Loading...
HomeMy WebLinkAboutG001RELEA5E0 FOR CONSTRIICTI�N Su6jec� �o compliance with all regula�ions of S�a�e antl Local Codes City of Carmel r �un��\i�lo.va�M��_ onrE: 04/14/20 1 LI FE SAFETY PLAN SCALE: 3/16" = 1'-0" 0 N ` MITSCH D E S I G N 200 S. Rangeline Ftl. I Sui�e 226 Carmel, Inaiana 46032 31Z5I32222 wwrv. mi�schtlesign.com � BUCKINGHAM W LL � � � � � 1..� C � L � M �o v�� w � Z � Z > j Y w w Orn O � c�v Q V � m � U `�° �'��9�� , �_ ,l_:. .� •.' `': z; �:�x ' AR19900150 � + e u� mees. oesiaias nrvo>vws �oeiewu woers ov n�*HoaswP rixeo w n�arvsie�e weoi�rn or exPRessow iNoicarEo oa aaEsenreo ev.Hese oaawinas ntio R.v ar MIi6CX �ESIGN. P LRIGXTS RESERVEP IXCEPT FOR p5E6 E%PREBSLYPERMIREOINWWiiNG. LIFE SAFETY PLAN & CODE INFORMATION �oo� LIFE SAFETY LEGEND NOT IN CONTRACT 0 FE CABINET OR WALL MOUNTED FIRE EXTINGUISHER � DENOTES DIRECTION OF EGRESS TO EXIT/E%IT DISCHARGE � DENOTESA3MET)OCWPANCVTVPE � DENOTESBOCCUPANCVTVPE � DENOTES A-3 (GRO55) OCCUPANCV TYPE NOTE: COORDINATE FINAL FIRE EMTINGUISHER LOCATIONS WITH LOCAL FlRE CMEF AS REQUIRED. NOTE REFER TO RERECTED CEILING PLAN AND OR ELECTRICAL ENGWEER DRAW INGS FOR ALL EMERGENCV AND EXIT LIGHT LOCATIONS. CODE ANALYSIS DESCRIPTION RENOVATION PROPOSED USE OF FACILITV LEASING OFFICE BUILDMG CONSTRUCTION TVPE VB (TABLE 503) OCCl1PANCVCLASSIFICATION(S) B(A3ACCESSORV;R-2ACCESSORV)(CH.3)OCCUPANCV E%ISTING TO REMAIN UNCHANGED. OCCUPANCVSEPARATIONSREOUIRED NOTREQUIRED(TABLE508.4) TOTAL OCCUPANTS PER LOAD FACTORS B(OFFlCE) (TABLE 1004.1 2) 2386 SF I 1�0 SF PER OCC FACTOR = 24 OCCUPANTS A-3 (NET) (TABLE 1004.1 2) 698SF/ i55FPEROCCFACTOR=4]OCCUPANTS A-3 (GROSS) (TABLE 1004L2) 655SF/ SOSFPEROCCFACTOR=140CCUPANTS TOTAL=850CCUPANTS ACTUAL BLDG HEIGHT 1 STORY (TABLE 503) AUTOMATIC SPRWKLER SYSTEM NOT REQUIRED (SECT 903) PORTABLERREEXTMGUISHERS MAXTRAVELDISTANCETOEXTINGUISHER=]S(TABLE9063) FIRE ALARM SVSTEM NOT REQUIRED (SECT 90]) SMOKE DETECTION NOT REQUIRED (SECT 90]) COMMON PATH OF EGRESS TRAVEL 75 FEET (TABLE 10143) EXIT ACCE55 TRAVEL DISTANCE 20� FEET (TABLE 10162) CORRIDOR FIRE-RESISTANCE RATING NOT REQUIRED (TABLE 1018.1) FIRE-RATED STORAGE ROOM OVER 100 SF NOT REQUIRED (TABLE 5084) ENCLOSED EXIT ACCESS STAIR NOT REQUIRED (SECT 1009) DEAD EN� CORRIDOR MAX 20 FEET (SECT 1018.4) MINCORRIDORWIDTH 441NCHE5(TABLE10182) MIN/MAXDOORWIDTH 32/48WCHE5(SECT10�8.1.1) DOORS EGRESS DOOR MUST SWING TOWARDS EGRESS WHEN SERVING 50 OR MORE OCCUPANTS. MANUALLV OPERATED SLIDING DOORS ONLV PERMITTED FROM OCC LOAD SPACES OF 10 OR LESS (SECT 1008.L2) E%ITS REQUIRE�/PROVIDE� 2/4 (TABLE 1021 2) VARIANCE(S) NOT REQUIRED APPLICABLE BUILDING CODES CODE OESCRIPTION COMPRISEDOF GENERALA�MINISTRATIONRULES GENERALADMINISTRATIONRULES 'fi�51AC12 (ENTIREDOCl1MENT) (GAR)(UP�ATED08012014) (AMENDE�12D12014) BUILDING CODE 20141NDIANA BUILOING CODE ' 2012 MTERNATIONAL (INDIANAAMENDMENTS) (IBC)-EFFECTIVE12A12014 BUILDINGCODE ' 6�5 IAC 13-2.6 FIRE CODE 2014 INDIANA FIRE CODE (IFC) - ' 2012 MTERNATIONAL FIRE CODE (INDIANAAMENDMENTS) EFFECTIVE12.012014 '6751AC22-25 PLUMBINGCODE 20121NDIANAPLUMBINGCODE `20061NTERNATIONALPLUMBMG QNDIANAAMENDMENTS) (IPC)-EFFECTNE12242012 CODE ' 6]SIACi6-14 ELECTRICAL CODE 2009 INDIANA ELECTRICAL ' 2008 NFPA ]0 QNDIANAAMENDMENTS) CODE(IEC)-EFFECTIVE08262009 '6�SIAC1]48 MECHANICALCODE 20141NDIANAMECHANICAL '20121NTERNATIONAL QNDIANAAMENDMENTS) CODE(IMC)-EFFECTIVE12.012014 MECHANICALCODE ' 6]5 IAC 18-0.6 HANDICAPACCESSIBILITVCODE 2014INDIANABUILDWGCODE '6751AC13-2.642CHAPTERII QNDIANAAMEN�MENTS) CHAPTERII-ACCESSIBILITV 'A11I.1ACCESSIBLEANDUSABLE BUILDINGS AND FACILITIES, 2009 EDITION ENERGVCODE 20101NDIANAENERGV 'ASHRAE90.1200] (INDIANA AMENDMENTS) CONSERVATION CODE QECC) - ' 615 IAC 19.3 EFFECTNE05.0]2010 ROOM SCHEDULE NUMBER NAME Area