HomeMy WebLinkAboutM-001-SYMBOLS-AND-NOTES---MECHANICAL-Rev.2MECHANICAL
MECHANICAL SYMBOLS
NEW EQUIPMENT
EHISTING EQUIPMENT
E%ISTING E�UIPMENi TO BE REMOVED OR RELOCATED
NEw oucT
�-1 exisnNcoucr
-__f� EXISTMGDUCTTOBEREMOVEDORRELOCATED
� NEWSl1PP_V�IFFl15ER
� E%ISTINGSUPPLY�IFFUSER
;;i EHISTINGSUPPLYOIFFUSERTOBEREMOVE�ORRELOCATE�
� NEWRIAOREXHAUSTGRILLE
I%I EHISTINGRIAOREXHAUSTGRILLE
ISIFYIIdIH:A:[tlAS.1:Y.11FY[q:lIIIiW:14:U1DWLI�18:laPMAI W
0 I NEWSLOT�IFFUSER
�
;J; I E%ISTINGTHERMOSTATTOBEREMOVE�ORRELOCATE�
—u— uNOERcur000R
CONICAL TAP WITH VO W ME �AM1IPER
— CHR —
—CS-
- RG—
— HS—
— HR—
CONICAL TAP WIO VOLUME DAMPER
AC ABOVECEILING
AFF ABOVEFlNISHE�FLOOR
AI ANALOGINPUT
AO ANALOGOUTPIIT
BF BELOW FLOOR
BFC BELOWFlNISHEDCEILING
BG BELOWGRA�E
GENERAL
O
�
�
UNION
VACUUM BREAKER
P-TRAP
FLOOR �RAIN WI P-TRAP
nueoanw
FLOOR QEANOUT OR GRADE CLEANOUT
PETE'S P WG
GAIIGE COCK
THERMOMETER
F & T STEAM TRAP
STEAM BUCKET TRAP
CONNECT ID EXISTING
—HPR—I HIGHPRESSURECON�ENSAiERETURN
_ � _
_��_
—•••-
-P— POMPFDSANITARVLINE
-- VEMLINE
T �IRECTIONOFSLOPE
oiaecTioN o= F�ow
f'3 EXPANSIONi00P
�� GATEVAWE
�� BUTTERFLYVALVE
� BALLVALVE
�� GLOBEVALVE
AUTOMATIC 3�WAY CONTROL VALVE
�— PLUGVALVEIBAUNCINGCOCK
�_ SOLENOIDVALVE
CHECKVALVE
�O HV�RAULICSHOCKARRESTOR
�F VALVEINVERTICAL
�
m
0
�
m
�
0
�
0
MECHANICAL ABBREVIATIONS
CRII COMPUTERROOMONIT EUH ELECTRICUNITHEAiER OB� OPPOSE�BLA�E�AMPER
CU GGN�ENSWGUNIi FCU FANCOILUNIT R RELOCATE�
DI DIGITALINPUT FPB FANPOWERE�BOX RA RETURNAIR
�0 �IGITALOUTPUT FPI FINSPERINCH SA SUPPLYAIR
�S �ISCONNECTSWITCH GC GENERALCONTRACTOR 11H 11NITHEAiER
E E%ISTING MVD MANUALVOLUMEDAMPER WHP WAiER�SOURCEHEAiPUMP
E�H ELECTRICDUCTHEATER N NEW VAV VARIABLEAIRVALVE
EF EXHAUSTFAN WH WATERHEATER
GENERAL SYMBOLS
SECTION TARGETS PARTWL PNN AN� �ETAIL TARGETS
SHEET�ESIGNATION
KEYE� NOTES
1 1
M-iW M 100
REVISION
SHEEiNUMBER
DETAILTARGETS
�ETAILDESIGNATION
REVISION CLOII�
1
M-1��
SHEETNUMBER
e E�UIPMENTDESIGNATION
�iOP- E�UIPMENT ABBREVIAiION, BOiTOM -
MAkK)
e AIRDEVICEDESIGNATION
�TOP-Epl11PMENTABBREVIATION,BOTfOM11-
MARK)
61ZE OR (E) EHIBTING
(RjRELOGAiE�
51 E � MA%IMUM CFM
INI
DESIGNATION
QOP � E�UIPMENTABBREVIATION)
(BOTfOM-AHUp-SEOUENGEIMAkK)
J�� RETURWRELIEFIE%HAlI5TI0lIT51�E
NON-0ONDITIONED AIR j�IRECTION OF
