Loading...
HomeMy WebLinkAboutB-2020-00188 Building PlansINTHEEVENTOF UESTIONSREGAR�INGTHECONTRACT Q DONMENTS, SPECIFlCATIONS, EXISTING CONDITIONS Oft DESIGN IMENT, THE CONTRACT00. SHALL BE RESPONSIBLE FOR OBiAINING CURIFlCATION FROM THE ARCHREQ PRIOR TO BID SUBMITTAL AND PROCEEDING WITH ANY WORK IN QUE6TION. THESE CONTRACT DOCUMENTS ARE WTENDED TO DESCRIBE ONLY THE SCOPE AND APPFARANCE OF THE REAL PROPERtt IMPROVEMENTS. INC W DING THE PERFORMANCE AND LEVEL OF QUALITY EXPEQED OF OF ITS COMPONENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL WORK COMPLEfE� AND MATERIALS INSTALLED BE IN FULLCOMPLIANCEATAMINIMUM WITHALLAPPLIUBLE CODES, REGULATIONS, AND ORDINANCES HAVING �URISOICTIONAL AUTHORITY OVER THE PROfECf. THESE CONTRAQ DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRAQOA IN THE DETAILS OF H6 TRADE. THEYAREPERFORMANCESPECIFlCATIONSINTHAT THEY DO REQUIRE THAT ALL MANUFAQUAED ITEMS. MATERIALS AND EQUIPMENT BE INSTALLE� IN STRICT CONFORMANCE TO THE MANUFAQURER'S RECOMMENDED SPECIFICATIONS, EXCEPT IN THE CASE WHERE THE CONTRACTDOCIIMEMSAAEMORESTRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED. BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. ALL WORK SHALL BE WARRAMED SATISFACTORY, IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAft, OR FOR THE PERIOD OF WARRANiY NSTOMARY.OR STIPUTATED FOR THE TRADE CRAFT. OR PRODUQ, WHICHEVE0. I$ LONGE0. ONLT COMPETENT MECHANIC$ CAPABLE OF PRODOCING GOOD WORKMANSHIP NSTOMA0.Y TO THE TRA�E SHOULD eE USED. COMMENCWG WORK 8Y A CONTRAQOR OR SUBCONTRACTOR CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACFS CONCERNED. IF ANY Sl1CH CONDITIONS ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHALL 8E NOTIFlED IMMEDIATELY, AND NO WORK SHALL BE PERFORMED UNTIL THE CONDRIONS ARE CORRKTED THE COMRAQOR SHALL BE RESPONSIBLE FOR FAMILIAAIZING HMSELF WITH THE PROfEQ SCOPE OF WORK, BUILDING STANDARDS. SCHEDULE AND DEADLMES. THE CONTRACTOft SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEA� ITEMS AFFECTING THE PRO�EQ SCHEDULE ANo SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DE WERY DATES FOR SUCH LONG LEAD ITEMS TO THE OWNER. 6" MTL STUDS @ 16" OC WITH 3 LAYERS OF %" GYPSUM WALLBOARD @ EACH SIDE. EXTEND STUDS AND GWB. TO 11NDERSIDE OF DECK AND SEAL BETW EEN GWe AND DECK FOR FIftE RATED ASSEMBLY. PROVIDE SOUND BATTS INSULATION TO MATCH WALL WIDTHAT WALL TYPE WSA ONLY. TYPE W5 TYPE W5A (PROVIDE TWO HOUR RATED UNDERWRITERS LABORATORY WALL ASSEMBLY U/l I OR EQUAL) RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel � �{�n„� i,.va�� DATE: 04��9�20 SCOPE NOTES ALLCONTRACTORORSUPPLIERRE UFSTSFOft ANYSUBMITfALRE UIREDTOBEREVIEWEDMORETHAN Q Q SUBSTITUTIONSOFSPECIFlEDIiEMSSHALLBESUBMITfEDIN THEINITIALREVIEWANDONE I ADDITIONALREVIEW O WRITING,ACCOMPANIEDBYTHEALTERNATNEPRODUCT WILLBECON9DEREDTOBEWEXCESSOFTHESCOPEOF INFORMATION.TOTHEARCHITEQ,NOLATERTHATTEN THEPRO�EQ.THETIMEREQUIREDFORiHIRDAND (IO�BUSINESSDAYS,PRIORTOBIDOPENINGDATE. SUBSEQUENTREVIFNSOFASUBMITfALWILLBEPAIDFOR SUBSTITUTIONSSHALLONLYBECONSIDEREDIFTHEYDO BYTHECONiRAQORTOTHEARCHITECTATTHE NOTSACRIFICEQUALITY,FUNCTIONALITY,APPEARANCEOR ARCHITECT'SSTANDARDBILLINGRATES.PLUSREIMBURSABLE WARRANTY.UNDERNOCIRCUMSTANCESWILLTHE EXPENSES. OW NER BE REQUIRED TO PROVE THAT A PRODUQ PROPOSEDFORSUBSTITUiIONISORISNOTOFEQUAL THECONTRAQORSHALLBERFSPONSIBLEFOR QUALITYTOTHEPRODUQSPECIFlED. UNDERNO VERIFlCATIONOFANYEXISTINGCONDITIONSANDALL CIRCUMSTANCESSHALLTHECONTRALTORSCALETHE CRITICALDIMENSIONSASSOCIATEDWITHTHEPROPOSED DRAWINGSTODETERMINEOIMENSIONS. REFERTOPLANS, WORK. THECONTRACTORSHALLCONFlRMTHATALL SECTIONSAND�ETAIISFORALLDMEN510NAL WORKOUTLINEDWITHINTHECONTRAQDOCUMENTS MFORMATION. CAN BE ACCOMPLISHED AS SHOW N. PRIOR TO BID OPENING. THECONTRAQORSHALWOTIFYTHE THECONTRAQORSHALLBERESPON518LEFORTHE ARCHITECTOFANYCONDITIONSENCOUNTEREDWHICH INSTALLATIONOFALLSELEQE�MATERIAUWHICHSHALL MAVAFFECTBUILDWGCODECOMPLIANCE,LIFESAFETY, BE COMPLETE IN ALL RESPEQS PRIOR TO THE FlNAL ISSUANCE OF CEATIFlCATE OF OCNPANCY, OR ACCEPTANCE,UNLESSOTHERW6ENOTED. COMPLETIONOFTHEPROfECTASDIRECTEDINTHE CONTRAQ DONMENTS. THECONTRACTORSHALLPRESERVEALLPRINTED INSTRUQIONSANDWARRANTYINFORMATIONTHATIS NOADDITIONALFUNDSWILLBEAPPROVEDFORWORK PROVIDEDWITHEQUIPMENTORMATERIALSUSED,AND OMITfE�FAOMTHECONTRACTOR'SBI��l1ETOlACKOF DELNERSAID%tWTEDMATTERTOTHEOWNEAATTHE VERIFlCATIONBYTHECOMRACTOR,EXCEPTAS TIMEOFSU&SfANTIALCOMPLBION.THECONTRACTOR OTHERW6EAPP0.0VE�8YTHEOWNERFORWORK SHALLINSTRUCTTHEOWNERMTHEPROPERUSEOFTHE ASSOCIATEDWITHHIDDENCON�ITIONSWHICHARENOT EQUIPMENTFURNISHEDBYTHEIRTRADE ACCESSIBLEPRIORTOCONSTxUCTION. GENERALCONTRACTORSHALLPROVIDEATHOROUGH REFERTOPROIECTMANUAL�WHENAPPLICAOLE�FOR CONSTRUQIONCLEANINGATPROJEQCLOSEOUT,PRIOR ADDITIONALREQUIREMENTSANDDIRECTIONS. TO PUNCH LIST WALK THROUGH. ALL INTERIOR HNISHES SHALL COMPLY WITH CHAPTER THECONTRACTORSHALLSUBMITSHOPORAwING50FALL BGHT(B)OFTHE20111MERNATIONALBUILDINGGODE FABRICATE�ITEMS,ANDPHYSICALSAMPLESOFALLFlNISH WITHINDIANAAMENDMENTS. MATERIA6 SPEQFlED TO THE ARCHITEQ FOA REVIEW. LIGHT GAGE METAL STUDS; STUDS, THEIR COMPONENTS AEVIEWEDSHOPDftAWING5AND5UBMITfAUBYOTHERS ANDTHEIRCONNEQIONSSHALLBEENGWEEftEDBYA SHALLNOTBECONSIDEREDASPARTOFTHECONTRAQ PAOFESSIONALENGINEEALICENSEDINTHESTATEWHERE DONMENTS.THEARCHITECTASSUMESNORESPONSIBILITY THEPRO�ECTISLOCATED.THEENGINEERSHALLAFFIXTHEIR FORDRAWINGS,SCHEDULES.ANDIORSPECIFlUTIONSFOR SEALANDSIGNANRETOSHOPDRAWINGSAND wORKONTHEPRO�ECTPREPAREDeYOTHERi CALCUlAT10NS5UBMITfEDFORREVIEW. THEARCHITEQWILLREVIEWALLSHOPDRAWINGS, STEELREQUIREDTOTRANSMITGRAVITYAND/ORUTERAL SUBMITTALSANDSAMPLESFORCONFORMITYWITHTHE LOADSTOTHESTRUQURENOTDETAILEDONTHE CONTRACTDONMENTSANDREfURNTHEMTOTHE STRUCTURALDRAWINGSISTHERESPONSIBILITYOFTHE CONTRAQORWITHINSEVEN�1�WORKWGDAYSEXCEPT METALSTUDSUPPLIERTODESIGN,DETAIL,PROVIDEAND AS MAY OTHERW ISE BE PROVIDED FOR 8Y THE OWNER. INSTALL. THECONTRACTORSHALLNOTREPRODUCEANDMARKUP ANY PART OF THE CONTRAQ DONMENTS FOR SUBMITTAL AS A SHOP DRAWING. ANY SUCH SUBMITfAL W ILL 8E REJEQED. METALSTUDSSHALLBEDESIGNE�TOSUPPORTTHELOADS SHOWN IN THE DESIGN DAiA IN ADDITION TO THE WEIGHT OF THE MATERIALS ATfACHED TO THE MEfAL STUDS. METAL STUDS SHALL BE DESIGNED USING THE LOAO COMBINATIONS IN SECTION I6053.1 OF THE INTERNATIONAL BUILDING CODE,1011 EDITION. NO WCREASE IN ALLOWABLE STRES515 ALLOW ED. DERECTION DUE TO UTERAL LOA� SHALL 8E LIMITED TO �y OF THE STUD SPAN. FOR CANTILEVERS, THE DERECTION DUE i0 LATERAL LOAD AT THE END OF THE UNTILEVER SHALL 8E LIMITED T0� OF THE CANTILEVER DIMENSION_ METAL STUD MANUFACTURER SHALL DETERMINE FINAL lAYOUT AND GAUGE OF STUDS TO MEEf THE ARCHITEQl1RAL AND STRUCTURAL REQUIREMENTS. WHERE ROUGH GRPENTRY IS IN CONTACT W ITH THE GROUNR EXPOSED TO WEATHER OR IN AREAS OF HIGH RELATIVE HUMIDITY PROVIDE FAffENERS AND ANCHORAGES WITH A HOT DIP ZINC COATING OF G90 COMPLYING WITH ASTM AI53 OR PROVIDE FAAENERS AND ANCHORAGES OF TYPE 304 STAINLESS STEEL. ALL WOOD SHEATHING TO 8E FlRE TREATED UNLESS NOTED OTHERWISE. AQ ACOUSTICALCEILINGTILE AD�L ADDITIONAL AFF A80VEFINISHE�FLOOR ALUM ALUMINUM ANO� ANODIZED APP APPROXIMATE ARCH ARCHITECT AWT ACOUSTICALWALLTftEATMENT BLDG BUIL�ING BLKG BLOCKING B0. BOTfOMOF BOT BOTfOM BRG BFAAING CAB CABINET C� CONTftOLf01NT Q CEMER LWE CLR CLFAR CMU CONCREfEMASONRYUNIT CONST CONSTRUCTION COL COLUMN CONC CONCREfE CONT CONTINUOUS CPT CARPEf Q CEftAMICTRE CW COIDWATER DB, DTL �BAIL DF �RINKING FOUNTAIN DIA �IAMBER DIM �IMENSION DWG�S) �RAWING�S) EA EACH K EXPOSE�CFLING EIFS EXTERIORINSUUTIONFINUHSYAEM EJ EXPANSION�OINT EL ELEVATION ENG ENGMEER EQ EQUAL EXIff EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR�RAIN FE FlRE EXTINGUISHER UNDERSIDE OF ROOF DECK B.O. STRUCTURE � 3se"MTLSTUDSAT4'0"OC MAXIMUM SPACING. EXTEND TO UNDERSIDE OF STRUQURE ABOVE. STAGGER SOPPORTWG STUDS. 6" MTL STUDS @ 16" OC WITH ONE LAYER OF %" GYPSUM WALLAOARD @ EACH SIDE. EXTEN� STUDS AND GWB TO UNDERSIDE OF DECK AND SEAL BETNEEN GWB AND DECK FOR FIftE RATED ASSEMBLY. PROVIDE SOUND BATTS INSUlATION TO MATCH WALL WIDTH AT WALL TYPE W4A ONLY. TYPE W4 TYPE W4A (PROVIDE ONE HOUR RATED UNDERWRRERSLABORATORY WALL ASSEMBLY U465 OR EQUAL) PROVIDESOUNDBATTS INSULATION TO MATCH WALL WIDTH AT WALL TYPE WtA ONLY. WALL TYPE GENERAL NOTES A. NOTE:WALLHEIGHTASMARKEDONPlAN51N D. BRACEMETALSTUDWALLSTOTOPOF CON�UNQIONWRHWALLTYPESYMBOLWILL STRUQURALSTEELELEMENTS-ABOVECEILING SUPERCEDEWALLHEIGHTSASSHOWNABOVE.SEE PLANE.COORDINATEREQUIREDBRACESPACWG SYM80LSlEGENDTHISSHEET. WITHSTRUCTURALENGINEERPRIORTO BEGINNING CONSTRl1CTI0N. B. PROVIDEDEEPLEGDEFLECTIONTRACKATTOPOF ALLMETALSTl1�WALLSWHEAESTU�SEXTEND E. ftEFEATOR00MFINISHSCHE�ULEFORALLFINISH TOUNDERSIDEOFROOFDECKORARUCTURE SELECTIONS;CEILINGTYPESANDHEIGHTS;AND ABOVE TYPES, SIZES AND LOCATIONS ETC. C. USEMOLDANDMIL�EWRESISTANTGYPSUM F. ALLSTUDWALISCREATINGACONCEALEDWALL WALLBOARDONALLPLUMBINGWALLS.USESIB" SPACETOHAVEFIREBLOCKINGATINTERVALSNOT CEMENTBOARDINSTEADOFGYPBOARDBEHIND EXCEEDINGIO'A"PERII8231BQ013 ALL TILE FINISHES. TYPE W3 TYPE W3A 3 SIB' MTL STUDS @ 16" OC WITH ONE LAYER OF %" GYPSUM WALL80ARD @ EACH SIDE. EXTENO STUDS AND GW8 TO UNDERSIDE OF DEIX AND SEAL TIGHT PROVIDE SOUND BATTS WSULATION TO MATCH WALL WIDTH AT WALL TYPE W3A ONLY. TYPE W2 TYPE W2A 6' MTL STUDS @ 16" OC W ITH ONE IAYER OF %" GYPSUM WALLBOARD @ EACH SIDE. E%TEND GYPSUM BOARD TO MIN OF 4' ABOVE ADJACENT CEILING uNE. WALL TYPES NOT TO SCALE � 15e"MTLSTU�SAT4'0"OC MAXIMUM SPACINQ EXTEND TO 11NDERSIDE0F5TRUCTUREABOVE. STAGGER Sl1PPORTING STUDS. CEILING LINE SEE REFLEQED CEILWG PLAN FOR HEIGHT. 3%" MTL STUDS @ 16" OC WITH ONE LAYER OF �" GYPSUM WALLBOARD @ EACH SI�E. EXTEND GYPSUM BOARD TO MIN OF 4" ABOVE ADJACENT CEILING LWE. PROVIDE SOUND BATTS MSUlATION TO MATCH WALL W IDTH AT WALL TYPE W IA ONLY. TYPE W I FIN FLOOR TYPE WIA ABBREVIATIONS FEC FIREEXTWGUISHERCABWET FW FINISH FLR FLOOR FR FIRERETARDANT FT FEET GA GAUGE GB GRABBAR GC GENERALCONTRACTOR GYPB� GYPSUMBOAA� HDWA HARDWARE HM HOLLOW MBAL HORIZ HORIZONTAL HP HIGH POINT HVAC HEATWG,VENTIUTING.AIRCONDITIONING HW HOTWATER INSUL INSUUTION �si �oisr �i �omT KD KNOCKDOWN KIT KITCHEN IAM IAMINATE lAV LAVATORY LLH LONG LEG HORIZONTAL LLV LONGLEGVERTICAL MAS MASONRY MAT MATERIAL MAX MAXIMUM M8 MARKERBOARD MECH MECHANICAL MEII MEZZANINE MFR MANUFAQURER MIN MINIMUM MO MASONRYOPENING MTL METAL MC NOTINCANTRACT OC ON CEMER OD OUTSI�E �IAMETER OH OPPOSITEHAND OPNG OPENING OPP OPPOSITE OTO OUT TO OUT PlASNM PWffICUMINATE CODE ANALYSIS APPLICABLE CODES INDIANA BUILDING CODE t0141NDIANA BUILDING CODE INDIANA PLUMBING CODE 20121NDIANA PLUMBING CODE INDIANA ELEQRICAL CODE tW91NDIANAELECTRICALCODE INDIANA FlRE CODE 20H INDIANA FlRE CODE INDIANA MECHANIUL CODE EOH INDIANA MECHANICAL CODE INDIANA CONSERVATION CODE 20101NDIANA ENERGYCONSERVATION CODE INDIANA HANDICAPPED ACCESSIBILITY CODE EW9ANSIAII].I ADA ACCES5181LITY GUIDELINES OCCUPANCY(OVERALLBUILDING) CVSSIFlGTION(302J��. OCNPANCY (TENANT SPACE) cvssiFicnnoN (3oz p�. ACCESSORY USES (5083.1): NON-SEPARATED USES (50931g SEfARATED USES (50&33)� AUTOMATICSPRINKLERSVSTEM SPRINKLER SYSTEM REQUIRED (903): SPRINKLER SYSTEM PROVIDED: ALLOWABLE BUILDING HEIGHT TABUUR HEIGHT (503)�. ALLOWABLE BUILDING AREA TABUUR ARFA (503J- BUILDING AREA INCREASE INCREASE FOR SPRINKLERED BUILDING (5063J�. UNLIMITED AREA (501��. FRONTAGEINCREASE�5061�_ I(= (F/P-15) x wf 30 TOTALALLOWABLEAREAWITHINCREASES: Aa=Av f(Ac x I�+�A�x Is) Aa = FlLL IN 58.M.A8 A.l NIA NIA NIA YES YES EXIST FXIST EXIST EXSIT EXIST EXIST PLW� PLYWOOD g PROJECTIONSCREEN QT QUARRVTILE R RISER NA RETURNAIR RB RESILIENTBASE REF kEFEkENCE REFR REFRIGERATOft REQD REQUIRED RO ROUGHOPENING SA SUPPLYAIR SCHED SCHEDULE $CWO SOLIDCOREWOODo00R SEC SECTION SF SQUAREFOOT SIM SIMIUft $PEU $PECIFICATIONS SS STAINLESSAEEL $TO $TANDAR� STL STEEL $TRUQ $TRUCTU0.AL SUSP SUSPENDED TB TACKBOARD TEL TELEPHONE T0. TOPOF TRTD TREATED TV TEL&ISION TYP TYPICAL UNO UNLES$NOTE�OTHE0.W6E Uft UftINAL VCT VINYLCOMPOSITIONTILE VERT VERTICAL viv vEaiFr w FiE�o VT VINYLTILE WI WITH WIO WITHOIJ� WB WOODBASE WC WATERCLOSET WD WOOD WH WATERHFATER WP WORKINGPOINT ACTUAL BUILDING HEIGHT ANO AREA BUILDING AREA�. BUILDING HEIGHT (FEET / k FLOORS��. TENANTAREA TENANTSPACE ACTUAL OCCUPANT LOAD (1001.11) DINING AREA 131] / I S AND KITCHEN 4191100 NO OCNPANT LOAD FOR REAROOMS AND HALL FIRE RESISTIVE REQUIREMENTS (601 AND 601) CONSTRUCTION TYPE�. STRUCTURALFRAME: EXTERIOR BEARING WALLS: IMERIOR BFARING WALLS: EXTERIOR NON�BEARING WALLS: IMERIOR NON-BEARWG WALLS F�ooa mNSTaucTioN: ROOFCONSTRUQION: SHAFTS: FIRE RESISTANCE RATED CONSTROCTION (101, 601, b0E) anTEo ExTEaioa wnus: FIRE SEPARATION DISTANCE UNPROTECTE� OPENING ARFA: INTERIOR WALL AND CEILING FINISH REQUIREMENTS (807) SEE FlNRH SCHEDULE FOR MATERIALS ALL MATERIALS ARE QASS A RATED FIRE PROTECTION SYSTEMS STANDPIPE SYSTEM (905��. PORTABLEFIREE%TINGUISHERS(906J�: FIRE AURM AND DEfECTION SYSTEMS �901�: SMOKE CONTROL SYAEMS (909r SMOKE AND HFAT VENTS (910): EGRE55 MINIMUM WIDTH FACTOA QOOSJ F REQUIkED MINIMUM WIDTH FAOMSPACE QOOSJk MINIMUM NUMBER OF EXITS ( I015J: AQUAL NUMBER OF EXITS: AQUAL WIDTH OF E%ITS�. ALLOWABLE TRAVEL DISTANCE (10161): CORRIDOR CONSTRUCTION (IOI&I): MINIMUM CORAIDOA WIDTH Q018.iF MAXIMUM DEAD END CORRIDOR Q 0189��. E04,5]6 6 ROORS 1,055 90 IB CONC. N/R NIR N/R N/R N/R N/R ZHO�R WA 3P « WA EXIST SEE PLAN WA NIA WA OJS 13.5" 2 3 114" 350' N/R �. 20' SYMBOLS NOT ALL MAY APPLY ( ) OKEYE�NOTE W INDOW OR GLAZED OPENING TAG O IF WINDOW � Wp IF AOREFRONT � SF# IF NRTAINWALL CW# � ACCESSORYTAG �k EQUIPMENTTAG XXX FlNISHTAG RO�OM ROOM TAG NAME X ELEVATIONTAG�INTEAIOROREMEAIOR XXX � x SECTIONCUTATAftE0.S5HOWNSMALLSCAIE XX � � ,� ..^..1 f� �J ENLARGEDPLAN ` JI X%%-X" ELEVATIONTARGET. FlNISHEDFLOOR=0'A" xxx uNo � { � REVISION \! 1 M 1 PLAN OR TRUE NORTH NORTH � BATTINSULATION�WIOTHOFFRAMINGUNO FE FIREEXTINGUISHERWSEMI-RECESSE�CA8INET O PROVIDED I WSTALLED BY GC O SURFACEMOUNiE�FIREEXTINGUISHER FE PROVIDEDIINSTALLEDBVGC 100 DOORWITHDOORNl1M8ER W INDOW OR GLAZED OPENWG � STUDFftAMEDWALL-REFEftTOINDEXSHEEf FORINFORMATION CMU WALL � REFERTOSECTIONSAND DEfAILS � BRICKWALL�REFERTOSECTIONSANDDETAILS EIFS OVER SU&STRATE - REFER TO SECTIONS FOR W IDTH AND PROFlLE � EXISTMGDOOR-REFERTODOORSCHEDULE EXISTMG FRAMED WALL EXISTMG WINDOW WITHSILLAND/ORSTOOL � / DEMO'D DOOR / --- DEMO'DWALL Wy WALLTYPE WALL HEIGHT IF DESIGNATED ON PLANS. IF �T NOT.SEEWALLTYPESTHISSHEET DRAWINGS ARCHITECTURAL A001 INDEX A001 TYPICALACCESSIBILIiTDETAILS AI00 LIFESAFEfYPIAN AI01 FLOORPIAN/ENLARGEDPLANS A110 REFLEQEDCEILINGPLAN A�10 INTERIORELEVATIONS A311 WTERIORDETAILS A610 DOORANDFINISHSCHEDULES MEP ENGINEERING MIO MECHANICALPUN M20 MECHANICALSCHEDUIESAND�ETAl6 M30 MECHANICALSPECIFICATIONS E00 ELECTftICALSPEQFICATIONS E0.1 PANELANDON6LWEDIAGRAMS EIO POWERPUN F10 LIGHTING PIAN PIO PLUM8INGPLAN P30 PLUM8INGSCHEDULESANDDETAIIS P1.0 PLUMBINGSPECIFlCATIONS I � ELM STREET � � � PROJECT LOCATION � N� KEY PLAN � CURRAN AN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMITSET 01181�20 CONSTRUQIONSR 023010t0 190410 INDEX A00 I BAIX WALL a 3 0 ¢ 3 0 SHOWER STALL DIMENSIONS $ in. = r-0. � 2 I� FLOOR TRANSITIONS 9 6" = I'-0" RELEA5E0 FOR CONSTRIlCTION Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM��_ DATE: 04��9�20 0 z� OD 7 V o� RANGES I O IH"= I'-0" i /(.'r��� S� II�� ;II, I NOTES: I. TOPOFGftIPPINGSURFACE33"T036"MAX � SEE NOTES BELOW 1. 12" MINIMUM QEAR ABOVE GRAB BAR 6" TO I3" MAX 36'SSGRABBAR � l3" (E%CEPT @ TANK TOIlfTS, WHICH SHALL BE36" CONTROLS MOUNTEO ON WIDE SIDE OF TOILET AREA 43" SS GRAB 8AR —V ACCESSIBLEROUTE 98' � � � • I e$ I m V — J NOTE: MAINTAINH'MMCLEARAISLE EGRESS PATHS TO EHIT DOORS. 0 ¢ � VERTICAL SS GRAB 8AR � o � IB" T048" AFF FOR OPERABLEOPENING WIOOBSTRUCTION FROM GRAB BAR � �� /I / I I � ACCESSIBLE ROUTES 6 IR"= I'-0" rnu i rcwirv� un�et FREFSTANDING OB�ECI nouNreo oN PosTs oF PYLON MAY OVERHAN( IT' MAX FROM 1]" TO 80 ABOVE FINISH FLOOF OBIECT PRO�ECTION FROM WALL BEfW EEN 1]" T080" ABOVE FINISH FLOOR SHALL PROTRUDE NO MORE THAN 4" OBJEQ PROJEQION FROM WALL LESS THAN t]" ABOVE FINISH FLOOR MAYPROTRUDEANYAMOUNT FLOOR SHALL BE SLIP-RESISTANT SURFACE AND LEVEL WITH MAX Y" CHANGE IN LEVEL z m VERTICAL CLEARANCES 7 IR"= I'-0" TOILET SEAT CAVER DISPENSERSHALLBE MOUMED I Y" (MINJ AELOWGRA9RAIL — — �I z � ry � MIRRORMOUMED@40" AFF MAX TO BOTTOM OF REFLEQING SURFACE FIRE AIARM THERMOSTAT � LAVATORY SWITCHES �INSULATEHOTWATER PULLSTATION � BDRAINPIPES H"MINPROJECTION O1 O � � ^ FROM WALL URINAL — — — — — — — V DRYER J ` Q � � £ PAPERTOWEL _ & DISPENSER � 6" MAX DEPTH X 10" MIN WIDTH TOE CLEARANCE 8" MIN DEPTH X 10" MIN WIDTH KNEESPACE TYPICAL MOUNTING HEIGHTS � in. = r-0. �7 � I0.FAR I I FLOOR I SPACE � � ELWGII� URINAL CLEAR SPACE 4 3/4"= I'-0" sTuo w, i' %6" BLOCKING (OMIT BLOCKING MASONRY OR CONCRETE Wi t/" X 3" E%PANSION ANCHORS AT MASONRY OR CONCREfE WALL. 2-p10XS'SCREWSAT WOODOR AEEL STUD WALL -TYPICAL. � Y x O ¢ r 0 TOILET STALL DIMENSIONS 2 IR"= I'-0" GRA88ARSHALLBEIy'TOt" z � � MAXOUTSIDEDIATYPICAL N� I CLEAR !J FLOOR I �-� SPACE J /B' MIN GRAB BAR DIMENSIONS S 3•-I-0• SINK CLEAR SPACE 3 3H" = I'-0" �OUTLEfS (UON) � 5 a. 3' 0' T-0" I -0" MIN =1£ I � � CLTOILET - z � z � v 4 16"TOIB"MAX /J TOILETPAPER J VERTIUL GRAB BAR � SEE DET I V Z ago O Z Q $ £ O a^a L TYPICAL ADA INFO WATER CLOSET�. WATER CLOSETS SHALL BE I]" TO 19" AFF WHEN MEASURED TO THE TOP OF THE TOILET SEAT AND THE CENTER FOR THE FIXTURE SHALL 8E IB" FROM ONE WALL W ITH A CLEAR FLOOR SPACE OF 60" WIDE AND 59" DEEP FOR FLOOR MOUNT AND 56" DEEP FOR WALL MOUNT. SINK: SINK SHALL BE MOUNTED WITH THE RIM Oft COUNTEft NO HIGHEft THAN 34' AFF PROVIDE A CLFARANCE OF AT LEAST 19' TO THE BOTfOM OF THE APRON W ITH AN 8"Xt]" KNEE SPACE AND 6"X9" TOE SPACE. EXPOSED HOT WATER AND DRlJN PIPES UNDER SINKS SHALL BE INSULATED. FAUCEfSSHALLBELEVER�OPERATED,PUSH-TYPEAND MOTION SENSOR. URINALS: URINALS SHALL BE STALLTYPE OR WALL HUNG W ITH THE RIM AT A MAXIMUM OF I]" AFF ANO A l0" X 48" QEAR FLOOR SPACE. GRA88ARS:GRABBARSSHALLBE33"TOl6"AFF THEGRABBARBEHIN� THE WATER CLOSET SHALL BE 36" LONG AND NO MORE THAN 6" OF OF THE SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42" LONG AND 12" OFF THE BACK WALL. MIRROR: MIRRORS SHALL BE MOUMED 50 THE 80TfOM OF THE RERECTING SURFACE IS NO MORE THAN 40" AFF. PAPER TOWEIIDRYER: PAPER TOWEV DRYERS SHALL 8E MOUNTED NO HIGHER THAN 48" AFF. SOAP DISPENSER�. SOAP DISPENSERS SHALL BE MOUMED NO HIGHER THAN 48" AFF. TOILET PAPER: TOILET PAPER DISPENSERS SHALL 8E WSTALLED WITHIN 3fi" MAX OF THE BAIX WALL. � CURRAN Hn,,,,..���llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 ,�,�,_.:Q�..._„o.. _,92; N o. • I AR19600043 ! • n.h � uaia�s THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHREQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITECN0.E. c� COPVWQIiI019.CIMRANAR6111ECNRE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMITSET OLtB.1020 CONSTRUQIONSET @.30.3010 190410 TYPICAL ACCESSIBILITY DETAILS A002 t]' MA% I CONTROIS GENERAL NOTES A CONTRACTORSHALLBERESPONSIALEFORVERIFICATIONOFALL DIMENSIONS ANDJ08 CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED IN DRAWINGS SHALL 8E BROUGHT TO THE ATTENTION OF THEARCHITECTIMMEDIATELY. B. ALLDIMENSIONSSHOWNAREFACEOFBRIIX,MASONRYORMETAL STUD FRAMINq UNLESS OTHERWISE NOTED. C. PROVIDEDEEPLEGDEFLECTIONTRAIXATALLMETALSTUD CONNEQIONS W ITH STRUCTUftE ABOVE, TYPIUL. o. PftOVIDEFIRERATEDW00�BLOCKINGINMETALSTUDWALLSFOR ANY WALL SUPPORTED ITEMS. E. PROVIDE APPROVED FlRE RATED STOPPING MATERIALS IN ANY OPENINGS W FlRE RATED ASSEMBLIES. E REFERTODOORANDWINDOWSCHEDULESFORALLMATERIALS, FINISHES,AND HARDWARE WFORMATION. G. REFERTOEXTERIORELEVATIONSFORALLBRICK,MASONRY.AND oTHEaExPnNsioN�oiNr�ocnrioNs. H. ALLMATERIALSLOGTEDINCEILINGPLENUMSHALLBERATEDFOR SUCH INSTALLATION OR PROTEQED TO PROVIDE COMPLIANCE THIS WCLU�Es eur Is NOT uMITEo To WSULATION IFHC 25/50) POwER AND LOW VOLTAGE WIRING. TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND D0.AIN LINES AND SUPPORTING BRACKETS ANDIOR BLOCKING FORCEILMG HUNG ITEMS. I. PRIORTOORDERINGANYPRODUQS,CONTRACTORSHALLSUBMIT SAMPLES TO THE ARCHREQ OF ALL FINISH MATERIA6 TO BE USED ON THE PROJEQ. THE CONTRAQOR SHALL BEAR SOLE RESPON51&LITV FORANY MATERIALS ORDERE� MCORREQLY WHEN THAT MATERIAL WAS NOT REVIEWE� BY THE ARCHITECT. f. PftOVIDECONCRETEFILLEDSTEELPIPEAOLUADSATALLREQUIRE� UTILITY EQUIPMENT LOCATIONS SUCH AS GAS MBERS, ELECTRICAL T0.ANSFORMER PANELS, EfC., COORDINATE W ITH UTILITY COMPANY AND CONTRAQORS, WHEN APPLICABLE. FOR NECESSARY LOUTIONS. AEFEA TO CIVIL DRAWINGS FOR 80LLARD SPECIFlUTIONS AND ADDITIONAL MFORMATION. K. ALLDOORS,UNLESSOTHERWISENOTED,TOHAVEHINGESIDESEf4" FROM CORNER SHOWN TO OUiSIDE OF FRAME. L 11NLES55PECIFIEDELSEWHERE,ALLINTERIORSlAB5AND5LABWFlLLS TO BE FF-SOffL35 OVERALL AND FFdS'F615 LOCAL M. ALLEXITDOOftSTOHAVETACTILEEXITSIGNAGEPER]0340FTHE 51 I ].I 09 N. ALLWALLSTOBECONSTRUQEDASWALLTYPEW3AUNLESSNOTE� OTHERWISE ON THE FLOOR PIAN � CURRAN AN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE � `` I � � p�4 II � � � 100 SEATING AREA II � � -'� O � �-------,► � � � ♦ � ` - - �� J � �- -_ -_ �- � �- � TRAVEL DISTANCE 42'�9" J � � � � � � � � � � � � � r � � I� 9nCMFLow PREVENiER � � FE ----------- � ios sroa � � � 1� � � � I I �I 104 I / HALL jjl3 r � IVI � � � I�I— — — LJ5�14 �I � � p,z piz p,o � i V % iox SALES COUNTER I� I � 25 �l � �j� � N�Bqzs ioz KITCHENI STORAGE xauaio z� 19 � � 8 fi „n���20 �'21 ��� 106 I WOMEN � �� � 107 � MEN � , __-� �I JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PEnniTSEr ai.ze.zozo CONSTRUQIONSR 023010t0 RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel � �{�n„� i,.va�i_ DATE: 04��9�20 I � ELM STREET � PROJECT LOCATION LIFE SAFETY PLAN # SCALE � NOftTH KEY PLAN a � > 190410 LIFE SAFETY PLAN AI 00 �� � TR�VELD�STAN�61'-6'� � — — — — — — \\�\�� RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel , ��n„� �,.va�! DATE: 04��9�20 � ENLARGEDPLAN 3 irz.=ro. 100 � SEATING q210 AREA KEYED NOTES I'-6" DEEP X I 12" THICK MDF COUMER, FlNISHE9 WITH ZINC PANEL ON ALL EXPOSED FACES. PROVIDE WELDED CORNER�OIMS.. SUPPoRT FROM WALL WITH IRON SUPPORiS FLOATING COUNTER SUPPORT BRACKET (CONCEALED IN WALL�, MATTE BLACK BRACKET FlNISH. COORDINATE WITH TENANT. 2 EXISTINGWATERSERVICHRPZTOREMAIN.REFERTOPWMBING DRAWWGS. MODIFYASMUCHASPOS518LETOREDUCEOVERALL SPACE TAKEN UP BY PIPING. 3. 4" CONCRBE WITH WIRE MESH, OVER VAPOR BARPoER 0`/ER GRANUTAR FILL REFER TO SHELL BUIL�ING FOR SPECIFICATIONS. PROVIDE 1" RIGID INSUlATION UNDER SUB 4' HORIZOMALLY ALONG NORTH. WEA AND SOUTH WALLS OF SPACE. ELEVATION OF SIAA TO 8E I l4' AAOVE THE EXISTING SIDEVJALK AT DOOR I OOA. 4. ttPIULALLPERIMETERWAL60FSPACEFURROUTWALLSFULL HEIGHT WITH 3 5/8" METAL STUDS R� I I BATT WSULATION. VAPOR BARRIERANDSIB"GWB. EXTENDTODECKANDPROVIDESEALANTAT JOINTBETWEENDDOl1BLETEESANDWALL HOLDSTUDFRAMWGOFF EXTERIOR WALLS BY I/l". 5. REMOVEPORTIONOFCMUWALLFORNEWHOLLOWMETALDOOR. PROVI�E 8" PRECAST LIMEL WITH MIN. B" BFARING ON EACH EN�. GROIfr CORES SOLID BELOW LINTEL EXTEND NEW SLA61N SPACE TO OUTSIDE FACE OF CMU WALL. 6. RELOCATESPRINKLERROWHINTIGHTTOPERIMETERWALL. ]. ALIGN WITH WALLOPENING. 8. BULKHEADA80VE. SEEELEVATIONS 9. SEEPWMBINGDRAWINGSFORSWKS.TYPICAL. 10. WOODSHELVWGWITHLIVEEDGEANDCLEARPOLYURETHANEFINISH. REFER ID ELEVATIONS FOR MO0.E WFORMATION II. Sl4"THK.9lACKMEUMWESHELVING. EASTSHELVINGTOBE24"DEEP, NORTH SHELVING i0 AE I6' oEEP. PROVIDE HEAVY DUTY KV STANDARDS AT 16" SPACING. 8' LON4 9LACK IN COLOR. PROVIDE 6 ROWS OF SHELVING. 12. I B GA STAINLESS AEEL RECESSED DRIP PAN, 5" WIDE X 13'�0" LONG WITH 3 DRAIN LINES AND REMOVABLE PERFORATED SCREEN. AMERICAN COFFEE URN MANUFACTURING CO.. INC FMD 5" NSTOM DRIP TRAY OR APPROVED EQUAL. 13. ADACOMPLIANiWALLMOUNTSINKWITHPROTEQIVECOVER50N SUPPLYIWASTE LWES. REFER TO ENGWEERING DRAWINGS. 14. ADACOMPLIANTTOILET.REFERTOENGWEERINGDRAWMGS. I5. 6" DIA. 5 S. TRASH GROMMR, CENTER ON COUMER AND CA6INET BELOW. 16. MITERLIVEEDGECOUNTERANDPROVIDAITfERFLYJOINTS. I]. OPERABLE PARTITION, MODERNFOL� ACOUST6SEAL 933 PAIAED PANELS. PROVIDE 8 PANELS. EQUAL W IDTHS X I3' TALL.. FlNISH ON PANELSTOBEWC-I ONFINISHSCHE�ULE PROVIDEALLNKESSARY STRUCTURALSUPPORTFORCOMPLETESYffEM. 18. PROVIDEF.R.BLOIXINGINWALLFORTENANTPROVIDEDIGC INSTALLED MONITOR. COORDINATE LOCATION WITH TENANT NEW SLAB TO BE WARPED TO BE FLUSH WITH EXIST. GARAGE SLAB (APPROXIMATELY I V4" FROM ENTRY TO THIS DOOR LOCATIONJ. MINIMIZE SLOPE. PROVIDE 5' AOOP W ITH WIDTH ALIGNED W ITH EXISrING STRIPED PATH (1'-3 IR" WIDEJ. SET FLUSH W ITH NEW SWB. PAOVIDE SLOPE TC EAST AND WEST AT I i t0 SLOPE TO MEET UP WRH EXIAING GARAGE SUB. PROVIDE NEW STRIPING ON SLOPE AND UNDING TO MATCH OPENINGS EXCEPT ENTRY DOOR. N8 TO ALIGN WITH PRECAST PANELTMCKNE55. PROVI�EEXPANSIONfOINTMATERIALBETWEEN EXISTING SIDEWALKAND NEW CURB. ON IMERIOR FACE OF CURB, FURR OUT WALL EQUAL TO KEYNOTE 4 AND PROVIDE W00� WINDOW SILL W ITH STAINED FlNISH. 33. PROVIDEMINIMUMFURRINGALONGTHISWALLTOALLOWFOR PROPER QEARANCE OF OPERABLE PARTRION STACKING. 14. ELIASON PI I PLUS GATE WITH BLAIX FINISH. POST HEIGHT TO BE 3'�6" TALL. II. ALLEXPOSEDGYP80ARDSl1RFACE58ELOW8AIXBARCOUNTERTO BE FINISHED WI FRP-I, TYPICAL TO I' BAIX FROM EDGE OF COl1NTER. 16. MOTORIZEDMECHOSHADEWITHVALANCEATIMERIORSTOREFRONT. SUAMIT SAMPLE TO TENAM FOR COLOR AN� PENFORATION sE�EcrioN. D. PAINTEXTERIOROFFIREEXTINGUISHERCABINETTOMATCHWALL COLOR. AND AS CLOSE TO THE 80TfOM OF THE DOUBLE TEE FUNGE AS SR SR SR SFl SFl SFl IOIA IB I ] 22 TYP I 9 � I A3I0 a O 36 I V 101 I CONFRENCE ROOM I 6 — —� — A210 I , TOILET ACCESSORIES MARN SYMBOL DESCRIPTION MULTI�ROLL TOILEf Tfl � TISSUEDISPENSER�BYGC. MODEL SELEQED BY TENANT BOBRICK B�6806.99 X 36 GRAB BAR GBI ' � FORBACKWALLIB�680699X41 FOR SIDE WALL. 18" GRAB 8AR MOUNTED GB2 @ VEATICALLY. 80BAIIX 66806.99 X I B M I MIRROR PROVIDED BY TENANT, WSTALLED BY GC TDI O TOWELDISPENSER,BYGC MODEL SELEQED BY TENANT SDI � SOAPDISPENSER,BYGC MODEL SELEQED BY TENANT N�I NAPKINDISPOSAL,BYGC O MODELSELEQEDBYTENANT O� I SFI SFS SFl SFl SFl ) SB / � l I BACKROW PREVEMER I FE L — — — — — — — — — — — J � a /�� IB o / I \ ASIO \ � \ � � �Bl9— I 19 � 5 � ENLARGEDPLAN Z irz.=ro. � � � ' 8 ' IO At10 AI01 -----------_ l0 90 At10 g ______________ At10 1 3 ��� i __ ______ i e'IPYs" I � � iIrr — — — — — — — — — — — — — — — — — — — — — — � � O ❑; ��_ ________________ 1___ � s � � � ------- i 9 9 , At10 � ���/� A210 COUMER � _� q A210 I �, 103C qZIO 9 105 STO� 104 HA�I 3'�3�/s" H� e� 103 KRCHENI STORAGE �_�I:���� L 1— WO EN � 106� L-- � 101 / � 107 �\ � �— MEN � 1 . � ��IElil� • I q€ � �� I �::..I i i:��� � _ 4 � CURRAN AN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMITSET 01181�20 CONSTRUQIONSR 023010t0 190410 FLOOR PLAN A101 — � KEYED NOTES I. TYPICALENiIRESPACE PROVIDESPRAYONCLOSEDCELL WSUlATION OVER STRUCTURAL DOUBLE TEES. THICKNESS TO 8E SUCH THAT INSUUTION MAINTAINS AN R 30 RATING. PRO�UCT TO BE COMPLIANT FOR USE IN PLENUM AN� EXPOSED CON�ITIONS AN� MUST BE PAINTABLE. 2 CEILINGFRAMEDWITHMEfALSNDSANDFlNISHEDWITHGWB. COVER ENTIRE CEILING WITH SOUND BATT INSUlATION. FlNISH HEIGHT TO BE 9'-0" AFF 3. BULKHEADFRAMEDWITHMETALSTUDSANDFINISHE�WRHGWB. FINISH HEIGHT TO BE AT ]'�0" AFF. REFER TO SECTION THRU MILLWORK 4. BULKHEADFRAMEDWITHMETALSTl1DSANDFINISHEDWITHGWB. COVEft HOftIZONTAL AND VERTICAL FACES WITH RECLAIMED WOOD. FINISH HBGHT OF BULKHEAD TO ALIGN WITH A��ACENT STOREFRONT. 5. REFERIDELECTRIGLDRAWWGSFORPoWERFOR'COLDBREW" ILLUMINATED LETTERING. LETTERS TO BE CENTERED VERTICALLY ON WLKHEAD. COORDINATE WITH OWNER. 6. RECLAIMEDWOODBEAM,MIN.10"%10"XB'LONG,SUSPENDEDOVER SHELVING W ITH AIRCRAR CABLE, WITH BOTTOM AT IT�O" AFF. LIGHT FIXiURE CORDS TO BE W RAPPED AROUND BFAM AND DRAPED OVER SHELVING. COORDINATE W ITH OWNER ]. OPERABLE PARTITION TRACK. ALIGN WITH CEILING. 8. CEMERFIXTUREONWIpTHOFWIN�OW,WITHBOTTOMOF FIXTURE AT I'fi" AFF 9. CENTERSCONCEONWALLWIDTH.WITHBOTTOMOFFlXTUREAT ]'-0' AFF 10. CENTER FIXTUAE ON W IDTH OF HALLWAY. WITH 80TTOM AT I3'-0' AFF IL SCONCESTOBEMOUNTEDOVERSIGNAGE.COORDINATEWITH OWNER ON WSTALLATION AND MOUNTING HEIGHT Il. SCONCESTOBEMOUNTE�BOTTOMOFFI%Tl1REAT6'E"AFF ❑. GARAGEPRECASTDOUBLETEEABWE,SHOWNFORREFERENCE 14. SCONCECEMEftE�OVERWIDTHOFSINKWITHBOTfOMOF FIXTUftE AT ]'-0" AFF. COORDINATE HBGHT W ITH MI0.ROR BELOW CURRAN AN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 19i:1Gllai�� [K�Ppf.11lyl[d�F1a1 01181�20 0230.30t0 190410 RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel , ��n„� �,.va�i_ DATE: 04��9�20 REFLECTED CEILING PLAN I SCALE REFLECTED CEILING PLAN AI 10 FRP WALL FINISH, FRP� I SOLIDSUftFACECOUNTER AND BACKSPUSH SS-I PLASTIC IAMINATE CABINETS INTERIOR ELEVATION � va^ = v-o� PAIN PAIMED INTERIOR ELEVATION S I l4^ = I'-0^ N� RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel , ��n„� �,.va�i_ DATE: 04��9�20 ATION 9 i �a• = i �-o• BEAM WRH VOOD SHELVES '�RAIXETS�, i TENANT N�.1 4 Vq� COUNTER �TE FRP WALL FINISH, FRP-I SOLIDSURFACECOUNTER AND BACKSPLASH SS-I PVSTIC UMINATE CABWETS MOPSINK FILLER INTERIOR ELEVATION 4 va^ = v-o� ELIASON PI I F PVSTIC IAMINA WP-I, WIT UMINAT INTERIOR ELEVATION S I l4" = I'-0" — — S Z — — _ i — L —`1�� S—T—�___ ,T�TSS .--_ —�� / / � INTERIOR ELEVATION 6 i �a• = i �-o• \ \ � � EXPOSEDSTRUCTUREf PAINTLI PAINT SIGNAGEBYTENAP NSTALLED BY G COORDINATE LIGI LOCATI01 PLASTIC LAMINA ENCLOSUREF( COLDBREW DISPENSE WALLTILE Wl (BACK WALL OM PLASTIC UMINA CA81N E TEE LINE P�] PAINT LINE. P�] ABOVE LINE RECUMED WOOD, N�-I INDIVIDUALLY ILLUMINATED LETTERS, PROVIDED BY TENANT, INSTALLED BV GC REQAIMED WOODTRIM. WT-IINSTALLED VERTICALLY, TYPICALAT ENDS AND MIDDLE OF STOREFRONTASSEMBLY STOREFRONTASSEMBLY PAIf B F INTERIOR ELEVATION I IH"= I'-0' INTERIOR ELEVATION 2 IH"= I'-0" INTERIOR ELEVATION 3 IN"= I'-0" iRUCTURE. P�] P) E � WOOD. WT-I ix�crnucai iAUCTl1RE,P-] PJ E < IALL NT ASSEMBLY ILE HUNG PANEL NT ASSEMBLY IN )PENINGS NOOD �I TQ����N�. fiNi$ii To iT OF WALL )GE WOOD TEA C UMINATE PANEL, WITH PLASTIC ATE PIQURE JG � CURRAN AN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMITSET 01181�20 CONSTRUQIONSR 023010t0 190410 INTERIOR ELEVATIONS A210 FURRED 011i E%T. WALL BEYON� EXTEND COUNTER TOOPERABLE WINDOW FRAME SOLIDSURFACE F11}{y:11➢11: PUSTIC UMINATE CABWR SCHEDULED BASF ]• OPERABLE STOREFRONT EXISTING PRECAST BEYON� TYPIUL FURftED OUT WALL 3 SIB' MTL AUD R-I I INSULATION„ VAPOR BARRIER AND 518" GYP BOARD, INSUTATED SPANDRELGlASS ATCASEWORK CONCRETE NR8.6" ABOVEFLOORSLAB EXISTING WALK. ELEVATION VARIES 1 fW WI� f �/�' NEWCONCRETE , .� SlAB OVER VAPOR � BARRIER AND RIGID INSUUTION CASEWORK DETAIL I O 3/4" = I'-0" VARIES LNEEDGE HARDWOOD COUNTER ACCESSIBLECHASE FOR W IRING DECORATNE IAMINATEPANEL SOLIDSUftFACE COUMER BLACK MELAMINE PICTUREFRAME, SEE ELEVATIONS CASEWORK DETAIL % 3H"= I' 0" FOR WIRING COUNTEA DECORATIVE - � -- �--- LAMINATEPANEL r PLASTIC . ....... PlASTIC IAMINATE IAMINATE PICTURE FftAME � � p� t CABINEf SEEELEVATIONS . , CASEWORK DETAIL H 3l4" = I'�0" BASE AASE ICE MAKER WITH MBAL STUDS AND518"GWB PUSTIC LAMINATE END PANEL BEYOND COUNTER FLOATING WALL BRAIXET, OR EQUAL,AT3'OC WALL BELOW COUNTERTOBE FINISHED M FRP-I iCHEDULED BASE CASEWORK DETAIL 4 3H"= I' 0" PWSTIC LAMINATE PANEL 3 VT' WIDE LAMINATEFILLER PANELBEPNEEN EACH DISPENSER. SEE ELEVATIONS 5"XI3'-0" 5 S. RECESSED DRIP TAAYWIPERF SCREENAND DRAINS IM[iW 18f_�y:11J:Ua FRAMED WITH METALSTUDS AND 518" GWB COLD BREW DISPENSER rENnNr oN PIPWG FROM REF. TO DISPENSER SOLID SURFACE COl1NTER IRON SUPPORTS FLOATWG WALL BRAIXET,OR EQUAL AT 3' OC WALL BELOW COUNTER TO BE FINISHED IN FRP-I SCHEDULED BASE CASEWORK DETAIL S 3l4" = I'�0" SURFACE lTER CASEWORK DETAIL I l/4• - I -0• CASEWORK DETAIL Z 3/4" = I'-0" PlA'. � CURRAN uN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMITSET 01181�20 CONSTRUQIONSR 023010t0 RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel , ��n„� �,.va�i_ DATE: 04��9�20 LAMINATE CABINET WOOD tFACE SOLII a GBWE DOORS. P MA6NETIC ANI SCHEDULED B/SE� CASEWORK DETAIL 6 3/4" = I' 0" PLh UMINATE ERAND 'USH SCHEDULEDBASE� CASEWORK DETAIL 3 3/4" = I' 0" 190410 INTERIOR DETAILS A2 I I CASEWORK DETAIL 9 3/4" = I' 0" ROOM # T-1 T-2 T-3 GR-1 GR-2 GR-3 B-1 B-2 P-1 P—z P-3 P-4 P-5 P-6 P-7 WC-1 WC-2 W�-1 'M-2 'M-3 1M17-4 FRP-1 HW-1 LE-1 PL-1 s,s~ �000 ST-1 ST-2 WP-1 A�T-, ACT-2 ROOM # 100 101 ��2 103 104 105 106 107 MATERIAL MANUFACiURER PLE ARTISTIC TILE PLE ARTISTIC TILE PLE B&F CERAMICS GROUT IAPCREfE GROUT IAPCREfE GROUT IAPCREfE BASE TARKEf BASE TARKEf PAIM SHERWIN WILLIAMS PAIM SHERWIN WILLIAMS PAIM—NOT USE� SHERWIN WILLIAMS PAIM—NOT USE� SHERWIN WILLIAMS PAIM—NOT USE� SHERWIN WILLIAMS PAIM SHERWIN WILLIAMS PAIM SHERWIN WILLIAMS WALL COVERING D.L COUCH WALL COVERING D.L COUCH WALL TILE ELMWOOD RECLAIME WOOD PANELING WALL TILE ARTISTIC TILE WALL TILE MSI STONE WALL TILE B&F CERAMICS FIBERGUSS REINF. PUSTIC MARLRE CABINEf HARDWARE TOB KNOBS LNE EDGE HARDWOOD -- PIASTIC IAMINATE WILSONART SOLID SURFACE MEGANITE STAIN MINWA% STAIN MINWA% WALL PANEL MDC ACOUSiICAL CEILING TILE ARMSTRONG ACOUS7ICAL CEILING TILE ARMSTRONG ROOM NAME SEATING AREA CONFERENCE ROOM SALES COUNTER KITCHEN/STORAGE HALL STORAGE WOMEN AIEN FLOORING T-2 T-2 T-2 T-2 T-2 CONCRETE T-1 T-1 � � � � � � � � � RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel , ��n„� �,.va�! DATE: 04��9�20 COLOR PATTERN rtEXTURE STEEL IRONWORKS GREY MATfE MQIAVE MIX WOODIAND MIDNIGHT BUCK -- RAVEN -- STERLING SILVER -- 40 BIACK MAN�AIAY 40 BIACK 4" COVE AMAZING GRAY EGGSHELL 7RICORN BIACK SEMIGLOSS BRAN�YWINE EGGSHELL MOUNT EfNA EGGSHELL BIACK KRYLON CHALKBOAR� 7RICORN BIACK EGGSHELL 7RICORN BIACK FIAT SEA BOTfOM DIAMANTE BIJZZARD DIAMANTE ROCKY MOUNTNN MOSAIC RECIAIMED WOOD PAP STEEL IRONWORKS CAPELLA RE� PORCEIAIN CAPELLA I MIX WOODIAND BIACK PEBBLE FINISH POLISHED CHROME HOPEWELL 5° STAIN ST-2 -- BIACK VELVEf 7RACELESS FINISH JEf BIACK -- SMOKEWOOD -- OAKWOOD -- EfCHED SILVER RIBFEST VERTICAL CALLA BIACK KITCHEN ZONE WHITE NUMBER E202�WM 22 45 78 MW—k%—H6 7044 6258 7710 7625 K05223000 6258 6258 L2—D1-04 L2—D1-01 NCAPRE�B R12%10 E2020WM P 807 M14848 15505-31 019A MW407 MW435 DWP4231 2822 67J REMARKS 12X24 TILE USE WITH GR-1 24X48 TILE USE WITH GR-2 20X20 TILE USE WITH GR-2 USE WITH T-1. W�-2 AN� YJ�-4 USE WITH r—z nNo r-3 USE WITH W�-3 ALL DOOR FRAMES AN� HOLLOW MEfAL �OORS ALL EXPOSED STRUCTURE, WALL ABOVE PAINT LINE � � � � PROVIDE BLACK GRID WASHABLE NORTHWALL EASTWALL SOl1THWALL WESTWALL CABINET51 CEILINGMAT/ REMARKS COUNTERTOPS HEIGHT � 3 P 6 P—fi/WC-1/ � �/��S PL-1/WP-1/ EHPOSE�/ OMIT BASE AT LOCATIONS WITH RT-3 wt—i/wr—a �e—i/ss—i P—� -- WC-1 WC-1 WC-1/W�-1 WC-1/W�-4 PL-1/ ACT-1 (P-7) FINISH ON OPERABLE PARTITION TO E 55-1 12-0 WC-1. COORDINATE WITH MANUFACTI __ �_3 P_6�_4 __ PL-1/ EHPOSE�/ __ 55-1 P-7 -- FRP-1 FRP-1 FRP-1 FRP-1 PL-1/ ACT-2/ __ SS-1 12-0 -- P-6/W�-1 P-6 P-6�W�-1 -- — IXPOSE�/ __ LE-1 P-7 -- P � P � P � P � — EHPOSE�/ __ -- UNFlNISHED -- W�-2�WC-2 W�-2�WC-2 W�-2�WC-2 W�-2�WC-2 — GYP B� (P-7) WqLL TILE IN RUNNING BOND PATTERI -- 9-0 W/ POL CHROME SCHLUTER STRIP A W�-2�WC-2 W�-2�WC-2 W�-2�WC-2 W�-2�WC-2 — GYP B� (P-7) WqLL TILE IN RUNNING BOND PATTERI -- o—n W/ POL CHROME SCHWiER STRIP A _q _q YKK YVS410 SINGLE HUNG WITHIN STOREFRONT ASSEMBLY SFI MARK iaoa 100B iaia 101B 101C 103A 103B 103C ID5 tos 107 ttPE FG F F F F SEE 3/A210 F F F F F 4' 1'h" *I- I � PI ❑ � � SFi SIZE 3-0 X 8-0 3-0 X 7-0 3-0 X 8-0 3-0 X 8-0 3-6 X 7-0 3-6 X 10-0 3-6 X 7-0 3-0 X 8-0 3-0 X 8-0 3-0 X B-0 3-0 X B-0 HARDWARE TYPES MATERIAL AWM INS. STEEL SCWD SCWD INS. STEEL SCWD INS. SiEEL SCWD SCWD SCWD SCWD FINISH BLACK ANOD P-2 PRERNISHED PRERNISHED P-2 STAMED P-2 PRERNISHED PRERNISHED PRERNISHED PRERNISHED RATING 90 MIN 90 MIN 90 MIN FRAME SF2 F2 sFa SF4 OH F2 F2 F1 F1 rt F1 MATERIAL AWM HOLLOW MEfAL AWM AWM HOLLOW MEfAL HOLLOW MEfAL HOLLOW MEfAL HOLLOW MEfAL HOLLOW MEfAL HOLLOW MEfAL TYPE FI RATING 90 MIN 9� MIN 9� MIN HOLLOW MEfALFRAME HARDWARE 01 02 oa oa O6 07 02 OS 08 03 03 TYPE F3 HOLLOW METALFRAME DOOR FRAME TYPES I NOTiOSULE SEE DOOR ISCHEDULE , �� V 0 0 TYPE F SEE DOOR SCH, EDUIE I � INSUL TEMPERED � CLEAR GIASS 'o V 0 o � o� TYpEFG DOOR TYPES Z NOT TO SCALE REMARKS -- 1 WNTINUOUS HINGE 1 KEYED EXIT DEVICE __ W/ VERTICAL PULL 1 PERIMEfER SFAL 1 THRESHOLD WIiH DRAINAGE SUBSILL 1 H.