HomeMy WebLinkAbout2020-0409DHa LayoutsProtect untreated woodfrom direct contact withconcreteEnd of joistsat centerlineof supportFace mounthangerTop flangehangerVerify column capacityand beam bearinglength. See currentiLevel® literature.L5L1BEARING ATCOLUMNColumnPlumbingdropSquash blocks and TJI® blocking panelscarry stacked vertical loads (details B1 andB2). Packing out the web of a TJI® joist (withweb stiffeners) is not a substitute for squashblocks or blocking panels.See current iLevel® literaturefor framing connectorsL6Additional nailing or bolting may berequired with side-loaded multiple-memberbeams. Refer to current product literature.CONNECTION OF MULTIPLE PIECESOF TOP-LOADED BEAMS (1)Minimum of 3 rows 10d (3" x 0.128") nails at 12" o.c.Minimum of 4 rows 10d (3" x 0.128") nails at 12" o.c.for 14" and deeper beamsIf using 12d (314") or larger nails, the number ofnailing rows may be reduced by one.(1) Load must be applied evenly across entirebeam width. Otherwise, use connections forside-loaded beams.312" Width Pieces:Minimum of 2 rows 12" bolts at24" o.c. staggered134" Width Pieces:L2P1BEAM ONCOLUMN CAPL3Subfloor adhesive will improve floor performance,and is recommended, when TJI® joists aredoubled at non-load bearingAt parallel partitions, space TJI® joists apart thewidth of the wall for plumbing or HVAC.Additional TJI® joist at plumbing drop (see detail).ShiftedTJI® joistAdditionalTJI® joistINSTALLATION TIPSL4ELEVATEDCOLUMN BASEProtect untreatedwood from directcontact withconcreteP2COLUMN BASEP3L4A2Optionalnon-shrinkgroutL5PTJI® rimjoistDO NOT bevel cutjoistbeyond inside faceof wall.BEAM DETAILSBEARING AT WALLBEARING FOR DOOROR WINDOW HEADERStrap per code if top plateis not continuous overheaderBEAM TO BEAMCONNECTIONBEARING ATCONCRETE WALLH2Bearing plate to beflush with inside faceof wall or beamSee ALLOWABLEHOLESUse B1 or B2 atintermediate bearingswith load bearing orshear wall from aboveH1H3Butting TJI® joistswith blockingpanelsB4B3B2E2A1B1CSExterior DeckAttachmentLAStructuralsheathingDO NOT use sawnlumber for rimboard or blocking.Sawn lumber mayshrink afterinstallation.Braced end wall -see note 3 underWARNINGRim board jointbetween joistsH1L3A3L1Seat cuts must bewithin wall.Drive nails at anangle to minimizesplitting of plateOne 10d (3") box nail eachside of member at bearing,112" minimum from endSee framing plan (if applicable)or Structural Framer's PocketGuide for minimum end andintermediate bearing lengths.TJI® JOIST NAILING REQUIREMENTS at BEARING134" minimum bearing atend support; 312" minimumat intermediate supportTJI® Joist to Bearing PlateShear transfer: Connections equivalent tofloor panel nailing scheduleOne 8d (212") boxnail each side.Drive nails at anangle at least 112"from end.Squash Blocks to TJI® Joist(Load bearing wall above)One 10d (3") box nailinto each flangeSilent Floor® joist framingdoes not require bridging ormid-span blockingSafety bracing (1x4minimum) at 8' on-center (6'on-center for TJI®Joists)andextended to a braced end wall.Fasten at each joist withtwo 8d (212") nails minimum(see WARNING).TJI® joists must be laterally supportedat cantilever and end bearings byblocking panels, hangers, or directattachment to a rim board or rim joist.E1DO NOT cut, notch or drillholes in headers except asindicated in illustrationsand tables.For simple span (5' minimum), uniformly loaded joists used in residential applications, one maximum