HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION
Customer Name
{\C256;* Market Home *, 6838-02700#2}
Address{\C256;13021 COPPER RUN BOULEVARD}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074}
Community{\Fsimplex|c0;\C256;6838}{\C256;COPPER RUN}{\C256;6838-02700}{\C256;LOTNUM 123}
Plan Features{\C256;Elevation HR2H}
MUNICIPALITY
STRUCTURAL ENGINEER APPLICABLE CODES
MECHANICAL ENGINEER
BUILDING CODE ANALYSIS
DESIGN LOADS and CRITERIA
AREA CALCULATION (SQ. FT.)
\pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; }
ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxtr28;SEE STRUCTURAL PLANS FOR DESIGN CRITERIA
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}
SHEET LIST TABLE
SHT DESCRIPTION
CC.01 Cover Sheet
CC.02 Notes - Schedules and Legends
A0.01 Foundation - Basement
A1.01 Finished Basement Floor Plan
A1.11 1st Floor Plan
A1.21 2nd Floor Plan
A2.02 Building Section
A2.03 Building Section
A3.01 Front Elevation
A3.02 Left Elevation
A3.03 Right Elevation
A3.04 Rear Elevation
A4.01 Roof Plan
U0.01 Basement Utility Plan
U1.01 Finished Basement Utility Plan
U1.11 1st Floor Utility Plan
U1.21 2nd Floor Utility Plan
Structural Plan - Foundation Basement (IN Code)
Structural Plan - 1st Floor (IN Code)
Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt. Additional Cabinets at Pulte Planning CenterBath 7 OptionOpt Boot Bench at Owner's EntryBuilt in Kitchen OptionOpt. Butler PantryOpt Coach Light - Location 1Opt Coach Light - Location 3Opt Double Sink Bowl at Bath 2Opt Deck at RearElevation HR2HNo OptionFinished Basement OptionStandard Flex RoomBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageGathering Room - Additional WindowMasonry Wrap - Sides and RearOwner's Bath 5IndianaOpt. Tray Ceiling at Dining RoomOpt Tray Ceiling at Owners SuiteOpt. Wainscot - Front ElevationOpt Basement Window Well - Location 1
SQUARE FOOTAGE
TOTAL:CONDITIONED - LIVABLE SF
1st Floor
2nd Floor
Basement - Finished
1672 SF
1694 SF
911 SF
4276 SF
TOTAL:CONDITIONED - NON-LIVABLE SF
Basement - Storage & Mech
Basement - Unfinished
626 SF
1602 SF
2228 SF
TOTAL:UNCONDITIONED SF
3 Car Garage Side
Front Porch
674 SF
115 SF
789 SF
7294 SF
COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc.
PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019
PROJECT TYPE
Single Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Castleton
2022.300Home for * Market Home *, 6838-02700#213021 Copper Run Boulevard, Carmel, IN 46074CC.01
03/26/20
William Hohlt