F�ow�
RELEA5E0 FOR CONSTRIICTI�N �oFF�ow�
Su6ject�ocompliancewlthallregula�ions iIRECTIONOFROW)
of S�a�e antl Local Codes
City of Carmel
r
�un��V�lo•rvalM��_
DATE: 04��2�20
/ _ �
/
I
l
� — —
� PLANOR�ETAIL�ESIGNATION
I
I
/ SHEETNUMBER
CWS RISER�ESIGNATION
� 'TOP-RISERABBREVIATION.BOTTOM-
MARK�
MECHANICAL GENERAL NOTES
A. �FAWINGSISPECIFICATIONS�.MECHANICALORAWINGSISPEQFlCATIONSAREGENERALLVOIAGRAMMATICIN
�6EGT66ESCRIB-ANO ILLUSiRAiE SVSiEMS iNAi WILL VOT IMERFERE WIiH THE
ARCHITECNRALI ST4LCilIRAL COV�IiIONS 0° NE B111L�ING AN� WILL FlT NTOAVAIUBLE S�ACES. CAREFl1LLV
IAV Ol1T ALLWORKTO GONFORM TO THE ARCHTECTU4AL STRUC-ORAL, FlNISH GON�Ii10�5. MA W FACTl1RER
EQOIPNENT I FlXTURE CU-SHEETS ANO WITH OiHEF TRA�ES TO AVOID 085iRUGTI0N5, ANO TOALLOW NE
PROPER INSTALLA ION OF EACi ITEM. CONTRACTOR SHALL 09TNN AL_ ARCHITECTURAL OATA. LOCATIONS OF
WALLS 'A4TITIONS FIXTJRES CEILING HEIGHiS. FlNISHES ETC. FROM ARCHITEC-URAL ]RAWINGS ANO STRUCTLRAL
�ATA LOCATIONS OF PIERS. BEAMS. COWMNS J05T5. ETG. FROM STROGNRAL OiAWINGS. CONTRAGIDYSHAI
PROVIJE OFFSE-5, RELOCATIONS, E-C.. AS REQUIRE� TO MEEf iHIS I�TEM AT NO A��ITIONAL GOSTS
e. coNTRacToocumeNTs: CON aaCrOesr+a_eeaeSPONSie�eroexnMiN-rHecoNraACroOCUM=NrS
Laz�[7iva�b�l�mirnNc Nis eio wrH Paencuue a-reNnom ro eaaoas. oMissioNs coNFucrs wirH
aeowsioNs oF �nws nNo co�es nnvin'c dueisoicTioN coNFucrs aenueeN oenwiNes oR oknwiNcsnvo
sPeaFicnnoNs nNo nMeicuous �eFwinon oF Tne exre�T oF coveence ee-weeN conTencrs. aNvsucn
pISCR=PANCV SHALL B= 9ROUGHT INMEOIAiELV i0 THE ATTENiION FOR CORRECTION SHOUL� ANV OF THESE
ERRORS, OMISSIONS, CONFLICTS, OR AMBIGUITIES E%IST, THE CONTRACTOR SHALL HAVE THEN EXPLAWED AN�
ADJl1STE01N W41iING BEPoRE SIGNING THE CONiRACT OR PROCEEDING WITH THE WORK OTHERWISE, HE SHALL
AT HIS OW� EXPENSE. SUP�LY NE PROPER NATERIALS AN� LABOR TO NAKE G00� ANV �AMAGE OR �EFEGTS IN
MS WORK OR THE RESOLTS OBTAWE� NEREFROM, CAUSE� BY SOCF OISCREPANCY. TFE CONTRACTOR SHALL
MAKE A CA9EFUL EXAMINATION OF THE PREM6E5 AN� THOROUGHLY FAMILIAR¢E HIMSELF WITH 1HE RE�UIREMENTS
OF -HE COVTRACT. UPON COMMENCEMENT OF CONSTRUCTION FOR THE WORK INCLUDED IN iHIS CONTRACT,
THE CONTRACiOR SHALL BE �EEME� i0 HAVE MA�E SUCH A SiUDV OR E%AMINATION AN� ACCEPTS ALL
CONJITIONS.