size round hole may be locatedat the center of the joist span provided no other holes occur in the joist.Distances are based on the maximum uniform loads shown in current Weyerhaeuser product guides. For other load conditions or holeconfigurations contact your Weyerhaeuser representative.Holes may be located vertically anywhere within the web. Leave 18" of web (minimum) at top and bottom of hole.Knockouts are located in web at approximately 12" on-center; they do not affect hole placement.Trus Joist® TimberStrand® LSL,Trus Joist® TJ® rim board,or Trus Joist® TJI® blocking for lateral supportAlso see detail B21.3E TimberStrand® LSL allowed hole zoneddMicrollam® LVL andParallam® PSLallowed hole zonemiddle 13 span1.3E TimberStrand®LSL hole zoneMicrollam® LVLand Parallam®PSL hole zone2 x diameter of thelargest hole (minimum)d13 depth1"2"134"MAXIMUM ROUNDHOLE SIZEHEADER DEPTH438"714" to 20"512"See illustration for Allowed Hole ZoneOther Trus Joist® Headers and Beams1.55E TimberStrand®LSL Headers and BeamsALLOWABLE HOLES - Headers and Beams13 depth2 x diameter of thelargest hole (minimum)2 x diameter of thelargest hole (minimum)Allowed hole zone8"8"See illustration for allowed hole zone1114"-11 78"14" to 16"914"-912"HEADER DEPTHMAXIMUM ROUNDHOLE SIZE358"458"3"No holes in headers or beams in plank orientation.Round holes onlyGeneral NotesGeneral NotesNo holes in headers or beams in plank orientation.Allowed hole zone suitable for uniformly loaded headers and beams only.Round holes onlyNo holes in cantilevers.BEAM ATTACHMENT at BEARINGThis sheet is intended as a supplement to the Structural Framer's Pocket Guide, which should be referenced for additional information. 112" knockoutsat approximately12" on-centerTHINK SAFETY-READ INSTALLATION INFORMATION BEFORE PROCEEDINGAllowable Load400475Allowable load determined in accordance with AC 124.Corrosion-resistant fasteners required for wet-service applications.114" TimberStrand®LSL rim boardEXTERIOR DECK ATTACHMENTStructural exterior sheathingSee fastenertable below. Maintain2" distance (minimum) fromedge of ledger to fastener.8" diameter maximum hole for 1178" -16" deep blocking panels; 6" diametermaximum for TJI® blocking panels912" deep or shorter than 12" long.Do not cut flanges.TJI® blockingpanelGENERAL JOIST ASSEMBLY DETAILSH1Face mount orTop flange hangerE1E1WWeb stiffenersrequired eachside at E1WA18" diameter maximum hole for 1178" - 16"deep TJI® blocking panels; 6" diametermaximum for TJI® blocking panels 912"deep or shorter than 12" long.Do not cut flanges.Attach reinforcementto TJI® joist with 8d (212")common nails at 6" on-center. When reinforcingboth sides, stagger nails.Backer block: Install tightto top flange (tight tobottom flange with facemount hangers). Attachwith ten 10d (3") boxnails, clinched whenpossible.H2Backer blockboth sides of webwith single TJI®joistFiller block: Attach with ten 10d (3") boxnails, clinched. Use ten 16d (312") boxnails from each side with 312" TJI® joistflange widths. Use fifteen nails withTJI® joist depths greater than 16".E3Web stiffeners required ifsides of hanger do notlaterally support at least38" of TJI® joist top flangeE22'-0"maximumFace grainhorizontalH312" lag boltLA38" lag boltFastenerBearing plate:Flush plate with insideface of wall or beamFlashingTreated 2x_ledger*Conventional construction codeminimum for use with A3 only. SeeStructural Framer's Pocket Guide