Loading...
HomeMy WebLinkAboutBontrager Residence Electrical Plan 03-30-2020 smoke detector noteS3 S3 SS 3 S GFCIS3 S 3 S GFCIS4 EXISTING Circuit Wiring to Switch NEW Wall-wash Recessed Can Light LIVING ROOM KITCHEN DINING ROOMENTRYHALL BASEMENTSTAIRHALLWAY HALF BATH PANTRY NEW Pendant Lights NEW Ceiling Fan NEW Recessed Can Lights 1 2 3 4 5 6GFCIGFCI GFCINEW Recessed Can LightsSNEW Pendant Light TM 1 7 6 7 C h r i s t o p h e r L a n e S p e e d w a y I N 4 6 2 2 4 31 7. 374. 2906 S T U D I O S L L C th e Electrical Floor Plan Scale: 1/4" = 1'-0 " B O N T RA G ER RES ID EN C E 3 4 7 0 T A H O E R O A D - C A R M E L , IN D IA N A 4 6 0 3 3 Electrical Key Notes CREIGHTON 1 Dedicated 15-20 Amp, 120 Volt Circuit & Single Outlet for Refrigerator-Freezer: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 2 Dedicated 50 Amp, 240 Volt Circuit & Single Outlet for Wall Oven: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 3 Dedicated 15 Amp, 120 Volt Circuit & Single Outlet for Beverage Refrigerator: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 4 Dedicated 50 Amp, 240 Volt Circuit & Single Outlet for Cooktop: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 5 Dedicated 15 Amp, 120 Volt Circuit & Single Outlet for Garbage Disposal: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 6 Dedicated 15-20 Amp, 120 Volt Circuit & Single Outlet for Dishwasher: refer to Manufacturer's Specifications for installation of Outlet for best access & fit. 3. All Electrical Circuits shall be "home run" to the Panel (Load Center), typ. 4. 1. All Electrical work shall be in compliance with the 2009 Indiana Electrical Code (NFPA 70-2008) & the National Fire Alarm Code (NFPA 72-2002), including all amendments & local ordinances. 2. Electrical Device locations shown are diagrammatic only, unless noted otherwise. Verify-in-field all conditions & coordinate Electrical Work with all other trades. All Electrical Boxes for Light Switches to be installed 48" to the center, above finished floor, unless noted otherwise. General Electrical Notes 5. All Electrical Boxes for Duplex Outlets above Countertops to be installed 45" to the center, above finished floor. 6. All Electrical Boxes for Duplex Outlets at ends of Base Cabinets to be installed 27" to the center, above finished floor. 7. All Convenience Duplex Outlets to be 15 Amp, 120 Volt, unless noted otherwise. 8. All GFCI Duplex Outlets to be 20 Amp, 120 Volt, unless noted otherwise. 0 3-20 -20 20 Note: All smoke and CO detectors will be brought up to current IN code. 04/03/20 Mike Sheeks