Loading...
HomeMy WebLinkAboutGN000.1LOT SPECIFIED PLAN INFORMATION Customer Name {\C256;* Market Home *, 6838-02700#2} Address{\C256;13021 COPPER RUN BOULEVARD}{\Fsimplex|c0;\C256;CARMEL}{\C256;IN}{\C256;46074} Community{\Fsimplex|c0;\C256;6838}{\C256;COPPER RUN}{\C256;6838-02700}{\C256;LOTNUM 123} Plan Features{\C256;Elevation HR2H} MUNICIPALITY STRUCTURAL ENGINEER APPLICABLE CODES MECHANICAL ENGINEER BUILDING CODE ANALYSIS DESIGN LOADS and CRITERIA AREA CALCULATION (SQ. FT.) \pxt12;{\H0.92593x;BUILDING CODE:\PPLUMBING CODE: \P\pql;MECHANICAL CODE:\PFUEL AND GAS CODE:\P\pq*;ENERGY CODE:\PELECTRICAL CODE:\P\pql;FIRE CODE:\P\pt14;\P\pq*,tz;}1. PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY THE REQUIRED DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. VERIFY WITH THE LOCAL BUILDING AGENCIES THE WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. THE ARCHITECT SHALL BE NOTIFIED IN WRITING OF ALL DISCREPANCIES.\P\pa0.25;2. THERE SHALL BE NO STRUCTURAL CHANGES WITHOUT WRITTEN CONSENT OF THE ENGINEER OF RECORD.{\H0.92593x; } ZONING ORDINANCE: .\PUSE GROUP: .\PCONSTRUCTION CLASS: .\PHEIGHT & AREA: .\POTHER REQUIREMENTS: .\pxtr28;SEE STRUCTURAL PLANS FOR DESIGN CRITERIA \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} \pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.}\pxql;{\H1.3334x;.\P\H0.69446x;.\P.\P.\P.} SHEET LIST TABLE SHT DESCRIPTION CC.01 Cover Sheet CC.02 Notes - Schedules and Legends A0.01 Foundation - Basement A1.01 Finished Basement Floor Plan A1.11 1st Floor Plan A1.21 2nd Floor Plan A2.02 Building Section A2.03 Building Section A3.01 Front Elevation A3.02 Left Elevation A3.03 Right Elevation A3.04 Rear Elevation A4.01 Roof Plan U0.01 Basement Utility Plan U1.01 Finished Basement Utility Plan U1.11 1st Floor Utility Plan U1.21 2nd Floor Utility Plan Structural Plan - Foundation Basement (IN Code) Structural Plan - 1st Floor (IN Code) Structural Plan - 2nd Floor (IN Code)LOT SPECIFIC OPTION SELECTIONSOpt. Additional Cabinets at Pulte Planning CenterBath 7 OptionOpt Boot Bench at Owner's EntryBuilt in Kitchen OptionOpt. Butler PantryOpt Coach Light - Location 1Opt Coach Light - Location 3Opt Double Sink Bowl at Bath 2Opt Deck at RearElevation HR2HNo OptionFinished Basement OptionStandard Flex RoomBasement FoundationTraditional Fireplace at Gathering Room3 Car Side Load GarageGathering Room - Additional WindowMasonry Wrap - Sides and RearOwner's Bath 5IndianaOpt. Tray Ceiling at Dining RoomOpt Tray Ceiling at Owners SuiteOpt. Wainscot - Front ElevationOpt Basement Window Well - Location 1 SQUARE FOOTAGE TOTAL:CONDITIONED - LIVABLE SF 1st Floor 2nd Floor Basement - Finished 1672 SF 1694 SF 911 SF 4276 SF TOTAL:CONDITIONED - NON-LIVABLE SF Basement - Storage & Mech Basement - Unfinished 626 SF 1602 SF 2228 SF TOTAL:UNCONDITIONED SF 3 Car Garage Side Front Porch 674 SF 115 SF 789 SF 7294 SF COVER SHEETMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2019 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:05/10/2019 PROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Castleton 2022.300Home for * Market Home *, 6838-02700#213021 Copper Run Boulevard, Carmel, IN 46074CC.01 03/26/20 William Hohlt