMATIC AND ARE IMENDE� TO CONVEY THE SCOPE OF WORK AN� INDICATE GENERAL ARRANGEMENT OF LIGHTING FIX�URES, DEVICES, CONTROLS, ELECTRICAL FIXTURES, MOTORS, PANELBOARDS, EOUIPMEM, EfC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE �RAWINGS OR CALLEO FOR IN THE SPECIFICATIONS THAT ARE NOT OEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CON�ITIONS AND RESULTS MOST BE �EfERMINE� AT THE PROJECT. ALL LOCATIONS OF WORK EXPOSEO TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHRECT PRIOR TO ROUGH-WS. 3. THE ELECTRICAL WNTRACTOR SHALL VERIFY EXISTING CON�ITIONS TO WSIIRE iHAT ALL NEW WORK WILL FIT IMO THE EXISTING STRUCTURE AN� CON�ITIONS IN THE MANNER INTEN�E� AN� AS SHOWN ON THE �RAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHRECT/OWNER$ REPRESENiATNE PRIOR TO ANY ROUGH-INS. FABRICATIONS, OR PERFORIAMG ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFlCATION SHALL BE IN THE FORM OF A RFl, INCLUDMG A DRAWING OR SKEiCH INDICATING FlELD IAEASUREMENTS AND NOTES RELATED TO THE AREA. 4. ANY DISCREPANCIES BEiWEEN DRAWINGS AND SPECIFlCATION$ SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGMEER FOR CIARIFlCATION �URING THE BIODING PERIOD. NO ALLOWANCE SHALL SUBSEOUEMLY BE MADE TO THE CONTRACTOR 8Y REASON OF MS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATfENT10N OF iHE ENGMEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 5. ALL EOUIPMENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKMANLME MANNER, RECTILWEAR TO RNISHES AND BUILDING SiRUCTURE. 6. ALL COMPONENTS SHOWN ON THE RISER�ONE-LINE DIAGRAMS, BUT NOT ON THE PIAN OR VICE VERSA, SHALL BE INCWDE� AS IF SHOWN ON BOTH. 7. REFER TO ARCHITECTURAL ELEVAiIONS TO �ERNE EXACT LOCATIONS OF ALL RECEPTACLES, OUTLEfS/JACKS, SWITCHES, WALL AND PENDANT/CABLE MOUNTED LUMINAIRES, ETG LUMINAIRES AND CEILING MOUNTED EOUIPIAENT SHALL BE COORDINATED WITH THE ARCHRECTURAL RCP (REFLECTED CEILING PLANS). 8. ALL CIRCUITING SHALL BE RUN CONCEALE� UNLE55 SPEGFlED OTHERWISE. 9. ALL RACEYVAYS RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE EXPANSION FITfINGS. 1�. CON�UIT HOME RUNS SHOWN ON THE DRAWING WITH MORE THAN (3) CURRENT CARRYING WNDUCTORS ARE SHOWN �WGRAA�ATICALLY. THIS CONTRACTOR SHALL NOT INSTALL MORE THAN (3) CURRENT CARRYING CONDUCTORS IN A RACEwAY UNLESS NATIONAL ELECiRIC CODE (REC), ARTICLE 310.15 DERAiING FACTORS ARE APPLIED. n. ALL LIGHTING AND GENERAL POWER BRANCH CIRCUITS SHALL INCLU�E A SEPARATE NEUTRAL CONDUCTOR, UNLESS SPEqFICALLY INDICATED OTHERWISE. 12. THE ELECTRICAL CONTRACTOR SHALL REFER i0 THE ELECTRICAL SPEQFICAilONS FOR ACCEPTABLE CONDUIT IYPES/LOCATIONS. ALL CONDUIT SIZES ON THE �RAWINGS ARE BASED ON THE CURRENT AOOPTE� EDITION OF THE N.EG WNDUIT FlLL TABLES FOR ELECiRICAL MEfALLIC TUBING (E.M.T). WN�UIT SRES SHALL BE REVISE� TO THE SIZE REQOIRE�, REIATNE TO THE ACTUAL CONDUIT NPE TO BE WSTALLE�. 13. IT IS NOT IMEN�ED THAT THE PVilJS INOICATE ALL OBSTRUCTIONS, NECESSARY BENDS, OFFSEfS, AN� POLL BOXES. IT SHALL BE iHE RESPONSIBILIIV OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO N.EC. REQUIREA�ENTS THE STRUCTURE MAINTAIN HEADROOM AN� KEEP OPENINGS AN� PASSAGEWAYS CLEAR. REFER TO THE ARCHITECTURAL �RAWINGS FOR ALL �IMENSIONS AS REOl11RE�. 