forA3.1-A3.3 installation specifications.Plate nail - 16d (312") boxat 16" on-center*Floor panel nail - 8d (212")common at 6" on-center*Must have 134" minimum joistbearing at ends4'-0" length of34" reinforcementon one side at E2,both sides at E3A2TJI® rim joistA3A3.2A3.1 A3.3Toe nail - 10d (3") boxat 6" on-center*Nail through 2x_, wood backer andTJI® joist web with 2 rows 10d(3") common nails at 6"on-center, clinched. Use 16d (312") nails with312" TJI® joistflange widths.400N.A.118" TJ® rim boardWeb stiffener each side.See sizes below.WTight fitWEB STIFFENER ATTACHMENTGap:18" minimum234" maximumThree 8d (212") box nails, clinched(Three 16d (312") box nails at 312"TJI® joist flange widths112"112"WoodbackerF14'-0"maximumcantilever(uniform loads only)112 timescantileverlengthINTERMEDIATE BEARINGNO LOAD BEARING WALL ABOVEWeb stiffeners requiredeach side at B3WB3WLoad bearing or shear wall above(must stack over wall below)TJI® blockingpanelWeb stiffenersrequired each side atB1W and B2WB2B1B1WB2WB3116"2x4 minimumsquash blocksUse 2x4 minimum squash blocks totransfer load around TJI® joistTJI® blockingpanelCSLoad from above2x4 minimumsquash blocks116"TJI® blocking panels may berequired with shear walls aboveor below (See detail B1)When sheathing thickness exceeds 78",trim sheathing tongue at rim board*F1 applies touniformlyloaded joistsonly.With top flange hangers, backer block requiredonly for downward loads exceeding 250 lbs or foruplift conditions.NOTE: STUCTURAL DOCUMENTS FOR THIS PROJECTPER THE DESIGN PROFESIONAL OF RECORD SHALLSUPERCEDE ALL ASSEMBLIES SHOWN IN THIS SECTION,ALSO REFER TO WEYERHAEUSER PLACEMENT PLANS(AND MATERIAL SCHEDULES) FOR REQUIRED MATERIAL.Coordinate load requirements with the design professional of record.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.PB113 joist span8' max.Apply subflooradhesive to allcontact surfacesOption #3:Option #1:Option #2:Lack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist.Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker orone layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, TimberStrand® Microllam®, Parallam®, Silent Floor®, TJI®, and Trus Joist® are registered trademarks,and Estima™ is a trademark of Weyerhaeuser NR. © 2009 Weyerhaeuser NR Company. All rights reserved.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.TJI® Joist blocking with endblocks installed at 13 joist-spanlocations usingtwo 8d (0.113" x 212")nails or2 12" screws,typical2x_ strapping installed at 13joist-span locations using two2 12" screws per joist, typicalDirectly applied ceilingWhen specified on the layout, one ofthe above bracing options is requiredTrus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.Trus Joist® TimberStrand® LSLor Trus Joist® TJ® rim board.B4End of joist at centerline of support. Blocking panels required.Load bearing or shear wall above (must stack over wall below when present)Web stiffenersrequired eachside at B5WB5Load bearing wall above(must stack over wall below)Per IRC R502.7, blocking required ateach intermediate support in seismicdesign categories D0, D1, and D2.Blocking required at shear wallsabove or below - see detail B1B5WWood Beam Wood PlateCOLUMN DETAILSHanger height mustbe a minimum of 60%of joist depth10'-0" 11'-6"3'-0"1'-0"1'-0" 1'-6" 9'-0"9'-0"6'-6"4'-6"1'-0" 1'-0"1'-0"3601'-0"12'-0"13"SQUARE OR RECTANGULAR HOLE SIZEMinimum distance from edge of hole to