Loading...
HomeMy WebLinkAboutpriscilla-hamill-design_157955-permit-packageDIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXMODULE DATASHEET OPTIMIZER DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS 611 BEAVERBROOK DR, CARMEL, IN 46032 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) UTILITY COMPANY INDIANAPOLIS POWER & LIGHT CO ELECTRICAL CODE 2011 NEC (NFPA 70) FIRE CODE 2012 IFC OTHER BUILDING CODES 2014 IN BUILDING CODE 2020 IN RESIDENTIAL CODE 2012 IN PLUMBING CODE 2014 IN MECHANICAL CODE CONTRACTOR INFORMATION COMPANY RECTIFY LLC DBA RECTIFY SOLAR ADDRESS 3911 N COLLEGE AVE, STE B, INDIANAPOLIS, IN 46205 PHONE NUMBER (317) 643-1002 SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 3,410W AC RATING OF SYSTEM 3,800W AC OUTPUT CURRENT 16.0A INVERTER(S) 1 X SOLAR EDGE SE3800H-US MODULE MISSION SOLAR MSE310SQ8T ARRAY WIRING (1) STRING OF 11 INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD-SIDE AC CONNECTION PER NEC 705.12(D) AT MSP UTILITY SERVICE 120/240V 1Φ ELECTRICAL PANEL MAIN SERVICE PANEL W/200A BUSBAR 200A MCB SITE DETAILS ASHRAE EXTREME LOW -23°C (-9°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE INDIANAPOLIS (KIND) RISK CATEGORY II P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032PROJECT SUMMARY DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-1 03/26/20 Mike Sheeks GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 4 WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS, TYPE MC METAL- CLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS, PER NEC 690.31(E). 5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (E) UTILITY METER, OUTDOOR (N) INVERTER (I1), OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR (N) TRANSITION BOX (JB1), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 11 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 180° AZIMUTH P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032SITE PLAN DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-2 03/26/20 Mike Sheeks PV MODULE OPTIMIZER 11 IN STRING PM1-11 310W 1 1 2 3 4 JUNCTION BOX 2 JB1 INVERTER I1 3,800W 3 LOADS MAIN SERVICE PANEL AC GEC KWHRKWHR UTILITY METER (E) 240/120V 1ɸ, 3W 200A BUSBAR 200A MAIN BREAKER (E) 200A CB1 20A 5 6 7 MODULES REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-11 11 MISSION SOLAR MSE310SQ8T 310W 285W 9.76A 9.34A 40.1V 33.2V -0.128V/°C (-0.32%/°C) 20A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1 1 SOLAR EDGE SE3800H-US [240V] 240V UNGROUNDED 40A 3,800W 16.0A 10.5A 480V 99.0% POWER OPTIMIZERS REF.QTY .MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY PO1-11 11 SOLAR EDGE P320 320W 15A 11.0A 48V 98.8% PASS-THRU BOXES AND COMBINERS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 GENERIC GEN-AWB-TB-2-4X OR EQUIV. 30A 240VAC / 600VDC OCPDS REF. QTY. RATED CURRENT MAX VOLTAGE CB1 1 20A 240VAC SYSTEM SUMMARY OPTIMIZER MAX OUTPUT CURRENT 15A OPTIMIZERS IN SERIES 11 NOMINAL STRING VOLTAGE 380V ARRAY OPERATING CURRENT 9A ARRAY STC POWER 3,410W ARRAY PTC POWER 3,136W MAX AC CURRENT 16A MAX AC POWER OUTPUT 3,800W DERATED AC POWER OUTPUT 3,068W NOTES THE SPECIFIED OPTIMIZER CAN BE SUBSTITUTED WITH A P400, P405, P370, P505, OR P340. THESE OPTIMIZERS HAVE AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF THE MODULE AT THE DESIGN TEMPERATURES, HAVE A MAX INPUT CURRENT RATING THAT IS ABOVE THE MAX OUTPUT CURRENT OF THE MODULE, AND A MAX POWER INPUT THAT IS ABOVE THE RATED POWER OUTPUT OF THE MODULE. 1 UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) 2 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO 690.47(B) AND 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO 250.166 3 MAX DC VOLTAGE OF ARRAY FIXED BY THE INVERTER AT 380V REGARDLESS OF TEMPERATURE. THE MAX DC VOLTAGE OF THE MODULE AT -23°C IS EXPECTED TO BE 46.3V (-23°C - 25°C) X -0.128V/C + 40.12V = 46.3V). 4 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(D). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL.5 THE PV BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD".6 THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER.7 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING 1 1 10 AWG PV WIRE, COPPER FREE AIR N/A N/A 6 AWG BARE, COPPER 0.76 (55°C) 1.0 15A 18.75A 55A 41.8A 75°C 50A 2 1 10 AWG THWN-2, COPPER 0.5" DIA. EMT 2 N/A 10 AWG THWN-2, COPPER 0.76 (55°C) 1.0 15A 18.75A 40A 30.4A 90°C 40A 3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 20A 12 AWG THWN-2, COPPER 0.96 (33°C) 1.0 16A 20A 30A 28.8A 75°C 25A REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: GRID-TIED SOLAR POWER SYSTEMCARMEL, IN 46032611 BEAVERBROOK DRNTS SINGLE-LINE DIAGRAM PV-3 1 PV-3 P-126782 02/06/20 D.M. D.M. 126782 SINGLE-LINE DIAGRAM THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). 03/26/20 Mike Sheeks DC RACEWAYS JB1 - TRANSITION BOX (MODEL NOT SPECIFIED) I1 - INVERTER (SOLAR EDGE SE3800H-US) MSP - MAIN SERVICE PANEL SEE NOTE NO. 3 (DC RACEWAYS) WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.31(E)(3) AND IFC 605.11.1 EACH DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. (JB1, I1) ! WARNING ! ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. NEC 690.35(F) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (JB1, I1) ! WARNING ! ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.17 POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) ! CAUTION ! POWER TO THIS BUILDING IS ALSO FROM ROOF MOUNTED SOLAR ARRAY WITH SAFETY DISCONNECTS AS SHOWN INSTALLED BY RECTIFY LLC DBA RECTIFY SOLAR • (317) 643-1002 NEC 690.56(B) DC DISCONNECT (I1) RATED MPP CURRENT: 9.0A RATED MPP VOLTAGE: 380V MAX SYSTEM VOLTAGE: 480V MAX CIRCUIT CURRENT: 15.0A NEC 690.53 AC DISCONNECT (CB1 IN MSP) MAXIMUM AC OPERATING CURRENT: 16.0A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 SEE NOTE NO. 4 (MSP) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN IFC 605.11.1 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC 705.12(D)(4) SOLAR BREAKER (MSP) ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. NEC 705.12(D)(7) SOLAR BACKFEED BREAKER AS MAIN AC SOLAR DISCONNECT (CB1 IN MSP) PHOTOVOLTAIC AC DISCONNECT NEC 690.14(C)(2) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2011 NEC AND 2012 IFC WILL BE INSTALLED AS REQUIRED. 2 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN COMPLIANCE WITH NEC 690.56(B). 3 LABEL(S) WITH MARKING, "WARNING PHOTOVOLTAIC POWER SOURCE," SHALL BE LOCATED AT EVERY 10 FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND 4 LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN," SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032SAFETY LABELS DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-4 03/26/20 Mike Sheeks ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 22.5FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X6'S), 16IN OC MODULE MECHANICAL PROPERTIES MODEL MISSION SOLAR MSE310SQ8T DIMENSIONS (AREA) 65.5IN X 39.3IN X 1.6IN (17.9 SQ FT) WEIGHT 40.1LB MOUNTING SYSTEM PROPERTIES MAX. ALLOW. RAIL SPAN 112.0IN (ZONE 1) 106.0IN (ZONE 2) 87.0IN (ZONE 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 44.8IN (ZONE 1) 42.4IN (ZONE 2) 34.8IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032ATTACHMENT PLAN DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-5 03/26/20 Mike Sheeks P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032ATTACHMENT DETAILS DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-6 03/26/20 Mike Sheeks GENERAL NOTES 1 CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PV CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO RIDGES, HIPS OR VALLEYS AND SHALL TAKE THE SHORTEST PATHS POSSIBLE BETWEEN ARRAYS AND ELECTRICAL EQUIPMENT TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. PV ELECTRICAL EQUIPMENT BE LOCATED SUCH THAT CONDUIT RUNS ARE MINIMIZED IN THE PATHWAYS BETWEEN ARRAYS. DC WIRING SHALL BE INSTALLED IN METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF LOAD BEARING MEMBERS. (IFC 605.11.2) 2 ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. (IFC 605.11.3.1) 3 PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, 3-FOOT-WIDE (914 MM) ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS/MODULES ARE LOCATED. (IFC 605.11.3.2.2) 4 PANELS/MODULES INSTALLED ON RESIDENTIAL BUILDINGS SHALL BE LOCATED NO HIGHER THAN 3 FEET (914 MM) BELOW THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS. (IFC 605.11.3.2.4) ROOF ACCESS POINT ROOF ACCESS POINT PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE MISSION SOLAR MSE310SQ8T IS TYPE 1. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. P-126782 GRID-TIED SOLAR POWER SYSTEM611 BEAVERBROOK DRCARMEL, IN 46032FIRE SAFETY PLAN DOC ID: 126782-157955-0 DATE: 2/6/20 CREATOR: D.M. REVIEWER: D.M. REVISIONS PV-7 03/26/20 Mike Sheeks MSE PERC 60 High Power PERC Rooſtop Module All-black PERC with 5 busbar technology CERTIFIED RELIABILITY › Tested to 3X IEC Standards › PID Resistant SUPERIOR AESTHETICS › All-black design coupled with outstanding power output › Ideal for residential & commercial applications EXTREME WEATHER RESILIENCE › 5600 Pa snow load (117 psf) › 175 mph wind rating BAA COMPLIANT FOR GOVERNMENT PROJECTS › Buy American Act › American Recovery & Reinvestment Act Mission Solar Energy is headquartered in San Antonio, TX with module facilities onsite. We produce American quality poducts ensuring the highest power output and reliability to our customers. Our product line is well suited for residential, commercial and utility applications. Every Mission Solar Energy product is certified and surpasses industry standard regulations, proving excellent performance over the long-term. 1 5 10 15 20 25 YEARS 97% 80.2% 90.7% 100% 90% 80% 70% Mission Solar Energy Warranty LINEAR WARRANTY 25-YEAR PRODUCT WARRANTY 12-YEAR CEC *As there are different certification requirements in different markets, please contact your local Mission Solar Energy sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CERTIFICATIONS IEC 61215/ IEC 61730/ IEC 61701 UL 1703 CLASS LEADING POWER OUTPUT MAXIMUM EFFICIENCY POSITIVE POWER TOLERANCE High-Power, American Quality RESIDENTIAL | COMMERCIAL www.missionsolar.com | info@missionsolar.com TM ELECTRICAL SPECIFICATIONS MSE305SQ8T 305 18.35 0˜+3% 9.664 40.10 9.202 33.14 20 MSE300SQ8T 300 18.05 0˜+3% 9.571 40.08 9.058 33.12 15 MSE310SQ8T 310 18.65 0˜+3% 9.760 40.12 9.345 33.17 20 Wp % A V A V Pmax Isc Voc Imp Vmp Module Type Electrical Parameters at Standard Test Conditions (STC) Power Output Module Efficiency Tolerance Short-Circuit Current Open Circuit Voltage Rated Current Rated Voltage Fuse Rating CERTIFICATIONS & TESTS IEC UL UL 1703 listed 61215 / 61730 / 61701, Salt mist CEC TEMPERATURE COEFFICIENTS OPERATING CONDITIONS SHIPPING INFORMATION MECHANICAL DATA 44°C (±2°C) -0.427%/°C -0.318%/°C 0.042%/°C Maximum System Voltage Operating Temperature Range Maximum Series Fuse Rating Fire Safety Classification Front & Back Load (UL standard) Hail Safety Impact Velocity 1,000VDC -40°C (-40°F) to +90°C (194°F) 20A Type 1, Class C 5600 Pa (117 psf) 25mm at 23 m/s Solar Cells Cell orientation P-type Mono-crystalline Silicon (156.75mm) Voltage [V] Current-voltage characteristics with dependence on irradiance and module temperature Front View Back View MSE310SQ8T: 310WP, 60CELL SOLAR MODULE CURRENT-VOLTAGE CURVE BASIC DESIGN (UNITS: mm)Content [A]60 cells (6x10), 5 busbar 1664mm x 999mm x 40mm (65.51 in. x 39.33 in. x 1.57 in.) 18.2 kg (40.1 lb) 3.2mm (0.126 in.) tempered, Low-iron, Anti-reflective coating Anodized aluminum alloy Ethylene vinyl acetate (EVA) Protection class IP67 with 3 bypass-diodes PV wire, 1m (39.37 in.), 4mm MC4 or compatible 2 / 12 AWG Module dimension Weight Front Glass Frame Encapsulant J-Box Cables Connector Panels 936 728 Height 45.15” Pallets 36 28 Weight 1,160lbs 305 W 285.48 kW 222.04 kW Width 45.00” Length 66.00 Double stack Double stack Panels 26Pallet Container FT 53’ 40’ Normal Operating Cell Temperature (NOCT) Temperature Coefficient of Pmax Temperature Coefficient of Voc Temperature Coefficient of Isc 10 20 30 40 0 2 4 6 8 10 12 0 Incident Irrd .=1,000 W/m 2 Incident Irrd.=800 W/m 2 Incident Irrd.=600 W/m 2 Incident Irrd.=400 W/m 2 Incident Irrd.