C. CONFLICTS:WHEREVERCONFLICTSOCCURBENVEEN�IFFERENTPARTSOFTHECONTRACTDOCUMENTS,THE
�`RERTEFIIUANTITY. THE BETTER QUALITY, OR LARGER SIZE SHALL PREVAIL UNLE55 iHE ARCHITECT INFORMS THE
CONTRACTOR OTHERWISE IN WRITING.
�. MECHANICALSYSTEM:CONTRACTORSHALLPROVI�EAMECHANICALINSTALNTIONTHATISCOMPLETEAN�ALL
�1 i ORTEFANCESNECESSARY.REASONABLEWCI�ENTAL.ORCUSTOMARILVINCLU�EDEVENTHOUGH
EACH AND EVERY ITEM IS NOT SPEQFICALLY CALLE� OUT OR SHOWN. iHE CONTRACTOR SHALL PROVIDE ALL
EpUIPMENT, MATERIALS, LABOR, SVPERVISION AN� SERVICE NECESSARY SO AS TO PROVI�E A COMPLETE,
FUNCTIONING MECHANICAL SVSTEM.
E. EpUIPMENi PIPING OUCTWORK: ALLNECWINICALEpUIPMENi,MECHANICALPIPING,DUCTWORK,ETC.SHALLBE
�JERAL LOCAilON55HOWN. CONFORM TO ALL ARCHIiECTURAL AN� STRUCTURAL
CON�ITIONS. PROVI�E ANVA��RIONAL SOPPORTS, HA\GERS, OPENIkGS. ETG. AS REQVIRE�'OR A COMPL'TE
INSTALLATION. MECIANIGAL E�UIPME\T SFALL BE IVS-AL_E� IN ACW F�ANCE WITH MANUFACTUkER'S POBLISHE�
REGOMMEN�ATIONS FOR SEkVICE IN E�DED EXPERIEVCEJ C9AFTSNEN SFALL MAKE THE INSTALLATION OF ALL
EQUIPMENi IV A N�li WORKMANSHIRLIKE �4ANNER_ MECHANICAL EpUIPMzNi SHALL BE AS SCHEDULED OR
naaaoveo enua�allo iNsrnu iN =u�nccoaonNce wirn nu naaucne�s cooes nnviNc duaisoicrioN_
cooR�wnTe aenaeen nu Tenoes aeioa ro srnRT �c,�Nv �NORK. aeovioe noeou,�Te aenw�nce Foa =eoPeR
OPERATION, SERVICEI MAIMENANCE, A k FLOW. EiC.
F. LO�ESAN�OR�INANLES EXECUiEALLWORKFOLLOWIVGLOCAL,STATEAN010RNAT10NALC0�E5.OR01NANCES,
��RNING T1E PARTICl1LAR CLA55 OF WORK INVOLVE�. THE GOVERNING COOESARE MINIMIIM
REpUIREMENTS. THE �dA4VWG5 AN�IOR SPEQFICATIONS SHALL PREVAIL WHERE THE �RAWINGS AREIOR
ACCOMPANYING SPEQFlCATIONS EXCEE� THE CODE RE�UIREMENTS.
G. FEESPNOPERMITS CONTRACTORISRESPONSIBLEFORFILWGANDPAYINGALLFESAVDOBTAININGNECESSARY
PERF➢TS��FlC4TE5 OF INSPEGTION. THE CONTRACTOR SHALL �ELIVERAL_ CERTIFlCATES OF IN3PECTION
TO OWNE91COV5-RUCTION MA�AGER INCLU�ING COPIES WITH MAINTENANGE MANUALS.