inside face of nearest intermediate or cantilever support16'-6"16'-0"18'-0"17'-0"10'-0"13"ROUND HOLE SIZETable B - Intermediate or Cantilever Support11'-0"10'-0"15'-0"13'-6"4'-0" 8'-62'-6"2303'-0"1'-0"1'-0"1'-0"1'-0"3'-0"3'-0"1'-0"1'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"16"14"2305603601'-0"1'-0"1'-0"2305602103601'-0"1'-0"1'-0"1'-0"1178"1'-0"2303601102105602'-0"1'-0"1'-6"2101101'-0"1'-0"9'-6"5'-6"1'-0" 2'-6"1'-0"1'-0"1'-0"1'-6"2'-6"3'-0"1'-0"1'-0"1'-6"2'-0"1'-0"5'-6"5'-6"3'-6"11'-0"10'-0"4'-0"7'-0"6'-6"6'-6"10'-6"13'-6"12'-6"6'-0"9'-6"3'-6"8'-6"6'-0"2'-6" 5'-0"4'-0"1'-0"4'-6"7'-0"2'-0"8'-0"2'-0"1'-6"4'-6"4'-0"10'-0"11'-0"4'-6"12'-0"8'-6"9'-0"8'-6"3"1'-0"2'-6"2'-6"912"TJI®2101102"2'-0"2'-0"5601'-0"4"3'-6"3'-6"612"8'-0"7'-6"878"11"1'-0" 1'-0" 5'-0" 7'-6"7'-6"3'-6"2'-0" 4'-6"2'-0"1'-6"3'-6"2'-6"1'-0"1'-0"1'-0"3'-0"1'-0"1'-0"2'-0"4'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"2'-0"1'-0"3'-0"1'-0"1'-0"13'-0"6'-0"2'-0" 10'-0"10'-6"13'-6"12'-0"11'-0"14'-6"13'-0"1'-0"3'-6"2'-0"5'-0"9'-0"7'-6"1'-0"5'-0"4'-0"2'-6" 6'-6"4'-6"10'-0"9'-0"13'-6"16'-0"14'-6"13'-6"12'-6"15'-0"14'-0"10'-0"12'-0"11'-0"10'-6"10'-0"8'-6"3'-6"5'-0"1'-0"6'-0"9'-6"5'-0"10'-6"3'-0"2'-6"8'-0"7'-0"12'-0"9'-0"9'-6"2'-0"3"3'-0"2'-6"2'-0"1'-6"2"1'-0"4'-0"3'-6"4"612"7'-6"6'-6"11"878"10'-0"3'-0" 4'-6" 11'-0"13"11'-0"11'-0"SQUARE OR RECTANGULAR HOLE SIZE13"6'-0"7'-0"ROUND HOLE SIZEMinimum distance from edge of hole to inside face of nearest end support1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"2'-0"1'-6"1'-0"1'-6"1'-0"2'-0"2'-6"56016"14"1'-0"3602102305601'-0"1'-0"1'-0"2102301101'-0"1'-0"1'-0"1178"912"1102303602101102302101'-6"8'-0"3'-0" 4'-0"1'-6"1'-0"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"1'-0" 1'-0"1'-6"8'-0"5'-6"2'-6"3'-0"6'-6"3'-6"4'-0"9'-0"3'-6"4'-0"3'-0"6'-0"7'-0"5'-6"1'-6"2'-0"3'-0"2'-0"2'-0"3'-6"2'-6"2'-0"2'-0"2'-6"2'-6"3'-6"3'-0"5'-6"6'-6"7'-0"6'-0"Table A - End Support3"JOISTDEPTHTJI®2" 4" 878"11"1'-6"2'-0"1'-6"2'-0"2'-0"3'-6"2'-6"1'-0"1'-6"1'-0"1'-0"1'-6"1'-0"1'-0"3'-0"2'-6"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-6"1'-6"5'-6"4'-6" 8'-0"4'-0"2'-6"1'-0"1'-0"4'-0"2'-0"2'-0"5'-0"2'-0"1'-6"2'-0"3'-0"2'-6"2'-0"9'-6"8'-0"9'-0"8'-0"10'-0"7'-0"6'-6"9'-0"9'-0"8'-6"8'-0"7'-0"6'-0"6'-6"2'-0"3'-6"2'-6"2'-6"2'-6"4'-6"3'-6"3'-0"3'-0"2'-6"2'-6" 3'-6"4'-6"4'-0"7'-6"7'-0"6'-6"6'-0"3"2" 4" 11"878"612"5'-6"5'-0"5'-6"3'-0"3'-0"4'-6"2'-6"2'-0"2'-6"1'-6"4'-6"1'-0"1'-6"3'-6"5'-6"2'-6"2'-6"612"4'-6"5'-0"5'-0"5'-0"5'-6"6'-6"4'-6"3'-6"4'-0"4'-0"7'-0"3'-6"3'-0"6'-0"7'-0"6'-6"5'-0"3'-6"3'-6"5'-0"3'-0"2'-6"2'-6"2'-0"5'-0"1'-6"1'-6"4'-0"6'-0"3'-0"2'-6"5'-6"5'-6"6'-6"5'-0"4'-0"4'-6"5'-0"7'-6"4'-0"3'-6"6'-6"7'-6"7'-0"5'-6"5"5"7"7"1'-6"2'-6"3'-0"5"4'-6"5'-0"2'-6"3'-0"5'-6"1'-0"5'-6"3'-6"3'-6"3'-6"1'-0"2'-0"1'-0"1'-0"1'-0"1'-0"5'-6"7"4'-6"3'-0"2'-0"3'-6"4'-0"4'-0"1'-0"6'-6"6'-0"5'-6"7'-6"2'-6"8'-6"5'-0"7"5"5'-6"6'-6"3'-6"2'-6"5'-6"4'-0"4'-0"1'-6"7'-0"5'-6"5'-0"7'-0"2'-6"8'-0"4'-6"4'-0"6'-6"8'-0"11'-0"6'-0"9'-6"9'-0"10'-0"11'-0"5'-6"7'-6"8'-6"10'-0"6'-0"7'-0"7'-0"JOISTDEPTH2'-0"1'-6"1'-6"3'-0"1'-6"1'-6"1'-0"1'-0"1'-0"21'-0"20'-6"17"15"8"10"6"4" 12"17"15"12"10"8"6"4"16'-0"15'-6"1'-0"1'-0"1'-0"1'-0"18"20"1'-0"5605603603601'-0"1'-0"1'-0"1'-0" 1'-6"1'-0"2'-0"3'-0"3'-0"6'-0"6'-0"12'-0"5'-6"16'-6"11'-0"15'-0"10'-0"6'-0"9'-0"6'-0"3'-0"1'-6"4'-0"1'-0"1'-0"1'-0"1'-0"16'-6"18'-0"16'-6"14'-0"8'-6"7'-0"9'-0"11'-6" 16'-6"12'-6"14'-6"19'-6"17'-6'19'-0"20'-0"19'-6"5"1'-0"1'-0"1'-0"1'-0"1'-6"1'-0"1'-0"1'-0"7" 