=200 W/m 2 Cells Temp. =25˚C 35.00 Mounting Hole Grounding Hole Drain Hole 832.00 832.00 999.00 297.00 77.00 15.00 10.00 PV-RH701 999.00 1664.50 31.20 4.00 4.50 441.28 299.78 292.81 7.25 16.00 16.50 Mission Solar Energy | 8303 S. New Braunfels Ave., San Antonio, Texas 78235 info@missionsolar.com | www.missionsolar.com PERC 60 CLASS LEADING 300-310W Mission Solar Energy reserves the right to make specifica tion changes without notice 03/26/20 Mike Sheeks POWER OPTIMIZERsolaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEAR WARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018/V01/ENG NAM. Subject to change without notice. (4) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (5) It is not allowed to mix P405/P505 with P320/P340/P370/P400 in one string (6) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (7) For SE14.4KUS/SE43.2KUS: It is allowed to install up to 6,500W per string when 3 strings are connected to the inverter (3 strings per unit for SE43.2KUS) and when the maximum power difference between the strings is up to 1,000W (8) For SE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter (3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2,000W Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72-cell modules) P400 (for 72 & 96- cell modules) P405 (for thin film modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)320 340 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125(2) 83(2) Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc)11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Input Wire Length 0.16 / 0.52 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge PV System Design Using a SolarEdge Inverter(4)(5) Single Phase HD-Wave Single phase Three Phase 208V Three Phase 480V Minimum String Length (Power Optimizers) P320, P340, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(6) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(7) 12750(8)W Parallel Strings of Different Lengths or Orientations Yes 03/26/20 Mike Sheeks INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small UL1741 SA certified, for CPUC Rule 21 grid compliance Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)       Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-  -  - -  Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V - 16 - 24 - - 48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5) ˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated (3) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (5) -40 version P/N: SExxxxH-US000NNU4 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018/V01/ENG NAM. Subject to change without notice. 03/26/20 Mike Sheeks Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet © 2019 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.70 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish Slotted L-Feet Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish CAMO Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Bonding Hardware C O NTINUING E D U C A TIONREGIST E R ED PROVI D E RFlash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit Conduit Mount Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction 03/26/20 Mike Sheeks © 2018 IronRidge, Inc. IN Flush Mount System Certification Letter - 1 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: September 7th, 2018 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge’s Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8” stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) • 2015 International Building Code (IBC-2015) • 2014 Indiana Building Code • 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 0º to 45º. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 45º or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 48”. 