Loading...
HomeMy WebLinkAboutA000.1PLOTTED: March 12, 2020 / Kamlesh Bisht / 2600-IN-MONACO-EC01.DWG A3-EC01 1FB.1English Tudor2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2020 Suzette Schuette3/30/2015 GARAGE RIGHT 2600-Monaco 1837.0000 LOT 16 03/09/2020 BRICK SOLDIER COURSE, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPECSTONE SILL, PER SPEC STONE VENEER, PER SPEC 1214 ARCHED STONE SOLDIER COURSE, PER SPEC1214 1214 1214 1214 BRICK SOLDIER JACK ARCH, PER SPECBOX BAY w/ 8" TRIM BOARDS, PER SPECHARDIE PANEL (SMOOTH), PER SPEC \A1;2'-7" SCALE:FRONT ELEVATION1/4" = 1'-0"- 8:128:12 \A1;10'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT\A1;9'-2{\H0.750000x;\S1#2;}"\A1;PLATE HEIGHT\A1;8'-0" \A1;13'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT \A1;3'-6"\A1;MIN. \A1;R7'-1" \A1;2'-1" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC 1214 SHAKE SIDING, PER SPEC 1214 1214 BRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC 8:12 8:12 8:12 2030 FX \A1;3'-0" STONE SILL, PER SPECSTONE VENEER, PER SPEC 12"x36" PANEL SHUTTERS, PER SPECBLACKOUT WINDOW, TYP. 1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC \A1;2'-1" BRICK VENEER, PER SPEC \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. \A1;10'-0" \pxi-4,l4,ql,t3;POT VENTS "A"3474ROOF AREA:SQ. FT. 14:12 8:12 8:12 SCALE:ROOF PLAN1/8" = 1'-0"- 8:128:12 8:12 8:12 8:12 8:12 14:12 14:12 14:12 14:1214:12 14:1214:12 \A1;24'-0" 8:128:12 14:12 14:12 \A1;8'-0" 8:128:12 128 4" CORNER BOARD, PER SPEC 8" FASCIA BOARD, PER SPEC ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING\A1;3'-6"\A1;MIN. 128 128 128 128 STONE SOLDIER COURSE, PER SPECMASONRY WRAP, PER SPEC \A1;2'-6" SCALE:LEFT ELEVATION1/8" = 1'-0"- ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" 128 STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC4" FRIEZE, PER SPEC 10" FRIEZE, PER SPEC 128 12812 128 \A1;2'-6" BRICK WAINSCOTT, PER SPEC SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;3'-6"\A1;MIN. 128 128 128 TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" 4" CORNER BOARD, PER SPEC 8" FASCIA, PER SPECROOF SHINGLES, PER SPEC 1214 1214 4"TRIM, PER SPEC MASONRY WRAP, PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- \A1;11'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT ELEVATION EC01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3474 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.63 5.79 5.51 49.16 13 0 AT EAVE 6.95 5.79 5.69 50.84 0 82.00 TOTAL (MIN)11.58 11.58 11.20 100.00 3 HIGH - RIDGE VENT 4.63 5.79 5.52 49.23 3 0 34.00 AT EAVE 6.95 5.79 5.69 50.77 0 82.00 TOTAL (MIN)11.58 11.58 11.22 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 04/01/20 Adam Schriner