5"1'-0"1'-0"3'-6"1'-6" 6'-6"4'-0"6'-0"8'-6"7"17"15'-6"15'-6"17"11'-0"10'-6"6"1'-0"1'-0"1'-0"1'-0"18"20"1'-0"3605605603601'-0"1'-0"1'-0"4"1'-0" 2'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"8" 10"10'-0"5'-0"11'-0"5'-0"1'-0"2'-0"7'-0"7'-0"12" 15" 6"1'-6"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"4"12'-0"11'-6"11'-0"10'-0"5'-0"6'-6"4'-0"2'-6"11'-0"9'-6"8'-0"8" 10"13'-6"14'-6"14'-6"14'-0"12'-6'15"12"5"1'-0"1'-0"1'-0"1'-0"7"1'-0"1'-0"1'-0"1'-0"5" 7"1'-0"1'-0"1'-0"1'-0"1'-0"1'-0"3'-0"4'-0" SYMBOL LEGENDBearing Length RequirementsPoint Load (Operator Added)Line Load (Operator Added)Area Load (Operator Added)Beam by OthersDetail Callout Label(See Framer's Pocket Guide)Non-Load Bearing WallJoist Under Wall AboveBBOA10'UWALack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to eachjoist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such asa worker or one layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, and Trus Joist® areregistered trademarks of Weyerhaeuser NR. © 2009 Weyerhaeuser NR Company. All rights reserved.312" wide TJI® floor joistTop View312" wide TJI®rim joist®134" minimum bearing atend support; 312" minimumat intermediate supportTJI® Joist to Bearing Plate114" TimberStrand® LSL oriLevel® 118" rim board or134" wide TJI® rim joist:One 10d (0.128" x 3") nailinto each flange2 116" - 2 516" wide TJI®rim joist: One 16d (0.135"x 312") nail into each flangeShear transfer: Connections equivalent tofloor panel nailing scheduleOne 8d (0.113" x 212")nail each side. Drivenails at an angle atleast 112" from end.312" wide TJI® rimjoist: Toe nail with10d (0.128" x 3")nails, one each sideof TJI® joist flangeRim to TJI® JoistSquash Blocks to TJI® Joist(Load bearing wall above)One 10d (0.128" x 3")nail into each flange114" TimberStrand® LSL oriLevel® 118" rim board.Also see detail B2Locate rim board joint between joists.134" minimum bearing*Conventional construction codeminimum for use with A3 only. SeeiLevel Framer's Pocket Guide forA3.1-A3.3 installation specifications.Plate nail - 16d (312") boxat 16" on-center*Floor panel nail - 8d (212")common at 6" on-center*A3A3.2A3.1 A3.3Toe nail - 10d (3") boxat 6" on-center*118" iLevel™ or 114"TimberStrand®LSL rimboard*When sheathing thickness exceeds 8",trim sheathing tongue at rim boardLoad bearing or shear wall above(must stack over wall below)Blocking panelWeb stiffenersrequired each side atB1W and B2WB2B1B1WB2W116"2x4 minimumsquash blocksUse 2x4 minimum squash blocks totransfer load around TJI® joistCSLoad from above2x4 minimumsquash blocks116"Top flangehangerH1Face mounthangerWeb stiffeners required ifsides of hanger do notlaterally support at least38" of TJI® joist top flangeBacker block: Install tightto top flange (tight tobottom flange with facemount hangers). Attachwith ten 10d (3") boxnails, clinched whenpossible.H2Backer blockboth sides of webwith single TJI®joistFiller block: Attach with ten 10d (3") boxnails, clinched. Use ten 16d (312") boxnails from each side with 312" TJI® joistflange widths. Use fifteen nails with TJI®joist depths greater than 16".With top flange hangers, backer block requiredonly for downward loads exceeding 250 lbs or foruplift conditions. SYMBOL LEGENDBearing Length RequirementsPoint Load (Operator Added)Line Load (Operator Added)Area Load (Operator Added)Beam by OthersDetail Callout Label(See Framer's Pocket Guide)Non-Load