�. CLOSER -- 1 SWEEP FINISH: MATCH AOREFRONT �OOR TO MATCH EXIST. STORE YKK YVS410 SINGLE HUNG WITHIN STOREFRONT ASSEMBLY SF1 SF4 � SFS YKK YVS410 � aNr.iFuiiNr. STOREFRONT ELEVATIONS 3 IIq" = I' 0" FINISH BIACK ANOD P-2 BIACK ANOD BIACK ANOD P -2 P-2 P-2 PAINT PAINT PAINT 4 HINGES 1 PftIVACY LOCKSEf 3 MUTES 1 CLOSER 1 WALL STOP FINISH: TBD HARDWARE SET #OS 4 HINGES 1 PUSH/PULL 3 IAUTES 1 WALL STOP 1 CLOSER 1 KICK �OWN HOL� OPEN FINISH: TBD HARDWARE SET #0] 1 BARN �OOR TRACK FINISH: TBD HARDWARE SET #02 3 HINGES WITH N.R. PINS 1 KEYED E%IT �EVICE W/ EXi. LEVER HANDLE 1 PERIMEfER SFAL i THaESHo�o 1 H.D. CLOSER 1 SWEEP FlNISH: TBD HARDWARE SET #04 4 HINGES 2 VEftTICAL PULLS 1 PERIIAETER SEAL 1 CLOSER 1 KICK �OWN HOL� OPEN FlNISH: TBD HARDWARE SET t#16 3 HINGES WITH N.R. PINS 1 DEA�BOLT CYLIN�ER 1 PERIMETER SEAL 1 THRESHOLD 1 SWEEP FINISH: BUILDING STD. HARDWARE SET #OB 3 HWGES 1 OFFICE LICOKSET 3 IAUTES 1 WALL STOP FINISH: TBD DOORHARDWARENOTE "VERTICAL PULLS" ARE TO BE FORMS AND SURFACES DT1214 ROUND DOOR PULLS, U532 FINISH. LENGTH TO BE BO" AT 7-0 DOOR AND 92" AT B-0 DOORS. CENiER ON DOOR HEIGHT AND WIDTH OF STILE. GLAZING TYPES ALL GIAZING TO BE 1" INSUTATED GUSS AT E%TERIOR AND �" INSUTATED CUSS AT INTERIOR UNLESS NOTED OTHERWISE. T= SECTION OF GLAZING REWIRED TO BE TEMPERED — G1A55 — USE 1" INSUU+TED TEMPERED GLASS AT E%TERIOR APPLICATIONS, AND 3" TEIAPERED AT INTERIOR ���AT�QNS. 5= SECiION OF GLAZING TO BE TEMPERED INSUTATED GU+SS WITH SPANDREL FRIT ON SURFACE �4. IAATCH E%ISTING SPANDREL COLOR. IF THERE IS NO EXISTING SPANDREL GLASS, SUBMIT SAMPLE TO ARCHITECT FOR APPROVAL. GIASS MUS� MEEf THE FOLLOWING SPECIFICATIONS FOR COMPLIANCE WITH THE INDIANA ENERGY CONSERVATION CODE FOR ENVELOPE CALCUlATI0N5: LOW "E" COATING 'U" VALUE — MINIMUM OF 028 "SHGC' VALUE — MAXIMUM OF 0.47 � CURRAN uN�_ _��llRE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0661 F :: 317.288.0753 ,�,�,..:pt.,..._.,o.. _,92, N o. • ��: AR19600043 ! • n�h a . . THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEpTSCONTAINEDHEREINARE THE EXCLUSIVE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQURE AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUTTHE W0.ITTEN COMENT OF NRRAN ARCHITEQU0.E. � COPYRIGHi3019.NPRANAR6l1iE{IURE JAVA HOUSE COFFEE BAR 145 ELM STREET, SUITE 100 CARMEL, IN 46032 PERMIT SET 011B1�t0 CONSTRUQIONSEf 021�1�t0 �FINISHSCHEDULEREVISION O1.1510t0 190410 DOOR SCHEDULE AND FINISH PLAN A610 I 4'-Y'.l- I I 4'-Y".l- I I 4'-Y" �I- I ABBREVIATIONS A AM1IP.AMPERES AOA AMERIGANSWITH�ISABILRIE9AGT AFC ABOVEFlNISHEDCEILING AFF ABOVE Fl�ISHED FLOOR AFG ABOVEFl�ISHEDGRAOE AN51 AMERICANNATLSiANDAR�SINSTITUTE ARCH ARCHITECT.ARCHRECTURAL AU% AU%ILIARY AWG AMERICANWIREGAUGE AN AUDIONISUAL BAS BUILDINGAUTOMATIONSVSTEM BKR BREAKER BLOG BUIL�ING BMS BUILDINGMANAGEMENTSVSTEM C CONDUIT CAN CABLETELEVISIONSVSTEM GB CIRCUITBREAKER CCTV CLOSEDCIRCUIiTELEVIS10N CFM CUBICFEETPERMINUTE CKT CIRCUIT CLG CEILING CT CURRENTTRANSFORMER CW COL�WATER D DEEP,DEPTH �ACi DIGITALALARMCOMMUNICATINGTRANSMIiTER dB �ECIBEL �DC �IRECTDIGITALCONTROL 0 �ELTA DIA �IAMETER �ISC DISCONNECT oN oowN owc oenwmc EC ELECTRICALCONTRACTOR EF E%HAUSTFAN ETR EXISTWGTOREMAIN EMT ELECTRICALMETALLICTOBING EWC ELECTRICALWATERCOOLER EXH EXHAUST EX, EAIST EXISTWG FA FIREALARM FACP FIREALARMCONTROLPANEL FARA FlREALARMREMOTEANNUNCIATOR FLA FULLLOAOAMPS FPC FIREPROTECTIONWNTRACTOR FT FOOi FEET GGR� GROON� GC GENERALWNTRACTOR GFI.GFCI GROON�FAIILTINTERRIIPTER HI� HIGHIMENSRYDISCHARGE HTR HEATER HVAC HEATWG,VENTILATINGBNC IBC INTERNATIONALBVILDINGCO�E IN INCH, INCHES KVA KILOVOLT-AMPS KW KILOWATTS KWH KILOWATT-HOUR L LENGTH LED LIGHTEMITfINGDIODE LRA LOCKEDROTORAMPS LTG LIGHTING MA% MA%IMUM MC MECHANICALCONTRACTOR MCA MINIMOMCIRCUITAMPACITY MCB MAINCIRCUITBREAKER MCC MOTORCONTROLCENTER MECH MECHANICAL MH METAL HALIOE MIN MINIMOM MOCP MA%IMUMOVERCURRENTPROTECTION MUA MAKEIIPAIR MID MOUNTED NIA NOTAPPLICABLE N.G NORMALLVCLOSE� NEC NATIONALELECTRICALCODE NEMA NATIONALELECTRICALMFR'SASSOC. NFPA NATIONALFIREPROTECTIONASSOC. NIC NOTINCONTRACT N.O. NORMALLVOPEN NTS NOTTOSCALE OC ON CEMER OIH WERHEAD OSHA OCCUPATIONALSAFENBHEALTHADMIN. P POLE PB PUSH BUTTON PC PWMBINGCONTRACTOR PF POWERFACTOR PH PHASE PVC POL1'VINVLCHLORI�E RCP RERECTEDCEILIN6PLAN REV REVISION REX REMOVE EXISTING RGS RIGIDGALVAMZE�STEEL RLA RUNNINGLOADAMPS RM ROOM RR REMOVEANDRELOCATE RTO ROOFTOPUNIT SE SERVICE ENTRANCE SF S�UAREFEET,S�UAREFOOT TIC TIMECLOCK THRU THROUGH TRANS TRANSPoRMER TVP TYPICAL UG UNDERGROUN� UL UN�ERWRITERSLABORATOPoES,INC. UON UNLESSOTHERWISENOTEO OPS UNINTERRUPTE�POWERSOPPLY VA VOLT-AMPERE W WATT.WIDTH WI WITH WP WEATHERPROOF XFMR TRANSFORMER V WVE RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.T� DATE: 04�09�20 ELECTRICAL SYMBOLS FIRE ALARM SYMBOLS ALLSVMBOLSSHOWNARENOTNECESSARILVUSE�ONTHEORAWINGS ALLSVMBOLSSHOWNARENOTNECESSARILVIISE�ONTHE�RAWINGS 1 ) ( 1 1,3,5 HOMERUN TO PANEL'A" CIRCUIT N1 3 5 VIA 20A-0P CIRCOIT BREAKERS TWO i112 E FACP FIRE ALARM W NTROL PANEL � � 1 )� �A CON�UCTORS MINIMUMSIZE UON.AGROON�INGCON�OCTORSHALLBE ( ) E FAEP FIREALARM E%TENDER PANEL PROVI�E� IN ALL CON�OITS. REFER TO SPEQFICATIONS FOR AD�ITIONAL GROUNDING REQUIREMENTS. 6FAA FIREALARMANNUNCIATORPANEL ---- INFLOORIUN�ERFLOORCON�UITIWIRE 6FACU FlREALARMCONTROLUNIT QRCUITRY TURNING UP ❑F FlREALARMMANUALPOLLSTATIONMOUMEDAT48"AFF. G PANELBOARD�208VI120V�3ID-0W F FIREALARMBELLONLVALARMSIGNALWALLMOONTE�AT80"AFF. � � PANELBOARD�a80V127]V�30-0W � DRVTVPETRANSPoRMER,REFERTOPLANSFORSRENOLTAGE � FIREALARMBELLONLVALARMSIGNALCEILINGMOUNTED QJ �J JUNCTIONBOX�CEILINGORWALLMOUNTED. n� FlREALARMHORNONLVALARMSIGNALWALLMOUNTEDAT00"AFF. � DISWNNECTSWITCHONFUSED'."AS'-INDICATESSWITCHSIZE�AMPS). ✓LJ� FIREALARMHORNONLVALARMSIGNALCEILINGMOUNTE� � DISCONNECiSWITCHFU5E0: "AS'�INDICATESSWITCHSIZE(AMPS). �ry FlREALARMHORN/STROBEALARMSIGNALWALLMOUMEDATBO"AFF. "AF" � INDICATES FUSE SIZE (AMPS). �� FlREALARMHORN/STROBEALARMSIGNALCEILINGMOUMED & COMBINATIONMOTORSTARTERI�ISCONNECTSWIiCH � ijC FlREALARMVISUALONLVALARMSIGNALWALLMOUNTEDAT80'AFF. MOTOR � }� FIREALARMVISUALONLVALARMSIGNALCEILWGMOUNTED DUPLEX RECEPTACLE -125V, 20A, MOUMED AT iB" AFF UNLESS OTHERWISE NOTEO. � FlREALARMSPEAKERISTROBEALARMSIGNALWALLMOUME�AT80"AFF. m CONTROLLED DUPLEX RECEPTACLE � 125V, 20A. MOUNTED AT 18' AFF T( UNLESSOTHERWISENOTEO. �/ FlREALARMSPEAKERISTROBEALARMSIGNALCBLWGMOUME� � GFCIDUPLEX�125V,20A,MOUNTEDATIO'AFFUNLESSOTHERWISENOTED. � FIREALARMPHOTOELECTRICSMOKE�ETECTOR � �IIPLEXRECEPTACLEPROTECTEDVIAGFQBREAKER,PROVIOELABELING ASREpUIREDBVNEC-125V,20A,MOUNTEDATIB"AFFUNLESSOTHERWISE g FIREALARMDUCTMOUNTEDSMOKE�ETECTORWITHSAMPLINGTUBE, NOiED. FURNISHED AND WIREO BV EC. MOUMED BV MC. �p �UPLE%ABOVECOONTER-125V.20A,MOUNTEDATB'ABOVECOUNTER � REMOTEINDICATORLIGHTIAUDIBLEALARMFOR�UCTSMOKE�ETECTOR ll UNLESSOTHERWISENOTED. /� CONTROLLE��UPLEXRECEPTACLEABOVECOUNTER-125V,20A,MOUNTE� L".4 FIREALARMHEAT�ETECTOR-FlMTURETEMPERATURE � AT8"ABOVECOUNTERUNLESSOTHERWISENOiE�. ^ FlREALARMCARBONMONOXIDEDETECTOR p GFQDIIPLEXABOVECOUMER-125V.20A,MOUNTEDATB"ABOVE �' tl COUNTERUNLESSOiHERWISENOTED. � VALVE SUPERVISORY SWITCH �UPLE%ABOVE COUNTER PROTECTED VIA GFCI BREAKER PROVIOE � WATER FLOW DETECTOR SWITCH LABELMG AS R WUIRE� BY NEC -125V.20A MOUNTED AT 0" ABOVE � COIINTERUNLE550THERWISENOTE�. � KITCHENHOO�SOPPRESSIONSVSTEM � OOUBLE�IIPLEXRECEPTACLE-125V,20A,MOUNTE�AT18"AFFONLESS � FIREPUMPCONTROLPANEL OiHERWISE NOTED. � � �OORHOL�OPEN SPECIAL PURPOSE RECEPTACLE, iVPE AND MOUNTING AS INDICATE� ON THE oanwiNcs � ouP�exaecearnae-,zsv.zon,MounreowceiuNc FIREALARMNOTES � DUPLE%RECEPTACLE-125V,20A,MOUNTEDINCEILING. � OUPLEXRECEPTACLE-125V,20A,MOIINTE�INFLOORBO%. 1. PRINCIPALOCCUPANCVCLASSIFlCATIONISGROUPMORA. � DOUBLEDUPLEXRECEPTACLE-125V,20A,MOUMEDWFLOORBOX. Z, SPACEISPROVI�E�WRHFULLSPRWKLERCOVERAGE. � COMBINATIONDUPLEXRECEPTAQEANDVOICE/DATAOURETMOUMEDIN 3. OCCUPANTLOADISLESSTHAN500. FLOORBOX. 4. THELAN�LOR�DOESRE�OIREALLTENANTSTOINSTALLAFlREALARMSYSTEMMONITORED � FIRERATE�POKE-iHROUGHDEVICE�UPLE%RECEPTACLE-125V,20A. BVTHELAN�LOR�SVSTEM. .� COMBINATIONDUPLEXRECEPTACLEANDVOICEIDATAPONETHROOGHOEVICE 5. AFlREALARMSYSTEMISREQUIRED. �UPLEX RECEPTACLE. RANGERECEPTACLE.REFERTOPLANSFORiYPEAN�AMPERAGE. fi. AIRHAN�LINGSVSTEMSWITHANAGGREGATECAPACITVOVER2,OOOCFMREQUIRE�UCT � SMOKE DETECTORS WITH LOCAL VISIBLE AND AUDIBLE SUPERVISORY SIGNAL MOUNTE� IN AN � POWERPOLE,REFERTOPLANSFORTVPEAN�AMPERAGE APPROVEDLOCATION.DUCTSMOKEDETECTORMONITORWGSHALLBEBYOTHERSUNDER � SEPARATE CONTRACT WITH THE OWNER. SWITCH - SINGLE POLE TOGGLE TYPE-12012]]V, 20A,1-HP RATEO. MOUNTED AT a8"AFFUNLESSOTHERWISENOTED. ]. FIREALARMSYSTEMINSTALLEDORMODIFIEOBVTHISCONTRACTORISTOBEVERIFIE�ANO "3" IN�ICATES THREE WAY SWITCH CERTIFlE� BY AHJ AT THIS CONTRACTOR'S EXPENSE. .�.',No�ATEssw,T� Mo N'TEoe�ABa�E�o�NTER FIRE ALARM SPECIFICATIONS "a" INDICATES SWITCHED FI%TURE CONTROL "OS"INDICATESDUALTECHNOLOGVOCCUPANCVSENSORSWITCH 1. ACOMPLETEEXTENSIONOFTHELANDLOR�FIREALARMSYSTEMSHALLBEPROVI�EDAS "D"INDICATESDIMMERSWIiCH�WAiTAGEA5INDICATEDONPANEL DESCRIBE�ONTHE�RAWINGS.ALLDEVICES,WIRING.BACKBOXES.PROGRAMMING, SCHEDULE.EACHBRANCHCIRCUITSHALLWCLUDEASEPARATE START-UP.WSTROCTIONANOTESTINGREp01REDFORACOMPLETEOPERATING5V5TEM NEUTRAL CONDUCTOR SHALL BE PROVIDED. � OCCUPANCVSENSOR-0UALTECHNOLOGY,CEILINGMOUNTE� 2, THEELECTRICALCONTRACTORSHALLFURNISHSHOPDRAWINGS,COMPLETEWITH W UIPMENT GUTS AND FLOOR PLANS (WITH WIRIN6IN�ICATE�J, AS WELL AS BATTERY � PHOTOCELLSENSOR�DUALTECHNOLOGY,CEILMGMOUNTED CALCOlATI0N5,AN�VOLTAGE�ROPCALWLATI0N5FORREVIEWANDAPPROVALBVTHE ARCHITECi, ENGWEER, AND ALL AUTHORITIES HAVING JURIS�ICTION. FLOOR PLAN �13 LIGHTFlMTURP."A'INDICATESFlXTUREiYPE,"13'INDICATESCIRCUITNUMBER,"a' DRAWINGSSHALLBESTAMPEDBYAPROFESSIONALENGWEERRETAINEOBYTHE a INDICATESSWITCHCONTROL.REFERTOLUMINAIRESCHEDULEPoRDESCRIPTION. CONTRACTORANDIORSUPPLIER.NICET4CERTIFlCATIONANDSTAMPISACCEPTABLE,IF A APPROVEO BV THE AUTHORITY HAVING JURISDICTION. 3. THEELECTRICALCONTRACTORSHALLFURNISHFIREALARM�RAWINGS,CALCUUITIONS,AN� � NL LIGHTINGFI%TOREWIREDTOEMERGENCYANDIORNIGHTLIGHTWGCKi. EpUIPMENTINFORMATIONFORALLREQUIRE�LOCALMUNICIPALIiV,ORSTATEPERMITS.THE ELECTRICAL CONTRACTOR SHALL ARRANGE AND COORDINATE ALL REQUIREO TESTMG AND ��.p ILWMINATED"E%IT"SIGN,OUALHEADS.CEILINGMOONTE�ISUSPENDE�.PROVI�E INSPECTIONSREDUIREDBVTHELOCALMUNICIPALITVFIREDEPARTMENT.THEELECTRICAL lbl DIRECTIONALARROWSASINDICATEDONFLOORPLANS. CONTRACTORSHALLWCLUDEFIREOEPARTMENTCOSTSINBI�. 4. ALLHVACUNITSORGROUPOFHVACUNITSWITHACOMMONPLENUMAN�A�ESIGN CG REMOTEEMERGENCVWEATHERPROOFLIGHTINGHEADSUPPLIEDFROMREMOTE CAPACITVGREATERTHAN2000CFMSHALLAUTOMATICALLYSHUTDOWNASSOCIATEDHVAC �Ip BATTERVUNIT. UNITORUNITS.WHEREAOUCTSMOKE�ETECTORISNOTVISIBLEORACCESSIBLEFROMTHE p EMERGENCVLIGHTINGBATTERVUNITWITHHEADSASINDICATEO.CEILINGOR FLOOR,REMOTEAUDIBLENISUALALARMIN�ICATORRESTSWITCHESSHALLBEPROVIDEDIN �� WALLMOUNTED. ANAPPROVE�LOCATION,ATAHEIGHTACCESSIBLEANDVISIBLEFROMTHEFLOOR.HVAC DUCT DEiECTORS SHALL BE CONNECTED TO A CENTRAL STATION MONITORING SYSTEM Q TIMECLOCK�REFERTOPLANSPoRSPEqFlCATI0N5. UNDERSEPARATECONTftACTWITHTHEOWNER. 5 FlREALARMSIGNALSHALLINITIATETHEFOLLOWINGACTIONS: C LCP LIGHTINGCONTROLPANEL-REFERTOPLANSFORSPEQFlCATIONS. a. WNTINUOUSLYOPERATEALARMNOTIRCATIONAPPLIANCES. b. I�ENTIFY ALARM AND SPEQFIC INITIATION �EVICE AT FIRE CONTROL PANEL. �B �OORBELLREFERTOPLANSFORSPECIFICATIONS. c. TRANSMITALARMTOLANDLORDSVSTEM. tl. TRANSMITALARMSIGNALTOREMOTERECBVINGSTATION. Q �OORBELLPUSHBIITTON-REFERTOPLANSFORSPECIFICATIONS. e. IMERRUPTTENANTSOUNDSVSTEM. C SHUT�OWNAIRHANDLINGSVSTEMS. O THERMOSTAT-PROVI�ESINGLEGANGBOXWITHPLASTERRINGAN�3/4" 6. ALLFIREALARMVISIBLEDEVICESSHALLBEADACOMPLIAM.SiROBEINTEN51TIE5A5 /�',� CON�UIT TO ABOVE THE ACCESSIBLE CEILING. DELEGATED �ESIGN BV SVSTEM VENoOR. CEILING MOUNTEO DEVICES SHALL HAVE A RATING � JUNCTIONBO%AN��ISCONNECTSWITCHFORSIGNAGE WITHTHELISTEDRE�UIREMENTSFORASPEqFlCCEILINGHBGHT. ]. ALLWALLMOUNTE�STROBES,SPEAKER-STROBES,ORHORNSTROBESSHALLBEMOUNTE� � COMBINATIONVOICEIDATAOUTLET-MOUNTEDATIB"AFFONLESSOTHERWISE SUCHTHATTHELENSISNOTLESSTHANBOINCHESAN�NOTMORETHAN961NCHESABOVE NOTE�.PROVI�ESINGLEGANGBOXWITHPLASTERRINGAN�3/4"WNDUITTO THEFINISHEDFLOOR. ABOVETHEACCE5518LECEILING.'i56"INDICATESWALLMOUNTEDAT56"AFF,'C" g. ALLAUDIBLENOTIFICATIONAPPLIANCESSHALLBESETTOACHIEVEASOUN�PRESSUREAT INDICATES MOUNTE� 8" ABOVE COUNTER. LEAST iStlB A90VE THE AVERAGE AMBIENT SOUND LEVEL. Q �ATAOOTLET-MOlIME0AT18"AFFUNLESSOTHERWISENOTED.PROVI�E 9� ALLCABLESFORTHEFIREALARMSYSTEMSHALLBERATE�FORTHEINTEN�E�USE. SINGLEGANG80%WITHPIASTERRINGAND3/4"CONOOITTOABOVETHE 1�. FIREALARMSVSTEMMONITORINGSHALLBEBVOTHERSl1N�ER5EPARATECONTRACTWITH ACCESSIBLECEILING."+Sa'INOICATESWALLMOUMEDAT5a'AFF,"C'INOICATES THEOWNER. MOUMEDB"ABOVECOUMER. it PROVIDEASEPARATELINEITEMCOSTFORA�IJ,�3),(5)YEARMAINiENANCETESTWGAND - VOICEOOTLET-MOl1NTE�AT18"AFFIINLESSOTHERWISENOTE�.PROVI�E MONITORINGAGREEMENT.AGREEMENTTOINCLUDEMONITORINGTOAULLISTEOCENTRAL SINGLEGANG80%WITHPIASTERRINGAND3/6"CONOUITTOABOVETHE STATIONPERNFPAI2REQUIREMENTS,ALLCOOEREOl11RE�TESTINGOFTHEFIREALARM ACCESSIBLECEILING."+SJ"INOICATESWALLMOUNTE�AT54'AFF,"C"IN�ICATES SVSTEMPERNFPA]2AN�OBC(MONTHLVVISUALINSPECTIONSHALLBEBYTHEOWNER), MOUMED B" ABOVE COUMER. CLEANING OF DEVICES SHALL 8E DONE UPON SYSTEM REp0E5T, ANO ALL COST ASSOCIATEO WITH MAIMENANCE OF THE SVSTEM SHALL BE PROVIDE� (�VE TO �EFECTNE EQUIPMENT 4 NOUTLET-MOOME�AT18"AFFUNLESSOTHERW6ENOTE� PROVI�ESINGLE ONLY�PROVI�EAVEARLVREPORTTOTHEOWNER. GANGBOXWITHPLASTERRINGAN�3/4"CONOUITTOABOVETHEACCESSIBLE �p, FIREALARMSYSTEMSHALLMATCHTHELANDLOR�SVSTEM. CEILWG. "�5a' INDICATES WALL MOUNTED Ai 54" AFF, "C INDICATES MOUNTE� 8" ABOVE COUMER. �a SECURITVCAMERA-PROVIDESINGLEGANGBOXWITHPLASTERRWGAND314" WNDUIT TO ABOVE THE ACCESSIBLE CEILING. � WIRELESSACCESSPOINT ELECTRICAL SPECIFICATIONS DIVISION 26 - ELECTRICAL I. GENER4LPROVISIONS A. GENERALCONDITIONS CODE585TAN�ARDS 1. GENERALCONOITIONSOFTHECONTRACTFOUNDINTHEARCHITECTUftAL �RAWINGS, GENERAL AN� SPECIAL WNDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) AND ANV OF THE OWNER'S GENERAL REOl11REMENTS SHALL APPLY UNLE55 NOTE� OTHERWISE. 2. REFERTOTHEGENERALCON�ITIONSONTHEARCHITECTURALDOCUNENTS AND THE GENERAL AND SPEqAL CONDITIONS OF THE AIA PoR ADDITIONAL RE�UIREMENTS REGARDING� SAFETV COORDINATION 8 COOPERATION WORKMANSHIP,PROTECTION WTTINGANDPATCHING �AMAGETOOTHER WORK, PRELIMINARV OPERATIONS. STORAGE, ADJUSTMENTS, CLEANING, ETC 3. ALLWORKSHALLBEINCONPoRMANCEWITHALLLOCALLYENFORCED, FEDERAL, STATE, AND LOCAL CO�ES AN� ORDINANCES INCLUDING ANV SPEQAL THE OWNER REQUIREMENTS IN AD�ITION TO THOSE SPEQFIE�. G. CONTRACTORSHALLPAYFORANDOBTAINALLNECESSARYLICENSES, PERMIiS AND INSPECTIONS REpUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLU�E ALL REQUIRE� COORDINATION WITH THE LOCAL UTILITV WMPAWES AND THEIR ASSOCIATED FEES OR WSTS. 5. ALLEOl11PMENTAN�MATERIAL5U5E�SHALLBENEWAN�ULLISTE�FOR THE APPLICATION, AN� SHALL BEAR AN APPROPRIATE lIL LABEL. B. SCOPEOFWORK 1. THISCONTRACTSHALLINCLUDETHEFURNISHING,INSTALLING,CONNECTING AN� OPERATION OF ALL EOl11PMENT WHICH IS A PART OF THE ELECTRICAL SVSTEMS AS SHOWN ON THE �RAWINGS AN� AS REQUIRE� BY SIMILAR WSTALLATIONS. ANV MATERIAL OR LABOR 6VHICH IS NEITHER SHOWN ON THE DRAWWGS NOR CALLED FOR IN THE SPEQFlCATIONS. eUi WHICH IS OBVIOUSLY NECESSARV TO COMPLETE THE WORK AND WHICH IS USUALLV INCLUDEO IN WORN OF A SIMILAR CHARACTER SHALL BE FURNISHEO ANO INSTALLED UNDER THIS CONTRACT AT NO AD�ITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVI�E ALL LABOR AND MATERIALS REpUIRED TO PROVIDE THE OWNER A COMPLETE, COOE APPROVED AND OPERATIONAL ELECTRICALSVSTEM. 2. CAREFIILLVRFA�SPECIFICATIONFORALLPART50FTHEWORK50A5T0 BECOMEFAMILIARWITHALLTRA�ES'WORKSCOPE. CONSOLTWITHOTHER TRADESTOINSUREPROPERLOCATIONSANOAVOIOINTERFERENCES. ANV WNFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEPoRE WORKISCOMMENCED. 3. CONTRACTORSSHALLBEHELOTOHAVEEXAMWEDTHEPREMISESANOSITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPEQFICAiIONS. NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE RE�UIRED, ANO THE NATURE OF THE CONOITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NOALLOWANCESHALLBEMA�ETOTHECONTRACTORBY RFASON OF THIS FAI W RE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALLE%ISTINGUTILITVANDELECTRICALSERNCESSHALLBEFIELOVERIFIED. CORRECTIONS TO THE DESIGN AN� INSTALLATION SHALL BE MADE WITHOUT ADOITIONAL W ST TO THE OWNER. 5. PROVI�EALLCUTTMGANDPATCHINGREpUIREDFORINSTALLATIONOF ELECTRICALWORK. ALLCOREDRILLINGORCUTfINGOFFIRERATED FLOORS, SHARS, AND WALLS SHALL BE FlRESTOPPED PRIOR TO FlNISH PATCHING. ALL PENETRATIONS SHALL BE FlRE SEALED TO MATCH THE FlRE RATING OF THE FLOORS. SHAFTS, ANO WALLS PENETRATED. 6. TEMPORARVELECTRICALSERVICELIGHTING,AN�RELATEDWIRINGSHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRAOES �URING CONSTRUCTION. ]. TEMPERATUREANDINTERLOCKCONTROLCOMPONENTSANDALLRELATED WIRING AND CON�WT SHALL BE PROVIDEO BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. e. ALLWORKINCLUDINGBUTNOTLIMITEDTOPARTS,MATERIAL,E�UIPMENT AN� LABOR SHALL BE GUARAMEED FOR ONE VEAR AFTER ACCEPTANCE BY THEENGINEERAN�OWNER. WHEREANEQUIPMENTMANUFACNRERHASA WARRANTV THAT EXCEE�S ONE VFAR, THAT WARRANTY PERIO� SHALL APPLV TO THIS PROJECT. C. DOCUMENTS 1. THEDRAWINGSAREDIAGRAMMATIC'.ALLWORNSHALLBEPERFORME�AS IN�ICATE� ON THE �RAWINGS UNLE55 EXISTING CONDRIONS OR COOR�INATION ISSOES REpUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL WST i0 THE OWNER. 2. ANVINCIDENTALREMSORLABORETC.NOTINCLUOEDINTHE SPEQFICATIONS OR THE �RAWINGS BUT REASONABLV IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATOS SHALL BE INCWOING IN BI�. 3. THEORAWINGSANDSPEQFlCAT10NSAREIMENDEDTOSUPPLEMENTEACH OTHER AN� ANY MATERIAL OR LABOR CALLED FOR W �NE SHALL BE FIIRNISHED EVEV THOUGH NOT MENTIONE� IN BOTH. 4. IF ERRORS ARE FOUN� IN THE DRAWINGS OR SPECIFICATIONS, OR DISCREPANqES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRPWINGS AND THE SCALE OF SAME.OR BETWEEN THE LAR6ER AN� SMALLER ORAWIN6S, OR IN THE DESCRIPTNE MATTER ON THE ORAWIN6S, SUCH ERRORS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FINAL DEQSION PRIOR TO THE BID OUE OATE. 5. THEBI��WGOFTHISWORKWILLCOMEMPLATETHEUSEOFEQUIPMENT AND MATERIALS EXACTLV AS SPEqFlED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANV ONE MAY BE IITILIZED. SUBSTITOTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL ANO MUST BE SUBMITTED AS SPEqFIED IN THE ARCHITECTURAL �OCUMENTS. 6. MISCELLANEOUSITEMSNECESSARYTOCOMPLETETHESYSTEMSCANBEOF ANV RECOGNIZED MANUFACTORE PROVIOE� THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REpUIREMENTS. �. COOR�INATION 1. WNTRACTORSHALLLOCATEIOENTIFYANDPROTECTANVEXISTING SERVICES WHICH ARE REpUIRE� TO BE MAINTAMED OPERATIONAL AN� SHALL E%ERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF �AMAGES TO SUCH SERVICES SHALL BE PAID BV THE CONTRACTOR CAUSING THE �AMAGE. 