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge’s Flush Mount installation manual and other applicable standards for general roof construction practice. © 2018 IronRidge, Inc. IN Flush Mount System Certification Letter - 4 1495 Zephyr Avenue Hayward, CA 94544 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, PE, LEED AP Senior Structural Engineer 03/26/20 Mike Sheeks Tech Brief Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. These new requirements are being adopted throughout the country in 2016. IronRidge Certification IronRidge was the first company to receive a Class A Fire Rating—the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Flush Mount and Tilt Mount Systems were tested on sloped and flat roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system’s ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type-tested modules and fire-rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Burning Brand Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Spread of Flame Test Fire Testing Process System Roof Slope Module Fire Rating* Flush Mount Any Slope Type 1, 2, & 3 Class A Tilt Mount ≤ 6 Degrees Type 1, 2, & 3 Class A *Class A rated PV systems can be installed on Class A, B, and C roofs. Tech Brief © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.20 More Resources Installation Manuals Visit our website for manuals that include UL 2703 Listing and Fire Rating Classification. Go to IronRidge.com Engineering Certification Letters We offer complete engineering resources and pre-stamped certification letters. Go to IronRidge.com Frequently Asked Questions What is a “module type”? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be “grandfathered in”, and will not require re-roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV “system”, and are covered in the certification. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code-compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5”, which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class A fire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire-resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. 03/26/20 Mike Sheeks FLUSH MOUNT INSTALLATION MANUAL - 11 © 2019 IRONRIDGE, INC. VERSION 2.1 FRAMeLeSS MODULe KITS Insert Frameless Kit T-bolt in top rail slot. Place star washer over T-bolt, allowing it to rest on top of rail. Secure module clamps with a hex nut and torque to 80 in-lbs. Þ Tested or evaluated module clamps: • Sunforson silver or black SFS-UTMC-200(B) mid and SFS- UTEC-200(B) end clamps. • Sunpreme silver or black mid and end clamps with part numbers 7500105X where "X" is 1, 5, 6 or 7. • IronRidge silver or black mid and end clamps with part numbers FMLS-XC-001-Y where "X" is E or M and "Y" is B or blank. Þ Follow module manufacturer's installation instructions to install the module clamps. Þ Frameless modules require using a Grounding Lug on every rail. Þ For Sunpreme Modules Only: If required to use slide prevention hardware, see Module Slide Prevention Addendum (Version 1.10). Place Star Washer Module Clamp (80 in-lbs) Grounding Lugs Required on Every Rail MODULe COMPATIBILITY The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, “xxx” refers to the module power rating and both black and silver frames are included in the certification. MAKe MODELS Amerisolar Amerisolar modules with 35, 40 and 50 mm frames AS-bYxxxZ Where "b" can be 5 or 6; "Y" can be M, P, M27, P27, M30, or P30; "xxx" is the module power rating; and "Z" can be blank, W or WB Astronergy Solar Astronergy modules with 30, 35, 40 and 45 mm frames aaSMbbyyC/zz-xxx Where “aa” can be CH or A; "bb" can be 60, 66, or 72; “yy” can be blank, 10 or 12; "C" can M, P, M(BL), M-HC, M(BL)-HC, P-HC, (DG), or (DGT); “zz” can be blank, HV, F-B, or F-BH ; and “xxx” is the module power rating Astronergy frameless modules CHSM6610P(DG)-xxx Where “xxx” is the module power rating Auxin Auxin modules with 40 mm frames AXN6y6zAxxx Where "y" can be M or P; "z" can be 08, 09, 10, 11, or 12; "A" can be F or T; and "xxx" is the module power rating Axitec Axitec Modules with 35 and 40 mm frames AC-xxxY/aaZZb Where "xxx" is the module power rating; "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" can be S or SB Boviet Boviet modules with 40mm frames BVM66aaYY-xxx Where "aa" can be 9, 10 or 12; "YY" is M or P; and "xxx" is the module power rating BYD Where "xxx" is the module power rating; "Y" can be M, P or MH; "aa" can be blank, 125- or 156-; "ZZ" can be 54, 60, 72, 120, or 144; "b" can be S or SB Canadian Solar Canadian Solar modules with 30, 35 and 40 mm frames CSbY-xxxZ Where "b" can be 1, 3 or 6; "Y" can be H, K, P, U, V, W, or X; "xxx" refers to the