Loading...
HomeMy WebLinkAboutM0.1 Mech HVAC DetailsREGISTER, GRILLE & DIFFUSER SCHEDULE (GRD)��FMK A1ARK SERVICE MANUFACTURER MODEL NECK SRE FRAME SIZE MAN NC FlNISH BORDER REMARKS A SUPPLY PRICE SPD 8"0 24"x24" 25 BY ARCH IAYIN 1 R�R� 1. iHE MECHANICAL HVAC CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO COORDINAiE AND VERIFY ALL CEILING iYPES WITH ARCHRECT AND ARCHITECTURAL CEILING PIANS, DEfAILS, SCHEDULES, ETC., INCLUDING, BUT NOT LIMITED TO DIFFUSER/GRILLE COLORS, LENGTHS, TRIMS, FINISHES, FRAMES, MOUNTING WNFIGURATIONS AND HARDWARE, ETC. PRIOR TO ANY ROUGH-INS AND PIACING FINAL PURCHASE ORDERS. 2. SEE FLOOR PLANS FOR CFM. 3. CONNECTING DUC7WORK SHALL BE SIZED TO MATCH NECK, UNLESS SHOWN OTHERWISE. MECHANICAL HVAC NOTES 1. �RAWINGS INDICATE THE MINIMUM �ESIGN REOUIREMENTS. FE�ERAL, STATE, AND LOCAL CODES SHALL BE FOLLOWED, COMPLY WITH THE IATEST E�ITIONS OF THE STATE MECHANICAL CODE, NFPA, SMACNA, AN� ASHRAE STAN�AR�S. THE WNTRACTOR SHALL INCWDE THE WST OF SATISFYING SUCH CODES AN� STAN�AR�S IN THE BI�. 2 GENERAL NOTES, SYMBOLS LIST AN� �EfAILS ARE APPLICABLE TO ALL �RAWINGS WITHIN COMACT DOCUMENTS. 3. COOR�INATE WORK OF THIS SECTION WRH THAT OF OiHER SECTIONS. 4. SHEEf MEfAL FITfINGS SHOWN ARE TO BE PROVIDE�. NO SUBSTITUTES SHALL BE ALLOWED WITHOUT PRIOR CONSENT FROIA ARCHITECT/ENGMEER. 5. RUN DUCTS AND PIPING CONCEALED, UNLE55 SPECIFlED OTHERWISE, AND 0.EAR OF CEILING INSERTS. ALL DUCiWORK SHALL BE INSTALLED AS CLOSE AS P059BLE TO WALL AND UNDERSIDE OF BEAMS AND JOISTS. 6. ALL WORK SHALL BE COORDINATED WITH ALL iRADES INVOLVED. OFFSEiS IN PIPING AND DUCTS (INCLUDING DIVIDED DUCTS) AND TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. ARRANGE OPERATIONS 50 AS NOT TO DEUY COMPLETION OF INSTALLATION OF ANY PARTS OF INTERREIATED WORK 50 THAT CONSTRUCTION MAY PROCEED ON SCHEDULE. 7. DIFFUSER SIZES SHOWN ARE NECK SRES; REGISTER AND GRILLE SRE ARE NOMINAL. SUPPLY DUCT TO �IFFUSERS/GRILLES SHALL EOUAL NECK SRE UNLESS SHOWN OTHERWISE 8. INSUTATE ALL SUPPLY AIR �UCIWORK IN WNCFALED ANO REfURN AIR PLENUMS WITH MINIMUM R-3.5 ALL SERVICE FIBER GLASS DUCT WRAP WITH FRN VAPOR REfAR01NG FACING. DUCT WRAP IN REfURN AIR PLENUM SHALL COMPLY WITH ASTM E 84 (FUME SPREAD - 25, SMOKE DEVELOPED - 50). 9. HVAC CONTRACTOR SHALL FlELD VERIFY ALL E%ISTING REMS SRES, AND MATERIALS BEFORE FABRICATION OR PURCHASE OF ALL NEW ITEMS. 10. REPAIR FlREPROOFlNG ARER INSTALLATION OF HANGERS AND SUPPORTS. 11. ALL MATERWLS M CEILING SPACE SHALL BE PLENUM RATED PER OMC. 12. ALL ITEMS OF IABOR, MATERIAL, AND EOUIPMENT NOT SPECIFlCALLY MENTIONED HERBN OR SHOWN ON PIAN, BUT MCIDENiAL T0, OR REQUIRED FOR THE COMPLETE INSiALLAT10N AND PROPER OPERATION OF iHE WORK, SHALL BE FURNISHED AS IF CALLED FOR IN DETAIL BY THE DRAWINGS. 