HomeMy WebLinkAboutBontrager Residence Electrical Plan 03-30-2020 smoke detector noteS3 S3
SS 3 S GFCIS3
S 3 S GFCIS4
EXISTING Circuit
Wiring to Switch
NEW Wall-wash
Recessed Can
Light
LIVING
ROOM
KITCHEN
DINING
ROOMENTRYHALL
BASEMENTSTAIRHALLWAY
HALF
BATH
PANTRY
NEW Pendant Lights
NEW Ceiling Fan
NEW Recessed Can Lights
1
2
3
4
5
6GFCIGFCI GFCINEW Recessed
Can LightsSNEW Pendant
Light
TM
1 7 6 7 C h r i s t o p h e r L a n e
S p e e d w a y I N 4 6 2 2 4
31 7. 374. 2906
S T U D I O S L L C
th e Electrical Floor Plan Scale: 1/4" = 1'-0 "
B O N T RA G ER RES ID EN C E
3 4 7 0 T A H O E R O A D - C A R M E L , IN D IA N A 4 6 0 3 3
Electrical Key Notes
CREIGHTON
1 Dedicated 15-20 Amp, 120 Volt Circuit &
Single Outlet for Refrigerator-Freezer: refer
to Manufacturer's Specifications for
installation of Outlet for best access & fit.
2 Dedicated 50 Amp, 240 Volt Circuit &
Single Outlet for Wall Oven: refer to
Manufacturer's Specifications for installation
of Outlet for best access & fit.
3 Dedicated 15 Amp, 120 Volt Circuit &
Single Outlet for Beverage Refrigerator:
refer to Manufacturer's Specifications for
installation of Outlet for best access & fit.
4 Dedicated 50 Amp, 240 Volt Circuit &
Single Outlet for Cooktop: refer to
Manufacturer's Specifications for installation
of Outlet for best access & fit.
5 Dedicated 15 Amp, 120 Volt Circuit &
Single Outlet for Garbage Disposal: refer to
Manufacturer's Specifications for installation
of Outlet for best access & fit.
6 Dedicated 15-20 Amp, 120 Volt Circuit &
Single Outlet for Dishwasher: refer to
Manufacturer's Specifications for installation
of Outlet for best access & fit.
3. All Electrical Circuits shall be "home run" to the
Panel (Load Center), typ.
4.
1. All Electrical work shall be in compliance with
the 2009 Indiana Electrical Code (NFPA
70-2008) & the National Fire Alarm Code
(NFPA 72-2002), including all amendments &
local ordinances.
2. Electrical Device locations shown are
diagrammatic only, unless noted otherwise.
Verify-in-field all conditions & coordinate
Electrical Work with all other trades.
All Electrical Boxes for Light Switches to
be installed 48" to the center, above
finished floor, unless noted otherwise.
General Electrical Notes
5. All Electrical Boxes for Duplex Outlets
above Countertops to be installed 45" to
the center, above finished floor.
6. All Electrical Boxes for Duplex Outlets at
ends of Base Cabinets to be installed
27" to the center, above finished floor.
7. All Convenience Duplex Outlets to be 15
Amp, 120 Volt, unless noted otherwise.
8. All GFCI Duplex Outlets to be 20 Amp,
120 Volt, unless noted otherwise.
0 3-20 -20 20
Note: All smoke and CO detectors
will be brought up to current IN code.
04/03/20
Mike Sheeks