module power rating; and "Z" can be M, P, MS, PX , M-SD, P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD Canadian Solar frameless modules CSbY-xxx-Z Where "b" can be 3 or 6; "Y" is K, P, U, or X; "xxx" is the module power rating, and "Z" can be M-FG, MS-FG, P-FG, MB-FG, or PB-FG CertainTeed CertainTeed modules with 35 and 40 frames CTxxxYZZ-AA Where "xxx" is the module power rating; "Y" can be M, P or HC; "ZZ" can be 00,01, 10, or 11; and "AA" can be 01, 02, 03 or 04 CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb Where "YY" is CSUN or SST; xxx is the module power rating; "zz" is blank, 60, or 72; and "A" is blank, P or M; "bb" is blank, BB, BW, or ROOF Ecosolargy Ecosolargy modules with 35, 40 and 50 mm frames ECOxxxYzzA-bbD Where "xxx" is the module power rating; "Y" can be A, H, S, or T; "zz" can be 125 or 156; "A" can be M or P; "bb" can be 60 or 72; and "D" can be blank or B FLUSH MOUNT INSTALLATION MANUAL - 12© 2019 IRONRIDGE, INC. VERSION 2.1 MODULe COMPATIBILITY ET Solar ET Solar modules with 35, 40 and 50 mm frames ET-Y6ZZxxxAA Where “Y” can be P, L, or M; “ZZ” can be 60 or 72; “xxx” refers to the module power rating; and “AA” can be WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC Flex Flex modules with 35, 40 and 50 mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module power rating; "YY" can be BB or BC; and "ZZ" can be MAA1B, MAA1W, MAB1W, SAA1B, SAA1W, SAC1B, SAC1W, SAD1W, SBA1B, SBA1W, SBC1B, or SBC1W GCL GCL modules with 35 mm and 40 mm frames GCL-a6/YY xxx Where "a" can be M or P; "YY" can be 60, 72, or 72H; and xxx is the module power rating GigaWatt Solar Gigawatt modules with 40 mm frames GWxxxYY Where “xxx” refers to the module power rating; and “YY” can be either PB or MB Hansol Hansol modules with 35 and 40 frames HSxxxYY-zz Where "xxx" is the module power rating; "YY" can be PB, PD, PE, TB, TD, UB, UD, or UE; and "zz" can be AN1, AN3, AN4, HV1, or JH2 Hanwha Solar Hanwha Solar modules with 40, 45 and 50 mm frames HSLaaP6-YY-1-xxxZ Where "aa" can be either 60 or 72; "YY" can be PA or PB; "xxx" refers to the module power rating; and "Z" can be blank or B Hanwha Q CELLS Hanwha Q CELLS Modules with 32, 35, 40 and 42mm frames and model identifier aaYY-ZZ-xxx where "aa" can be Q. or B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ" can be G3, G3.1, G4, G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-G3, BLK-G3, BFR-G3.1, BLK-G3.1, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-G5, L-G5.1, L-G5.2, L-G5.2/H, L-G5.3, G6, G6+, BLK-G6, L-G6, L-G6.1, L-G6.2, L-G6.3, G7, BLK-G6+, BLK-G7, G7.2, G8, BLK-G8, G8+, BLK-G8+ L-G7, L-G7.1, L-G7.2, L-G7.3, L-G8, L-G8.1, L-G8.2, or L-G8.3; and "xxx" is the module power rating Heliene Heliene modules with 40 mm frames YYZZxxx Where "YY" can be 36, 60, 72, or 96; "ZZ" can be M, P, or MBLK; and "xxx" is the module power rating HT-SAAE HT-SAAE modules with 40 mm frames HT72-156Z-xxx Where "Z" can be M, P, M-C, P-C, M(S), M(VS), M(V), P(V), M(V)-C, P(V)-C; and "xxx" is the module power rating Hyundai Hyundai modules with 33, 35, 40 and 50 mm frames HiY-SxxxZZ Where "Y" can be A, M or S; "xxx" refers to the module power rating; and "ZZ" can be HG, HI, KI, MI, MF, MG, RI, RG(BF), RG(BK), SG, TI, or TG Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY Where "xxx" is the module power rating; and "YY" can be blank, HE, or SE, or SE72 JA Solar JA Solar modules with 35, 40 and 45 mm frames JAyyzz-bbww-xxx/aa Where “yy” can be M, P, M6 or P6; “zz” can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R)(TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); “bb” can be 48, 60, or 72; "ww" can be S01, S02, S03, S09, or S10; “xxx” is the module power rating; and “aa” can be MP, SI, SC, PR, 3BB, 4BB, 4BB/RE, 5BB Jinko Jinko modules with 35 and 40 mm frames JKMYxxxZZ-aa Where "Y" can either be blank or S; "xxx" is the module power rating; "ZZ" can be P, PP, M; and "aa" can be blank, 60, 60B, 60H, 60L, 60BL, 60HL, 60HBL, 60-J4, 60B-J4, 60B-EP, 60(Plus), 60-V, 60-MX, 72, 72-V, 72H-V, 72L-V, 72HL-V or 72-MX Jinko frameless modules JKMxxxPP-DV Where "xxx" is the module