Loading...
HomeMy WebLinkAboutM-801-DETAILS---MECHANICAL-Rev.2OPEN NIPPLE ABOVE TOP OF DRAIN PAN. C.O. @ EVERV CHANGE IN OIRECTION GRENTER THAN A5 AND AT MAX. OF 25 FEET IMERVALS. FLOOR � oanw WALLCONSTRUCTION PITCH DOWN TOWARD DRAIN, MIN. il8" PER fl. T.S.P.OF FAN PLUS 1" WATER �3\ CONDENSATE DRAIN TRAP DETAIL �; SCALE: N.T.S. WEATHERPROOFALUMINUM HOUSING FANTYPEASSCHE�ULE� eIRDSCREEN SECURE TO CURB WITH STAMLE55 STEEL SCREWS 8" O.C. ALL SIOES. ROOFINSULATIONB MEMBRANE ROOFDECK REFER TO FLOOR PLANS FOR SIZES BIR� SCREEN DRAIN PAN CONDENSATE �RAIN TRAP WITH SUFFlGENT TRFP SEHL TO OFFSET PRESSl1RE AT �RAIN PAN. 2' x A' WOOD NAILER PRE�FAB ROOF CURB WITH BWLT-IN CANT. FlASH 8 COUNTERFLASH WFATHERTIGHT 18" ABOVE ROOF FINISHE� SURFACE. COORDINATE CURB HEIGHT WITHINSULATION THICKNESS TO ACHIEVE THIS �IMENSION ROOFCURBINSULATION �AMPER TVPE AS SCHEDULED s� EXHAUST FAN ON ROOF DETAIL _ SCALE: N.T.S. TYPICAL TAP 1"iHIG(DUGiLWER. SOPPLY�UCTSEE PLAN. MINIMUM�EPTH ]'LFRGERiHAN DUGi iAP. MANUAL VOW ME DAMPER WITH LOCKING HAN�LE AND 2" INSUlATION STAN��OFF. EpUAL TO RUSKIN M�35 45 DEG. MniN oucr C� LOW PRESSURE DUCT DETAIL �J SCALE: N.T.S. oucr s¢E «s�� 016 AW M. INSULATION PROTECiIVE WVER ON EXPOSED PIPING V I / 12"LONG.16 GA.CURVED GALV. STEELSOPGORTFASTENEO TO A"x0" RE�W000 RUNNER ON RAISEO SUPPORT CUFB. (SPACE� @ 8'-0' GENTERS) SEE SPECSFORSIIPGORTS %� PIPE SUPPORT DETAIL '� � - SCALE: N.T.S. RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel � �un��V�lo•rvalM.�� DATE: 04��2�20 DRAIN LW E SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE ORAIN PAN. � C �. HVAC PIPING � SHT.MTLFLASHING q•xy' REDWOOORUNNER O OPPOSEO BLPDEDFMPEF SIIPPLY REcisha. RETURNSIMILAR NOTE WHERE FEGISTER MOUMEO EXPOSE� ON �UCT, iPP TO BE SIZE OF FLANGE ON REGISiER iURN SHEEi MHAL �OWN ANO FASiEN FIANGE WIiH SCREWS � SHEETMEiAL �SULATION RE61SiEF iURNINGVANES BOLTEO i0 SIDE OF TAP L CLINCHLOCNZOOM STOP INSOLPTION PN� TORN SHEET MEiALBACKTO REG.NECN. � � SIDEWALL REGISTER DETAIL u SCALE: N.T.S. ^^`IICAL TAP iNo oucr IUALVOLUME OAMPER EG. m...,V DUCT NPICAL CONICAL TAP e�-o� sanan�c "TEN 1PC ��A� )INAiI IRi HI VALKI o DUCTWORK SUPPORT DETAIL SCALE: N.T.S. SUPPLV DUCT EON FINISH. CONICAL TAP WITH INTEGRAL MANUAL VOLUME DAMPER AND LOCKINGHAN�LE. PROVI�E2'INSUlATI0N5TANDOFFEpUAL TOREXMASTERCB-0-B02 PoRBRANCHESTOHEPARLTERS WITH INTEGRAL DAMPERS, OMIT �AMPER AT BRANCH TAKE OFF. RIGID�UCT J DIFFUSER FLEX �UCT NOTTO EXCEE� 5 SW ASSOCIATES Cansulting Enqineers n00 Pacifc Ave Sui�e 2 W0 oeues,Tx �szoi T�I�. 210 39] 0211 SWAenglneers com aao�ecTx�e�as INSULATE TOP OF DIFFUSER. TYPICALOFALL �IFFUSERS. CEILING TILE �'� DIFFUSER CONNECTION DETAIL � SCALE: N.T.S. MANUAL VOLUME DAMPER E%HAUST AIR DUCT SEE PLAN f FLE%DUCTNOTTO �EXCE}�-lr�rLE�H J .[ _ n� SHEET METALPLENUM FULL SIZE OF GRILLE NECK & MINIMUM OF 3" TALL, INSULATE TOP OF PLENUM ���Jn n�� EXHAUSTGRILLES � 1 T-BAR � BV OTHERS ��1 RETURNIEXHAUST AIR GRILLE DUCT CONNECTION U SCALE: N.T.S. coa TRANSITION REQUIRE� SUPPLY AIR �UCT, SEE PLANS FOR SIZE. i6GAGESHEETMETALSTRAP� SECURETO STRUCTURE, MIN. OF 4. VAV BO% PLAN VIEW BOX LAV-IN CEILING n� �� ELECTRICALCOIL� PRIMARYAIR�UCTJ SEE PLANS FOR SIZE SUPPLYAIR DUCL ELEVATION (� VAV WITH ELECTRIC REHEAT DETAIL '�J SCALE: N.T.S. � w Z � w=� i C �F <�V '', Z W : Qw� _ � _= i >�U � � '. LLJLLQ ' PE 10403 STATE OF Seals �� 0 0 6 0 ¢ � a _ Z � 0 z � K m � O r r - W s Z `o � ` ¢ E p o Z w o � � — � n m � ISSUED FOR BID & PERMIT C � 0 � U C N � i � � �.�..� � Q�J C� � U N C � � N i > _ � � � Q i +- y � C� � _ No Revision T J Q ZA, W � � .� � Z U� M M 0 � � Z J W � � Q U S Y d J J W � J w ¢ 2 � � � V o�e Pmlec�Number 3018082 oaie: otiesnms Sheet Title and Numbec M-801 DETAILS - MECHANICAL RECOMMEN�ATIONS PRIMARY AIR Dl1CT, SEE PLANS FOR SIZE SPLITTER DAMPER