2. EACHCONTRACTORSHALLBEHEL�RESPONSIBLEFORALLOAMAGETO OTHER WORK CAIISE� BY HIS WORK OR THROOGH THE NEGLECT OF HIS, OR HIS SUB�TRADE'S PERSONNEL ALL PATCHING. REPAIRING REPIACEMENT AN� PAINTING, ETG SHALL BE �ONE AS DIRECTE� BV THE OWNER BV THE CRAFTSMEN OF THE TRADES INVOLVE�. THE COSTS OF SUCH WORK SHALL BE PAI� BV THE CONTRACTOR CAUSING THE �AMAGE. 3. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT 8E DONE AT SUCH iIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE OPERATIONS OF THE SPACE, ADJACENT SPACES. OR FAQLIN. A WORK SCHE�ULE SHALL BE ARRANGED WITH THE OWNER, INCLUDING PREMWM TIME WORK TO FACILRATE WORK WITH A MINIMUM OF INTERFERENCE TO THE OWNER'S OPERATIONS. E METH0�5 L EQUIPMENT,WN�UILEfGSHALLNOTBESUPPORTEDFROMANVCEILINGS, OTHER PIPING, OTHER CON�l11T OR �OCTWORK. ROOF �ECK.OR JOIST BRI�GING. ITEMS SHALL BE SOPPORTE� FROM ACCEPTABLE STRUCTIIRAL BUILOING COMPONENTS AS DETERMWED BY THE ARCHITECi AND STRUCTURALENGWEER. 2. ALLROOFPENETRATIONS,FLASHINGSANDCOUMERFLASHINGSSHALLBE PERFORMED BV THE OWNER'S ROOFING WNTRACTOR AT THE REOl1ESTING CONTRACTORS COST. F. SUBMITTALS 1. SHOPDRAWINGSSHALLBEPROVIDEOTOiHEARCHITECiOFALLEQUIPMENT AND ACCESSORIES PROVIDED FOR THE PROJECT WHETHER SPEQFlEO HERE-IN OR ON THE DRAWINGS. REVIEW OF THE SHOP �RAWINGS SHALL BE FOR GENERAL �ESIGN CONCEPT AN� A�HERENCE WITH THE SPECIFICATIONS. QUANTITY OF SHOP �RAWINGS SUBMITTED SHALL 8E AS SPEqFIEDBYTHEARCHITECT. SHOPDRAWINGSSHALLBEPREPAREDBV THE W NTRACTOR SHOWING LOCATIONS AND MEASUREMENTS FROM WLUMNS OF ALL CONCEALE� AN� EXPOSED PIPING. �UCTWORK, CON�UIT. EpUIPMENT, ACCESSORIES, ETC., AND SUBMITTE� PRIOR TO INSTALLATION. THE OWNER MAY MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILAeLE PoR USE IN PREPARATION OF $HOP DRAWINGS, HOWEVERTHE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFlRMIN6 ALL WFORMATION ON THE �RAWINGS PRIOR TO FABRICATION ANDIOR INSTALLATION. 2. PROJECTRECORDDOCUMENTS-MAINTAINATTHEJOBSITEONECOPVOF ALL CONTRACT OOCUMENTS CLEARLV MARKED AS'PROJECT RECORD COPV". THESE �RAWINGS ARE TO BE MAINTAMEO IN G00� CON�ITION. UPDATED DAILY FOR CHANGES ENCOUMERE� AN� AVAILABLE AT ALL TIMES FOR INSPECTIONBVTHEOWNER. DONOTUSEFORFIELDCONSTROCTION! PROJECT RECORD DOCUMENTS ARE i0 8E KEPT CURRENT WITH E%ACT oIMEN510NS OF ALL WORK. E�UIPMENT, �ISTRIBUTION CONDUIT. CIRCUITS, ETG MARKALLINFORMATIONINRE�LWESANDNOTESSOASTOBEFASILY IDENTIFlE�FROMTHEBASEDRAWING. UPONCOMPLETIONOFTHEWORK. ONE SET OF THESE OOCUMEMS SHALL BE TURNE� OVER TO THE OWNER AS ONE QUAUFlCATION FOR FINAL PAVMENT. 3. THREECOMPLETESETSOFAS-BUILTDOCUMENTATIONSHALLBEPROVIDE�. R SHALL INCLO�E, BUT NOT BE LIMITE� TO ACCURATE PLAN �RAWINGS, WIRING �IAGRAMS AN� OPERATION AND MAMTENANCE MANUALS. 4. SUBMITOVERCURRENTDEVICECOORDINATIONSTUDVWCLUDING EQUIPMEM EVALUATION REPORTS, ONE LME DIAGRAM, PROTECTNE DEVICE WOR�INATION STUDVANDTIME CURRENT WOR�INATION CORVES. STUDV ELECTRICAL DISTRIBlITION SVSTEM FROM NORMAL AN� ALTERNATE POWER SOURCES. THE STU�Y SHALL COMPLY WITH IEEE 399 FOR GENERAL SiU�Y RE�UIREMENTS. II. PRODUCTS A. CONDUIT 1. WNDUITSHALLBEHEAWWALLRIGI�GALVANIZE�STEELWHEREEXPOSED AN� Sl1BJECT TO �AMAGE, 8'�0" AFF AND BELOW, AN� IN WET LOCATIONS WHERE INOICATED ON THE ORAWINGS. INTERIOR CON�UITS SHALL BE ELECTRICALMEiALLICTUBING EMT.METALCIAD MC CABLEMAVBEUSEO ( 1 ( 1 IF APPROVED BV THE OWNER AND INSTALLE� IN LOCATIONS PERMITfED BY CO�E. 2. FLE%IBLEMETALCON�IIITSHALLBEOSE�FROMOUTLETBO%TOIN�IVI�UAL RECESSED LIGHT FI%iURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION. B. WNDUITFlTTWGSANDBO%ES 1. INTERIOR OIITLET BOXES SHALL BE STAN�ARD GALVANIZE� SHEET STEEL TYPE, NOT LESS THAN 1G GAUGE IN THICKNESS, WITH KNOCKOOT OPENINGS, EXTENSIONS, PLASTER RMGS AND COVER PLATES TO ACCOMM1IODATE THE DEVICES INSTALLE�. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH �EVICE COLOR. USE STEEL PLATES WITH ROUNOED CORNERS FOR SURFACE BO%E5. OOTDOOR (WET LOCATION) Ol1TLET BOXES SHALL BE CAST AW MINUM NPE WRH DEVICE COVERS TO SUIT. 2. OUTLET BO%ES SHALL NOT BE LESS THAN 61NCHE5 S�UARE,1-V2 WCHES DEEP. 3. COUPLINGSAN�CONNECTORSPoREMTSHALLBEDIECASTZINCORSTEEL. BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. 4. FLOORBOXESSHALLBEFWSHSERVICETYPE.,RECTANGULARCASTMETAL CONSTRUCTION GANGABLE ADJUSTABLE WITH 8RA55 (ALUMINUM� COVER AND TRIMIFLANGE AS RE�UIRED. COVER NPE SHALL BE AS INOICATED ON LEGEND. G WIREANDCABLE 1. CON�UCTORSFORPOWERAN�LIGHTINGSHALLBENEW6W-VOLT,90°C, TYPE %HHW, THHW, OR THWN INSULATION, MINIMOM SIZE #12AWG. EXCEPT FOR CONTROL WIRING WHICH MAV BE N14 AWG OTHER SIZES SHALL BE AS NOTED ON THE ORAWINGS. CONDUCTORS SHALL BE COPPER, UNLE55 OTHER4VISE APPROVE� BV THE OWNER. 2 BRANCHCIRCOITRONSE%CEE�WG100FEETINTOTALLENGiHFROMTHE PANELBOARD TO THE LAST DEVICE. SHALL BE #10-AWG CONDUCTORS UNLESSOTHERWISE NOTED. 3. COMPRESSIONTYPEWGSANDCONNECTORSSHALLBEUSEDPoRALL TERMINATIONS AN� SPLICES. G. ALLLOWVOLTAGECOMMUNICATIONS,FIREALARM,DATA.SECURITV. TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CBLING SHALL BE PLENUM RATED. D. WIRINGDEVICES 1. DUPLEXRECEPTACLESSHALLBEGROUNDINGNPE,NEMA520R,RATEDFOR 20 AMPS, 125 VOLTS, WIiH PROVISIONS FOR BACK AND SIDE WIRING. 2. CONTROLLEDRECEPTACLESSHALLBEPROVIDEDWITHIDENTIRABLE MARKINGS. 3. SWITCHESSHALLBETOGGLEOPERATED,QOIETNPE.RATE�FOR20AMP5, 12012]] VOLTS, WRH PROVISIONS FOR BACK AN� SI�E WIRING. THREE WAV AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 4. DIMMERSSHALLBELUTRON"NOVAT-STAR"SERIES,OFARATING.VOLTAGE AN� WATTAGE SOITABLE FOR LOAD SERVED. 5. COLORSOF�EVICESSHALLBESELECTEOBYARCHITECT. 6. WIRINGDEVICESSHALLBESPECIFICATIONGRADE,ASMANUFACTORE�BY HUBBELL, PASS 8 SEYMOl1R. ARROW HART, LEVITON AN� GENERAL ELECTRIC E LIGHTING ANO RECEPTACLE PANELBOARDS 1. BRANCHQRCORPANELBOAR�SSHALLBE�EADFRONTNPE.WITHMAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A SURFACE OR FW SH MOUMED SHEET STEEL ENCLOSURE MINIMUM SHORT QRW IT CAPACIN SHALL BE 10,000 AMPS SVMMETRICAL FOR 120/208V, AN� 18 000 AMPS SYMMETRICAL FOR 2]]I480V APPLICATION ONLE55 NOTEO OTHERWISE. 2. ELECTRICALPANELSMOUNTEDONINTERIOROFBUILDINGSHALLBENEMAI TVPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 3. QRWITBREANERSSHALLBEBOLTONTYPE:WITHMOLDE�PLASTICCASE;1. 2, OR 3 POLE AS INDICATED', pWCK�MAKE. pUICK-BREAK', AND THERMALMAGNETIC TRIP �EVICE. 4. ALLBREAKERSFEEDWGHVACE�UIPMENTSHALLBEHACRRATED,UNLESS OTHERWISE NOTE�. 5. ALLEOIIIPMENTRATE�100AORLESSSHALLHAVE60�EGREECMINIMUM TERMINATIONS. ALL EpUIPMENT RATED OVER 100A SHALL HAVE ]5 �EGREE A41NIMlIM11TERMINAT10N$. 8. IM1DIVIDUAL SINGLE POLE QRCUIT BREAKERS, WITH IDENTIFlED TIES OR 2/3 POLEBREANERSSHALLBEPROVIOEDFOREACHUN6ROUNDE�CON�UCTOR IN ALL MULTI WIRE BRANCH QRCWTS. ]. PANEL80AR�SSHALLBEASMANUFACTUREDBYS�UARE�.GENERAL ELECTRIQ SIEMENS, AND EATON. F. SAFETVSWITCHESANDMOTORSTARTERS 6. SAFETVSWIiCHE55HALLBEFUSIBLEORNON�FU518LEASIN0ICATEDONTHE DRAWIN6S. SWITCHES SHALL BE �WCK-MAKE. �UICK-BREAK, HEAVY �UN VISIBLE BLA�E TYPE. ENCLOSURES SHALL BE RATED FOR INSTALLATION IN �ESIGNATE� AREA AS INDICATED ON PLANS. INTERIOR ENCLOSURES SHALL BE NEMA 1 TVPE UNLESS OTHERWISE INDICATEO ON THE DRAWINGS. EXTERIOR ENCLOSURES SHALL BE NEMA 3R TVPE UNLESS OTHERWISE INDICATED ON THE �RAWINGS FUSES SHALL BE DUAL ELEMENT-TIME �ELAY TYPE. ]. MAGNETICMOTORSTARTERSSHALLBECOMBINATIONTVPEWITHTHERMAL OVERLOAD. INTEGRAL FOSE� SAFETY SWITCH, H-O-A SELECTOR SWITCH, CONTROL TRANSFORMER, RUNNING PILOT LIGHT, NEMA TYPE 1 ENCLOSURE, AND (2) NORMALLV OPEN AND (2) NORMALLY CLOSED AU%ILIARV CONTACTS. 8. ALLMOTORSOVER118HPSHALLBEPROVI�E�WITHTHERMALOVERLOAO PROTECTION.OVERLOAD PROTECTION SHALL BE PROVIOE� INTEGRAL WITH THE MOTOR WINOINGS AND/OR MOTOR CONTROLLER (PROVIDE� BV OTHERS) UNLESS OTHERWISE INDICATE� ON DRAWINGS. 9. ALLE�UIPMENTRATEOt00A0RLESSSHALLHAVE60DEGREECMINIMUM TERMINATIONS. ALL E�UIPMENT RATED OVER 100A SHALL HAVE ]5 DEGREE MINIMUM TERMINATIONS. G WMINAIRESANDLAMPS 1. ALLLUMINAIRESSHALLBESPECIREDONTHELUMINAIRESCHE�ULE. 2. BALLASTSSHALLBEINSTANTSTART.ELECTRONICiYPECLASSP,"A'SOUND RATING AN� MAXIMUM HARMONIC COMENT OF 10%. �IMMING BALLASTS SHALL BE 3 WIRE TYPE, WITH �IMMING CAPABILITY T010%OF RATE� FULL OUTPUT. 3. RECESSEDLUMINAIRESWITHINCANOESCENTLAMPSSHALL9EPROVIDE� WITH THERMAL PROTECTION. 4. FLUORESCENTLAMPSSHALLBE3500K.INCANDESCENTLAMPSSHALLBE130 VOLT. HIGH INTENSIN DISCHARGE LAMPS SHALL BE COATEO. 5. EMERGENCVLIGHTINGASINDICATED,SHALLPROVIDEAMINIMUMOFONE FOOTCANDLE ALONG THE PATH OF EGRESS. EMERGENCV FlMTURE SUPPLIER SHALL PROVIDE FOOTCANDLE PRINTOUT TO VERIFY EMERGENCV LIGHT LEVELS. 6. ALLFI%TURE/BALLAST/LAMPCOMBINATIONSSHALLBEENERGYSAVING TVPE. III. EXECUTION A. GENERALMISCELLANEOUS 1. ALLCONDWiRONINFINISHEDAREA55HALLBECONCEALED.CONDUIT SMALLER THAN 3/4" SHALL NOT BE USED FOR ANV qRCUIT HOMERUNS. 2. RACEWAVSE%POSEDTODIFFERENTTEMPERATURESSHALLBEFlLLEOWITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300] OF THE NATIONAL ELECTRICAL CO�E. 3. HANGERS,SOPPORTS,ORFASTENINGSSHALLBEPROVIDEDATEACHELBOW, AT THE ENOS OF STRAIGHT RUNS TERMINATMG AT BO%ES OR CABWETS, AN� AT IMERME�IATE POINTS AS R WUIRE� BY CO�E CON�UITS OR BOXES SHALL NOT BE SOPPORTED BV CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. ACCESSPANELSSHALLBEPROVIDE�FORALUUNCTIONBO%ESAN�PULL BO%ES INSTALLED ABOVE DRYWALL CEILINGS, COORDINATE SIZE AND LOCATION WITH ARCHITECT. 5. FI%iURESUPPORTSSHALLBEINACCOR�ANCEWITHARTICLE410300FTHE NATIONAL ELECTRICAL CO�E, OR ANV LOCAL CO�ES WHICH MY APPLY. 6. PROVIDEPERMANENTNAMEPLATESWITHOESIGNATIONSFOR PANELBOAR�S, FEE�ER DEVICES, DISTRIBUTION E�UIPMENT AN� STARTERS. ]. PROVI�EiYPEWRITfEN�IRECTORYCAR�SWITHBRANCHCIRWIT I�ENTIFICATION FOR BRANCH QRCOR PANELBOAR�S. PANELBOAR�S, FEEOER OEVICES, DISiRIBl1TI0N EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN pUALIRED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 8. INSTALL HANDLE GUAR�S ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCV AN� SIMILAR CIRCl11TS. 9. THEELECTRICALCONTRACTORSHALLBALANCEPANELBOARDLOADWGTO WITHIN 10%ON EACH PHASE BASED ON INSTALLE� CONDITIONS. LOA� BALANCING qRW IT CHAN6ES SHALL BE PERFORMED OUTSIDE THE NORMAL OCCUPANCY WORKING SCHEDULE AN� AT A TIME OIRECTEO BY LANOLORD. 10. THEFINALLOCATIONSOFALLEpUIPMENi,OUTLETS,ETC.SHALLBESUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHWG-IN, AT NO ADDITIONAL COST TO THE OWNER. it. CONTACTELECTRICPOWERCOMPANVANDMAKENECESSARY ARRANGEMENTS FOR ELEQRIC SERVICE. 12 CONTACTTELEPHONECOMPANVANOMAKENECESSARVARRANGEMENTS FOR TELEPHONE SERVICE. 13. ATALLTIMESKEEPPREMISESANDBUILDINGINANEATAN�ORDERLY CONDITION. FOLLOWING OWNER'S INSTRUCTION IN REGAR� TO STORING OF MATERIALS, PROTECTIVE MEASURES AND �ISPOSING OF DEBRIS. 14. ALLSERVICEEQUIPMENTSHALLBEIDENTIFIEDASBEINGSOITABLEFORUSE AS SERVICE WUIPMENT. SERVICE EQUIPMENT SHALL BE FlELD MARKED WITH THE MAXIMOM AVAILABLE FAULT CURRENT AN� THE �ATE THE CALCULATION WAS PERFORMED. FIEL� MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAN� THE INSTALLATION ENVIRONMENT. 15. PROVIDECOMPUTER�BASED,OVERCURRENTPROTECTIVE�EVICE COORDINATION STU�IES TO DETERMWE OVERCURRENT PROTECTNE DEVICES AND TO �ETERMMER OVERCIIRRENT PROTECTIVE �EVICE SETTINGS FOR SELECTIVE TRIPPING. THE OVERCURRENT PROTECTIVE �EVICE COOR�INATION STODV REPORT SHALL BE SIGNE�. DATE AND SEALE� BV A PROFESSIONAL ENGINEER. a FlEL�ADJUSTRELAVAN�PROTECTNESETfINGSACCOR�INGTOTHE RE WMMENDED SETfINGS PROVIDEO BY THE WORDINATION STUDV. b. MAKEMO�IFICATIONSTOEQUIPMENTASREpUIRE�TOACCOMPLISH COMPLIANCE WITH PROiECTIVE �EVICE COOROINATION SiUDIES. B. GftOUnoING 1 GROUNOALLCON�UITS,CABWETS.MOTORS,PANELS,ANDOTHEREXPOSED NON CURRENT CARRVING PARTS OF ELECTRICAL EDUIPMENT IN ACCORDANCE bVRH NEC ARTICLE 250. 2. GROUNDINGOFTHEELECTRICALSVSTEMSHALLBEBVMEANSOFAN INSULATED GROUN�ING WNDUCTOR INSTALLED WITH ALL FEE�ERS AND BRANCH QRCUIT W �DUCTORS IN ALL CON�UITS. . ' . . CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 pAA'eN BY: JTK CHECKED BV: EJR . TE S � 25760 FirslSUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5TATE OF � O1/31/2020 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THEEXCLUSNEINTELLERUALPROPERTY OF NRRAN ARCHITEQUR& AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T. WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. �O ��P����120!gNPNINA0.CHIiERIME PRO ECT INFORMATION JAVA HOUSE COFFEE BAR MIDTOWN PLAZA CARMEL, IN 46032 ELECTRICAL LEGENDS, ABBREVIATIONS & SPECIFICATIONS ISSIIE �ATE 190410 E-0.0 TERMINATION ENCLOSURE (ETR) UTILITV C0. TRANSFORMER225KVA ASSUMEDFOR GALGIILATI0N5�ETR) Ir � I I � ,I —J L---- � LANDLORD'S TENANTSTOCK ELECTRICALROOM ROOM Jp50�KGMIL,ip3GN�-0"CIN � PROVIDECO�ESIZEDSPLICE80X EMISTING4"CON�l11T, �T�INiERCEPTANDERTEND APPRO%IMAiELY228' � EXISTMGFEEDERTOPANEL"H' � Gq � M BOOAS BOOAF @@ LANDLORD METERCENTER 400ACIRCUIi 1?AI208V,BOOA�ETR) BREAKER QYPJ 1 ONE LINE DIAGRAM E�Od SCALE: NONE PANEL H 1201208V JOOA STOREFRONT SIGN GENERALLTG DISPLAV LTG MENV BOAR� LTG BOH/STORAGE LTG SPARE SPARE SPARE SPARE SPARE ,2�� T� 24� TRANSFORMER O T/C J Hda 20N1P HX-POLE NEMA 1 LIGHTING CONTACTOR,30A.600V � CONTACT5,120VCOIL, MOMENTARVCONTACT, II H2a MECHANICALLY HEL�. � � H-26 �� H28 �� H30 �� H32 O DETAIL KEYNOTES 1 �IGITALTIMECLOCK�TORK�GUM100A�.1LHANNEL,]-0AY,MOMENTARVCONTAQS WITH MANUALOVERRI�E,BATTERYBACK-UP.AND NEMAIENCLOSURE. 2 DIGITALOVERRIDESWITCH(TORKSSA200R�2a�.PROGRAMFOR2�H0UROVERRIDE AND BEEPER AN� FLICKER WARNING PRIOR TO TURNING OFF LIGHTS. 3 CURRENTLIMITINGPANEL�LC8�T24M-SM�,SURFACEMOUNT,SIZEANDQUANTRVOF BREAKERSASINDICATED. 2 LIGHTING CONTACTOR DIAGRAM E�Od SLALE: NONE PROVIDE WIRING PER MANUFACTORER'S INSTALLATION DRAWING(TYP) SIGNALING LOOP CEILING FIRE ALARM HORNISTROBE FIRE ALARM MANUALPULLSiATION MISCELLANEOUS TELEPHONE OUTLET THERMOSTAT— �� � �1 � � � FIRE RECEPTACLE� I WALL SWITCH �ATAOUTLET ae"MAXIMUM UNLESSLOCATED ABOVE"OBSTRUCTION"SUCH AS A W UNTER. THEN 42" MAXIMUM - � �L �cwmnaiwmn FlNISHED FLOOR 4 TYPICAL MOUNTING HEIGHTS (UON) E�0.1 SCALE: NONE RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.T� DATE: 04�09�20 SVNCHRONI➢NG 21t12 AWG, iN12 AWG GND, 3l4"� H 2] winnnNci CONTROL LOOP GRA�E,FLOOR, ORPLATFORM PROVIDE WIRMG AND RELAV REQUIREO TO SHUTOOWN TENANT SOUND SVSTEM UPON FIRE ALARM ACTIVATION FAEP �FIRE ALARM JUNCTION ✓ ( 80%BVLANDLOR� � PROVIDE WIRING TO MAW FlRE ALARM PANEL AS REOWRED DETAIL NOTES 1. THISOIAGRAMREPRESENTSANPICALSYSTEMANDISNOTIMENDEDFOR INSTALLATION.SYSTEM SOPPLIER SHALLPROVIDEINSTALLATION �RAWINGS ANO SCHEMATIC WIRING DIAGRAMS. E%ACT SYSTEM REQUIREMENiS SHALL BE COORDINATED WITH THE SYSTEM SUPPLIER. SVSTEM INSTALLER SHALL 8E NICEi CERTIFIED, IF RE�UIRE� BV LOCAL AUTHORITV HAVING JURISOICTION. 2. SYSTEM SUPPLIER SHALLSUPERVISEINSTALLATION,PROGRAM ANDTESTSVSTEM AND INSTRUCT OWNER ON SYSTEM OPERATION. 3. ALLFIREALARMWIRINGSHALLBEPLENUMRATED.E%POSE�FIREALARMWIRING, 10'�0" AFF AN� BELOW, SHALL BE WSTALLED IN CON�l11T i0 A80VE ACCESSIBLE CEILING SPACE OR STRUCTURE. A. ALLCONTROLCABWETSSHALLBE GROUNDED PER NEC REDUIREMENTS ANO PER SPEQFICATIONS. 5. REFERTOSPEGRCATIONSFORADDITIONALRE�UIREMENTS.REFERTOORAWINGS FOR DEVICE QUANTIiY AND LOCATIONS. 6. FIREAIARMSYSTEMSHALLMATCHLAN�LOR�'SE%ISTINGFIREALARMSYSTEM. 5 FIRE ALARM EXTENDER PANEL WIRING DIAGRAM E�0.1 SCALE: NONE STRUCTURAL CEILING LAY-IN CEILING VIOLATION! OF HEIGHT CLEARANCE —� AREA OF WORKING SPACE t ID t6 �AI- HBGHTOF SPACEfi'6" (MINIMUM) VIOLATIONS A SUSPEN�E� CEILING IS NOT STROCTUREI vio�nnoN! 1ID26 (EJ FOR SWITCHBOAR�S MOTOR CONTROL CEMERS, AND PANELBOARDS;SPACEFORWIOTH 6'-0" AN��EPTHOFEOl11PMENTMUST BE CLEAR OF ANY'FOREIGN' PIPING, DUCTS, OR E�UIPMENT TO 6' ABOVE EQUIPMENT OR TO STRUCTURAL CEILING PANELBOARDS,ETC. VIOLATIONi EQUIPMENT IS NOT PERMITTE�IN WORKING SPACE 11028(A113) GRADE,FLOOR, OR PLATFORM FYIAlIN111:81[NaI11�R LAV- IN CEILMG AREA OF WORKING SPACE 110]6(A)� s,d. (MINIMUM) ACCEPTA9LE E3 I SUMMARY OF NEC 110.26 CLEARANCE REQUIREMENTS THI515 NOT A VIOLATION IF MORETHAN6'-0'ABOVE EQUIPMENT AND PROTEGTION FROMLEAK515 PROVIDE� �/ PIPING.ETC.PERMITTEDIF NOTWITHIN HEIGHT OF WORKING SPACE AND NOT IOVER EQUIPMENT 6�� PoRCLEARANCEOFAIR SPACEABOVEEOWPMENT SEE 1101b (F) PANELBOARDS,ETC. NOT MORE THAN 6" PERMITTE� IF ASSOqATED ANO NOT MORE THAN 6" BEYON�FRONTOF EQUIPMEM (110.1fi (A) (3�) ' • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 pAA'eN BY: JTK CHECKED BV: EJR �T E S 25760 FirslSUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5iATE oF � O1/31/2020 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THEEXCLUSNEINTELLERUALPROPERTY OF NRRAN ARCHITEQUR& AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T. WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. �O ��P����120!g NPNINA0.CHIiERIME PRO ECT INFORMATION JAVA HOUSE COFFEE BAR MIDTOWN PLAZA CARMEL, IN 46032 ELECTRICAL ONE LINE DIAGRAM AND DETAILS ISSIIE DATE 190410 E-0.1 EQUIPM ENT LIST FRONT OF HOUSE ITEM# QUANTITV NAME VOLTS PHASE AMPS NEMA PLUG WIRE PNUCIRCUIT H-57,59 H-61,63 H-65,67 H-69,]1 H-R,75 H-77,79 4 ] D300GourmetDispensers 208 1 30 (2�#1Q�1�IX10GND3/4"C H-81,83 5 1 BunnHSxElement 208 1 195 (3�#12,�1�IX12GND3/4"C H-62,64 6 1 BunnRefreshTower 120 1 6 NEMAS-15P %(2�#12,�1�IX126ND-3/4"C H-1 H-54,Sfi 7 2 ModbarSteamArm 20&240 1 14.4 NEMA6-20P X (3�#12,�1�IX126NP3/4"C H-5$60 H-4 H-6 8 3 Refrigeratars 115 1 6.5 NEMAS-15P X (2�#12,�1�IX126ND-3/4"C H-8 9 1 IceMachine 115 1 5 NEMAS-15P X (2�#12,�1�H126ND-3/4"C H-3 H-5 12 2 VitamixBlender 120 1 15 NEMAS/20P X(2�#12,�1�tt126ND3/4"C H-7 13 1 Openfacerefrigerator 120 1 10.98 NEMAS-15P %(2�#12,�1�tt126ND-3/4"C H-9 14 2 squarePOSregister 120 1 1 NEMAS/20P X(2�#12,�1�IX12GND3/4"C H-ll 15 1 printerstationinFOH 120 1 1 NEMAS/20P % �2�#12,�1�IX12GND$/4"C H-11 BACK OF HOUSE ITEM# QUANTITV NAME VOLTS PHASE AMPS NEMA PLU6 WIRE PNL/CIRNIT 19 1 IceMachine 115 1 11.5 (2�tl12,�1�tt126ND3/4"C H-10 20 1 Refrigeraror 120 1 9 NEMAS/15P X (2�#12,�1�U12GND-3/4"C H-12 21 1 freezer 120 1 ll NEMAS/15P X (2�#12,�1�IX126ND3/4"C H-14 25 1 Nltrogen6enerator 110 1 15 NEMAS/20P X (2�#12,�1�H126ND-3/4"C H-13 z� 1 o�snwasne� izoazuo i so �z�mo,�i)u1o�No-s/a^c H-1s 28 1 BunnHSXElement 208 1 19.5 (3�#12,�1)tt12GND3/4"C H-SQ52 29 1 BunnRefreshTower 120 1 6 NEMAS-15P %(2�#12,�1�tt126ND-3/4"C H-16 31 1 printerstationinBOH 120 1 1 NEMAS/20P X(2�#12,�1�p12GND3/4"C H-ll NOTES: REFER TO ELECTRICAL PL4N FOR EQUI PMENT LOCATION$ GENERAL SHEET NOTES 1. ALLBRANCHCIRCUITWIRINGSHALLBEk12AWGUNLE550THERWISENOTE�.EACHBRANCHCIRCUIT SHALLHAVE A SEPARATE NEUTRALCONDUCTOR. 2 COOR�INATEMOONTINGHEIGHTOFALLELECTRICALDEVICESWITHARCHITECTURALELEVATIONSAN� OWNER PRIOR TO ROUGH-M. 3. ALLOEVICESSHALLBEBLACKWCOLOR. � SHEET KEYNOTES 1 APPRO%IMATELOCATIONOFMARpUEE51GN,REFERTOARCHIiECTURALELEVATIONSFOREXACT MOUNTING HEIGHT. 