H. SHOPIRECOROORAWINGS:CONTRACTORSHALLPROVIDE�ETAILE�ANO�IMENSIO�EJHVACOUCP4�ORKAN�
I�i FbFDRAWINGSFORAPPROVALBVTHEARCHITECT!ENGINEER.�l1RINGTHEWSTALLAT10N
OF iHE WORK, THE CONTRACTOR SHALL KSEP �ETAILE� RE W R�5 OF ANV AN� ALL CHANGES M1'A�E FROM THE
CONTRACT �kAWINGS. AFTER FlNAL CONPLETION kEVISE A SET OF CONTRAC-DkAWINGS TO ILW STRATE THE
WORK ASACTUALLV INS-ALLE�, -HESE RECORD �RAWI�GS SHALL 3E NOTED "ASBl11LT". AN� SUBMITTED TO THE
ARCHITECT I ENGIN2ER FOR REVIEW WITH ALL 0&M NANUALS-
I. EQUIPMENiIPIPINGBUPPORTB'.PROPERLYSUPPORTALLMECIANIGALE�JIPNE�TA��PIPINGWITHINTHE
BOIL�IVG AN� PROVI�E A�EaLAiE PROVISIONS °OR SLO'E A\� ANCIORAGE CON-RACTOR SHALL USE HANGERS,
ROOS ANO WSERTS APPROVE� BY UNDERWRRERS LA30RATORIES FOR THE SERVICE IMEN�ED. SECURELY
SLPPORTEO BV STRUCiURAL MEMBERS NMICH IN TURN ARE SUPPORTED OIRECTLV FROM THE BUILDING
STRUCTIIRE.
J. ELECTRICALEpUIPMENT: �ONOTRUNDLCTWOR4.PIPI\GORLOCATEEqUPMENT.I^IITHRESPECTTO
SWT�116bAh6�PANEC60ARD$ POWER PANELS NOTOR CONTROL CEnTERS OR oRV -YPE TRANSPoRMERS, WITHIN
421NCHE5IN FRONT OF EQUIPMENT. OVER EpUIPMEM1T, OR WIiHIN 361NCHE5 HORIIDNTALLY OF SAME SPACE.
K. MECHANICALEQUIPMENTDUC7PoORKPIPING:�UCTWORKAN�PIPINGSHALLBERUNCONCEALE�ABOVECEILINGS,
INSIOESCHASESi:WLLS,ETC.I V L CATIONSSHOWN,UNLESSNOTE�OTHERWISECONFORMTOALL
ARCHITECTURAL, SiRUCTJRAL, ANO FlNISH CON�ITIONS OF BUIL�ING WHEREVER CONDIiIONS ARISE WHICH WILL
CA1155 NORM1IALLV CONCEALE� M1IATERIALS TO BE E%POSED, IM1IME�IATELY CALL THE SITUATION TO THE ATTENTION
OF iHE ARCHITEC- AN� STOP WORK W THOSE AREAS 11NTIL THE ARCHITECT �IRECTS THE RESUMPTION OF THE
woRK nN� rne aeoceouees To ee Fouoweo.
L. XVACPIPING:SLOPEANDARRANGEHVACPIPINGTOESiABLISHHIGHP0INTSFORAIRELIMINATIONANDLOW
Fb1AT5i�ERMR PROPER �RAINAGE, PROVI�E AIR VENTS AT HIGH POINTS AN� �RAIN VAW ES AT LOW POINT.
CON�ENSAiE PIPE SHALL BE iVPE M, �RAWN TEMPER COPPER TUBING, WROUGHT-COPPER FITfINGS, AN�
so�oEREodoiNTs.