14. IT IS NOT WTEN�E� THAT THE PLANS INOICATE ALL WN�l11T ROUTES, PULL BORES, JUNCTION BOXES, EfC. CONTRACTOR SHALL BE RESPONSIBLE FOR �EfERMINING ACTUAL CONOUIT ROUTING QUANTItt AN� LOCATION OF POLL BOXES WITHIN ACCESSIBLE LOCATIONS. 15. PROVI�E SCREW-COVER PULL BOXES IN CON�UR RUNS AS REOUIRED TO LIMIT THE NUMBER OF BENDS TO NO MORE iHAN FOUR (4) 90' OR 360 DEGREES iOTAL. SIZE PULL BORES IN ACCORDANCE WITH NEC, ARTI0.E 31428. DOWMENT ON RECORD DRAWINGS, SIZE AND LOCATION OF PULL BOXES USED W FEEDER CON�UIT RUNS. 16. WHERE MULTIPLE DEVICES OF THE SAME ttPE/SttLE ARE SHOWN NE%T TO EACH OTHER, GANG TOGEfHER IN A SINGLE COVER PIATE. 17. ALL FWSH MOUMED PANELBOARDS SHALL HAVE THREE (3), 3/4" CONDUITS STUBBE� ABOVE ACCESSABLE CEILINGS FOR FUTURE CIRCUITS. 1fl FIEL� VERIFY THE EXACT LOCAiION OF MECHANICAL HVAC AND PWMBING EQUIPMENT THAT REQUIRE ELECTRICAL CONNECTIONS WITH RESPECTIVE CONTRACTORS. 19. ALL CIRCUITS INDICATED ORIGINAiING M EXISTING PANELBOARDS ARE BASE� ON INFORMATION OBTAIN PRIOR TO ANY DEIAOLITION WORK. IF A CIRCUIT NUMBER(S) INDICATED TO BE RE-USED REMAWS "IN-USP' AFfER ALL DEMOLITION WORK IS C0IAPLETED, iERMINATE HOMERUN ON A SPARE(5) qRCUIT BREAKER IN SAME PANEL OR PROVIDE A NEW CIRCUIT BREAKER(S) TO MATCH E%ISTING IYPE AN� HOMERUN TO AVAILABLE SPACE(S) IN SAME PANEL 20. ALL CONDUR SIZES IN�ICAiE� ARE BASE� ON ELECTRIC MEfALLIC TUBING (EMT). THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY SIZING ALL OTHER WNDOITS NPES USED PER NEC RWUIREMENTS. NELSOI� Nelm Architedure, Inc. a licensed affliate 30 West Monroe Street - Suite 200 Chicago, IL 6060&2409 Phone: (312)263-6605 (312) 2I8-0340 OWNER'S PROJECT MANAGER ]ones Lang LaSalle Leslie Soto 540 W. Madison St, Sui[ eIL9-540-09-55 Chicago, IL 60661 T:312.909.2139 E:lesliesoto@am.jlLmm MEPENGINEER Integrated Engineering ConsWtants,Inc (IEC) Tim Vlning 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T. 216.901.67ll E: tim.vining@ieC-inCcc GENERALCONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.589.2770 E: tic@midamericacontracting.com ARCHITECT OF RECORD Nelm Architecture, Inc. Vincent Paul Duet IN. LIC NO: AR11500046 Exp:12/31/2021 T. 215.825.6620 E: vduet@nelsonww.com ConsWtant'. MERRILL� A BANK OF AM ERICA COMPANY Cllent. INW-044 BofA Indianapolis MLWM Pantry Refresh, Sth Floor 510 96th Street Indianapolis, IN 46240 Project TiHe & Nddress: ELECTRICAL SCHEDULES, LEGENDS AND NOTES SheetTiHe�. = PE118005]5 i�l • - STAiE OF ; Q- =Po''.�NoIAN?.' 2�N �'. FSSroNA�e��� ��.c �-•�/���,,,�%/'� RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 03�27�20 Seal: Pmj. No'. 19.00052]J.000 Dcsigncr. ERO;MBM �rawn By: T6V Reviewed By: HHH Pmjcct Managcr. M]L qppmved By: HHH EO-1 ALL �IMENSIONS AN� LONDITIONS MOA BE CHECKED AND VERIRED ON SITE BY THE CONTPPQON PND SU6-CONTRAQORS PRIOF TO PCFFORMING TIIC W02K. TI IC FROJCQ MBNAGCR SI IALL 8C NOTIFlC� IN WRITING �F ANY �ISCREPANCIES PRIOR TO PROCEE�ING WITH THE W�RK. m me�sory won�owroe, uczozo nu aisnTs aeseaveo