2 REFERTOMECHANICALEQUIPMENTCONNECTIONSCHEDULEFORADDIiIONALINFORMATION. 3 IMERCEPT AND ExTEND CONOUIT TO LOCATION INDICATE� ON PLAN. REFER TO ONE LME DIAGRAM FOR CONTINUATION OF SERVICE CONOUIT AN� WIRE. 4" TELEPHONE CONOUR AND PULL WIRE SHALL BE E%TENDED i0 TELEPHONE 80ARO IN KITCHEN. COOR�INATE E%ACT MOUNTING LOCATION WITH ARCHITECTURAL ELEVATIONS. TELEPHONE CONOUCTORS SHALL BE FURNISHED AND INSTALLED FROM LANDLORD TELEPHONE BOARO TO TENANT SPACE BV THE TENANT. ' • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 pAA'eN BY: JTK CHECKED BV: EJR �T E S 25760 FirslSUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5iATE oF O1/31/2020 TH6 DRAWING AND THE IDFAS. DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THE EXQUSNE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQUR& AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T. WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. � COPYWCNi]OI9NRNIN�0.CHIIERIWE PRO ECT INFORMATION JAVA HOUSE COFFEE BAR RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel �un��\i lo•rvalM.�� DATE: 04��9�20 �----� � ��.Z � H-2�s�7I cu�� � � p � Wp I O2 � � � � L----� 1 POWER PLAN O E-0D SCALE: 3116"=1'-0" MECHANICAL EQUIPMENT CONNECTION SCHEDULE OESCRIPTION VOLTAGE PH HPIWATf MCA MOCP CONOUITBWIRESIZE PANEL CIRCUIT NOTES NOMBER AHU4 208 3 ]4 00 (3pt3,(1N18GND�11/4"C H ]4.]6)B 1,5 AHU-2 208 1 4d] 45 (2�HQ�1�#10GND�3la"C H 66,68 1,5 CU4 208 3 25 30 (3�10,�1�N10GN��314"C H 80.82,84 5 CLL2 208 1 06.6 60 (2�q6,�1�N10GND�3IJ"C H �0)2 5 ECH4 208 1 Z2 20 (2Jtt12,�1�112GN�-3l4"C H 53,65 1,4 ECH�2 120 1 ]5 20 (2�12,�1�N12GN�314"C H 29 1,4 EF4 115 1 3IW 20 (2�12,11�N12GN��314"C H 32 2,3 EF2 115 1 3IW 20 (2�12,�1�#12GN�3/4"C H 32 2,3 RP-1 120 1 ll12HP 20 (2Jtt12,�1�112GN�-3l4"C H 23 DWH�1 208 3 140 150 (3)N110,�1)#BGND411TC H 4],A9,51 � SCHEDULEKEYNOTES 1 UNRMOONTE�DISCONNECT 2 �ISCONNECTSWITCH�NEMA1-FACi0RYM00NiE�8WIRE� 3 FANCONTROLLEDBVLIGHTSWIiCH 4 INTEGRALTHERMOSTAi 5 ELECTRICALHFATANDCOMPRESSORSARENON-COINCI�EMLOA�S.PERNEC2ffi6qL0A�FORTHEHIGHEROFTHETWOl1NIT51S USED FOR CALCULATIONS. MIDTOWN PLAZA CARMEL, IN 46032 POWER PLAN ISSIIE �ATE 190410 E-I.0 . • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 oFA'eN Bv: JTK CHECKED BY: EJR �T E S O O H-26 H-26 �' �' H-26 H-26 �' H-26 OL4 I H.28 �' H-26 OL4 I &28 O H-26 �' H-26 �' H-26 OL4 I H.28 �� :Ed9R� &28 R� H-28 �' H-26 �' H-26 L4 &28 I � � �Fr N N H�20 � H�20 � H�20 � H�20 H-2fi H-26 &26 O O O O au au au au H-26 H-26 H-26 H-26 O O 26 au au H-26 y4 yv }Li �L H-26 H86 � � e L12B � � l 0 au H-26 i —i Qtl0 O 26 O au au y4 yv y4 H-26 }Li �L �L H-26 H-26 i oi hL26 ceuvi�n hL26 aOLI aOLI � C � ia: � srca B O � H-32 � H 28 H 26 ���H555-28 � � �26 &28 I�I I _ H8fi aOd L j�j. V H32 �jy� �5 v:otiem H-26 � 1 H09 aL_ I � � io� H- / M &28 � OS im r�rcxE noaa E � 25760 Firsl SUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5TATE OF . , � O1/31/2020 THIS DRAWING AND THE IDEAS. DESIGNS HND CONCEPTS CONTAINED HE0.EIN A0.E THEEXCLUSNEWTELLECTUALPROPERTY OF NRRAN ARCHITECTIIRE, AND ARE NOT TO BE USED OR REPRODUCED, W HOLE OR IN PART, WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. O COPYWLHid01$CllWNNMCH11E01/PE JAVA HOUSE COFFEE BAR MIDTOWN PLAZA CARMEL, IN 46032 1 LIGHTING PLAN O E-PA SCALE: 3116"=1'-0" LIGHTING PLANS ISSUE DATE RELEA5E0 FOR CONSTRIICTI�N Su6jec��o compliance with allregula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.T� DATE: 04�09�20 GENERALSHEET NOTES 1. ELECTRICALCONTRACTORTOREFERTOARCHITECTURAL�RAWINGSFORALLLIGHTFlXTORE LOCATIONS. 2. ALLBRANCHCIRCUITWIRINGSHALLBEp12AWGUNLE550THERWISENOTE�.EACHBRANCHCIRC0IT SHALLHAVEA SEPARATE NEUTRALCONDUCTOR. 3. WIREALLNIGHiLIGHTINGEXITSIGNS.EMERGENCVFIXTURESAHEADOFALLCONTROLSANOLOCAL SWITCHING, UNLESS OTHERWISE NOTEO. A. ALLDEVICESSHALLBEBUCKINWLOR 0 SHEET KEYNOTES 1 PROVIDEJUNCTIONBO%,SWIiCH,ANDWHIPFORSTORESIGN.ADDIiIONAUUNCilONBO%ES.CONDVIT AND WIRING MAV BE RE�UIRE� PoR A COMPLETE INSTALLATION OF SIGN. COORDINATE ALL REDUIREMENTS WITH SIGN VENDOR. SIGN SHALL BE ONIOFF WITH PHOTOCELL. 2 E%TERIORLIGHTINGANDEMERGENCVLIGHTINGBYLANDLORDTOREMAIN,PROTECTANDMAINTAIN ASSOqATED CONDUIT, WIRING AND CONTROLS DURING CONSTRUCTION. 190410 E-2.0 I C0�2 I � cu � L__J L____J 10 10 1 I MECHANICAL PLAN M1.0 I SCALE: 116"=1'A" � GENERALSHEET NOTES 1. EXISTINGMECHANICALWFORMATIONISBASEDONLIMITEDEXISTINGBUILDIN6DRAWMGSANDFlELD WORK. THE CONTRACTOR SHALL FlEL� VERIFV THE EXISTING W NDITIONS FOR ACCURACV. W NTRACTOR SHALL NOTIFY OWNER. ARCHRECT AND ENGWEER OF ANY SITUATIONS THAT MO�IFY OR INCREASE THE SCOPE OF WORK FROM THAT IS �ESCRIBED IN THE DOCOMENiS. 2. ANYTHINGNOTNOTEOASEXISTINGISTOBEFURNISHEDANDINSTALLEOASPARTOFTHISPROJECT. 3. REFERiODRAWINGSANDPROJECTSPEQFICATIONSOFOTHERDISCIPLINESFORADDIiIONALPROJECT WFORMATION AND RE�UIREMENTS. NOTIFV ENGWEER OF ANV CONFLICTS BEIVJEEN THE WFORMATION PRESENTE� AN� FIELD CON�ITIONS. a. PRIORTOANVISOLATIONOFSVSTEMS,SHUTDOWNSORDEMOLITIONTHECONTRACTORSHALLPROVIOE NECESSARY INVESTIGATION ANO NOTIFV THE FACILITIES ENGWEERINGIMAINTENANCE PERSONNEL OF WORN TO BE PERFORME� 50 AS TO AVOID ANY DETRIMENTAL SHUIDOWN OF SYSTEMS TO ADJACENT SPACES. i PROTECTEQUIPMENT,FIXTURES,PIPING,�UCIWORN,ETC.INDICATEDTOREMAINAGAINSTDAMAGEAND SOILING DURING SELECTIVE DEMOLRION. WHEN PERMITTE� BY THE ARCHITECT, ITEMS MAY BE REMOVE� TO A SUIiABLE, PROiECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND THEN CLEANE� AND REINSTALLED IN THEIR ORIGINAL LOCATIONS. 6. WHEREPIPE�OCTWORK,INSULATION,FI%TURESOREpUIPMENTTOREMAINISDAMAGEDOR DISTURBED, REMOVE THE OAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF E�UAL CAPACITY AND QUALITV. WHEREI�ENTICALMATERIALSAREUNAVAILABLEORCANNOTBEUSED,USEMATERIALS WHOSE INSTALLED PERFORMANCE EQUALS OR SURPASSES THAT OF THE EXISTING MATERIALS. ]. MAINTAINANORESTORE,IFINTERRUPTEOBY�EMOLITIONORINTHEPATHOFNEWCONSTRUCTION.ALL UTILITIES PASSING THROUGH AND SERVING OUTSIOE OF DEMOLITION AREA. 8. MECHANICALSVSTEMSINSTALLATIONSMUSTMAINTAININTEGRITVOFWALLS.PARiITI0N5AN�FL00R5 DESIGNATEDASEITHERFlRERATEDOR'SMOKETIGHT'. PROVIDECODEREQUIRE�THROUGH� PENETRATION FlRESTOP SYSTEM AT RATE� OR SMOKE TIGHT ASSEMBLIES WHERE RRE �AMPERS ARE NOT REQUIRE�. COORDINATE W/ARCHITECTIIRAL PLANS AN� GENERAL CONTRACTOR. 9. SPACEABOVECEILINGISINDICATEDTOBEARETURNAIRPLENUM.CONSTRUCTIONMATERIALSABOVE CEILING SHALL BE NONCOMBOSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED PER NFPA ]0. 10. LIMITEOABOVECEILING0.EARANCESEXIST.COORDINATELOCATIONANDELEVATIONOFMECHANICAL WORN WITH ALL DOCTINORK. SPRINKLERS LIGHT FIXTURES, AN� OTHER CEILING BOILT-IN FIXTURES. CONTACT ENGMEER OR ARCHITECT IMMEDIATELV SHOOLD ANY CONFLICT ARISE. 11. GENERALCONTRACTORTOLABELALLROOFTOPEQUIPMENTWITHTENANTNAME,SPACENIIMBERANO EQUIPMENT I�ENTIFICATION �RTU-L. ETG�. PER MALL SPECIFICATIONS AND STAN�AR�S. 12. REFERTOMALLCRITERIAMANUALFORA��ITIONALSTAN�ARDSANDREpUIREMENTS. 13. COORDINATEALLTHERMOSiATANDSENSORLOCAiIONSWITHFURNITURELAVOUTANDARCHITECTURAL PLANS. OEVICES ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR, MOUNT PER ADA REQUIREMENTS. 14. ALLEXPOSEDDUCTWORKTOBEPAINTEDBEFERTOARCHRECTURALPLANS. 15. CHANGESINDUCTSIZESSHALLBEMADEBVUWPoRMTAPERSECTIONWITHAMAXIMUMINCLUOEANGLE OF DIVERGENCE OF 15 �EGREE. 16. DUCTSIZESINDICATEDREPRESEMEMERNALSHEETMETAL�IMENSIONSANDINCLUOEALLOWANCE FORINTERNALINSULATION. 1]. SUPPLYAIRDUCTWORKNOTLOCATE�INARETURNAIRPLENUMOREXPOSEDSHALLBEEMERNALLY INSULATEO. ALL OUTSIDE AIR �UCiWORK NOT EXPOSEO SHALL BE EXTERNALLY INSULATED. 10. BRANCHDUCTSSERVWG�IFFUSERSSHALLBESIZEDTOMATCHDIFFUSERNECKSIZEINDICATED UNLESS NOTED OTHERWISE. 19. PROVIDEACCESSHATCHES(2a'x24"�PoRALLMECHANICALE�UIPMENTLOCATEOABOVEAHARDCEILWG. W ORDINATE WI ARCHITECTURAL CEILMG PLANS. 20. CONTRACTORMUSTREPIACEALLAIRRLTERSINAIRHANDLINGUNITSWITHNEWCLEANFlLTERSBEFORE AIR BALANqNG AN� PRIOR TO FlNAL TURN W ER TO TENANT. � SHEET KEYNOTES 1 MOONiREMOTETEMPERATURE5EN50RATNOTEDLOCATI0N.M0UNTAT60'AFF.COORDINAiEFINAL LOCATION WITH ARCHITECT ANO FURNITURE LAYOUT. 2 MOONTTHERMOSTATATNOTE�LOCATION.MOUNTAT48"PERA�AREQUIREMENTS.COOR�INATEFINAL LOCATION WITH ARCHITECT ANO FURNITURE LAYOUT. 3 CONNECTNOTEDSIZESOPPLYAN�RETURNAIR�l1CTWORKTOFULLSIZEOFAHUCONNEQION. PROVIDE FLE%CONNECTION AT UNIi OUiLETS. 4 PROVIDE20/200PENINGINiOPOFRETURNAIROUCTWITHBALANCINGOAMPER.COVEROPENINGWITH 112" HARDWARE CLOTH. 5 PROVI�E24/240PENINGINTOPOFRETURNAIROUCTWITHBALANCINGOAMPER.COVEROPENINGWITH 112" HARDWARE CLOTH. 6 COORDINATEWITHGCTOPROVIOE3/4"UNOERCUTONSTORAGEANDRESTROOMOOORS. ] MOUNiTRANSFERGRILLEONE%POSEOSI�EOFWALL.MOUNTGRILLEASHIGHASPOSSIBLEON EXPOSED SIDE OF WALL, ABOVE DROP CEILING. B ROUTE3/4"CONDENSATEDRAINTOMOPSINKLOCATEDINBACKOFHOUSESAFEWASTETOMOPSINK WITH 4" AIR GAP. 9 ROUTEREFRIGERANTLMESPERMANUFACTURER'SRECOMMENDATIONSANDREQUIREMENT&FlELD VERIFY LWE LENGTH AN� W ORDINATE WITH MANUFACTURER. PROVI�E LONG LME LENGTH KIT IF REDUIRED. 10 MOUNiCONDENSMGUNITSONPLATFORMWITHINPARKMGGARAGE.VERIFYFINALLOCAT10NWITH LANDLORO'S STRUCTURAL EN6MEER. PROVIOE WITH VIBRATION ISOLATION MOUNTING PA�S. 11 SMOKEDETECTORMOUNTE�INRETURNAIROUCT.SMOKE�ETECTORSHALLBEINSTALLEDBYMC, WIRED AND FURNISHED BV EC. 12 PROVIDEPREMANOFACTUREDEXHAUSTVENTWALLCAPATNOTEDLOCATION.MOUNTMINIMUMIO'�0" ABOVE GRADE AND AS HIGH AS POSSIBLE. 13 LOUVERWITHGRAVITYBACKDRAFT�AMPERL25HALLPROVIOERELIEFFROMBWL�INGWHENIN ECONOMIZER MODE. 14 OUTSIOEAIRLOOVERLI.MOUNTOUTSI�EAIR�UCTWORKASHIGHASPOSSIBLETIGHTTOSTRUCTORE. . • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 oPAVW BV�. STK CHECKE� BV: K�H �TES 25760 First SUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION aznzizozo THIS �RAW ING AND THE IDEAS, DESIGNS AND CONCEPR CONTHINED HEREIN ARE THEEXCLUSNEINTELLEQUALPROPERTY OF NRRAN ARCHREQURE, AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T. WITHOUT THE WRITfEN CONSENT OF NRRAN A0.CHITEQURE. O COPYPKNi3019NNRANAR(HIIEMPE JAVA HOUSE COFFEE BAR MIDTOWN PLAZA CARMEL, IN 46032 MECHANICAL PLAN ISSUE DATES ISSIIE DATE � CONSTRUQIONSET LHRO RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.T� DATE: 04�09�20 .�, � M I .0 AIR HANDLING UNIT SCHEDULE SUPPLVFAN�ATA 0%COOLINGCOOLINGCOILDATA HEATPUMPHEATING�ATA ELECTRICHEATINGOATA UNITCHARACTERISTICS NOMINAL MIN OA OPERATWG TAG SERNCE MFR MODELNo. NOTESIACCESSORIES TONS (CFM) AIRFLOW ESP MOTOR FAN EAPD&`WB LAT'DBPWB SENSIBLE TOTAL COOLING EATILAT OUTPUT EATILAT INPUT OUTPUT HEATING VOLTAGE COP UNITMCA UNITMOCP WEIGHT (CFM) (IN WC) �BHP) (RPM) �°F) �°F) (MBH) (MBH) STAGES �°F) (MBH) �°F) (KW) (MBH) STAGES (V�-Hz) (LBS) AHU�1 �INING CARRIER 40RUOA0] 6-0 7a0 2050 D]6 0.06 790 78-8/6].3 57A/5L0 a92 7V 2 56-01699 Aa_15 33 a7-01]0-8 260 Aa_15 2 200-3�60 740 00-0 381 14 AHU-2 BOH CARRIER FEaANB aA t10 ta00 D]6 D]6 980 75A16a.t 5431533 3t2 a65 t 6601929 4224 2.88 660I8J-0 8-0 2729 2 2004�60 a4] a6 207 14 NOTES/ACCESSORIES 1. REFRIGERANT-R410A 2. MICROMETLMIXMG90XWITHGLOBAL100%DRYBULBECONOMIZEROPERATIONWITHF�D 3. UNITMOUMED�ISWNNECT a. BELTDRIVE 5. PROGRAMMABLE AUTO CHANGE OVERTHERMOSTAT WITH REMOTETEMPERATURE SENSOR fi. VI9RATION ISOLATORS ]. MERVIFlLTERS CONDENSING UNIT SCHEDULE COMPRESSOR DATA CONOENSING ELECTRICALDATA NOMINAL FAN DATA OPERATING TAG SERNCE LOCATION MFR MODELNo. SEERIEER TONS RLA LRA FLA VOLTAGE WEIGHT NOTESIACCESSORIES QUANTITY (EA.0) (EA.0) QUANTITY (EA.0) (0.�Hz) MCA MOCP (��) CW AHU-0 GARAGE CARFIER 38AVOA0] -/11] 8.0 2 1].5 �38.0 2 1.5 20&3G0 25.0 300 444 1-13 CU-2 AHU-2 GARAGE CARRIER 25HCC5 15.0/- 4.0 1 2I0 420 1 2.9 208-iG0 3fi6 500 3I5 1-13 NOTES/ACCESSORIES 1. UNRCAPACINSHALLBEBASEOONAHRICONOITIONS 2. 95° CON�ENSING iEMPERATURE 3. R410A REFRIGERANT 4. SCROLLCOMPRESSOR 5. HIGHAN�LOWPRESSURESWITCHESONREFRIGERANTSVSTEM fi. SHORiCYCLEPROTECTION ]. FILTER-DRVERONREFRIGERANTSYSTEM B. SINGLECIRCUITCOMPRESSORS 9. LOWERE�HAILGOAR� 14 VIBRATIONISOLATORS-PA� 11. 1 YEAR PARTS 8 LABOR WARRANTV 12. 5 VEAR E%TENDE� COMPRESSOR PARTS 8 LABOR WARRANN 13. APPROVE�ALTERNATES:TRANEORLENNOH OUTSIDE AIR SCHEDULE ZONE DATA SVSTEM DATA FLOOR REQUIREO REQUIREO BREATHINGZONE ZONEAIR REOl11RE� SOPPLY QUTDOORAIR SVSTEM REQUIREO DELNERE� ZONENAME AREA OUTSIDEAIR OCWPANCV OUTSIDEAIR OOTSI�EAIR DISTRIBOTION OOTSI�EAIR AIR FRACTION SYSTEMNAME VENTILATION OUTSI�EAIR OUTSI�EAIR (SF) (CFMISF) (CFMIPERSON) (CFM) EFFEGTIVENESS (CFM) (CFM) EFFICIENCV (CFM) �CFMJ CONFERENCE 413 408 12 5.0 85 0.8 �01 800 0.1I8 AHU-0 O]10 139 �40 oiNiNc sao ma az �s asa ae eos iasa as�a CORRIDOR 64 0.06 0 00 4 0.8 5 50 0.100 STORAGE 59 0]2 0 00 1 48 8 50 0]80 PREP 2�5 0]8 4 ].5 69 48 8] 850 0.102 AHLL2 1000 iW 110 STOCK 2�3 0.12 2 00 2A 48 33 400 0.083 WOMENSRR 45 0.00 0 0.0 0 0.8 0 50 0000 NOTEs 1. SPACEOUTSIOEAIRRE�UIREMENTSBASEOON20151MC EXHAUST FAN SCHEDULE AIRFLOW ESP MOTOR FAN VOLTAGE OPERATING NOTE51 TAG SERVICE MFR MODELNn (CFMJ (INWC) (WqTTS) �RIVE (RPM SONES WEIGHT � (V-m-Hz) nBs) AGCESSORIES EF-0 RESTROOM COON GC-048 100 025 3] DIRECT 893 1.5 11S1-fi0 11 ib EF2 RESTROOM WOK GC-048 100 025 3] DIRECT 893 1.5 115-1-fi0 11 ib NOTES/ACCESSORIES 1. AMCA SEAL 8 O.L LISTEO z. oiscaNNEcr swiTcn - NEmn i- FncTORv mouNTEo a wiREo �. BACK�RAFT �AMPER-GRAVITY 6. FAN SPEED CONTROLLER- FACTORV MOUNTED 8 WIRED 5. GRILLE - WHIiE PLASiIC 6. FAN CONTROLLED BY LIGHT SWITCH ]. HANGING VIBRATION ISOLATORS 8. APPROVED ALTERNATES�. GREENHECK OR SOLAR AND PALAU AIR DISTRIBUTION SCHEDULE TAG SERVICE MOUNTING MFR MO�ELNo. MODULEI DAMPER NOTESI DIFFUSERSIZE ACESSORIES Si SUPPLV DUCT TITUS OMNI-R 22"0 - 12 S2 SUPPLV DUCT TITUS OMNI-R 14"0 - 12 53 SUPPLV LAVIN TITUS OMNI 24"X24" - 12 S4 SUPPLV DUCT TITUS 300RL NECKSIZE�2" A6-05 12 55 SUPPLV LAVIN TITUS OMNI 12'X12" D-]5 1-4 Ri RETURN WALL TITUS SOF 24"X24" - 1 Ti TRANSFER WALL TITUS 350RL NECKSIZE�2" - 1 RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel �un��\i lo•rvalM.�� DATE: 04��9�20 RE� BY DIRECTIONAL ARROWS ON PLAN, OTHERWISE FOUR (4� WAV BLOW VTE� WITH COLOR AS SELECTED BY ARCHITECT MA%.12"TO BRANCH CONNECTION � � VOLUME DAMPER IF � IN�ICATED ON PLAN 1-012" THICK RBERGLASS INSULATION W/ FOIL FAGING 6911JJVi GALVANIZEDSHEET METALDUCT GALVANIZE� ELBOW METAL OR VINVL AOJUSTABLE STRAP CLAMP (NP 2 PLACES) 15° MAX AIR FLOW / TRANSITION LENGTH I� TO BE 18' MIN DOUBLE THICKNE$$ TURNING VANES I:�YNM�[HIIM:itl4P1N9 15° MAH \ AIR FLOW � TRANSITION LENGTH TO BE18"MIN CONTRACTING FLOW �NERGING FLOW DETAIL NOTES 1. 00 NOT LOCATE DAMPERS A90VE �RVWALLIINACCESSIBLE CEILING LOCATIONS. INSULATEDFLEHIBLE CONNECTION IN VERTICAL ONLV (MAX. 5) 1 CEILING DIFFUSER MOUNTING DETAIL M20 SCALE: NONE suaa�v nie oucrwoeK, REFER i0 PlANS FOR SIZE CONiINU0U51' INSI�E FLANGE FOR MOUNTING OF SURFACE MOUNTED SUPPLV REGISTER WITH VOLUME DAMPER � Itllll�:l9qlI6Ytl1:P1N9 LOW VELOCIN ELBOWS REGISTER FRAME, SEE PLAN FOR �UCT SIZE AN� SCHEDULE FOR FRAME SIZE W � W W 30°MITEREDELBOWS y 45' MAXIMUM 2 LOW VELOCITY TRANSITIONS AND OFFSETS M1.0 SCALE: NONE 3 DUCT REGISTER DETAIL 4 AHU CONDENSATE DETAIL M2.0 SCALE: NONE MP.O SCALE: NONE LOUVERSCHEDULE SIZE FREEAREA PRESSURE TAG SERVICE MFR MO�ELNo. AIRFLOW W�H�p FREEAREA VELOCRY OROP NOTE51 (OFMJ �N) (8(lFT,) (FPM) (INWG� ACCEBBORIE6 L-0 INTAKE GREENHECK E�J-801 3A00 44X30X8 4.] �I2 0]0 �-5 42 RELIEF GREENHECK E�J-601 3fi00 44X30Xfi 4] �I2 0.09 2-fi NOTES/ACCESSORIES 1.INSECTSCREEN 2.ALUMINUM WNSTRUCTION 3. FINISH'. STANDAR� MILL PRIMECOAT-COLOR AS SELECTE� BY ARCH. 4.FRAME:STAN�AR�FLANGE 5. INSTALLATION ANGLES 6. NON-METALIC GRAVITY BACK�RAR OAMPER AIR WOLE� CON�ENSING UNR PLATFORM BV OTHERS � OViSIDE AIR �UCT wiTr+FiEx coNNEcrioN TOMIXINGBOX OA 1 RETURN AIR �UCT , WITHFLE%CONNECTION 1 TO MIXING BOX 5 REFRIGERANT PIPING Rn CABINET HEATER SCHEDULE ELECTRICHEATINGDATA FAN�ATA UNITCHARACTERISTICS TAG SERVICE MFR MODELNO. OPERATING NOTES/ INPUT OUTPUT HEATING AIRFLOW ESP VOLTAGE UNIT yyEIGHT ACCESSORIES (KW) (MBH) STAGES (CFM) (IN WC) (V-�-Hz) FLNMCA (�S) EGH-0 STORAGE QMARK AWH9404F t5 5]1 1 100 025 20&�b0 ]2 25 1� ECH-2 WOMENSRR QMARK MCSSARWH1802 0.9 3.0] 1 100 025 120-1-60 ].5 25 13 NOTESIACCESSORIES 1. STAMLESS STEEL z. oiscoNNEcr swircn 3. INTEGRAL THERMOSTAT- SET FOR 55 °F ANGLE SUPPORT FOR AHU AND DRAIN PAN- WORDINATE LOCATION OF PLATFORM RAILS FOR CONDENSWG UNIT WITH STRUCTURALENGINEER SEE STRUCTURAL DRAWINGS FOR CONNECTION �ETAILS AN� FURTHER INFORMATION � VIBRATIONISOLATOF�TYPICAL) AHU �ER CONDENSATE DRAM LINES REVENTAHU FROM RUST 4GE, DO NOT USE PVC FOR �ENSATE DRAIN LINES. KEEP fICAL CONDENSATE LINE A J�UM OF 3" FROM AHU SA SUPPLY AIR �IICT WITH FLEX CONNECTION TO UNIT. REFER TO PLANS FOR CONTINUATION AND SIZES � ELECTRONIC WATER SENSOR WIRED TO 3" �EEP WATERTIGHT DRAIN PAN, PAN SHUIDOWN UNIT WHEN CONDENSATE WATER SHALL BE 3" LARGER THAN UNIT ON ALL SIDES ENTERS ORAIN PAN. LOCATE SENSOR AT LOW CONDENSATE DRAIN LWE FROM UNIT. POINT IN PAN. SAFEWASTE TO MOP SINN WITH 4" AIR GAP. DETAIL NOTES 1. MCSHALLLOCATEAHUTOMAINTAINAMINMUM30"SERVICECLEARANCEINFRONTOFONITFORMOTOR ACCE55 PANEL FROM ANV E%ISTMG BWLOING STRUCTURE OR PIPING E%TENDING DOWN i0 CEILING PER MANUFACTURERS RECOMMENDATIONS. MC SHALL COORDINATE WITH OTHER TRADES TO KEEP THIS SERVICE AREA 0.EAR OF ANY NEW PIPMG OR CON�UIT. 5 SPLIT SYSTEM UNIT DETAIL M2.0 SCALE: NONE RECTANGULAR TO RECTANGULAR TRANSITIONS . • . . CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 OAA'JN BV'. STK CHECKED BV: KDH �TES 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.cam CERTIFICATION 02/12/2020 THIS �RAW ING AN� THE IDEAS, DESIGNS AND CONCEPRCONTHINEDHEREINARE THE EHC WSNE INTELLECNAL P0.0PERTT OF NR0.4N ARCHITERURE AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PA0.T. WITHOUTTHE W0.1TfEN CONSENT OF N0.RAN A0.CHITECN0.E. c� COPYNWIi3019NPRANPR64IK�1/PE JAVA HOUSE COFFEE BAR MIDTOWN PLAZ4 CARMEL, IN 46032 MECHANIGAL SCHEDULES AND DETAILS ISSUE DATES ISSUE DATE �1 CONSTRUQIONSET L14R0 190410 M2.0 FULL RADIUS WHERE POSSIBLE (R=W) MECHANICAL SPECIFICATIONS I. GENERALPRONSIONS a. eeNeenicoNoirioNs.cooesasralloneos t GENERnLLONDiilON50FTHECOrviRaClFOUrvDiuiHEaRCHREQURaLDPnWirvGSAENERnLaN� SPECWLCON�ITIONSOFTHEPMEFICANINSTITOlEOFARCHIiECT31PIA�AN�ANYOFTHEOWNER'S GENERnLRE�ViREMENi55HALLAPPb UNLESSNOiE00iHERW6E. 2 REFERiOiHEGENEIiALCON01ilON50NiHEPRCHIiECiOftAL�OCOM1IENTSPN�THEGENERALANO $PECIaL CONpIiION$ OF iHE alA FOF a001ilONqL REQVIREM1IENi$ REGFRDwG $AFEiY, COORDINAiION 8 COOPEMiION. YI�OFKMPNSHIP, PROiECTION, WTfING AN� PATCHING, �MIAGE TOOTHER WORK, PRELiMIINaRYOFERAii0N5.5i0RAGEnDJUSTMENIS,0.EAuiuG.ETG. 3. PLLWOFHSHALLBEINCONFORMANCEWITHPLLLOCPLd ENFORCE�,FE�ERAL STATEAN�LOCPLCO�ES au00R0iNArvCES iuCW PING AUY SGEQqL iHE ONMER REOOiREMEuiSIN a0�lii0m i0 iH WE SPECiFlEO. A_ WNiRACiORSHALLPAVFOR(JJOOBiAINALLNECESSARVLICENSES,PERMIi5AN01NSPECilONS REQNRE� i0 PROLEED WITH THE WORK. iw55NqLL iNCLUDE ALL REQOiREO C00R�iuqTION WiiH iHE LOCA W➢LIiY COIAPPNIES AN� iHEIR ASS�JGPiE� FEES OR COSiS. B. SCOPEOFWOFK 1. THISCONiMCTSHALLINCLUOETHEFURNISHING.INSTALLING.CONNECTING.ANO OPERATIONOFqLL EQUIPMENiWHIGHISAPARTOFiHE MECHANIGALSYSiEM5A55HOWNONiHE�RPWINGSANDPS eeamaeoevsimanawsTnunnaus nNvmnreaw�oe�neoewmm�isrve.HeasHowrvoNme DRNWiuGS NOR GALLED FOR iN iXESPEGFlGn1i0rv5, BU1 WXiGx �S OBvi0U5Lv NEGESSARv i0 c,UmPLE1E THE WOFKANO WHICH IS USWLLd INC W �E� IN WORN OF A SIMIIAFCHARACTERSIWLL BE FORNI9HE� ANO WSiPLLEO UN�ER iH15 CONiPACi Ai NO A�DIiIONAL COSTiO iHE OWNEP. CONiflAQOP SHALL PFON�E ALL NBOF AN� MATEkIAL9 FEOOIREO TO PROVI�E lHE OWNERACOMPLETE CO�E APPROVE� aN00PERAiiOUAL MEGinNIWL Sv51EM. 2 CARENLdFEA�SPECIFIGiIONFORALLPART50FTHEWOFK90A5TOBECONEFAMILIARWITHALL iRADES'WORxSCOFE COuSULiWIiHOixEPiPnDE5i0irv5UPEFROGERLOCAii0N5nNDaV010 IMEFFERENCES.ANYCONFLICTSHhLLBEBFOUGHiTOTHEATfENTIONOFiHEOWNEF 6EFOREWORNIS COMMENCED. 