M. TXERMOSiAT51 SENSORS:iHERMOSiAiS I SENSORS SHALL BE MOUNTED AT AB AFF A�PRO%AS SHOWN MA%
�SFRbFiEN6bFN�ACLhN6/OR�00RJAMB. COOR�INATEE%ACTLOCATIONSN9THARCHITECTAN�BEiWEEN
TRA�ESPRIORTOMOIINTING. �ONOTMOl1NTABOVE�IMMERS.
N. FIRE�FIREISMOKEOAMPERS'. FlREANOFlRNSNOKE�AMPERSSHALL9EINSTALLEJASINOICATE�ANOWHERE
�D BV LOGAL CO�ES AN] ORDINA�CES. REFER TOA4CH DWGS; BWLDING CO�E
SOMNAF° I LIFESAFETY PUVS FOR LOCATIONS OF ALL °I�E FESISTANT-RATE� WALLS. CJIJNGS. CHASE51
SFAFTS SMOKE COMPARTMENTS, ANJ LOCATIONS OF EGRE55 CORRI�ORS. PRON�E MEANS TO A�EpUATELY
SERVICEiHEOAMPEFSFU5IBLELINKS,PROVI�EIY X12 NINIMUMMETALACCESSDOORSINAL_GWB�.
CEIUNGS. INSTALL I\ ACCOR�ANCE WITH MANUFACTURER'S RECONMEVOAT10N5 ANo UL LISTInG FOR SERVICE
INTEN�ED. PROVI�E METALSLEEVESAS REQl11REJ.
0. �IICTWORRCONSTRUCTI0N:0UCTWORKSHALLBECONSTRLCTE�ACCOR01NGT056'AC\ASTA��AR�SAA�
PE A�T R�NDFlREOAMPERSIZESSHOWNAREAIRSTREAMDIM6VSIONS-ALLLONGITUDINALAND
TRANSVERSE SEAMS AND DUCi CONNECiIONS SHALL BE SECURELV FASiENE� AND SEALED AIRTIGHi.
P. AIR�EVICES'.CEILWGMOONTE�AIR�EVICESSHALLBELOCATE�APPROXINATELVASSHOWN.FOREXACT
LOCATION ANO FRAME MOUNTING TYPES, REFE9 i0 ARCHITECTURAL RERECTE� CEILING PNN. ALL CEILING
OIFFUSERS TO BE 4-WAY i°PE UNLESS NOTEO OTHEkWISE BYAIFFLOW ARdOWS ON FLOOR PLAN QNSULATE iHE
BACK OF CEILWG DIFFUSERS UNLSS CEILWG SPACE IS USED AS A RETURN AIR PLENUM-) REFER TO
ARCHRECTURAL REFLECiE� CEILING PLAN FOR LOCATIONS OF A_L CEILING FFATURE$ LIGHTS, AIR �EVICES.
FlNISHES. CJLIVG HEIGHTSAN� ELEGTRICAL �RAWINGS FOR SPEAKERS. �ETEGTORS, POWER OUTLETS, ETC AN�
FlRE PROTECTION SHOP �RAWIpGS FOR FlRE SPRINKLER HEA�S. COOR�INATE E%ACT LOCATIONS WITH ARCHITECT
Ano BETWEEN TRAOES PRIOR TO MOIINTWG. �
4. BRANCH�UCiRUN-OUTS'.BRANCH�l1CTRl1N�OlITSTOCEILINGMOUNTE�AIR�EVICESSHALLBE5AME51ZE /g�
INSTALL AS STRAIGHT AS POSSIBLE WIiH LONG RADIUS BENDS WITH CLAMPS TO BEtlBED+YrBOTR�EA4D"✓ALL�'��L
�AMPERS LOCATED ABOVE GYP BD. CEILINGS SHALL BE PROVIDE� WIiH REMOiE DAMPER ACTUATORS EQUAL i0
YOONG REGIILATORS MO�EL
R. TORNINGVANES:TURNINGVANESSHALLBEINSTALLEDINALLELBOWSOFSUPPLVANDRETURNAIRDUCTSAND
�+ ORSPLITTERDAMPERSWIiHE%iERNALADJUSTMENiSATALLRECTANGULARBRANCH�UCT
TAKE-0FFS TO AIR �EVICES. PROVI�E A�EpUATE ACCESS AN� MEANS TO A�JUSi I BALANCE ALL AIR
EHTRACTORS ANO �UCT TANE OFFS.