13. THE HVAC CONTRACTOR SHALL SECURE AND PAY FOR ALL PERIAITS AND INSPECTION$ REOUIRED FOR iHE PROSECUTION OF HVAC WORK. ALL PERMIT$ AND CERiIFlCATES OF INSPECTION AND APPROVAL SIGNED BY THE CONTROLLING BUILDING DEPARTMENT SHALL BECOME PROPERiY OF THE OWNER. 14. UNLE55 NOTED OiHERWISE, ALL HOLES OR DAMAGE CAUSED BY THE REMOVAL OF E%ISTING WORK OR THE INSTALUTION OF NEW WORK SHALL BE PROPERLY PATCHED BY THIS CONiRACTOR. HOLES SHALL BE NEATLY PAiCHED AND PAIMED WITH SUITABLE MATERIAL i0 MATCH E%141NG SURFACES. HOLES THROUGH FLOORS OR FIRE WALLS SHALL BE SEALED WITH THE APPROPRIAiE INTUMESCENi CAULK, PUTiY, SiRIP OR SHEEi FIRE BARPoER PRODUCT. 15. ALL E%ISTING NR DISTRIBUTION DEVICES THAT ARE TO BE REUSED SHALL BE CLEANED WITH MILD SOAP AND WATER SOLUTION AND THOROUGHLY DRIED. 16. ALL E%ISTMG TO REMAIN HVAC SYSTEAIS SHALL BE CLEANED PER CURRENi NATIONAL AIR DUCT CLFANING ASSOCIATION GENERAL SPEQFICATIONS. 17. HVAC DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT, APPRO%IMATE SRES, GENERAL LOCATIONS OF EQUIPMENT AND PIPING. VERIFY DIMENSIONS W FlELD; ADJUST TO MANUFACTURER$ SHOP �RAWINGS. DO NOT SCALE �RAWINGS. 18. ALL DUC7WORK JOIMS AND SEAMS SHALL BE AIR-TIGHT PER SMACNA. POORLY MADE JOINTS, SPLITS, VISIBLE HOLES AT CORNERS, EfC SHALL BE REWORKE� AND REPAIRED. WHERE E%CESSIVE PULSATING OF �UCiWORK IS FOUND, ADDITIONAL STIFFENERS SHALL BE ADDE�. ANY CRACKING IN THE SEALANT THAT IS APPARENT UPON INSPECTION SHALL BE SUFFIGENT TO WARRANT REJECTION, 19. LOW PRESSURE DUC7WORK SHALL BE CONSTRUCTED PER SMACNA `HVAC DUCT CONSTRUCTION STANDARDS"FOR 2 INCH STATIC PRESSURE, SEAL CLASS "B". 20. HANGERS AND SUPPORTS PROVIDE GALVANIZED STEEL ARAPS, ALL-THREAD ROD AND HORIZONTAL ANGLE SUPPORTS SIZED PER SMACNA REQUIREMENTS. 2L INSTALL FLEkIBLE DUC7WORK FULLY EXTENDE�, FREE OF SAGS AND KWKS. MA%IMUM LENGTH OF FLEXIBLE DUCiWORK SHALL BE 3'-�". FASTEN FLEXIBLE DUCiWORK TO RIGI� �UC7WORN AN� �EVICES WITH SELFLOCKING 100 PERCENT NYLON, MJUSTABLE �IAMEfER CIAMPS. 22. PROVIDE BAIANCMG DAMPERS FOR ALL AIR TERMINAL DEVICES (SUCH AS BUT NOT LIMIiED T0, DIFFUSERS, REGISiERS, GRILLES, EfC.) AND BRANCH DUCiWORK RE�UIRED FOR PROPER BALANCING OF SYSTEM. ALL BALANCING DAMPERS SHALL BE CONSTRUCTE� IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION SiANDAR�S". FASTEN TO STRUCTURE GALVANRED SHEEf METAL DUCT TO SUPPLY AIR MNN 1" WI�E MINIMUM MEfAL STRAP HANGER. 