HomeMy WebLinkAboutA000.1PLOTTED: March 12, 2020 / Kamlesh Bisht / 2600-IN-MONACO-EC01.DWG
A3-EC01
1FB.1English Tudor2 Car Side EntryFront, Side and Rear Elevations, Roof Plan and Ventilation ScheduleIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2020
Suzette Schuette3/30/2015
GARAGE RIGHT
2600-Monaco
1837.0000
LOT 16
03/09/2020
BRICK SOLDIER COURSE, PER SPEC
8" FASCIA, PER SPEC4" FRIEZE, PER SPEC
BRICK VENEER, PER SPECSTONE SILL, PER SPEC
STONE VENEER, PER SPEC
1214
ARCHED STONE SOLDIER COURSE, PER SPEC1214
1214
1214
1214
BRICK SOLDIER JACK ARCH, PER SPECBOX BAY w/ 8" TRIM BOARDS, PER SPECHARDIE PANEL (SMOOTH), PER SPEC
\A1;2'-7"
SCALE:FRONT ELEVATION1/4" = 1'-0"-
8:128:12
\A1;10'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT\A1;9'-2{\H0.750000x;\S1#2;}"\A1;PLATE HEIGHT\A1;8'-0"
\A1;13'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT
\A1;3'-6"\A1;MIN.
\A1;R7'-1"
\A1;2'-1"
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
ROOF SHINGLES, PER SPEC
8" FASCIA, PER SPEC
1214 SHAKE SIDING, PER SPEC
1214
1214
BRICK SOLDIER COURSE, PER SPEC
4" FRIEZE, PER SPEC
8:12
8:12
8:12
2030 FX
\A1;3'-0"
STONE SILL, PER SPECSTONE VENEER, PER SPEC
12"x36" PANEL SHUTTERS, PER SPECBLACKOUT WINDOW, TYP.
1x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC
\A1;2'-1"
BRICK VENEER, PER SPEC
\pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP.
\A1;10'-0"
\pxi-4,l4,ql,t3;POT VENTS
"A"3474ROOF AREA:SQ. FT.
14:12
8:12
8:12
SCALE:ROOF PLAN1/8" = 1'-0"-
8:128:12
8:12
8:12
8:12
8:12
14:12
14:12
14:12
14:1214:12
14:1214:12
\A1;24'-0"
8:128:12
14:12
14:12
\A1;8'-0"
8:128:12
128
4" CORNER BOARD, PER SPEC
8" FASCIA BOARD, PER SPEC
ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC4" FRIEZE, PER SPEC
BRICK SOLDIER COURSE, PER SPECSTONE VENEER, PER SPEC\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING\A1;3'-6"\A1;MIN.
128
128
128
128
STONE SOLDIER COURSE, PER SPECMASONRY WRAP, PER SPEC
\A1;2'-6"
SCALE:LEFT ELEVATION1/8" = 1'-0"-
ROOF SHINGLES, PER SPEC
8" FASCIA, PER SPEC10" FRIEZE, PER SPEC
4" CORNER BOARD, PER SPECHORIZONTAL SIDING, PER SPEC
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
128
STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC4" FRIEZE, PER SPEC
10" FRIEZE, PER SPEC
128
12812
128
\A1;2'-6"
BRICK WAINSCOTT, PER SPEC
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\A1;3'-6"\A1;MIN.
128
128 128
TOP OF PLATEWINDOW HEAD HGT.
TOP OF FLOORTOP OF FOUNDATION
TOP OF FOOTING
\A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;7'-11{\H0.750000x;\S1#2;}"
4" CORNER BOARD, PER SPEC
8" FASCIA, PER SPECROOF SHINGLES, PER SPEC
1214 1214
4"TRIM, PER SPEC
MASONRY WRAP, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"-
\A1;11'-1{\H0.750000x;\S1#8;}"\A1;PLATE HEIGHT
ELEVATION EC01
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3474 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.63 5.79 5.51 49.16 13 0
AT EAVE 6.95 5.79 5.69 50.84 0 82.00
TOTAL (MIN)11.58 11.58 11.20 100.00
3
HIGH -
RIDGE VENT 4.63 5.79 5.52 49.23 3 0 34.00
AT EAVE 6.95 5.79 5.69 50.77 0 82.00
TOTAL (MIN)11.58 11.58 11.22 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
04/01/20
Adam Schriner