REFLECTED CEILING PLAN
SCALE 3/16" = 1'-0"
❑�
N
�
REFER TO MEP PLANS FOR FINAL
ELECTRICAL FIXTURE LAYOUT AND
SPECIFICATIONS.
`
MITSCH
D E S I G N
200 S. Rangeline Ftl. I Sui�e 226
Carmel, Inaiana 46032
31 ZSI32222
wwrv. mi�schtlesign.com
�
BUCKINGHAM
W
Q
�
�'^
V i
I..L
O
LL
/
O^
V
��
�
�.J
,
�
�
1�
II
�
�
�
�
� � N
Z M
2 � �
V
Z"�Z
LL J
Y w w
V � �
� N �
m � U
� �� l.�
� �✓ ✓
: "+. l
�7 . .Z.
�x ' AR19900150 i + �
EP6, �ESIGNS PIJo YLAN6 �ORIGINPL WORK60F
NViXOFSXIp Fl%EO IN P TANGIBLE ME�IVFI OF E%PRESSION�
N�ICAiE� OR PFESEMED Bv }HESE DRAYVINGS AIJO
PEWVOF
MIi9CX �ESIGN. P LRIGXTS RESERVE�. IXOEPT FOR U54
EURE69LV GERMIREO IN W RIiINO.
REFLECTED CEILING
PLAN (LOCATION
REFERENCE ONLY)
A201
III
9CI
YC
Y3
$o
NOT IN CONTRACT
DENOTES NEW 2k2' ACOUSTICAL CEILING GRIO/TILE
DENOTES GVP BOARO CEILING
DENOTES NEW EMERGENCY EXIT SIGN
DENOTES LIGHTSWITCH
DENOTES THREE-WAY LIGHT SW ITCH
DENOTES LIGHT SW ITCH W ITH �IMMER
NOTES
E" DENOTES EXISTING TO REMAIN
'R"DENOTESRELOCATE�
'D" DENOTES DEMOLITION. SAVE FOR RELOCATION AS REQUIRED.
NOTE: ALL LIGHTING AND MECHANICAL ITEMS FOR LOCATION PURPOSES ONLV. REFER TO ENGWEERING
DRAWINGS FOR MORE INFORMATION.
GENERAL REFLECTED CEILING PLAN NOTES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
a.
P.
Q.
R.
5.
�
U.
V.
PROVI�E RRE DAMPERS AT FIRERATED PARTITIONS AS REpl11RED PERAPPLICABLE BWL�ING CODES.
CEILING IN ALL AREAS SHALL BE MSTALLED IN STRICTACCORDANCE WITH MANUFACTURER'S
SPECIRCATIONS, ANO ALLAPPLICABLE BUIL�ING CODES.
MECHANICAL CONTRACTOR SHALL BE RESPONSBLE FOR ALL Dl1CTW ORK. SUPPLV AND RETl1RN AIR AND
THERMOSTATS. COORDINATE ALL ELEMENTS OF THE HVAC SVSTEM TO PROVIOE A COMPLETELY
BALANCED AND EFFIQENT HEATING AND CWLING SVSTEM.
HVAC THERMOSTAT CONTROL FOR ALL ROOMS SHALL BE LOCATED W ITHIN DEMISED SUITE. VERIFV AN�
REWORK EXISTING DUCTWORK AND THERMOSTATS AS RE�UIRED.
MECHANICAL CONTRACTOR SHALL VERIFV WORKING CONDITION OF ALL EXITING THERMOSTATS, VAV
BOXES, EXHAUST FANS, AN� ANV OTHER DEVICE DIRECTLV RELATEO TO THE HVAC SVSTEM.
CONTRACTOR TO NOTIFY ENGWEERIDESIGNER IMMEDIATELV UPON oISCOVERV OF DEFECTIVE DEVICE.
PAINT NEW GYPSUM BOARD BULKHEADS CEILING W HITE, UNLE55 OTHERW ISE NOTED.
REMOVEEXISTINGSWITCHESTHATARENOTRE-USED. REMOVECON�l11TANDWIRING6ACKT0
NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.
THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING HEIGHTS
AND CEILING PLENUM CONDITIONS FOR CLFARANCE OF DUCTWORK, LIGHTING, ANO OTHER
OBSTRUCTIONSTOASSURETHEFINISHEDCEILMGHEIGHTIN�ICATED. ANVDISCREPANCVSHALLBE
BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANV W ORK.
CEILING HEIGHTTHROIIGHOUTTHE SPACE IS EXISTING TO REMAIN, UNLESS NOTED OTHERWISE.
EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERW ISE. CONTRACTOR
TO REMOVE AND REPLACE ANV EXISTING CEILING TILES AN� CEILING GRID THAT IS BftOKEN. CHIPPED,
OR PUNCTl1RED W ITH NEW TO MATCH EXISTING.
ALL NEW SW ITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF
SWITCH 6"-9" FROM EDGE OF DOOR FRAME. UNLESS NOTED OTHERWISE.
EXIT SIGNS, DOW N LIGHTS, SPRINKLER HEADS, ETG SHALL BE CENTERED W ITHIN TILE, UNLE55 NOTE�
OTHERWISE.
COLOR OF LIGHT SW ITCH DEVICES AND COVERPLATE TO BE BUILDWG STANDARD, UNLESS NOTED
OTHERWISE.
ALL MULTIPLE SW ITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED W ITH A SINGLE �EVICE
COVERPLATE.
REFERTO ENGINEERING DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT
SIGNAGE, LIFE SAFETY SVSTEMS, 24 EMERGENCV LIGHTING, VENTILATIONS, HVAC SVSTEMS, CIRCUITING
OF LIGHTS AND THERMOSTAT LOCATION ETC.
THERMOSTATS SHALL BE LOCATED ADJACENT TO LIGHT SW ITCH AND W ITHIN REACH RANGES OUTLMED
IN AN51 A11I.b2009 SECTION 308 AND 309. ALL THERMOSTAT POSITIONS AND LOCATIONS TO BE
COORDINATED WITH THE DESIGNER BEFORE PLACEMENT.
SUPPLV AND RETURN AIR GRILLES ARE TO BE RUSH WITH NEW CEILING TILES AND ARE TO BE W HITE IN
COLOR. REFER TO ENGINEERING �OCUMENTS FOR AD�ITIONAL INFORMATION.
ALL DIMENSIONS ARE TO THE CENTERLINE OF FIMTURE, UNLESS NOTED OTHERW ISE.
IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED W ITH THE DESIGNER
PRIOR TO W STALLATION.
VERIF`FAILSPRINKLER-kIEADLOChTJBN$. NOTIFV.HE6lGNERIFAD}V-HISCREPANGIES,OCCUR ��
AND PATCH M,NV SCARRINGICREATED BV REMOVAL OF EXISTING WALLS.
CONTRACTOR TO MAINTAIN COMPLIANT ATTIC ACCESS IN WORK ROOM.
0 REFLECTED CEILING PLAN KEYNOTES
1. FAUX WOOD BEAMS. REFER T02IA201 FOR MORE INFORMATION.
2. EXISTING SLOPE� CEILING TO REMAIN.
3. 2X8 WOOD BEAMS.
4. 2X W OOD STUDS AT ifi" O.C.
5. V2" PLWVOOD FACED VENEER. REFER TO TO FINISH SCHEOULE FOR STAIN.
6. REPAINT CEILING TRIM IN THIS LOCATION. REFER TO RNISH SCHEDULE FOR COLOR SELECTION.
�. PATCH AND REPAIR CEILING AS NEEDED.
8. FlLL IN ARCH AT ENTRV. ATTACH NEW BULKHEAD STRUCTURE TO EXSTING ARCH STRUCTURE.
9. CONTRACTOR TO LEVEL OUT CEILING IN THIS LOCATION.
ALTERNATES:
1. DEMOLISH ALL EXISTMG POPCORNMG ON CEILING AND REFlNISH W ITH PAINT. REFER TO FlNISH
SCHEDULE FOR MORE INFORMATION.