1" THICK FlBERGlASS INSUlATION w/Fai� Fncwc pF REquiREo, sEE SPECIFICATIONS) VOLUME DAMPER NSUTATE� FLEXIBLE CONNECTION. (unxiuu� a rE�r) m vERncn� ONLY. MEfAL STRAP QAMPS (ttPICAL) 2 PwcEs iNNCR oucr x ou�cR VAPOR BARRIER. THERMAL INSOL1iING BLANKEf. ECTING DUCT SIZE SHALL BE SAME OS SER NECK UNLESS SHOWN OTHERWISE. NELSOI� Nelm Architedure, Inc. a licensed affliate 30 West Monroe Street - Suite 200 Chicago, IL 6060&2409 Phone: (312�263-6605 (312) 216L340 OWNER'S PROJECT MANAGER ]ones Lang LaSalle Leslie Soto 590 W. Madison St, Suit eIL4-590-04-55 Chicago, IL 60661 T:31L90A2139 E:lesliesoto@am.jll.com MEPENGINEER [ntegrated Engineering Consultants, Inc (IEC) Tlm Vining 9700 Rockside Road, Suite 290 Cleveland, OH 44125 T: 216.901.67ll E: tim.vining@iec-inc.cc GENERALCONTRACTOR Mid America Contracting, Inc. Tyler Crawford 107 N. Main Street, Suite 3A Columbia, IL 62236 T: 618.589.2770 E: tic@midamericacontracting.com ARCHITECT OF RECORD Nelm Architecture, Inc. Vincent Paul Duet M. LIC NO: AR11500046 Exp: 12/31/2021 T: 215.825.6620 E: vduetC�nelsonww.mm ConsWtant MERRILL� A BANK OF AMERICA COMPANY Client INW-044 BofA Indianapolis MLWM Pantry Refresh, Sth Floor 510 96th Street Indianapolis, IN 46240 PmjeQ TiHe & Fddress: MECHANICAL HVAC SCHEDULES, LEGENDS AND NOTES SheetTiHe: = PE118005]5 [�l • ' STATEOF �%g `-Po'..!NoinN?.� �`�i� '. F NG` � " SsioNn�E r ��c� j,�����,,��� THICKNESS & REINFORCING SCHEDULE -* LOW PRESSURE DUCTWORK cR�arEsr oucT srEc� oucTs us. �IMENSION STAN�ARD GAUGE 17' OR LESS 26 13" THRU 18" 24 19" THRu 30" 24 31' THRU 4Y ZZ 43' THRU 54' �� duM oucrs e & �oNciTuoiNn� S GAUGE SEAM 24(OD20') PITf58URGH OR ACME LOCK 22(0.025') PITfSBURGH OR ACME LOCK 22(0.025') PfRSBURGH OR ACME LOCK 20(0.032') PfRSBURGH OR ACME LOCK ANGLES TO BE THE SAME SRE AS REQl11RE� REINFORCING ANGLES ANGLE SLIP ANGLES TO BE THE SAME SRE AS REQUIRED REMFORCMG ANGLES CAULK OR GASKET COMPANION ANGLES ANGLES TO BE THE SAME SRE AS REQUIRED REMFORCMG ANGLES ANGLE REINFORCED POCKEf LOCK ��� ACME LOCK HEMME� '�' SLIP �� STAN�ING SEAM 7RANSVERSE JOINT 7RANSVERSE JOINT SMALLEST �IMENSION GRFATEST DIMENSION DRIVE SLIP OR POCKEf PUIN "S" SLIP OR POCNEf LOCK OR BAR SLIP LOCK OR BAR SLIP DRNE SLIP OR POCKET p�qlN "S" SLIP OR POCKET LOCK OR BAR SLIP LOCK OR BAR SLIP HEMMED "5" SLIP OR BAR HEMMED "5" SLIP OR BAR SLIP OR DRNE SLIP OR 1" SLIP OR 1" POCKEf LOCK POCKEf LOCK DRNE SLIP 18" OR LE55 �E SLIP OR REIN- FORCEI BAR SLIP REIN- FORCED BAR SIJP OR POCKEf LOCN 3AR $LIP OR POCKET LOCK 1 1/4" BAR SLIP, OR RE- 1 1/4' BAR SLIP, OR RE- MFORCED BAR SLIP, OR 1 MFORCED BAR SLIP, OR 1 1/2" POCKEf LOCK 1/2" POCKEf LOCK � G DRNE SLIP � REINFORCED BAR SLIP � ALTERNATE BAR SLIP NOTE: L LOW PRESSURE DOCiWORK SHALL BE �UCiWORK IN WHICH THE PRESSURE DOES NOT EXCEE� 2" WATER GAUGE. REMFORCING (ALL DUCTS 18' THRU 54' SHALL BE CROSSBROKEN) NONE REQUIRED IF iRANSVERSE JOINTS