3. CONiRPCTOR95HALLBEHEL�i01WVEE%PMINE�THEPREMISESAN�SIiE50ASTOCOMPPREiHEM WiiH iHE DRnWirvGS ArvD SPEQFlCAiiON& NOiE iHE E%iSTiNG COrvDiii0rv5 ArvD OiXEF WORK lxqi WRL BEREpNFE�.PN�THENATOREOFiHECON�ITI0N50N�EF4VHICHIHEINOFNISTOBEPERFORIlEO. NO aLLOWaNGE SHALL BE MaOE i0 THE CONiRaCiOR BV REASOu OF iM5 FAhURE i0 HAVE mADE SU W EXMIINAiION OR OF ANY ERFOR ON HIS PART. o_ auexis*i�+cu*iu*vallohiecNnNicn�seavicessNaueeFieioveaiFieo.coaaeaioNs*orHe �ESIGN (JJ� INSiPLLPTI0N5HALL 9E M1IME WITHOOTA��IiIONAL WSTTO iHE OWNER 5. PROVIDEALLCU1iiNGnNDPATCHiNGRE�UiREOPoRiNSiaLUliiONOFXvnCWORx.aLLCOREORRLirvG OR CUIIING OF FIRE FATE� FLOORS.SHAFiS. AN� WALL33HALL BE FIRE9TOPPE� PFIOR i0 FINISH PAiLHirvG. nLL PErvE1RAilON55HALL BE FlPE SEnLED i0 mqiCH iHE FlRE RaiiuG OF iHE FLOOFS. SHPFiS,AN�WALLSPENETRATE�.THISCONiRACTORISRE3PON51BLET0000R�INATEOPENINGSIN WFLLSamOFL00RSWiiHiHEGENERFLiRA0ESC0uiRFCTOR.iHEFlrvnLLOLaiiOrvSArvpSIZESOFqLL �CC', �IP'_AV9 LOWE2 O�ENINGS 3YPLL BE PROVI�E� BYTHI3 COMRACTOR 6. rN6COnianCiSNn�n_SCinCW�en�LLnBOR,n1FiERinLSANDA1i5LELLANE0U5E%GErvSESFE�UiRE� PoRAL REW IRE� NECHAAICAL 9ENOLIiION OF lHE EXISiING PREPS BEING RENOVAiE�. a1HF�FM1l011i1ON5♦NI COn95i0FiHFCOM11PLEiEPEnbvAL PROGERLV�ISPOSEDOFFSIiE ( L�LC53 OiNCRlNISC NO'C� 'J� NLLMCCHNJICAL EOIIIPAIENi.PIPING,OUCIWORK AIAiERIALS EiC. � ACiRE�LIR201AiHEFIVALR5IGAHN�INSTALLPTIONOFiHEMECHANICPLHVALSVSiEMSFOR merv-w xeNovnreonxens. bdLLLAb5E�5ERNLE551�LL3E:EM1lOVE�BALKiOiHEIRPESPECiNEIrNINAN�CAPVE�ORIFiHE MAN IS NOi RCOOIPC�. THC IAAIN SHALL BE REIAOVE� IN ITS ENTIREiY. c WCRCIAHi2 B.L GB.IOJTIOV WIiH iHE ARCHRECTORAL OOCUMENiS AND iHE PRCHIIELTPNOINE OWNERS GE�ERALREp01RElAENiS. � B1WOR9NLLJJIVG.AUiNOiLIMRE0T0VqRi9MAiERIPLE�UIVMENiANDLABORBHALL9E GOPIiANiEE�FOPONEVEAPAFiERACCEPiANCEBViHEENGINEERAN00NMER. WHEREANEp01PM1lENi mnrvuFec.ureeRnesa wArereerv.r mnT exceeos orve veeR..xnTwuerwrv.r Pereiao sHu� r�aPirro iHISPROJECi. c. oocuMENTs i. mEorenwwssnREowcw�mnnc,auwoRrcsxnusEVEreFoahiEonsirvoicaTEoorvmEORnwirvcs UrvLE55 EXiSiiuG GONDiii0N50R GOORDiNnliOry i5WE5 RE�UIRE GMArvGES. 1XESE GMANGES SMnLL BE MA�E WIiH NO/��ITIONAL COSi iOTHE OWNER 1. aNYirvGiOENiALIiEMSOFNBOF,EiGuOiwGLU�EDiNiHESPEGiFlGAilON50RiXE�FAWINGSBUI REASONABLVIM1IPLIEOASNECESSARYFOFIHECOMPLEiEINSiPLUiIONOFALLAPPARATI155HPLLBE wCLVOEDirvBiD. 3. THE�FAWING9AN�SPECIFIGilONSAREINTEN�E�T03lIPPLEMENTEACHOiHERAN�ANYMAiERIALOF LFBOR CNLEO FOR iN OUE SNALL BE FURuiSNE� EVEry iHOUGH NOT NErvii0NE01N BOiH. 4_ IFEFFORSAFEFOUN�INTHE�RAWING40RSPECIFICATIONSOR�ISCREPANQESOCWRBEiWEENTHE SaMIE OR BEPNEEu iHE FlGUFES ON 1ME DRnWiuGS, Arv0 ixE SCALE OF SAmE OF BEPNEEry iHE IaRGER (JJ�3MALLER�RAWINGSOFINTHE�ESq21PTNEM1NIIERONTHE�FAWING53HPLLBEFEFERRE�TO iHE OWUER FOF PEviEYV aup FlNAL OEQSIOu GRiOR i0 iHE BIP DUE �AiE. i THEBI��INGOFiHISWOFKWILLCONTEMPLPIETHEUSEOFEQUIPMENTAN�MAiEFIALSEMCiLVAS SPECiFlEO HEREIN. WHERE MOPEixnNONE1.1ArvUFaCiURERiS MEN1i0rvEPauY0NEA1AVBEU1RlZE� SOBSTITOlEM11ANOFACiURERSAIAYBEOFFERE�ONLYASANALTEFNATEiOTHESPECIFIE�Ep01PMEM auOAlaiEPlaLArvDMIUSiBESUBMiIIE0AS5PECiFlEPirviHEARWrtECiURAL00CUNErviS. 6 MISCELLANEOOSIiEMSNECESSARYiOCOMPI£iElHE5V5lEM5CANBEOFANYRECOGNIZEO MANUFAGiVRE PROVIpED iXE$E REMS MEEi MINIAIUM SiANDARDSASSEi IN iXESE SFEGIFlGAiIONS REFER i0 EPCH SECTION FOR ANV SPECIFIC REQNREMENiS o_cooaownnoN 1. CONiRPCTORSIWLLLOCPiEI�ENTIFYqNOPR�TELTANVEYJ9TINGSERNCE3WHICHPRERE�UIRE�TO BE MNNiAINED OPEPAiIONAL ANO SHALL E%ERCISE E%iRA CAViION IN iHE PERFOflMANGE OF ALL WORK To nvoio o¢Tueeirve sucn Fnaunes. au cosrs FOR reePnia oF omm�ces To sucn seavices sHu� BE PAI� BV iHE CONiRAQOR CAUSING iHE �AMAGE. 2 EACHCOMMCi0R5HALL9EHEL�FE5PON5BLEFORPLL�AIrNGET00THEF4VORKCAWE�BVH15 WORKOfliHflOUGHiHENEGLECiOFHIS,OPHI55UBiRPOE'SPEPSONNEL. PLLPAiCHING,REPAIPWG, REPLPCEMEMlJJO PPINTING EiL.SHALL 6E �ONEAS �IFECTE� BY iHE OWNEk BYTHE CRAFfSMEN OF iHE iRa0E51NVOLVED. iHE GOSi50F SUCH WORx SxnLL BE PAiD Bv iHE CONiFAQOF LAUSiNG iHE onnwce E MEfH005 t E�ViVMENi,4iVWG,DUCPNORKEiGSXaLLNO1BE5UPPOPiEDFROMnNYCFLirvG$OiHERPiFirvG, CON�OITOR �UCIWORI( FOOF �ECK, OR 1015TBW�GING. IiEM55HALL BE SUPPORTE� FFOM ACCEPiP9LE SiRUCiVRPL BUILDING LOMPONENTS PS �ETERMWED BV iHE ARCHRECi AN� SiROQOML ENGINEEF 2. aLLRWFGErvEiRAii0N5.FLA5NINGSAu0C0UMEPFLaSHiNG55HaLLBEPERPoRME�BviHEOWrvER'S ROOFING CONiRACiOR Ai iHE REpUESiING CONiIiACiOR'S C0.ST. F. SIIBMITfALS 1. SHOP�RP'NINGSSHPLLBEVROVI�EOTOiNEPRCHIIELTOFALLE�01PA1EMM'OACCESSORIES PPOVIDEO FOR iHE PROIEQ WHEiHERSPECIFIEO HEREIN OR ON iHE �PAWINGS PENEW OF iHE SHOP �kPWING55HPLLBEFORGENERAL0E51GNCONCEPrMIOA�HERENCE WITHlHESPEQFlCAilONS QUnNiliY0F5xOPpPAWING55UBmiIIE�SxnLL8EF55PECIFlEDBYiHEAR4YirtECi. SHOPDPAWirvGS SHPLL BE PREPAREO BY iHE L�NTRACiOR SHOWING LOCATIONS PN� MEASOREMEMS FROM COW MNS OF PLL CONCEALEO AN� E%PoSEO PIPWG, OUCi�NORK CONOUR, EpUIPMENi, ACCESSORIES. EiC, ANO sueMirrEo PRiaa To wsTnunnoN. mE owNER mnv MnxE REPaoouae�E coPiEs oF mEiR oanwwcs nVARABLEFCHUSEirvPREPARF➢Ou0tSH0�UunVJwGS,HOWEVERiHEOWrvEFSxqLLuOiBEMELD RESPONSIBLE FOR NOTCONFIFMING ALL WFOFMIATION ON THE �RAWINGS PFIOR i0 FABFICAiION (JJOiOF ws*nunnou. I. PROJECiRECOR��OCOMENTS-M1IAINTAINATTHEJOBSREONECOPYOFALLWNiRPCT�OCOMENiS QEnPLVMARxEDFS'PPOJECiREGOFDCOPv'.iHESEDRnWirvG5ARE108EA1AirviaWEDiuG000 corvoinoKuvoa.eo onuv Foa cneNces eNcouNTeeeo nrvo nvniue�e nr u�nmes wairvePecnory BY iXE O�NNER. DO NOi WE FOR FlELO LONSiRUQiONI pqpJEC1 RELOFD DOCUMENiSaRE i0 BE KE4i CORRENi IMTH EMCi �INENSIONS OF ALL WORK. EOOIPMENi, PIPING VALVES, �UCM'OFK, EiC. MMK aLLiNFOFAlaliOry w PEDLWESArvDu0iE550n5i0BEEn5RYiDEN➢FlEDFROMiHEBn5E0PMNWG. UPON COMPLETION OFTHE WORK ONE SETOF iHESE �OW FIENiS SHALL BE iURNE� OVEFTO iHE OWNER FS OrvE QVALiFlGniiOu FOR FlrvpL PAM�IErvi. 3. AFiEFIHEBALPNCINGAN�ACCEPrANCETE9TSPRECOM1IPLEiE�AN�ACCEPrE�BYlHEOWNER,THREE COmGLE1ESET50FaS�BUhiDOLUMENiAiiONSHALLBEGROviOE�. iiSHaLLM0.V0EBU1N0iBE LIMITE� iOACCURAiE PIAN �MWINGSSY9TEM AN� CONTROL SCHEMATICS,SEOOENCE OF OPEFATION, WiPING �IAGMNS nNP OGERAiiON au0 MaiMENArvGE MFNUaLS II. INSULniION A GENERFL 1. INSTALLPTIONSHPLLCONFOFM1ITOiHE MPNOFACTIIRER'SFECOM1IMEN�AilONS,AN�INACCOR�PNCE W rtH RECOGuiZED w0U5TFY GPAGiiGES z c�nNnrvoorevsuaFncesPRiareTowsuunNs 3. EMEu0iN5ULFilONWiiHOUiiMERRUGiiONTHPOUGxWaLL5.FL00RS,HAmGER5aNO5iA11LaR PENEIRATI0N5. 4. INSULAiIONJALNEiPNO FlIIINGCOVERMUSiBEPLENUM RAiEO. 5. Ii15 ESSENiIALiHPiiHEINiEGRI1Y0FiHEVPP�RBPRPIERBEAIAINiAINE�. SEALALLPENEiRAilONS OFiHEVaGOR BnRPIERBvSiAGLES,NauGEP50RWHERE OIHERWi5E0ANAGED. & MAINTAINACCESSTOBALANCING�PMPERSAN�VALVES. ]. INBULAiION 6HALL 6E 6Y OWENS-0ORNINQ KNPUF OR MPNNLLE. B. MVACPIPwG t PiPirvGSHALL BEINSULAiEDWiiX FlBERGla55PIPiNG wSULFiiOUWiiHnNALL SEPV6EJALKEiAuO SELFSEAIINGIHP(A9J/39q. aINiERIORAPPLICAiION (1) CON�ENSATE WATEF PIPING- VLNCN iHICK P. FIiiWGSPNOVALVESSHALLBEINSUNiEOWIiHPRENOLOE�FIBERGNSSFIIIINGSAN�CqVEPEDWIiH n vr+�.FORh�eo Pvc Firrws cwea RELEA5E0 FOR CONSTRIJCTI�N uc����P�PEs�"ueeiNsuinreom„.„iaiNcnaoseoceui�+su�A,io�ns aF�exoeeaun� conTnu�reRiaawsuianoNwimsconTsoFuv. auuroesm�+eo Foa rHe aosto ceu i�+su�nriow Su6ee��oeom lianeewlthallre ula�ions ��sPiPiNcirvsuinnoNwu�eecomPiereivcover+�owimvervrueecwo 1 P 9 EM5KiN`. iXEE%iEFIOFCOLOROF iHE SKiN SMFLLBEWXiiE. 1FANWEFSE ofS�a�eantlLocelCodes ]AMINIMUMLONGITO�INPWOINi93HhLLBEMA�EONiHEBOTfOMOFiHE ALLBE .(dMPLEiELYWPiERiIGHi. City of Carmel r �un��\i lo•rvalM.�� . DATE: 04�09�20 c.nvncoucrworerc i. u�reaunurwsuwrewi.Hiwcnmmrc,i�inxoervsinncousrice�iNsu�nnoN�piReioeawcrc COPiE� i0 MEET NFPPj ALL OOCiWOPK NOiEO AS REIXIIRING SUCH. INiERNAL INSOIAiION SHALL BE INSiPLLEOPERTHERWIIIREMENT50FTHE5MPCNPGUIpEPNOIHEMPNOFACiURER'S RECOAIMENOAilONS. OUCi SIZES NOiED ON DRP4VING FPE SHEEi MEiPL �IMENSIONS. e nusuvPivnuoouTsmenieoucrwoarcsnnu eewanPPeowim vuziNcnoFo�sie;curr. FlBERGLA55. FOh BACxED OUC1 WRnPPiNG. 3. PLL�OLiWORNE%POSE�ONTHEEXrERIOROFTHE6111L01NG5HPLLBEL�MPLEiELVIN50LAiE�INIlH3 INGI iHIGK, 6N OENSRY, PNIN FACEO, PIGIO FIBEPGLASS BOAPO INSUUiION. INSULPiION ON iHE i0P OF irvEoucresHu�sEsucnnvs�oPEOTanuowFORwn.EreoaaiuncE iusu�nnaunrvooucrvvoarc SXnLL BE COMPLEiELY CWEREO WiiX vENiURECUD 15]]CYP JACKETiNG SYSiE1�15KiM. iHE EMERiOR COLOR OFTHE 9KIN SHPLL BE WHRE iRPN5VER9E JOINTS SHALL BE KEPTTO A MINIFIONL LONGIiU�INAL JOINiS SHALL BE M11AOE ON iHE BOiiOM OF iHE OUCiWORK. WSiALLPiION SHALL BE COMPLEiELV wnTERncnT. m Hvnc A GEUERAL 1. 1HEPROJECiCOrv515i50Firv5iALLAiIONOFAXU5,EF5ANDNLn550CiATEDCOrviROLS.ALL EASiirvG MECHPNICALE�OIPMENT,�UCiWORK HC.M1IIISiBEFlEL�`/ERIFlEOFORE%ACTLOCAiION. B PIPING 1. MFiCH EXISiirvGmATERinLWHERE MODiFlLaiiOrvSARE BEING AIaOE iOArvE%iSiING5v5iEn�. iF M1WTERIPL�IFFEFSFROM1ITHAiSPECIFIE�HEREIN.ITSHALLBESPECIFIE�INTHEBI� PFOPOSAL. 3. INDOOR CONOENSAiE VIPIN6 SHPLL 9E NPE'C LOPPER WNDENSFiE �RFW FOR iHE INDOOR AIR HPN�LING ONITINSTALLE�PERTHEMANOFPCTORERSREQl11REMENiSAN��EfAILS �FAINSHALL DiSCHFRGEINTOFN EXISiINGFL00R�PAIN. 3. REFRIGEIiAiIONPIPINGSHALLBECOPPERiYPEPCRWIiHSILVERBNSE0J01Ni50ftIN005iRV STArvpnPD'LiNE5E1ff SPEQFlLALLVMauUFnCTUFEDPoRiHEAPGLiCnTIOu. POU1EPiGirvGiHPOUGN ROOF WITH PREFABRICPIE� PIPE W RBS. SEAL ROOF PENEiRATI0N5 WEhiHERTIGHT. <. PIPE HANGERSSHALLBEADJOSiPBLECLENS HANGERSWIiHAPVROPRIqIE CLPM1IPIOEPENDING ON STPOCTORE). PROVI�E OVER512E� HANGERS FOR PIPING SYSiEMS iHAi PRE i0 BE INSUUiEO, COOPDINAIE INBiALLPTION WIiH INSOLATOR FOR RI�I� IN90UilON UNOER HPNGEPS. 5. ALLPIPINGSHALLBESIIPPORiE�ONA1rN%IMIIMOFIO'CENiERSE%CEPiCOPPERPIPINGi-014'ANO SM1IPLLER SHPLL BE SUPPOWEOON A AIMIM1IOM1I OF 6' CEMERS. 6. FIRESiOPPING-FORINSUUiEOPIPE5iHR00GHftATE�AlA50NRVWALLAN�FL00PA55EM1IBLIES, PRON�EAULAPVROVEOlHROUGHFENEiRATI0N3MIMUMESCEMFlRESr0V5Y5iEMpGPbiPS FOR RPiE� GYPSOM BOAR� ASSEMBLIES PROVI�E A ULAPPRWEO THROIIGH PENEiRATION FIRE SiOP SYBTEMNUMBERW�L1003 OTHERPRO�OCTSBVNATIONALLYAVPROVE�MANIIFPCiURER9A9USGANO HILiI. C. �UCIWOFHlJJ�AIF�ISTRIBUiION 1. �UCiWORKR00N�ORPECiPNGIlUR31WLLBEOFGPLVANIZE03TEELLONSiRUCiIONPNOSHPLLBE INSiALLE0INPCCOROANCE�NIiHiHE UiE5iE0RI0NOFiHE5M11ACNA"HVACOOCiCONffiROCiION STAN�PR�SMEfALANORE%16LPMANUPLMIOTHEFOLLOWINGVRESSUREISEN SCHE�OLF. aAiHERSLPPLVAIROUCiWORK-4"W.G POSRIVEPRESSUPESEALGLASS A b REiURN OOCPNORK � Y" W G. NEGATNE PRESSORE SEAL LLA55 B. aEXXPU5I�UCNJORN-1'W_G NEGPiNEPRE55URE5EALGLA55n. 2. ROON��LCiELBOW39HALL9ELONGSWEEP,1-0I4TIME9THECEMERLWERP�IOSUNLE95CLFhRANCE ISNOi AVPIUBLE Ai WHICH iIME MIiERE� ELBOWS WRH iUPNWGVPNE55HALL BE U➢LI2E�. 3. RECTANGONFELBOWSSHPLLBEFORNISHE�WITH�009LETMCNNESSTORNINGVANES. iURNINGVANES SXALL BE FASIENE04ViiH n DOUBLE ROW OF SCREWS. <. FLEXIBLECONNECTIONSAiiHE WLETAN�OOTLEi0FPH0'SCENTRIFOGALFqNS. INSTALL FLE%IBLE CONNECiIONSWRH]'WIOE�OUBLENEOPRENECOAiE0FNA1EREiARDNJi,NWA$OAAPPROVEO, FlBERGU95FLEXIBLECONNECTION.FLEXIBLECANNECTIONiOHAVEAMINIMIIMOF44GAG 3"WI�E E snEErryiE*n�counasvErtn�nrvENnvnr*wcnEoroEncxsioE. 5. MRERE�OFFSETSGREPTERiHhNI��EGFEE5INEITHER�IFECTI0N5HALLNOiBEPERMIIIEO. G GHANGESiNDUQ51ZE55MPLLBEmADEBVUNiPoRNiAPERSECiiONWiiHAmA%iNUAIirvGLU�EnNGLE oFoivERCENCEOFisoEcnEEs. ]. REGIANGUL1RBaLArvGiNGDFMPERS-RUSKiNMD255MnLLBE5INGLE8U10EUPi06"iNXEiGMinN095' INWI�TH,AN�ROSNINMWSM1NLiVBU�EFOFURGEFSIZES PLLROON�BAIANCING�PMPER59HALLBE COMNERQALGRa0E5iNGLEBIADEUP10tfi"INDiaMEiERSxnLLiuCORPORAiELOGxINOiYPE IN�ICATINGA�JOSTMEM. BAWJCING �AMPERS SHALL BE INSTALLE� IN ALL 9RPNCH �lICi50FF MAIN au00ry ALL inP50FF DUCiS i00iFN5ER5 UNLESS OiHEPW6E u0iE00u ORAWINGS. 8. FINPLCONNECilON5i0�IFFO5ER5MAY9EluN�EWITHFLEXIBLEAIR�OCiWORNBUili503EI5LIMIiE� 1051RAiGHiHORIZOmiALOFVEPiiGLRUNS ALLGHArvGE50F01FEGiiONirvqDULi5Y6iEAl (GALVANIZE�OF FLE%IBLE�3HPLLBEMA�EWIiH PNAPPROPFIATEGPLVPNIZE�ELBOW. MP%IMOM LENG1x OF ANV FLEXiBLE AiR �UCi iS S�0". 9. FLEXIBLENR�UCi5T0�IFFlI5ER53HPLLBEATCOFUBBERPFO�UCiS,WGMO�ELUPCp�]O,INSUUiE� �R=a.Z�, U1.10� RniED nND 0.n591 aiR GONNEQOF. MF%iNUAI LENOIN OF REXiBLE AiR DUGi i0 �IFFOSERTO BE 5-0'. ID. REXiBLECONrvEC10R0UC15aiiHEINLE150FiHErvEWVAVBO%ESSHALLBEAiCORUBBERGRODUQS, WG M02L LPC P050, ONJNSOIAiEO. LLL 1B1 RAiE�ANO CN551 AIR CONNECiOft. MPXIMOM LENGiH OF REXIB.E�'JC PT9C%WLPi�9EJ-0". 9. SOP'02iALLSHEEiNHALPN�EQUIPMENiFROMANGLEIFONCONNECTE�i05iROCi0RAL5lEEL. �0 60T SUSPEN� �ULi ORE�UIPME�FFOM MEiAL �ECKORJOIBi 6RI�OINO. iz canvirrxm�Fnnorvraeen000s aSFFfIP�WIAGSGHFf:UIS. is o�rsmeniewrnae aseesciaou�eory orenwirvos 1A LOWERS aSEESCHE�OLEON �RAWINGS. 15 GRAVIiYBACN�MFi�PMPERS aSEESCHE�ULEON �RAWINGS is corvreo�oaMceas a5EE5CHE�OLEON ORAWINGS 1]. GRILLES,REGISiERSAN�DIFFO5ER5 aaeescHeou�eou oenwirvcs IV. XVALEQUIGMENT A GEUERAL 1. INSiPLLPiIONOFPLLEQUIPMENiSHPLLCOMPdWIiH iHEMANUFPCNPER'SINSiALLPiION INFORM1IPiIONPN01N5iRUCilONS,RE�UIREMENTSPNOANYA001ilONALGIII�ELWES. LONTRALT�R SHALLPRONOEALLAO�IiIONALREOUIREOACGE55YIRIESREQUIRE0i0CAMPLEiEiHEINSiALLATIONS 2 HVALE�UIPM1IENTSHPLLBE"BTPRTE�UV'BYAFPLTORYTMWEDPNOAUiHOR6E05ERVILE iECHNICIAN. 3. ALLFACipRY3TARiI1PFORMS9HALL9ECOMPLETE�PN�TOPNE00VEki0THE0WNEkWITHALL COMPLEiE� WARRPMV CFPOS PRIOP i0 FlNAL APPflOVAL. e. macao�eocoNoervswcuwrs 1. SEE�RAWINGSFORIN�IVI�UPLONIiPERFORMPNCEREpUIFEMENTS_ L FURNiSHArvDiuSiALLiNSUlAiEO FEFRiGERATIOuiUBirvGBEPNEErvEVnGOPAiORCAILSArvD CON�ENSINGONIiSPERM1IPNOFACiORERSRECOMMEN�ATIONS CONiRPCTOF MAYOTILIZE REFRiGEFArviLWE5Ei5A5FURNi5ME0BviHECONDENSERAIaNUFALiURER. 3. REFRIGEIiANiLINESEiPENEiRATIONSiHR00GHiHER00FSHPLLBEPERiHEBl11L01NGOWNERAN� aRGHrtELP6RE0UBENErviS. SEEGLauSPoRPEiAh6. c. aw Hnrvouuc uNi* 1. SEE�MWINGFORIN�IVIOUALUNRPEPFORMANCEPEp01REMENiS. o. Fnrvs 1. CEILINGF(JJS aSEE�MWINGFOflIN�NIOUALUNR PEflFORMANCE. vi. corvTao�s A. CONiR�L WIWNG SHPLL BE VLENIIM RAiE� LABLE WIiH COLOR GO�E018 AWG WIREB (MINIMUM�. B. llINiMCiOR SHALL PROVIOE PLL WIRING BEiWEEN iHERMOSiAi AN� EQOIPMENi (PIR HPNOLER POOFiOP ONIi, CON�ENSING UNIL ETC.�. C. LYINiRPCiORSHALLFOPNISHANDINSTALLAIPOVOLiSOPPLVAIR�UCilAOUNiE�PH0i0ELECTPICSMOKE oEhcToa. oE.ECTOR snnu eE wiREo. ar.xE EiECTaicu coNmncroR, Ta snur oowN urviT uPory AGiiVAiiON. � LOWLCONIROLPPNEL55HPLLBEPRON�EOFORALLRELAVS.TRAN50110ER5,PN00iHER FlELOIMERFPCE DEVIGES 1. PANELSBHALLBENEMAiYVE301TABLEFOREACHAPVLICATION. 1. aLLWiPiNGINPnNELSMnLLBER0UiE0iNWiRwGiRFYS. 3. PFON�EFlNALPSBNLTCONiFOL�RAWINGM00ME�IN91�EiHEPANEL a COrviRnG10R5HALLPROviOEnLL1MRiNGAuOIORiVBINGBEiWEENGONiPOLPnNEL(S�ANDREMOIE CONiROL�EVICES E. IHERMO5iPT5 1. FURWSHArvD wSiALLAMOrvEYWELL�DaYPROGRabIMnBLEHEnTINGC00LiuGiHERAlOSiainND0.EAR LOG(ABLECAVERWIiHAPPROPRIAiECONiROLWIRINGBEiWEENiHEft1A0.STAi,5EN50ftSPN0AHO5A5 REQUIREDTOPROVIOEFCOMPLEfEOPEMiIN6SVSlEM WIRIN6SHALL9EMINIMUAIIBAWG 2 IHERM1105iPT55HALLBEM00NTE�WHEFEIN�ICATE�ONTHE00CUMENiS. 3. CONiRqCiORSHPLLPROGMMiHER1A05iPTPERiHEOWNERSREWIREMENi5PN0iRFINOWNERS PERSONNELINiHEOPERAiIONAN�PROGftAMMINGOFiHEiHERMOSiAiAN�5Y5iEM. F. IEMPERANFE5EN50R5 1. FORNISHAN�INSTALLTHEiEM1IPERAiUFE5EN50R5WIiHPPPFOPRIAiECONIROLWIRINGBEiWEEN iHERMOSiAi,SEN50RPNOAHUSASREQUIRE�iOPRWIOEPCONPLEiEOPEPAiINGSVSiEM. WIRING SIWLLBEM1IINIMOM1118AWG. z. *EMaERnruaESErvsoassMnueEwouu.EowHEREiNoica*EooNrHEooamEN.s. vn. TesnNcnrvoenurvcirvc A. rEs.irvoallo eunNcirvc snAu rvoT eEciry uNmmE srehn� Hns sEEry comPiErEo, is w Fuu woaarva OR�ER AN� ALL EQNPMENi SiPPiLP HAS BEEN COMPLEiE�. lLLL HVACSVSTEMSANO EOOIPIAENi SHALL BE POi INIDFULLOPERATIONPNOiHEOPERAiIONOFSPMECONiINUE�DORINGEALHWORNING �PVOFIHETESTING nNo eaiarvciNc. B. ANIN�EPEN�ENT'APBC'OR'NEBB"CERTIFIE�AIRAN�WATERBALANCECONiFACTOFSHPLLTESTAN�BAIANCE iHE SY4EAI PNO REVORi RESULiS i0 iHE ENGWEER AND iHE OWNER. 1. ALLWORKSHPLLBE�ONEON�ER�IFECTSUPEFVISIONOFiHECERiIFIE�BNANCINGENGINEERAN�BV ouuiFieo aeinrvcirvc recHrviaeNs. P. MEiH00.SANOFORMSSHALLBEINACCOR�ANCEWIiHiHECERiIFIGiIONAGENCIES RECOMMEN�PilONSPNOREOUIREMENi9. 3. COMPLVWIiHPSHRPERECOMWENOAilONSPERiPININGiOMEPSUREMENiS,INSiROMENi5,TE5iING, Ao�us.iuc amo en�aNaNc. J. ALLQUANililE55HALLBEWIiHIN10Wo0FiHE�E5IGNVPWES. s. corvTaacroRsnnu PRovioEnrvvsnEnvEcnnrvcEsaEouiaEooNmExvncuNiT. G PUNPnLiGNMEMSXnLLBELMECKE0Au05XaLLBEREnLiGNEDBYA�UALiFlEDiECMwQAm. D. PEPPoRMArvCETE51 1. AFiERALLHVACE001PMIENiI5W5iPLLE0,iE5iE�ANOBNANCE�P55PEQFIE�HEREINiHEVSHALLBE OPEPAiEOANOPLPCE�UN0ER911kVEILLPNCEFORAPE@IOOOFAREPSTONE(1)MV,iH18 MAV INCLUOE iHE OAV OF SiARiUP. i0 VERIFY iHAiALL EpUIPMENi IS PflO�UGING iHE REQUIRE� CAPAGRV lHE HVAL LONTRACiOR SHALL 6E RESPONSIBLE PoR iHE OVERATION OF iHE EOOIPMENi pURING iHE ENiIftEPER10�. 2 lESi BHALL 9E PERFORME� WITHALL CONTROLS IN iHE AUiOMAiIC POSIiION PN� BUILOING LIGHTS DAIAPEPS ETC. POSIiIONE�TO51MUNiE NORIAAL OPERPiION OF iHE HVAGSYSiEM. 3. �IIRINGTHEiESLCONTROL9ETfING4MPVFC-0OIkEA��ITIONALA�JOSTNENTSTO PFO�UCETHEBE9T BALPNCE�SVSiEMOPERPiION. iHEIRFINPLSEiiINGOFEACHOPEPAiINGPNO SAFENCONiROLSHALL BE RECOFOE�. iHEV SHALL INC W�E BUi NOT LIXIIIE� i0, THEkMO5TAT5 LlM1lli CONTROLS AN� OTHER SIMILARIiEMS. <. SHOIIL�L�MPLEfIONOFIHEINSTALLATIONOCCURAT511CHTIMETHATTHERE�I11RE0VERPoRMPNCE iESi AIUSi BE CON�UCiE00UPWG A SEPSON WHEN iHE NLL OPEPAiION OF EIiHEfl iHE HEAiING OP COOLING SYSiEM GN NOiBECHECKE�,THECONiRPCTOFSHPLLPERFOFMTHEiESTAN�RECOR�ALL SUCXDniAA5i5AVAhnBLE WiiH5v5iEMOPERAiINGAViOMniiGALLVUNDEFiHEPPEVAhwGWEFiHER CON�IilONS. IHAT PART OF lHE SYSiEM1I WHICH L(JJ NOi BE iESTE� SHPLL BE �ENYE� UN➢LTNE WEAiXERi5n4PP0VRiaiEaiYPXiCMiiA1E iXE FEmAiNirvG PARiOFiHE RE�ViREDiE5i55HALL BE corvoucreonrvoonTnnecoaoeonccoaoirvc�r E ACCEPiANCEPN�LHECK-0Ui-0ONiW1CTOR5HALLPROVI0E00PLIFlE�PER50NNELATNOA��IiIONPLCOST i0 iHE OWNER, AS MAV BE REp01RE� BV iHE ENGINEER FOR iHE PORPOSE OF VEft6VING PROPER OPEPAiION ANOINSTPLLPiION OFTHEIRWORKPTIHETIMEOFRE�0E5TFORPCLEVTqNCE. -/COMcheck Software Version 4.1.1.0 Mechanical Com liance Certificate V P � Projectlnformation energyCoee_ 90.1(20W)Slentler0 Projec� Tllle�. JdV3 HOI15¢ Cdflll¢I L«atron: Carmel, Intliana Ciimate Zone�. 