Bearing WallJoist Under Wall AboveBBOA10'UWALack of proper bracing during construction can result in seriousaccidents. Observe the following guidelines:1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI® joists must be completely installed and properly nailed.2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also beaccomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay.3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to eachjoist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such asa worker or one layer of unnailed sheathing.5. Ends of cantilevers require safety bracing on both the top and bottom flanges.6. The flanges must remain straight within 1/2" from true alignment.4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system.WARNING NOTES:WARNINGJoists are unstable until braced laterallyBracing Includes:BlockingHangersSheathingRim BoardStrut LinesRim JoistDO NOT stack buildingmaterials on unsheathedjoists. Stack only overbeams or walls.DO NOT walk on joiststhat are lying flat.DO NOT walk on joistsuntil braced.INJURY MAY RESULT.Weyerhaeuser, iLevel®, Microllam®, Parallam®, Silent Floor®, TimberStrand®, TJI®, and Trus Joist® areregistered trademarks of Weyerhaeuser NR. © 2009 Weyerhaeuser NR Company. All rights reserved.312" wide TJI® floor joistTop View312" wide TJI®rim joist®134" minimum bearing atend support; 312" minimumat intermediate supportTJI® Joist to Bearing Plate114" TimberStrand® LSL oriLevel® 118" rim board or134" wide TJI® rim joist:One 10d (0.128" x 3") nailinto each flange2 116" - 2 516" wide TJI®rim joist: One 16d (0.135"x 312") nail into each flangeShear transfer: Connections equivalent tofloor panel nailing scheduleOne 8d (0.113" x 212")nail each side. Drivenails at an angle atleast 112" from end.312" wide TJI® rimjoist: Toe nail with10d (0.128" x 3")nails, one each sideof TJI® joist flangeRim to TJI® JoistSquash Blocks to TJI® Joist(Load bearing wall above)One 10d (0.128" x 3")nail into each flange114" TimberStrand® LSL oriLevel® 118" rim board.Also see detail B2Locate rim board joint between joists.134" minimum bearing*Conventional construction codeminimum for use with A3 only. SeeiLevel Framer's Pocket Guide forA3.1-A3.3 installation specifications.Plate nail - 16d (312") boxat 16" on-center*Floor panel nail - 8d (212")common at 6" on-center*A3A3.2A3.1 A3.3Toe nail - 10d (3") boxat 6" on-center*118" iLevel™ or 114"TimberStrand®LSL rimboard*When sheathing thickness exceeds 8",trim sheathing tongue at rim boardLoad bearing or shear wall above(must stack over wall below)Blocking panelWeb stiffenersrequired each side atB1W and B2WB2B1B1WB2W116"2x4 minimumsquash blocksUse 2x4 minimum squash blocks totransfer load around TJI® joistCSLoad from above2x4 minimumsquash blocks116"Top flangehangerH1Face mounthangerWeb stiffeners required ifsides of hanger do notlaterally support at least38" of TJI® joist top flangeBacker block: Install tightto top flange (tight tobottom flange with facemount hangers). Attachwith ten 10d (3") boxnails, clinched whenpossible.H2Backer blockboth sides of webwith single TJI®joistFiller block: Attach with ten 10d (3") boxnails, clinched. Use ten 16d (312") boxnails from each side with 312" TJI® joistflange widths. Use fifteen nails with TJI®joist depths greater than 16".With top flange hangers, backer block requiredonly for downward loads exceeding 250 lbs or foruplift conditions.