ARE LOCAiED 4'-0" OR LESS ON CEMER NO REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"R1°%1/8" IF TRANSVERSE JOINTS ARE LOCAiED 4'-0" OR LESS ON CEMER NO REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"R1°%1/8" IF iRANSVERSE JOINTS ARE LOCAiED 4'-0" OR LESS ON CEMER NO REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"X1°X1/8" � POCKEi LOCN � PITTSBURGH LOCK � AB R SLIP PIAIN '�LIP ANGLES TO BE THE SAME SRE AS REQUIRED REINFORCING ANGLES ANGLE REWFORCE� DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES RECTANGUL4R DUCTS MA%IMUM SRE 4EEL ALUAIINUM QNCHES) (MINIMUM THICKNESS, NOMINALJ (MINIMUM THICKNESS, NOMINAL) THROUGH 12 0.022 INCH (26 GAGE, GALV.) 0.020 INCH (N0. 24 B&S GAGE) 13 THROUGH 3� OD28 INCH (24 GAGE, GAW.) a.ozs iNCH (No. zz e&s cncE) 31 THROUGH 54 0.034 INCH (22 GAGE, GALV.) 0.032 INCH (N0. 20 B&S GAGE) 55 THROUGH 84 0.040 MCH (20 GAGE, GALVJ 0.040 MCH (N0. 18 B&S CAGE) ovEe aa o.osz iNcn (ia cncE, cn�v.) o.osi mcn (No. is e&s cnce) ROUND DUCTS SPIRAL SEAM DUCT LONGIiUDINAL SEAM DUCT FITTINGS MA%IMUM SIZE STEEL STEEL STEEL QNCHESJ (IAINIMUM THICKNESS, NOMINAL) (MINIIAUTA THICNNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) iHROUGH 12 0.019 INCH (28 GAGE, GALV.) OD22 INCH (26 GAGE, GALV.) �A22 INCH (26 GAGE, GALV.) 13 THROUGH 18 0.022 INCH (2fi GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) 19 THROUGH 28 0.028 INCH (24 GAGE, GALV.) 0.�34 INCH (22 GAGE, GALV.) �.034 INCH (22 GAGE, GALV.) 29 THROUGH 36 0.034 MCH (22 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 3� rHeoucH ss o.oao iNCH (za cace, cn�v.) o.osz mcH (ia cncE, cn�v.) o.osz mcH (ia cncE, cuv.) RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 03�27�20 MECHANICAL HVAC SYMBOL LEGEND � � � � � -x-x- x � xx CFMK %M �Inre��arcd 1�Engineenn� Consvltan2s,lnc. 9700 ROCNSIDE RD. SUITE 790 CLEVELAND,OX 44125 PHONE:1169014711 FAX:216901�6712 SUPPLY OR OUT�OOR AIR �UCT UP SUPPLY OR OUTDOOR AIR DOWN REfURN, OR RELIEF AIR DUCT UP REfURN, OR RELIEF AIR DUCT DOWN BAUNCING (VOWME) �AMPER EXISTING ITEM TO BE REMOVED NEW DUC7WORK EXISTING �UCiWORK/EQUIPMENT TO REMAIN 7HERMOSTAT DIFFOSER OR GRILLE DESIGNATION NOTE: ALL REIAS LISTED IN THI$ LEGEND MAY OR MAY NOT BE ON TMS PROJECT. Seal: Pmj. No: 19A�OSD].�00 Designco ERO;MBM �rawn By: ]PH Revicwctl By. HHH Pmjcct Managcr. MJL qppmved By: HHH MO-1 ALL�IMENSIONSAN� LON�ITIONS M114 BE p1ELKED AND VEFIFIE� ON SRE 6Y THE CONTRPQOF AND SUB-CONTRAQOPS PNIOR TO FCRFORMING TI IC WOPK. TI IC PROJCR MANAGCR SI IALL 9C NOTIFlC� IN W WTIN6 OF ANY �ISCREPANC[ES PFIOR TO PROCcE�ING WRH THE WORK. ;� rvEisory waR�ow�oE, uc zozo Au nrcrvTs nESEavEo CEILING DIFFUSER DETAIL SCALE:NONE