S. ME�IOMPRESSIIRE�UCTRUN�0Ui5: BRANCHMEDIUMPRESSURE�UCTRUN�OUTSTOVAVAIRTERMINALSSHALL
BEE�ECK, IINLE55 NOTED OiHERWISE. INCREASE �UCi SIZE BY 2" IF GREATER
THAV iC'-0' FROM NAIN AN� i OR NORE THAN 2- 90 JEG ELBOVJS.
T. EOIIIPMENiACCESSPANEL�. ACCESSPANRSSFALLBEPROVIDEDFOREACHLOGATIONWHEREMECHANICAL
E JIPMENi,MANUALVALVESAUTOMAiICCO�TdOLVAWES,AUiONAiIC�AMPEFMECHANISM,FlR=ISMOKE
�AM�E4 E-C. ARE INSiALLE� BHINO FIIRRINGS CHASES, OR �ON�REMOVABLE SIISPEV�ED CEIIJVG. SIZE AV�
PCSI-ION EACH AGCESS PANEL 50 iHAT THE CONCEALE� Epl11PMEM CAN BE PROPERLYSERVIGE� MINIMOM
s¢e snnu ee za�� x za�� dN�ess Fie�n coNoirioNs oicrnle orneawise. �eFeR ro nRcn owcs. i sPecs nvo
cooR�iw,Te wrn ceNeRn� conTRacTOR nN� FOR ex�cr �oenrioN. covoirioNs, saes, FiNisnes. sPecs erc.
ll. REMOTE�AMPERACTUATORS'PROVI�EREMOTE�AMPERACTJATORSFOREACHLOGATIONWhEREVOWMEOAMPE
ARE INSTALLE� BEHIN� FURRINGS, CHASES, OR NO�REMOVABLE SJSPEN�E� GEILING_ SfLEAN� POSITION
REMOTE �AMPER ACiUATORS 50 THA- THE CONCEALE� VO W NE �AHIPERS CAN BE A�JUSTE�. COOR�INATE WITH
ARCHITECT AN� GENERAL CONTRACiOR FORAPPROVAL, EHACT LOCATION, CON�ITIONS, SIZES, FlNISHE$ ETC.
V. BALPNCINGANDREGULATINGDEVICES: HVACSYSTEMSSHALLBEWSTALLE�COMPLETEWITHALLeAIANCINGAN�
RE ULAiIN �EVICE NECES ARVFORTHETABCONTRACTORTOPERFORMHISWORK,COOR�INATEWITHTHETAB
CONTRACTOR TO �ETERMWE THEIR EXACT RE�UIREMENTS ALL EQUIPMENT SHALL BE STARTE� PER
MANUFACiURER'S SiART�UP INSTRUCiIONS. REPLACE FlLTERS. BELTS, SHEAVES, DAMPERS, VALVES, STARTERS AND
HEAiER5A5NECESSARVPRI0RT0iAB. �
W. TESTING ADJUSTING ANU BALANCING CONTRACTOR SHALL PROVI�E ALL TESTING, A�JOSTING AN� BALANCING
W K I LU�A v F-6AMPERS.BALANCEAIR�EVICESPoR�RAFLFREEAIR�ISTRIBUTION,VERIFV
CORRECTSETPOINT AN] CALIBRATION OF iHERMOSTATS VERIFY ALL SEpUENCE OF OPERATION, STAGING OF
COOLIVGIH2ATIVG AS APPLICABLE. BALA�CE OF CO��E�SOR AVD HEATING WATER S�STEMS. PUMPS, BOILERS,
COOLING i0WER5, NOiE �EFlCIENCIES IN MECHANIGAL SVSiENS, ETG °OR A CORRECTLY OPERATING
MecnnNicn� sys-eN_ conTRncroesnnu Rea�nce nu Fi_Tees nvo c��nn au sTRnine�s_-esTiNc nNo
BALAACING SOBCOVT9ACTOR MIIST BE A MEMBER IN G00� STANJING OF EITFER AA9C OR NEE9 A�� SU9MIT
REPORiON�EBB.AABC.ORSMACNAFORMSFORAPPROVALBVTHE2NGWEER. PROVI�EAiESTA��BALANCE
REPORi TO iHE MECHANICA_ INSPEC-OR Ai iIME OF 9VAL INSPECTION.