power rating Kyocera Kyocera Modules with 46mm frames KYxxxZZ-AA Where "Y" can be D or U; "xxx" is the module power rating; "ZZ" can be blank, GX, or SX; and "AA" can be LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 4BC, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, 6BC, 6FC, 8BC, 6MCA, or 6MPA LG LG modules with 35, 40 and 46 mm frames LGxxxYaZ-bb Where "xxx" is the module power rating; "Y" can be A, E, N, Q, S; "a" can be 1 or 2; "Z" can be C, K, T, or W; and "bb" can be A3, A5, B3, G3, G4, K4, or V5 Longi Longi modules with 30, 35 and 40 mm frames LRa-YYZZ-xxxM Where "a" can be 4 or 6; "YY" can be blank, 60 or 72; "ZZ" can be blank, BK, BP, HV, PB, PE, PH, HBD, HPB, or HPH; "xxx" is the module power rating Mission Solar Mission Solar modules with 40 mm frames MSEbbxxxZZaa Where "bb" can be blank or 60A; "xxx" is the module power rating; "ZZ" can be blank, MM, SE, SO or SQ, and "aa" can be blank, 1J, 4J, 4S, 5K, 5T, 6J, 6S, 6W, 8K, 8T, or 9S Mitsubishi Mitsubishi modules with 46 mm frames PV-MYYxxxZZ Where "YY" can be LE or JE; xxx is the module power rating; and "ZZ" can be either HD, HD2, or FB 03/26/20 Mike Sheeks FLUSH MOUNT INSTALLATION MANUAL - 13 © 2019 IRONRIDGE, INC. VERSION 2.1 MODULe COMPATIBILITY Motech IM and XS series modules with 40, 45 and 50 mm frames Neo Solar Power Neo Solar Power modules with 35 mm frames D6YxxxZZaa Where "Y" can be M or P; xxx is the module power rating; "ZZ" can be B3A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF), ME or ME (TF) Panasonic Panasonic modules with 35 and 40 mm frames BHNxxxYYzzA Where "xxx" refers to the module power rating; "YY" can be either KA, SA or ZA; "zz" can be either 01, 02, 03, 04, 06, 06B, 11, 11B, 15, 15B, 16, 16B, 17, or 18; and "A" can be blank, E or G Peimar Peimar modules with 40 mm frames SGxxxYzz Where “xxx” is the module power rating; “Y” can be M or P; and “zz” can be blank, (BF), or (FB) Phono Solar Phono Solar modules with 35, 40 and 45 mm frames PSxxxY-ZZ/A Where xxx refers to the module power rating; "Y" can be M or P; "ZZ" can be 20 or 24; and "A" can be F, T or U Prism Solar Prism Solar frameless modules BiYY-xxxBSTC Where "YY" can be 48, 60, 60S, 72 or 72S; and "xxx" is the module power rating REC Solar REC modules with 30, 38 and 45 mm frames RECxxxYYZZ Where “xxx” is the module power rating; “YY” can be AA, M, NP, PE, PE72, TP, TP2, TP2M, TP2SM, or TP2S; and “ZZ” can be blank, Black, BLK, BLK2, SLV, or 72 Renesola ReneSola modules with 35, 40 and 50 mm frames JCxxxY-ZZ Where "xxx" refers to the module power rating; "Y" can be F, M or S; and "ZZ" can be Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b Renogy Renogy Modules with 40 and 50 mm frames RNG-xxxY Where "xxx" is the module power rating; and "Y" can be D or P Risen Risen Modules with 35 and 40 mm frames RSMyy-6-xxxZZ Where "yy" can be 60 or 72; "xxx" is the module power rating; and "ZZ" can be M or P Frameless modules RSMyy-6-xxxZZ Where "yy" can be 60 or 72; "xxx" is the module power rating; and "ZZ" can be MDG or PDG S-Energy S-Energy modules with 40 frames SNxxxY-ZZ Where "xxx" is the module power rating; "Y" can be M or P; and "ZZ" can be 10, or 15 Seraphim Energy Group Seraphim modules with 35 and 40 mm frames SEG-6YY-xxxZZ Where "YY" can be MA, MB, PA, or PB; "xxx" is the module power rating; and "ZZ" can be BB, BW, WB or WW Seraphim USA Seraphim modules with 40 and 50 mm frames SRP-xxx-6YY Where "xxx" is the module power rating; and "YY" can be MA, MB, PA, PB, QA-XX-XX, and QB-XX-XX Sharp Sharp modules with 35 and 40 mm frames NUYYxxx Where “YY” can be SA or SC; and "xxx" is the module power rating Silfab Silfab Modules with 38 mm frames SYY-Z-xxx Where "YY" can be SA or LA; SG or LG; "Z" can be M, P, or X; and "xxx" is the module power rating Solaria Solaria modules with 40 mm frames PowerXT xxxY-ZZ Where "xxx" is the module power rating; "Y" can be R or C; and "ZZ" can be AC, BD, BX, BY, PD, PX, PZ, WX or WZ Solarcity Solarcity modules with 40 mm frames SCxxxYY Where "xxx" is the module power rating; and "YY" can be blank, B1 or B2 SolarTech SolarTech modules with 42 mm frames