5a rrojecrryoe: Hiteration ConaWctlon Slle'. OwnerlAgenC �es9ner/ConVactoc MitltOwn Plazd TES Engin2Plipg CARMEL IN 4fi032 25)fi0 Flrst S[ Clevelantl, oH 44145 Mechanical Systems List Ouantlry Sys[em Typa & Oescription 1 AH01 SpIilSyslem HealPump Healing 4!eCe: Capaclq� - 80 kB�WM1. vmposee erec�ency = sao coa, aequ�rea errciency = aaa cov Coolln8 Motle: Capacry = ]2 kBWIM1, ProposNE%iclency=ll]OEER.ReQUIredEfficiency: t100EER FanSyslem FANSVSTEM1--Compliance(BrekeHPmelbotl�:Passes Fans: FHN 1 Supply, Conslan� Volume. 2050 CFM, 1 0 mo�or namepla�e M1p, 0 9 tlesign brake M1p (0 9 max. BHP) SVSTEM VERIFlCNTION REp W RE�. 1 AHLL2 Spli�5y51¢m H¢d�Pump Healing MMe: Capatiq = 42 kB�WM1, Prop�setl ER¢iency= 1200 HSPF, Requiretl EH¢ienry= ]]Q HSPF Cooling Motle:Capaciry = 66 kB�WM1. Pm�aeUE%Iciency=1500SEER.RequiredElfmienc¢ 13005EER Fan Syslem: FAN SVSTEM 2-- Compliance (Brake HG me��o0)'. Passes Fans'. FpN 2 Supply, Gons�en� Volume. �600 CFM, LO motor nameplata M1p, 0_8 Oeslgn braka M1p (O.B mv. BHP) SVSTEM VERIFICNTION REOOIRE�. Mechanical Compliance Statement Complianre Statement The pmposed mecnanical alteration pmjec[ representetl In tnls tlocument Is mnsistent wiM tne bulltllnq plare, specifca[ions, antl o[her calculations submi[te� wi[b Nls permi[ appllca[ion. The pmposetl mechanlcal sys[ems bave been desiqnetl to meel [he 901 �200]) Sfantla�tl requlremen[s in COMcheck Version 4.1.1.0 antl to mmply witb any appllca�le mantlatory requiremen[s Ilsted in Me Inspection Cneckllst. Steohen Kruoar- Mechanical Engineer 4+u,6�.� a,, 01/17/20 N3mE-TitlE Sign [p�P �2tP Pmject Tltle: fava House Carmel Report �ate: Ol/1)RO oata fllename: G:\Curran ArcnlceccureVava House Carmel Page 1 of 9 IN\Englneering\MechanicapCAJAVAHOWECARMEL.INMECH.COMCHEIX.cck ,,n� COMcheck Software Version 4.1.1.0 �;/ti Inspection Checklist � v � Energy Code: 90.1 (2007) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is pmvided by the user'm the COMcheck Requiremen[s screen. Por each requiremenq [he user rer[ifies [ha[ a mtle requiremen[ will be met antl how tha[ is tlocumen[etl, or tha[ an eacep[ion is being tlaimetl. Where compliance is itemizetl in a separate table, a reference to [hat table is pmvitletl. �� # � Plan Review Camplies? 6 Req.ID li 4.22. Plansspeciticationsantllor OComplies 6A2 calcula0onspmvitlealllnforma[ion ❑DoesNo[ �GR2�° wiMwM1lchmmpliancecanbe �No[Observable tle[ermined fortM1e mechanical rys[ems antl equlpment antl �No[ Appli<able tlo<ument wnere e=cepeons ro me s[andard are claimed. Loatl Calculations pe� aUeptable englneenng standa�05 and M1antlbooks. 42.2. Plans,sped�IcaOons,and/or �Complies ).41 calculationspmvitlealllnPormation �DoesNot �PR3�� wiNwM1lcM1mmplianrecanbe pNo[Observable tletermined for [M1e servlce water �No[ A I ble Fea[ing sys[ems antl equipmen[ and pp ��ca eo<�mem wnere e.�evao�: m me Stdntld(tl d(¢ CldimPtl. H0I wdf2f sys[em sized per manufacNrer's sizing 9Jitle. fi.)2.4 OetailetlinstructionsforHVAC �Complies �PRSP Sy5[Pm5[Omm'65i0ninglnflutl2tlOn OpoesNo[ [he plans or speclflcations for pmjec[s �No[ Observable >=50.00Oft2. ❑No[Aoolicable 0.equlrement will be met. Requlrement will be met. Additional Comments/Assumpfions: 1�H1gM1lmpact�Tler11 2 Metliumlmpac[�er21 �3 Lowlmpact�Tler31 Gm�ec[Ttle�. �avaHouseCermel Reporttla[e:011l)RO �ata filename'. G'.\Nrran Nrchi[ec[ureVava House Carmel Pa9e 2 of 9 IMEngineering\MecbanlcapCA JAVAMOUSECARMEL.IN.MECH.COMCHEIX.cck Comments/Assumptlons Requlrement will be met. . • . . CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 oFAeIN BV�. STK CHECKED BV: K�H . TE S � 25760 First Stree� Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.cam CERTIFICATION 02�12�2�20 THIS �RAW ING AN� THE IDEAS, DESIGNS AND CONCEPRCONTHINEDHEREINARE THE EHC WSNE INTELLECNAL P0.0PERTT OF NR0.4N ARCHITERURE AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PA0.T. WITHOUTTHE W0.1TfEN CONSENT OF N0.RAN A0.CHITECN0.E. c� COPYN6/i3019,CIMFANPR64IECNRE JAVA HOUSE COFFEE BAR MIDTOWN PLAZ4 CARMEL, IN 46032 MECHANICAL SPECIFICATIONS AND COMPLIANCE ISSUE DATES ISSUE DATE �1 CONSTRUQIONSEf LHRO 190410 M 3.0 4"HOUSENEEPING GENERALSHEET NOTES 1. REFERTODRAWINGSANDPROJECTSPEQFlCATIONSOFOTHER�ISQPLWESPoRADDITIONAL PROJECT INFORMATION AND REpUIREMENTS. NOTIFV ENGINEER OF ANV CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONOITIONS. 2 PLUMBINGINSTALLAiIONMUSTMAINTAININTEGRITVOFWALLS,PARTIT10NSANDFL00R5 �ESIGNATE�ASEITHERFlRERATEDOR"SMOKETIGHP'. SEALAROUNDALLPENETRATIONSTHROIIGH RATEOORSMOKETIGHTASSEMBLIES. WOROINATEWITHARCHITECTIIRALPLANSAN�GENERAL CONTRACTOR. 3. PROVIDESTOPVAWESATEVERVFIXTUREONBOTHHOTANDCOLOWATERSUPPLYLWES.VALVES, ESCUTCHEON$FlTfINGS,ETC.MUSTBECHROMEPLATEO. WHEREEXPOSEqCHROMEPLATEDPIPE IS TO BE IISED. 4. ALLSANITARYPIPINGINSTALLEOUNOERGROUN�ISTOBEPITCHEOATI°/SLOPEEXCEPTFOR2" LWES WHICH SHALL BE PITCHED AT 2% SLOPE. 5. ALLOVERHEA�PIPINGISTOBEROOTEDiIGHTTOBUIL�INGSiRUCTURE. 6. �ONOTROUTEANVWATERCONVEVINGPIPINGOVERELECTRICALEQUIPMENT. ]. ALLACCESSIBLEP-TRAPSMUSTBEPROVIDEDWITHBOTfOMCLEANOUTPLUGS. B. INSULATE EXPOSED P-TRAPS. HOT ANO COL� VALVES AND PIPING SERVING HANDICAPPED LAVATORIES. 9. ALLCONCEALE�PIPINGSHALLBETESTEDANDPROVENLEAKPROOFPRIORTOCONCEALMENT. 10. ALLFLOORORAINSANDCLFANOIITSARETOBEINSTALLEDFWSHWITHTHEFINISHE�FLOOR. 11. ALLFLOORSINKSARETOBEINSTALLE�EITHERFWSHWITHFINISHEDFLOOR,ORRAISEDPERLOCAL CODE REQUIREMENTS. 12 ALLPIPWGSHALLBEWATERTESTED.NONPVCPIPINGMAVBEAIRTESiEO. � SHEET KEYNOTES i vs��co�ownTeRoowNwwnuTowai. z v2^ cw, v2�� r+w oowN w wnu ro uv��. 3 3/4" HW (ta0° FJ ANO 3/a" CW DOWN IN WALLTO PRE-RINSE FAUCB. COORDINATE RNAL CONNECTION REpUIREMENTS WITH K.E C. 4 3/4"HW(140`F��OWNINWALLTO�ISHWASHER.PROVI�EWITHBACKFLOW�EVICEkWATTSA55E 1056. COORDINATE FlNAL CONNECTION REQUIREMENTS WITH K.E.C. 6 3/4"HWAND3l4"CWDOWNINWALLWITHFULLSIZECONNECTIONTOMOPSINK. 6 2"CWMAWCONNECTTOEXISTINGINTHISAREA.CONTRACTORTOFIEL�VERIFVEHACTLOCATION PRIOR TO COMMENCWG WORK. CONNECT �OWNSTREAM OF BACKFLOW PREVENTER ANO fdETER. 1 1"CWAN�1"140°HWTOTMV.1"110`HWOIITLET. REFERTOPLUMBINGFIXTORESCHE�ULEFOR MORE INFORMATION. 0 1-112" CW AN� 140° HW TO WATER HEATER. REFER TO DETAIL FOR MORE MFORMATION. 9 CONNECTTOEHISTINGSANITARVPIPINGBELOWFLOOR.CONTRACTORTOFIELDVERIFYEXACT LOCATION PRIOR TO COMMENCING WORK. 10 IN�IRECTLV WASTE EACH COMPARTMENT FROM 3 COMPARTMENT SINK, RUN TO FLOOR SINN AND PROVIDE WITH AIR GAP. FOR REFER i0 DETAIL FOR GREASE TRAP INFORMATION 11 2" VENT PIPWG. CONNECT TO NEAREST EXISTING VENT PIPWG MAIN. CONTRACTOR TO FlEL� VERIFY E%AQ LOCATION PRIOR TO COMMENCING WORK. 12 112" CW DOWN TO COFFEE MAKER. PROVIDE WITH BACKFLOW DEVICE, itWATTS ASSE 1022. 13 ll2' CW �OWN TO WATER �ISPENSER. PROVIDE WITH BACKFLOW DEVICE, MWATTS ASSE 1022. 14 1/2' CW �OWN TO ICE MACHINE. PROVIDE WITH BACKFLOW DEVICE, #WATTS ASSE 1022. 15 112" CW TO TRAP PRIMER WITH 112" CONNECTION TO NEARBY FLOOR DRAIN. REFER TO DETAIL ON SHEET P2.0 16 ll2' CW WITH SHUT-OFF VALVE AN� ASSE 1056 BACKFLOW PREVENTER WITH THRFA�ED CAP FOR CONNECTION TO CHEMICAL �ISPENSING E�UIPMENT. ' • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 �AA41N BY: JJC CHECKED BV: KDH �T E S 25760 FirslSUeet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5iATE oF RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.�� . DATE: 04�09�20 1 I PLUMBING PLAN P7.0 I SCALE: 5H6"=7'�0" /� 1U� � 3' `J I \\ 7' I \\ ��� �� I i.1 � I% �� �� �i �� � f% I � � 2 3� �\ � 3" 2�\ � 5� \�� ��2 J+ i �\\ ��)i 2� �,11�� I v �p � p�� %I ^��i� � W% 5�� �y�Q � F�� � � � `� � o-��- 3 � ,�� i ����il� � �^��J i � �� . -FV�� �'�\ 2�� ��. �. �.��2" �/.� �. � Y� � � �'�V; ���2 ���y F� i���NE � � s � �> /�l � �u� (iSPN „ / � �.U�-H' � �,1r2" � pISM�A���� 2' 3' 2 PLUMBING RISER DIAGRAM P7A SCALE: NONE � 7 � 2�� oi/si/zozo TH6 DRAWING AND THE IDFAS. DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THE EXQUSNE INTELLEQUAL PROPERTY OF NRRAN ARCHITEQUR& AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T. WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. � COPYWCNi]OI9NRNIN�0.CHIIERIWE PRO ECT INFORMATION JAVA HOUSE COFFEE BAR MIDTOWN PLAZA CARMEL, IN 46032 PLUMBING PLAN issue onre 190410 P I .0 ABBREVIATIONS w��nssRevinTioNss�owNnReNOT pLUMBING SYMBOLS NECESSARILY USED ON DRAWINGS) ABV ABOVE � % ELBOW UP MAX MAXIMUM ADJ AOJUSTA&E MBH 1000BTUPERHOUR � ELBOW�OWN AFC ABOVEFINISHE�CEILING MC MECHANICALCONTRACTOR � VALVEINOROP AFF ABOVEFINISHE�FLOOR MECH MECHANICAL AFG ABOVEFINISHEDGRADE MFR MANUFACTIIRER pIRECTIONOFFLOW ANSI AMERICAN NAPL STANDAROS INSiITOTE MH MANHOLE ARCH ARCHITECT.ARCHITECTURAL MIN MINIMOM -v� TEEOUTLETUP ASME AMERICANSOQENOFMECHANICALENGRS MT� MOUNTE� ASSV ASSEMBLV MUA MAKE�OPAIR � TEEOUTLETDOWN ASTM AMERICANSOQENOFTESTMGBMATLS �I� UNION AUX AU%ILIARY N/A NOTAPPLICABLE AWS AMERICANWELDINGSOCIETV N.C. NORMALLVCLOSED 0 E%PANSIONJOINT AWWA AMERICANWATERWORKSASSOG NEC NATIONALELECTRICALCO�E BIF BELOWFLOOR NEMA NATIONALELECTRICALMFR'SASSOG � BALLVALVE BAS BUIL�INGAUTOMATIONSYSTEM NFPA NATIONALFlREPROTECTIONASSOC. BLDG BUILDWG NIC NOTINCONTRACT � 058VVALVE BMS BUILDWGMANAGEMENTSVSTEM N.O. NORMALLVOPEN p4 GATEVALVE BOP BOTTOMOFPIPE NTS NOTTOSCALE BOS BOTfOMOFSTRUCTURE OM OVERHEA� � CALIBRATEDBALANCINGVALVE BTU BRITISHTHERMALONIT OC ONCEMER {v CHECKVALVE CC CONCRETE OD OVERFLOW ORAINAGE CFH CUBICFEETPERHOUR OPNG OPENING � PRESSUREREDUCMGVALVE CFM CUBICFEETPERMINOTE OR� OVERFLOWROOF�RAIN a CENTERLWE OS&V OUiSIDESTEMANDYOKE �r� BUTTERFLVUALVE CLG CEILING OSHA OCCUPATIONALSAFETVBHEALTHADMW. � 3WAYSELFOPERATINGVALVE CO CLFANOUT PB PUSHBUiTON 4 WNN CONNECT,CONNECTION PD PRESSUREDROP G� 2WAYSELFOPERATINGVALVE COP CLEANOViPLUG PH 0 PHASE � COL COWMN PIV POSTINDICATORVALVE MOTOROPERATEDVALVE CTE CONNECTIDEXISTING PLBG PWMBING CW �OMESTIC WLO WATER PSI POUN�S PERSQUARE INCH — PIPE G111�E D �EPTH PRV PRESSURERELIEFVALVE DEG DEGREES �-F HOSEBIB DIA(ORO) OIAMETER RCP REFLECTE�CEILWGPLAN DIM OIMENSION RD ROOFDRAIN —SAN— SANITARVPIPING DN OOWN REINF REINFORQNG,REINFORCED -----V----- SANITARVVENTPIPMG DOM OOMESTIC REL RELOCATED DS �OWNSPOUT REQ REpUIRED RWC STORMPIPING�ABOVEGROUN�) DWG �RAWWG REV REVISION,REVISE REX REMOVEEXISTING ST STORMPIPING�UN�ERGROON�) EA EACH RPM REVOLUTIONSPERMINUTE EC ELECTRICALCONTRACTOR RR REMOVEANDRELOCATE 0� OVERFLOWDRAINPIPING ELEV ELEVATION pWC RAINWATERCONOUCTOR --- WLDWATER�CW)PIPING ELEC ELECTRICAL ENQ ENCLOSURE SAN SANITARV HOTWATER�HIh�PIPING EQUIP E�UIPMENT SECT SECTION ESP EXiERNALSTATICPRE550RE SF S�UAREFEET,SQUAREFOOT --- HOTWATERREQRCIILATION�HWR) ETR EXISTINGTOREMAIN SHT SHEEi EXH EXHAUST SPEC SPECIFICATION G NATURALGASPIPING EX EXISTMG S� S�UARE ST STORMWATER � CAPONENDLINE FCO FLOORCLEANOUT SID STAN�AR� 4FS FLOWSWITCH FD FLOORDRAIN SURF SURFACE FF FlNISHEDFLOOR SUSP SUSPEND 4P5 PRESSURESWITCH FS FLOORSINN FLEX FLE%IBLE IDH TOiALOVNAMICHEAD � TBPRELIEFVALVE FP FIREPROTECTION iHRU THROUGH FPM FEEfPERMINUTE iP TOiALPRE55URE PRESSOREGAUGEWITHGAUGECOCK R FOOT, FEET TSP TOTAL STATIC PRESSURE � THERMOMETER FW FlLTEREOWATER iMV THERMOSTATICM1II%INGVALVE °F DEGREESFAHRENHBT TVP TVPICAL � FLE%IBLECONNECTION c cns uiF uNOEaF�ooa �� PiaEFaNCE 6A GAUGE UIG UNOERGROUVo GAL GALLON UIS UN�ERSLAB � THERMOMETERWELL GALV GALVA�IZED UL 11N�ERbb'RITERSLABORAiORIES.INC. �a� GASVALVE GC GENERALCONTRACTOR VON UNLESSOTHERVJISENOTED GI GREASEINTERCEPTOR � GPD GALLONSPERDAY V VENT � WATERMETER GPH GALLONSPERHOUR VAC VACU01:1 � GPM GALLONSPERMINUTE ViR VENTTHROl1GHR00F Ri GASREGULATOR GRD GROUND W� W�TH �� WALLQEANOOTORCLEAOUTPLUG GW GREASEWASTE WIO WITHOUT � FLOORCLFANOUT H HEIGHT WC WAiERCOWMN FLOORSINK F HD HEAD, HUB DRAIN � ( S) HP HORSEPOWER a FLOORDRAINWITHP�TRAP HVAC HEATING,VENTILATINGBNC HW �OMESTICHOTbVATER HWR DOMESTICHOTINATERRETURN � POINTOFCONNECTION- HYO HYORANT NEWTOEXISTING HZ HERR o-� DRAWINGNOiEREFERENCE 10 INSIOE oIAMETER IE INVERTELEVATION � p PWMBINGFI%iURES IN INCH,INCHE$ INw.c INCHESOFWATERWLUMN�GAS) � GASMAWFOLDLOCATION KEC KITCHENEpUIPMENiCONTRACTOR �I��� OOUBLECHECKBACKFLOWPREVENiER oa LBS.k POUNDS � OOMESTICWATERRISER LP LOW PRESSURE � STl1BUPFORFl1iURE TENANTWNNECTION � SPRMKLERHEAD(SEMI�RECESSED) OO SPRINKLERHEAD(FULLV-RWESSED) Q SPRINKLERHEADNPRIGH� �ALL SYMBOLS SHOWN ARE NOT NECESSARILV USED ON �RAWINGS) HANGER SOPPORT NUT� HEAVY OUTV CLEVIS HANGER.MATERIALTO MATCH PIPE � BUTfSTRIP (TVPICAL) PIPE � POLYISOCVANURATE INSUU+TION BLOCK � � INSTALLED '� 180° RIBBED 10GA. SHIELD SIMILAR RIB (TYPICAL) TOANVILk188 Z.y 12. �2„ 1 PIPE SUPPORT DETAIL 1-112" -12"0 P20 SCALE: NONE HANGERROD LOCKING NUi SUPPORTNUT HEAW DUTV CLEVIS HANGER MATERIALTO MATCH PIPE PIPE � RELEASEO FOR CONSTRl1CTI0N Su6ject to compliance with all regulations of State and Local Codes City of Carniel � y ��m� V"? \oxv�Aln1.T �. 3ULATED PIPE SUPPORT DETAIL NONE COPPER TOP, FINISH AS SELECTED BV ARCH — D,y,`i<'i�T� BRA55 PLUG AS REQUIRED FlTTING OR EXTENSION SANITARYORSTORM J� FINISHED FLOOR FINISHED FLOOR 3 FLOOR CLEANOUT DETAIL P20 SCALE: NONE GREASE INTERCEPTOR EXTENSION WITH PE�ESTRIAN TRAFFIC COVER, INSTALL COVER F W SH WITH FINISHED FLOOR (AS RE�UIRED PoR PROPER INLET WNNWTION) FlNISHEO FLOOR VENT UP IN WALL SEE SANITARV RISER DIAGRAM ON THIS SHEET FOR �ETAILS 4 GREASE INTERCEPTOR DETAIL P2.0 SCALE: NONE PLUMBING FIXTURE AND EQUIPMENT SCHEDULE CONNECTION SIZE TAG FIXTURENPE MFR MODELNo. �ESCRIPTION SAN GW IW VENT 140`HW 110°HW CW FW-1 FW�2 (PRESCALEJ (POSTSCALE) 'LUCERNE" WALL HUNG LAVATORY WITH FAUCET LE�GE FAUCET HOLES ON 4" CENTERS, 8 WALL HANGER. FAUCET SHALL BE MOEN MO�EL 8430, CHROME. 4" CENTERSET, V2' CONNECTIONS AN� LEVER HAN�LE. AMERICAN FURNISHCHROMESTOPS,SOPPLIESANDAI4/4"WHEELCHAIRLAVAiORY LAV-1 LAVATORY(ADA) iq2' . - 1-i12' � 112" 1/2" ' " STAN�ARD 0355At2 DRAINWITHSTAINLESSSTEELGRIDANDP�TRAP. PROTECTTRAPAND SUPPLIES WITH A TRAP WRAP KIT SOOR AS MANUFACTURED BV BROCAR PROOUCTS INC. LAVATORV MOUNTING HEIGHT SHALL BE AS REQUIREO BY THE A �.A. LAVATORY MOONTING HEIGHT SHALL BE AS DETAILED ON ARCHITECTURAL�RAWINGS. CHAMPION PRO RIGHT HEIGHT ELONGAiE� TOILET (ADA HEIGHT�. VITREOUS CHINA, LONI COnSUMPTION 1 b GPF FULLV GLAZEO TRAPWAV. WC4 WATERCLOSET(A�A) 3' - - p� _ _ ��p• _ AMERICAN CHAMPIONPRO ELONGATEDBOWL,BOifOMOUTLETI2"ROUGH-IN,PROVI�ELEFTOR STAN�ARD 211AA.104 RIGHTHAN�FLUSHINGTANNASNEEDE�TOBEONLAVATORVSIOE. CHROME FINISH TRIP LEVER. FLOOR MOONTE� COLOR WHITE. SEAT SHALL BE BEMI5105555C (WHITE�. F54 FLOORSWK SEE SEE SEE . . . JR.SM1IITHIDRN 3IXIOSERIES 8"DEEP1YxiT'WITHBOTTOMDOMESTRAINERNICKELBRONZETOP, PLANS PLANS PLANS Z1901SERIES CASiIRONV2GRATE,ANDOUTLETASREpUIREDBVPIPINGMATERIAL. FURNISH WITH WCO CAST IRON sOOV WITH TRAP PRIMER CONNECTION, FD-1 FLOORDRAIN SEE ���Z, J.RSMITH 2O05 SEOIMENTBUCKET.S"SECUREGRATE,ANDOUTLETASREDUIREDBV PLANS ZURN ZJiSSERIES PIPINGMATERIAL COORDINATE'NRHTHEARCHITECTFORSaUAREOR ROUND NPE TOP. A�JOSTABLE QEANOUT, IF FLOORS ARE TILED OR TERRAZZO PROVIDE FCO FLOORCLEANOUT SEE ZURN 14005ERIE5 WITHEITHERNICKELBRONZEORCHROMEFINISH,IFFLOORSARE PLANS JRSMITH 40005ERIE5 CARPETE�PROVI�EWITHRECESSEOTOP.CLEANOOTSARETOBEFWSH WITH FINISHED FLOOR. COORDINAiE FINISH WITH ARCHITECT. MINI�PRIME BATfERV OPERATED TRAP PRIMING VALVE ANO MAMFOLD. TPV TRAPPRIMERVALVE - - - - - - 112" - - PPPINC MR500-02V INSTALLE�ABOVEFlNISHE�FLOOR,I2VOLTBATfERVOPERATED,V2" FNPTCONNECTION. TMV THERMOSTAiICMI%ING _ _ . 3�4" 3/4" �/4" - - WATTS LFMNV LEAOFREETHERMOSTATICMI%INGVALVE.ASSEIOIOAND101ILISTED. VAWE MININOM FLOW OF 0 5 GPM. OIITLEi TEMPERATURE SET T0110'F. �iTEEL INTERCEPTOR WITH GRAV �UCO COATING INSIOE ANO OUT9DE .\ND FLOW CONTROL FITTING.50 GPM FLOW RATE AN� 100 LB. GI GREASEINTERCEPTOR a' a" - � � - � - - SCHIER G9�50 � INTERCEPTORTOBEFULLRECESSEOWITHTOPOFCOVERFWSHWITH FlNISHED FLOOR AND CARRIES PLUMBING AND �RAINAGE INSTITUTE CERTIFICATE SEAL CONFORMING TO GREASE INTERCEPTOR STAN�ARD PP-G101. GLA55-LINE� WATER HEATER WITH 120 GALLON STORAGE AN� 5 VEAR WARRANTY.ELEMENTSSHALLBE40SkWTOTALINPUT@208v3PHA5E, WH4 WATERHEATER - 1-ll2" 1�VY � 1�VY � � - - AO.SMITH DRE-120-0OS >>Z4FLA,4500WAiTS.UNIiSHALLBECOMPLETELYFACTORYPREWIRE� AND SHALL BE UL LISTED. FURNISH HEATER WIiH APPROPRIATE WATTS RE6ULATOR TEMP AND PRESSURE �TBP) RELIEF VALVE ALONG WITH A VACUUM BREAKER VALVE. 2a' M 2a" X 10' HIGH. MOLOED STONE MOP SINK WITH VINVL BUMPER GOAR�SE]]-AAONALLCURBS. PROVI�EMOPSINKWITH832-AAHOSE MS MOPSINK 3' - - 1-012" il2' - 112' - - FIAT MSB2424 ANDHOSEBRACKETAND889-CCMOPHANGER. FAUCETSHALLBEPART 830-AA WITH BACK SUPPLIES ON 8" CENTERS AND A POLISHED CHROME FlNISH_ ASME RATED THERMAL EXPANSION TANK. WNTRACTOR SHALL MEASURE ET THERMALEXPANSIONTANK - - - - - - - - - AMTROL ST-12C-0� THESVSTEMPRESSOREATPOINTOFINSTALLATIONAN�CHARGEETTO MEASUREO PRESSURE. HOT WATER RECIRCULATION PUMP SCHEDULE MOTORDATA PUMP CHARACTERISTICS TAG SERVICE MFR MODELNo. iVPE NOTESIACCESSORIES FLOW T�TA� VOLTAGE MOTOR MOTOR SOCTION/ (�p� �YNAMIC � � �� SPEED �HP) DISCHARGE IN HEAD(FT) (RPMJ ( � RP4 DOMESTICHOTWATER BELLBGOSSETT PL30B CIRCULATOR iGPM 6.5 2304�60 2650 1112 llT' 13 1. RETURN WATER THERMOSTAT 2. LEAD FREE BRONZE CONSTRUCTION 3. PROVIDE AQUASTAT ABOVE CEILING INSTALLATION'. TRAP PRIMER LOCATE� W CONCFALED ANO ACCESSIBLE LOCATION, NOTE: CEILMG RETURN AIR PLENUMS RE�UIRE NON-PVC UNITS SEE PLANS FORS¢ES r\ 0 NOTES 1 REFERTORECIRWLATIONPUMPSCHEDULEFORADDITIONALWFORMATION. 5 RECIRCULATING PUMP DETAIL P1,0 SCALE: NONE uw�xxcux ELECTRIC WATER 4" HIGH CONCRETE PAD WRHCHAMFEREDE�GES (SEE SCHEDULE) � VACUUM RELIEF VAWE �THERMOMETER � BALL VALVE (TVPICAL) � ASME APPROVED TEMPERATURE AND PRESSURE RELIEF VALVE /RELIEF PIPE FULL / SIZEOF�ISCHARGE OPENMG � DRAIN VALVE �FLOOR DRAIN SEE PLANS FOR LOCATION � FINISHED FLOOR 6 ELECTRIC WATER HEATER DETAIL P2.0 SCALE: NONE PROVI�E 20 X 20 MIN. ACCESS �OOR IN NON-ACCESSIBLE CEILINGS � CONCEAL FEED PIPING WITHIN WALL OR CHASE UNLE55 NOTED OTHERWISE ON PLANS. TVPICAL FOR ALL TRAPS SERVE[ TRANSITION TO BELOW SLAB PIPE MATERIAL AT SIAB ON GRA�E APPLICATIONS TYPE'K'SOFTCOPPERWITHOOTJOINTS OR PE% FOR BELOW SLAB APPLICATIONS FOR ELEVATED FLOOR - SHUT-0FF VALVE (TVP) 112" MIN. cw � pISTRIBUT10N UNIT AS RE�UIRE� FOR SERVING MULTIPLE TRAPS CONNECT TO TRAP PRIMER VALVE AIR GAP FITTING (TVP) � DISTRIBUTION UNIT (TVP) [Nyl�l�lN PROVI�E PROTECTIVE SLEEVE ID 2' MIN ABOVE FLOOR WHERE PASSING THROUGH SLAB ON GRADE � TRAP DETAIL NOTES 1. PROVIDEDISTRIBUTIONUNIT�SJFORSERVINGMULTIPLEFLOOR�RAINTRAPS. 