x conTancroRsnnwNsuRemeFURN�sHincallowsTuuTionoFnuaRnNcne�ecTRicn�ciRcuirwiRiNc,
coN�urs, =Ro-ecTive oevices, oiscoNnwrs, nNo nccessoaies FORn_� e�ecrRicn� coNrRo� PoweRwiRiNc
ro �cwoe eur vor uMire� ro�, coNrao� anNe_s. ncrunroas, sMOK=_ oerecroas. coNrao� � voroeizeo
�AM�E45. PRESSl1RE MO�IIDFS FlRE�SMO(E �AM�ERS VARIABLE FREpl1ENCV ORNES VAV TERMINALS (24V
TRA�SFORMER� AN� ALL OTHER�20V CONTROLS AS REQUIRE� FORA COMPLETE CONTROLSVSTEM WHEfFER
SFOVJN TO 9E PERFORMEO BV 0 HERS OR NOT. ALL ELECTRICAL'NORK SHALL 9E WSTALLED Ip FULL
ACCOROANC=WIiHHEFWUIREMSN SOFELWTRICALSPECIFlCATIONS.COORDINATEWITHELECTRICAL
caNTancroa.
MECHANICAL DESIGN CRITERIA
DESIGN CRRERIA�
LOCATION�.14585 HAZEL DELL PKWV, CARMEL, IN 46033
LAiIiUDEILONGTITU�E:6p 00 �EGREES NORTH 1860] OEGREES WEST
ELEVATION'.812FEET
WIMER�B'32DEGREESF(988%�
SUMMER DB� 88 ] DEGREES F(04°/ �
SUI�MER WB�. ]4_0 DEGREES F(0 A%)
BUILDING CODES AND STAN
CITV OF CARMEL, INDIANA'.
(PER STATE OF IN�IANA)
STATE OF INDIANA:
201d IN�IANABNL�INGCO�E
2014 INDIANA FlRE CODE
2014 IN�IANA P W MBING CO�E
2014 IN�IANA FUEL GAS CO�E
2014 INDIANA MECHANICAL CODE
2010 IN�IANAENERGYWNSERVI
2009 IN�IANAELECTRICALCO�E
PROJECT WFO'
OCCUPANCV!CLASSIFlCATION:REFERTOARCHRECTURALDRAWINGS
COVSTRUCTION TW E�. aEFER TO ARCHITECTURAL DRAWINGS
BNLOWG AREASiCALCl1LATI0N: REFER TO ARCHITECiURAL DRAWINGS
SW ASSOCIATES
.,ansulting Enqineers
noo aac�rc n�e
sui�e noo
oeues,Tx �szoi
T�I�. 210 39] 0211
SWAenglneers com
� w � z o
Z � �
ZwF � o
O== = Z
i �'v �
��
z0� � m
w�Q � �
0
�
z
¢ �
¢ E
m o
m z
0
m � �
m o m
m
PE 10403
STATE OF
Seals ��
ISSUED FOR BID &
PERMIT
C
0
�
�
� M
U
C O
N �
a)
� z
� J
L.I..� w
_x �
W �
Q
N U
L
C� �
� U
�, Y
N C d
� � J
i WQ
� = J
� aJ N
� � _
t' � �
� (� �
�
� = r
T
J
Q
�
ZA,
W
�
�
�
�
U�
�
Pmlec�Number 3018082
oaie: otiesnms
Sheet Title and Numbec
M-001
SYMBOLSANDNOTES-
No Revision �ate