STU-xxxYY Where "xxx" is the module power rating; and "YY" can be PERC or HJT SolarWorld AG / Industries GmbH SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 31, 33 or 46 mm frames SW-xxx Where "xxx" is the module power rating SolarWorld Americas Inc.SolarWorld Sunmodule Plus, Protect, Bisun, XL, Bisun XL, may be followed by mono, poly, duo, black, bk, or clear; modules with 33 mm frames SWA-xxx Where "xxx" is the module power rating Stion Stion Thin film modules with 35 mm frames STO-xxx or STO-xxxA Thin film frameless modules STL-xxx or STL-xxxA Where "xxx" is the module power rating SunEdison SunEdison Modules with 35, 40 and 50 mm frames SE-YxxxZABCDE Where "Y" can be B, F, H, P, R, or Z; "xxx" refers to the module power rating; "Z" can be 0 or 4; "A" can be B,C,D,E,H,I,J,K,L,M, or N ; "B" can be B or W; "C" can be A or C; "D" can be 3, 7, 8, or 9; and "E" can be 0, 1 or 2 MODULe COMPATIBILITY FLUSH MOUNT INSTALLATION MANUAL - 14© 2019 IRONRIDGE, INC. VERSION 2.1 Suniva Suniva modules with 35, 38, 40, 46 and 50 mm frames OPTxxx-AA-B-YYY-Z MVXxxx-AA-B-YYY-Z Where "xxx" is the module power rating; "AA" is either 60 or 72; "B" is either 4 or 5; "YYY" is either 100,101,700,1B0, or 1B1; and "Z" is blank or B Sunpower Sunpower standard (G3 or G4) or InvisiMount (G5) 40 and 46 mm frames SPR-Zb-xxx-YY Where "Z" is either A, E, P or X; “b” can be blank, 17, 18, 19, 20, 21, or 22; “xxx” is the module power rating and “YY” can be blank, BLK, COM, C-AC, D-AC, E-AC, G-AC, BLK-C-AC, or BLK-D-AC Sunpreme Sunpreme frameless modules GXB-xxxYY Where "xxx" is the module power rating; and "YY" can be blank or SL Sunspark Sunspark modules with 40 mm frames SYY-xxZ Where “YY” can be MX or ST; “xxx” is the module power rating; and “Z” can be P or W Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40 and 50 mm frames Talesun Talesun modules with 35 and 40 frames TP6yyZxxx-A Where "yy" can be 60, 72, H60 or H72; "Z" can be M, or P; "xxx" is the module power rating; and "A" can be blank, B, or T Trina Trina Modules with 30, 35, 40 and 46mm frames TSM-xxxYYZZ Where "xxx" is the module power rating; "YY" can be DD05, DD06, DE14, DE15, DEG15, PA05, PC05, PD05, PD06, PA14, PC14, PD14, PE14, or PE15 ; and "ZZ" can be blank, .05, .08, .10, .18, .08D, .18D, 0.82, .002, .00S, 05S, 08S, A, A.05, A.08, A.10, A.18, A(II), A.05(II), A.08(II), A.082(II), A.10(II), A.18(II), H, H(II), H.05(II), H.08(II), HC.20(II), HC.20(II), or M Frameless modules TSM-xxxYY Where "YY" can be either DEG5(II), DEG5.07(II), DEG5.40(II), DEG5.47(II), DEG14(II), DEG14C(II), DEG14C.07(II), DEG14.40(II), PEG5, PEG5.07, PEG5.40, PEG5.47, PEG14, or PEG14.40 Vikram Vikram solar modules with 40 mm frames Syy.ZZ.AAA.bb Where "yy" can be M, P, MBB, MH, MS, MHBB, or PBB; "ZZ" can be 60 or 72; "AAA" is the module power rating; and "bb" can be 03.04 or 05 Winaico Winaico modules with 35 and 40 mm frames Wsy-xxxz6 Where "y" can be either P or T; "xxx" is the module power rating; and "z" can be either M or P Yingli Panda, YGE and YGE-U series modules with 35, 40 and 50 mm frames 03/26/20 Mike Sheeks Tech Brief The Strongest Attachment in Solar IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. FlashFoot2 Twist-On Cap FlashFoot2’s unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2 deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom-design lag bolt allows you to install FlashFoot2 with the same 7/16” socket size used on other Flush Mount System components. Three-Tier Water Seal FlashFoot2’s seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2 is the first solar attachment to pass the TAS-100 Wind-Driven Rain Test. Water-Shedding Design An elevated platform diverts water away from the water seal. © 2016 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Installation Features Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. Rounded Corners Makes it easier to handle and insert under the roof shingles. Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. A B C E B C Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2 is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. A 03/26/20 Mike Sheeks