2 E%POSEDUNITINSTALLATIONACCEPTABLEFORROOMSWITHOUTCEILINGS.INSTALL fi6" AFF MINIMUM IN MECHANICAL ROOMS AND 84" AFF IN JANITOR'S CLOSETS. 7 TRAP PRIMER DETAIL P20 SLALE: NONE . • . • CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 �AA'!IN BY', JJC CHECKE� BV: K�H �TES 25760 First Shee� Cleveland, OH 44145 P 444 871 241 � F 440 871 7954 tesengineering com CERTIFICATION pAVID PE110800636; 5TATE OF � O1/31/2020 THIS �RAW ING ANO THE IDEAS, DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THEEXCLUSNEINTELLERUALPROPERTY OF NRRAN ARCHITEQUR& AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PA0.T, WITHOUT THE WRITfEN CONSENT OF NRRAN ARCHITEQURE. O LOGYflILHid019NPPAN�ACHREMflE PRO ECT INFORMATION JAVA HOUSE COFFEE BAR MIDTOWN PLAZ4 CARMEL, IN 46032 PLUMBING SCHEDULES AND DETAILS ISSUE DATE 190410 P 2.0 DATE: 04��9�2� RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i lo•rvalM.T� PLUMBING SPECIFICATIONS I. GENERALPROVISIONS A. 6ENERAL CON�ITIONS. COOES 8 STANDAR�S 1. GENERALCONOITIONSOFTHECONTRACTFOUNDINTHEARCHITECTURAL�RAWINGS,GENERALANDSPECIAL W NDRIONS OF THE AMERICAN INSTITOTE OF ARCHITECTS (AIA) AN� ANY OF THE OWNER'S GENERAL REpUIREMENTS SHALL APPLV UNLESS NOTED OTHERWISE. 2. REFERTOTHEGENERALCONDITIONSONTHEARCHITECTURALDOCUMENTSANDTHEGENERALANDSPECIAL WNDITIONS OF THE AIA FOR ADDITIONAL R WUIREMENTS REGAR�ING; SAFETV. COOROINATION 8 WOPERATION. WORKMANSHIP, PROTECTION, CIITTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARV OPERATIONS, STORAGE,A�JUSTMENTS.CLEANING,ETC. 3. ALLWORKSHALLBEINCONFORMANCEWITHALLLOCALLVENFORCED,FEDERAL,STATE,ANDLOCALCODESAND ORDINANCES INCLU�ING ANV SPECIAL THE OWNER REDUIREMENTS IN AODITION TO TH W E SPEQRED. 4. WNTRACTORSHALLPAVFORAN�OBTAINALLNECESSARVLICENSESPERMITSAN�INSPECTIONSRE�UIRE�TO PROCEE� \NITH THE WORK. THIS SHALL INCLU�E ALL REpl11RE� COOR�INATION WITH THE LOCAL UTILIN COMPANIES AND iHEIR ASSOCIATED FEES OR COSTS. B. SCOPE OF WORK 1. THISCONTRACTSHALLINCLUDETHEFURNISHINGINSTALLING.CONNECTING,ANDOPERATIONOFALLEDUIPMENT WHICH IS A PART OF THE PLUMBING SYSTEMS AS SHOWN ON THE �RAWINGS AND AS RE�UIRED BV SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLE� FOR IN iHE SPECIFICATIONS, BUT WHICH IS 08VIOUSLV NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUOED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UN�ER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVI�E ALL LABOR AND MATERIALS REQUIREO TO PROVI�E THE OWNER A COMPLETE, CO�E APPROVE� AN� OPERATIONAL P W MBING SYSTEM. 2 CAREFULLYREA�SPECIFICATIONFORALLPARTSOFTHEWORKSOASTOBECOMEFAMILIARWITHALLTRA�ES' WORKSCOPE. CONSULTWIiHOTHERTRADEST0INSUREPROPERLOCAT10NSANDAVOIDINTERFERENCES. ANV CONFLICT SHALL BE BROUGHT TO THE ATfENT10N OF THE OWNER BEPoRE WORK IS COMMENCED. 3. WNTRACTORSSHALLBEHELDTOHAVEEXAMMEOTHEPREMISESANDSITESOASTOCOMPARETHEMWITHTHE DRAWINGS AND SPEQFICATIONS, NOTE THE EXISTING CON�ITIONS AN� OTHER WORK THAT WILL BE REpUIRE�. AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL 8E MA�E TO THE CONTRACTOR BV REASON OF iH15 FAI W RE TO HAVE MAOE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALLEXISTINGUTILITVANDPLUMBINGSERVICESSHALLBEFlELOVERIFlED. WRRECTIONSTOTHEDESIGNANO INSTALLATION SHALL BE MA�E WRHOUT A�DITIONAL WST TO THE OWNER. 5. PROVI�EALLCOTTINGAN�PATCHINGREpUIRE�FORINSTALLATIONOFPWMBINGWORKALLCORE�RILLINGOR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FlRE SEALED TO MATCH THE FlRE RATING OF THE FLOOR$ SHAFTS, AN� WALLS PENETRATE�. THIS CONTRACTOR IS RESPONSIBLE TO COOR�INATE ALL WALL AN� FLOOR OPENINGS WITH THE GENERALTRADESCONTRACTOR. THEFINALLOCATIONSAN�SIZESOFALLPIPEOPENINGSSHALLBEPROVI�ED 8Y iH15 CONiRACTOR. 6. ALLWORKWCLUDING,BUTNOTLIMITEDTOPARTS.MATERIALEQUIPMENTANDLABORSHALLBEGUARANTEED FORONEVEARAFTERACCEPTANCEBYTHEENGWEERAN�OWNER. WHEREANEQUIPMENTMANUFACTORER HAS A WARRANTV THAT EXCEEDS ONE VEAR, THAT WARRANiV PERIOD SHALL APPLV TO THIS PROJECT. C.00CUMENTS 1. iHEDRAWING5ARE01AGRAMMAiIC,ALLWORKSHALLBEPERFORMEDASIN0ICATEDONTHEORAWINGSUNLE55 EXISTING CONDITIONS OR COORDINATION ISSUES RE�UIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO A�DITIONAL WSTTOTHEOWNER. 2 ANVINCIDENTALITEMSORLABOR,ETGNOiINCW�EDINTHESPECIFICATI0N50RTHEDRAWINGSBUT REASONABLY IMPLIE� AS NECESSARY FOR THE COMPLETE WSTALLATION OF ALL APPARATUS SHALL BE iNauomc w eio. 3. THE�RAWINGSANDSPECIFlCATIONSAREINTENDEDTOSUPPLEMEMEACHOTHERANOANVMATERIALOR LABOR CALLE� FOR IN ONE SHALL BE FIIRNISHE� EVEN THOOGH NOT MENTIONE� IN BOTH. 4. IF ERRORS ARE FOlIN01N THE ORAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETINEEN THE SAME, OR BETWEEN THE FIGORES ON THE DRAWMGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER ANO SMALLER DRAWINGS.OR IN THE DESCRIPTIVE MATTER ON TNE oRANlINGS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FlNAL DEQSION PRIOR TO THE BID �VE �ATE. 5. THEBI�DINGOFTHISWORNWILLCONTEMPLATETHEUSEOFEaUIPNENTANDMATERIALSEXACTLVA55PEQFIE� HEREIN. WHEREMORETHANONEMANOFACTURERISMENTIONE�ANVONEMAYBEUTILIZE�.SUBSTITIITE MANUFACTURERS MAV 8E OFFEREO ONLY AS AN ALTERNATE TO THE SPECIFIED EpUIPMENT AND MATERWL AND MUST BE SUBMITTE� AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUSITEMSNECESSARYTOCOMPLETETHESYSTEMSCANBEOFANVRECOGNIZE�MANUFACTURE PROVIOE�THESEITEMSMEETMINIMIIMSTAN�ARO5A5SETINTHE5E5PECIFICATI0N5. REFERTOFACHSECTION FOR ANV SPECIFIC REQUIREMENTS. �. COORDINAiION 1. CONTRACTORSHALLLOCATE,I�ENTIFYANDPROTECTANYEXISTINGSERVICESWHICHARERE�UIREDTOBE MAINTAMED OPERATIONAL AND SHALL E%ERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORN TO AVOID DISTURBING SUCH FAQLITIES. ALL W STS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BV THE CONTRACTOR CAUSING THE DAMAGE. 2. EACHCONTRACTORSHALLBEHELDRESPONSIBLEFORALLDAMAGETOOTHERWORKCAUSEDBYHISWORKOR THROUGH THE NEGLECT OF HIS.OR HIS SUB-TRADPS PERSONNEL. ALL PATCHING. REPAIRMG. REPLACEMENT AND PAINTING ETC. SHALL BE �ONE AS OIRECTE� BY THE OWNER BV THE CRAFTSMEN OF THE TRADES INVOLVE�. THE COSTS OF Sl1CH bVORK SHALL BE PAI� BV THE W NTRACTOR CAUSING THE DAMAGE. E METHODS L EXCAVATIONSSHALLBEMADEINOPENTRENCHESFLOORSSHALLBESAWCUT.PIPINGSHALLBELAIOONAN APPROPRIATELV GRADED 6' BED OF CLEAN AND DRY SAND. ENGWEERE� RLL SHALL BE USED TO BACKFlLL TO 6" ABOVE THE PIPING. BACKFILL THE REMAINOER OF THE TRENCH UTILIZING THE E%CAVATED MATERIAL IF APPROVE� BY THE ARCHITECT OR THE OWNER. IF THE EXCAVATE� MATERIALS ARE NOT ACCEPTABLE. ENGINEERE� FlLL ACCEPTABLE TO THE ARCHITECT SHALL 8E UTILIZED TO BACKFlLL THE REMAINOER OF THE TRENCH. BACKFlLLSHALLBEACCOMPLISHEDIN9"LIFTSWITHALLLIRSCOMPACTEDT095%PROCTOR. PATCH FLOOR TO MATCH EXISTING. 2. Epl11PMENT.PIPING.ETGSHALLNOTBE50PPORTEOFROMANYCEILINGS,OTHERPIPING,CONDUITOR �UCTWORK, ROOF �ECK, OR JOIST BRI�GING. ITEMS SHALL BE SUPPORTE� FROM ACCEPTABLE STRUCTURAL BUILOING COMPONENTS AS DETERMWED BV THE ARCHITECT AN� STRUCTURAL ENGINEER. 3. ALLROOFPENETRATIONS.FLASHINGSANDCOUNTERFLASHINGSSHALLBEPERFORMEDBVTHEOWNER'S RW RNG CONTRACTOR AT THE RE�UESTING CONTRACTOR'S COST. F. SIIBMITTALS 1. SHOPDRAWINGSSHALLBEPROVIDE�TOTHEARCHITECiOFALLEpl11PMENTANDACCE550RIE5PROVIDE�FOR THEPROJECTWHETHERSPEQFlEDHEREINOFOnTHEDRAwMGS. REVIEWOFTHESHOPDRAWINGSSHALLeE FOR GENERAL OESIGN CONCEPT AN� ADHERENCE VVITH THE SPECIFlCATIONS. �UANTITV OF SHOP DRAWINGS SUBMITTEDSHALLBEASSPECIFIEDBVTHEARCHITECT. SHOPDRAWINGSSHALLBEPREPARE�BYTHE CONTRACTOR SHOWING LOCATIONS AN� MEASOREMENTS FROM CO W MNS OF ALL CONCEALE� AN� EXPOSE� PIPMG.OUCTWORKCONDUIT,E�UIPMENT.ACCESSORIESETC.AN�SUBMITTEDPRIORTOINSTALLATION. iHE OWNER MAV MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP �RAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE PoR NOT CONRRMING ALL MFORMATION ON THE ORAWINGS PRIOR TO FABRICATION ANDIOR INSTALLATION. 2 PROJECTRECOR�DOCUMENTS-MAINTAINATTHEJOBSITEONECOPVOFALLCONTRACT�OCUMENTSCLEARLV MARKED AS "PROJECT RECORD COPY'. THESE DRAWWGS ARE TO BE MAINTAMED IN GOOo CONOIT10N. UPDATED DAILVPoRCHANGESENCOUNTEREDANDAVAILABLEATALLTIMESFORINSPECTIONBVTHEOwVER. DONOTUSE FOR FlELD CONSTRIICTION! PROJECT RECOR� �OCUMENTS ARE TO BE KEPT CURRENT WITH EXACT �IMENSIONS OFALLWORK,EQUIPMENT,PIPING,VALVES.DUCTWORK,ETC. MARKALLINFORMATIONINRE�LINESAN�NOTES SOASTOBEEASILVIDENTIFIEDFROMTHEBASEDRAWING. UPONCOMPLETIONOFTHEWORK,ONESETOF THESE DOCUMENTS SHALL BE TURNED OVER TO iHE OWNER AS ONE �UALIFICATION FOR FINAL PAYMENi. 3. AFTERTHEBALANqN6AN�ACCEPTANCETESTSARECOMPLETE0AN0ACCEPTEDBVTHEOWNER,THREE W MPLETE SETS OF AS-BOILT DOCUMENTATION SHALL BE PROVIOE�. IT SHALL WCLUDE, BUT NOT BE LIMITEO TO ACCURAiE PLAN DRAWINGS, SYSTEM ANO CONTROL SCHEMATICS, SEpl1ENCE OF OPERATION, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. II. INSULATION A.6ENERAL 1. INSTALLATION SHALL CONFORM TO THE MANUFACTURER'S RECOMMEN�ATIONS, AND IN ACCOROANCE WITH RE WGWZED INDOSTRV PRACiICES. INSTALL INSULATION PER THE MICA MANOAL. 2. CLEANANDORVSIIRFACESPRI0RT01NSULAiING. 3. EMENDINSULATIONWITHOUTIMERRUPTIONTHROUGHWALL&FLOORS.HANGERSANDSIMILARPENETRATIONS. 4. INSOLATION JACKET AND FlTTING COVER MUST BE PLENUM RATED. 5. ITISESSENTIALTHATTHEMTEGRITVOFTHEVAPOR�BARRIERBEMAINTAINED. SFALALLPENETRATIONSOFTHE VAPOR BARRIER BY STAPLES, HANGERS OR WHERE OTHERWISE �AMAGE�. 6. MAINTAINACCESSiOVALVES. 1. PROVIDEREMOVA9LEINSULATIONSECTIONSTOCOVERPORTIONSOFE�UIPMENTTHATMUSTBEOPENE�PoR MAINTENANCE INCLU�E SUCH ITEMS AS FLANGES, PUMPS ANO ACCESSORIES. 8. MSOLATIONSHALLBEBVOWENS-CORNING,KNAUF.ORMANVILLE. B.PLUMBING 1. ALLABOVEGROUN�PIPINGSHALLBEINSULATE�WITHFI9ERGLASSPIPINGINSULATIONWITHANALLSERVICE JAGKET AN� SELF SEALING LAP (ASJISSL). a. WLDWATERPIPING-11NCHTHICN.HOTWATERAN�HOTWATERRETURN-1-012'THICN. b. NON�VERTICAL(INCWDINGELBOWS�RAINWATERLEADERS,OVERFLOWRAINWAiERLEADERS,DRAINAND BODIES � 1 INCH THICK 2 FlTfINGSAN�VALVE55HALLBEIN50LATEDWITHPREMOLOEDFlBERGLA55FlTTINGSANDCOVEREDWITHA PREFORME� PVC RTfING COVER. 3. SEEFI%TURESPECIFICATIONSFORBARRIERFREEREQUIREMENiS. III. PLUMBING A.GENERAL 1. THEENTIREPWMBMGINSTALLATION,MATERIAL$EQUIPMENT,ETGSHALLCONFORMTOTHEREpUIREMENTSOF THE LOCALLY ENFORCE� BUIL�ING CO�E THE INTERNATIONAL P W MBING CODE, AN� THE AMERICAN DISABILITIES ACT G111�ELINES, AN51 Ai' ] 1 REQUIREMENTS FOR iHE PHVSICALLY CHALLENGE� ANO THE UNIFORM FEDERAL ACCESSIeIUTv STANOAROS (UFAS). CONTRACTOR i0 VERIFY ALL PLUMBING ROUGH IN DIMENSIONS MEET THE ABOVE NOTED RW UIREMENTS. VERIFV FINAL ROUGH IN WITH ARCHITECT PRIOR TO BACKFILLING OR WALL INSTALLATION. 2 TESTALLSEWERAN�WATERPIPINGINACCOR�ANCEWITHLOCALCO�ESAN�OR�INANCES. 3. FURNISHACCESSDOORSFORWALLCLEANOUTSAN�VALVESINWALLS. 4 RXTURERTfINGSTHATAREOESIGNEDANDIORINTENDEDTODELNERPOTABLEWATERPoRHUMAN CONSUMPTION SHALL eE THIRD�PARTY TESTEO ANO CERTIFlED FOR NOT EXCEEDING THE MAXIMUM ALLOWABLE LEAD CONTENT, PER THE NSNASNI 81 AN� 3I2 STANDARD. 5. ALLFIXTURESANDEpl11PMENTNOTSPECIFIE�HERE-INAREBEINGPROVI�EOBYOTHERS.THISCONTRACiOR SHALL BE RESPONSIBLE FOR ROUGHING IN ALL SERNCES FOR ALL EQUIPMENT WHETHER PROVIDED BV iH15 CONTRACTOROROTHERS. CONTRACTORSHALLCOORDINATEHISINSTALLATIONWITHTHEAPPROPRIATE WUIPMENT SUPPLIER FOR PROPER ROUGH IN WPoRMATION AND SHALL REVISE THE DESIGV AS RW UIRE� TO MATCH THE EQUIPMENT BEING SUPPLIE�. THIS CONTRACTOR SHALL PROVIDE ALL LABOR AN� MATERIALS REQUIRED TO CONNECT ALL Fl%Tl1RE5 TO THE PW M81NG SYSTEMS INCLUDING BUT NOT LIMITED T0: ALL WATER OR NATURAL GAS CONNECTIONS FROM APPROPRIATE STOP OR VALVE, ALL DIRECT SANITARV CONNECTIONS, ALL INDIRECT WASTE CONNECTIONS TO F100R DRAINS OR SINKS FROM SINKS OR E�UIPMENT. WALK-IN COOLER AND FREEZER COIL CONDENSATE DRAI� PIPING ETC. 6. FlRESTOPPING-REFERTOARCHITECTORAL�RAWINGSFORWALLTVPEAN�l1LCON5TRUCTI0N�E51GN NOMBER FORRATEDMASONRYWALLANDFLOORASSEMBLIES,PROVI�EAULAPPROVED THROUGH�PENETRATION FIRE STOP SYSTEM NUMBER GAJ-11]5. FOR RATED GYPSUM BOARD ASSEMBUES, PROVI�E A UL APPROVED THROUGH-PENETRATION FlRE STOP SYSTEM NUMBER W-L-1003. ]. ACCESS�OORSSHALLBEBVMILCOR,ACU�OR,NVSTROM,LARSEN'SORKARP. B. PIPING 1. PIPEHANGERSFORTHEPLUMBWGSYSTEMSHALLBEADJUSTABLECLEVISHANGERSWIiHAPPROPRIATECLAMP. ALL PIPING SHALL BE SUPPORTED ON A MAXIMUM SPACING OF: a. 6' CENTERS PoR PIPING 3l4" AND SMALLER. b. 8' CENTERS FOR 1"PIPING. c. 10' CENTERS FOR PIPING LARGER THAN 1". d. PIPEHANGERSFORINSULATEDPIPINGSVSTEMSSHALLBESIZEDFORTHEGROSSOUTSIDEDIMENSIONOF THEPIPEANDINSULATION. SEEINSULATIONSPEqRCATIONSFORINSULAT10NRE�UIREMENTS. c. snNiTnavnNovENT 1. ALLPIPINGSHALLPITCHTOIT'SAPPROPRIATEMAINATNOLESSTHANiB"PERFOOTSLOPE.FOR3'ANDLARGER, 11G" PER FOOT FOR T' ANO SMALLER. 2. UNDERGROVN�.SOILWASiEANDVENTPIPINGSHALLBESERVICEWEIGHTCASTIRONHUBANDSPIGOTPIPE WITH COMPRESSION GASKET JOINTS OR SCHE�ULE a0 DWV PVC PIPING AND FlTTINGS WITH SOLVENT WELOED JOINTS. PVC WASTE PIPING SHALL NOT BE USED WITH 140' F WASTE. 3. ABOVEGROUN�,SOIL,WASTEAN�VENTPIPINGSHALLBESERVICEWEIGHTCASTIRONNO-HOBPIPEWITH STAWLE55 STEEL BANDE� JOINiS AND BE HUNG PER CiSP.I. REpl11REMENTS OR SCHE�ULE 40 �WV PVC PIPING AN� FITfINGS WIiH SOLVENi WELDED JOINTS. 1. PVCPIPINGSHALLNOTBEINSTALLE�UNLESSPERMITfEDBVCODEANDSHALLNOTBEINSTALLEDINARETURN AIR CEILING PLENUMS. 2 ALLFIXTURESAN�SANITARY�RAINSSHALLBEVENTE�ASINDICATE�ON�RAWINGSAN�INACCOR�ANCEWRH COOE. 3. ALLGREASYWASTEPIPINGSHALLBESERVICEWEIGHTCASTIRONNO�HUBPIPEWITHSTAINLESSSTEELBANOED JOINTS ANO BE HUNG PER GI.S.P.I. REpUIREMENTS. ALL PIPING SHALL PITCH TO THE GREASE TRAP AT NO LE55 THAN 1/4" PER FOOT SLOPE. D. DOMESTIC WATER 1. CONTRACTORSHALLCOORDINATEWITHTHEBNLDWGOWNERANDTHELOCALWATERCOMPANYFORTHE INSTALLATION OF A NEW WATER SERVICE THIS SHALL INCLUDE THE FEESICOSTS AND INSTALLATION OF A NEW WATER METER AS SHOWN ON THE PLANS AND THE ASSOCIATE� REMOTE READER. THE ENTIRE INSTALLATION SHALLCONFORMTOTHEREpUIREMENTSOFTHELOCALWATERCOMPANV. LOCATEREMOTEREA�ERAT BOILDING OWNER'S AN� WATER COMPANY'S DIRECTION. 2. TESTWATERPIPINGTOHYDROSTATICPRESSUREOF100PSIG.FORTWOHOURS. STERILIZEALLDOMESTIC WATER PIPIN6IN ACCOR�ANCE WITH A W.W.A. STANDARDS. 3. IIN�ERGROUN� WATER PIPING 2-V2" AN� LARGER, SHALL BE �UCTILE-IRON PIPE AN� FITTINGS CONFORMING TO ANSI A2L51 A�D AWWA G11� RIIBBER GASKET JOINT3. 4. IIN�ERGROl1N� WATER PIPING T' AN� SMALLER, SHALL BE TYPE'K" SOFi COPPER T08E OR HARD DRAWN PIPE WITH SILVER BRAZED JOINTS (SILF0515�. 5. ABOVEGROUNDWATERPIPING,3'ANDSMALLER,SHALLBETVPE"L"HARDDRAWNCOPPERPIPEWITHWROUGHT COPPERFITTINGSAN�955SOL�ERE�JOINTS. ASANALTERNATETHECONTRACTORMAVOTILIZECOPPER PRESS FITTINGS (PROPRE55 SYSTEM) AS MANUFACTURE� BY VIEGA. FITTINGS SHALL CONFORM TO THE MATERIAL AN� SIZING REQUIREMENTS OF ASME B16.18 OR ASME Bi6 22 0-RWGS FOR FITTINGS SHALL 8E EDPM. INSTALLATION OF RTfINGS SHALL CONPoRM TO CO�E AN� THE MANUFACTURER'S SPEQFlCATIONS/RE�UIREMENTS. WATERPIPINGJOINTS9EiWEEN�IFFERENTMATERIALSSHALLBEPERTHE LOCALLV ENFORCEO P W MBING CODE SECTION 60522. 6. WATERPIPINGBELOWCONCRETEFLOORSSHALLBETVPE"K"SOFTCOPPERTUBE,CONTINUOUSWITHOUT SPLICES OR FITTINGS AND SHALL BE COVERED WITH SAND SO THAT PIPING WILL NOT BE EMBEDOED IN THE CONCRETE. ]. DOMESTICWATERVALVESSHALLBEASFOLLOWS: a 2'ANDSMALLERSHALLBEMILWAUKEEVALVEkBA-1000R%BA-i50BALLVALVE b. 2-V2' AND IARGER SHALL 8E MILWAUKEE VALVE #F2886 GATE VALVE. A. LABELING A.SUMMARV 1. SECTIONINCLU�ESNAMEPLATES.TAGS.AN�PIPEMARKERS. B. REFERENCES 1. ASMEA13.1�AMERICANSOCIETVOFMECHANICALENGINEERS��SCHEMEFORTHEIDENTIFICATIONOFPIPING SVSTEMS C.NAMEPLATES 1. PRO�l1CT�ESCRIPTION'.LAMINATE�THREELAYERPLASTICWITHENGRAVE�BIACKLETTER50NLIGHT WNTRASTING BACKGROON� COLOR. D TAGS 1. METALTAGS�. a. BRASSWITHSTAMPE�LETfERS:TAG5IZEMINIMUMI-1121NCHESDIAMETER. 2. INFORMATION TAGS'. a. CLFARPlASTICWITHPRINTE�'DANGERf"CAUTION°OR"WARNING"AN�MESSAGE',SIZE31/4%5-SBINCHES WITH GROMMET AND SELFLOCKING NVLON TIES. 3. TAGCHART:TYPEWRITTENLETfERSIZELISTOFAPPLIEDTAGSAN�LOCATIONINAN001ZEDALUMINUMFRAME. E PIPE MARKERS 1. WLORANOLETTERING:CONFORMTOASMEAI3]. 2. PLASiICPIPEMARKERS: a. FACTORYFABRICATEqFLEXIBLE,SEMI-RIGIDPLASTIGPREFORMEDTOFIiAROUN�PIPEORPIPECOVERMG. LARGER SIZES MAY HAVE MAXIMUM SHEET SRE WITH SPRING FASTENER. IaC1:1aF 1. DESCRIPTION:POLYESTERORLAMINATEDMVLAR,SIZE19%015WCHES.A�HESIVEBACKEDWITHPRINTED IDENTIRCATION. 2. CONTRACTORTOPROVIDELABELSATFACHENTRANCE�OORTOCHILLERROOM-"DONOTENTERROOMWHEN BFACONISFLASHING" G.PREPARATION 1. DEGREASEANDQEANSURFACESTORECENEA�HESIVEFORIDENTIFlCATIONMATERIALS. H.INSTALLATION 1. INSTALL I�ENTIFVING �EVICES AFTER COMPLETION OF COVERINGS AND PAINTING. 2 INSTALL PLASTIC NAMEPlATES WRH CORROSIVE-RESISTANT MECHANICAL FASiENERS, OR ADHESIVE. 3. INSTALL LABELS WITH SUFFIQENT ADHESNE TO ENSURE PERMANENT ADHESION AND SEAL WITH CLEAR LAC�UER FOR UNFlNISHEO CANVAS COVERING APPLV PAINT PRIMER BEFORE APPLVING LABELS. 4. INSTALL TAGS USING CORROSION RESISTANT CHAIN. NIIMBER TAGS W NSECUTIVELV BY LOCATION. 5. IDENTIFV EQUIPMENT WITH PLASTIC NAMEPLATES. 6. IDENiIFV CONTROL PANELS ANO MAJOR CONTROL COMPONEMS OUTSI�E PANELS WITH PLASTIC NAMEPLATES. z IDENTIFVVALVESINMAINANDBRANCHPIPINGWITHTAGS. e. TAGAUTOMATICCONTROLS,INSTRUMENTS,ANDRELAVS.KEVTOCONTROLSCHEMATIC. 9. IDENTIFV PIPINfi CONCEALEO OR EXPOSED, WITH PLASTIC PIPE MARKERS, PLASTIC TAPE PIPE MARKERS OR STENCILEO PAINTING. I�ENTIFV SERVICE. FLOW �IRECTION, ANO PRESSURE. INSTALL IN CLFAR VIEW AN� ALIGN WITH A%IS OF PIPING. LOCATE I�ENTIFICATION NOT TO E%CEED 20 FEET ON STRAIGHT RUNS INCLUDWG RISERS AND DROPS, ADJACENT TO EACH VALVE AND TEE. AT EACH SIDE OF PENETRAiION OF SiRUCTURE OR ENCLOSURE AN� AT EACH OBSTRUCTION. ' • . . CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317.288.0753 oPAeIN BV�. JJC CHECKED BV: K�H �TES 25760 First Sheet Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 tesengineering.com CERTIFICATION pAVID PE110800636; 5TATE OF O1/31/2020 THIS DRAWING AND THE IDEAS. DESIGNS AND CONCEPTS CONTAWED HEREIN ARE THEEXCLUSNEINTELLERUALPROPERTY OF NRRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, wHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF NRRAN ARCHITEQURE. O LOPMILHiE019NPflAN�0.(HfIEMPE PRO ECT INFORMATION JAVA HOUSE COFFEE BAR MIDTOWN PLAZ4 CARMEL, IN 46032 PLUMBING SPECIFICATIONS ISSUE DATE 190410 P3.0 DATE: 04�09�20