Loading...
HomeMy WebLinkAboutS-204G - GARAGE - FOURTH FLOOR FRAMING PLANA 8" #5 AT 24" O.C. #9 LADDER TVPE JT REINF. AT 16" O.C., AND BOND BEAM B 8" #5AT3P'O.C. #9LIADDE)RTVPE�REINFNATS6NQCAANDIBONDBIEAM W ITH (2) #5 AT T/WALL AND AS INDICATED IN DETAILS NOTES: 1. REINFORCEALLWALLSASINDICATEDINSCHEDULEE%CEPTASNOTESONPLANSANDIOR DETAILS. 1 �• 2 PROVIDE A 1'-0" HOOK AT TOP OF ALL VERTICAL BARS.� 3'-0" MIN. 1 —r — — K (J.5, �_i/ I 21• �• 21• �• F� � F� � 130'-S' ` �30'-S' d d � 130'-5' J �H.6i H � .....� , �_,. ...� s�-�r� � �a.��. � 24 0' 3 . �� 13P 5" .. 128'-11 S18•' mld mld � 130•5•' —I PBOS —129 6 V2 ,...... '2 ... _ — �— _ — _ — _ — . _ _ _ _ O FD � I $-603G' m a 130'-5' � m d 5 1/4"- ! 2.6 � _ �2.7� `� — — — 3 3.1 RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes CityofCarmel TH FLOOR FRAMING PLAN �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 mld G; —F; � E; D; C; \.B, . � ' •, � ' �._� . � ' �' ,_� � 24• 0•' � 24• 0•' � 24• 0•' � 24• 0•' � 24• 0•' � I 5 I I I I I �I '�5-603 �I �I �I �I �I I�� 12�'-6 i18•' d 6" PT SLAB I, 128'-41/8•' I,� 126'-105/8•' mld � MBO] .. 126'-0 3l� , 125'-51/4•' mld MBO] � �34'-9 i14•' I, 134'-13/4•' MBO] ... 133'3 �/8•' I, 13Y-83/8•' mld I�� 131'-10318" m d 6" PT SLAB I, 131'-2 ]/8•' A.5 A.3 .A. ; ��� _ 25• �• 6• 4• 1�• B• �-F� �-F� �i � 130'-S' �30'-5' 130'-S' d ;: 129'-6 VP' PB03 I 130•5•' Q • • � �30'-3 VY� F D_ � �30'-0�/2" FD .. �29'-6VY' � �30'-0�/2" � �30'-0�/2" FD. . �30'-OVY' �I � � 2.. I�' 129'-6 VT' . l603G l m ll I a I I 6' PT SLAB I� m I� m I� m I� m I� m I� m I� m COLUMN J-2] a I � � � � � � CENTERLME � � � 130'-5" — � 130•5•' I'MB01 -- I: 130•5•' I I I I _ — _ — _ — _ — _ L _ — _ — _ — _ — _ I _ I _ — � _ _ — _ _ — _ — _ — i _ _ — _ — _ — _ _ — _ — _ — _ — _ _ — _ — _ — _ — _ I — _ — _ — _ — _ — r — — _ — _ — _ — I _ — _ — _ — _ — _ I S 603 � p - ^ 130'-5 '� 130 5 T 3' 9" SLAB m I 603G � II I'� ;�� i li i li li li i -603G'� � o II � '• I + I II I I I I ` °�.. ' ......,. a � . . .. g . � -603 i m m � �0 8-3�� � TVP �; �� ..� � � Y �� � � 130, 5•' � � 130• 5•' � � 130• 5•' � � � 130• 5•' � i 130, 5•' � � � . 130• 5•' 130• 5•' � B03(13Y�-�]' MB (131'-]) MB 8(131:� ") MBO� MB07 MBO� MBO] Mg �' I I I � s I I I I I I �I �I �I �03G �I I I 5 I I 3 I I � �03G' �03G' � �� ,...5..... 130'-5" J...— 9-..... —_ —_—_ _— � ` 603 i � " m ' � � (130 5 ) � � _ — _ — _ — _ — _ — _ — _ — s 604G �' FOURTH FLOOR FRAMING PLAN NOTES O INDICATES NOTE REFERENCED IN PLAN 1. SEEGENERALSTRUCTURALNOTES(5100)ANDTVPICAL POST TENSION DETAILS (5500 SERIES) FOR ADDITIONAL INFORMATION. 2. VERIFYALLDIMENSIONSWITHTHEARCHITECTURAL DRAWINGS. 3. SEETHEPOST-TENSIONINGANDMILDREMFORQNGPLAN FOR POST-TENSIONED SLAB REINFORCING REQUIREMENTS. 4. CONTRACTOR IS RESPONSBLE FOR THE DESIGN AND STAGING OF ALL SHORING AND RE-SHORING. 5. STRUCTURALSLABTHICKNESSESANDTOPOF STRUCTURAL SLAB ARE AS SHOW N ON PLAN. TOP OF SLAB ELEVATIONS DO NOT INCLUDE CONCRETE WASH. 6. CONTRACTORTOCOORDINATEEMBEDPLATESREQUIRED FOR STAIRS, GUARDRAILS, WALLS, CLADDING SUPPORT, ETC. O STEEL PAN STAIRSAND LANDINGS, STEEL RAILINGS, AND CONNECTIONS TO THE Sl1PPORTING CONCRETE FRAMING SHALL BE BIDDER-0ESIGNED, UNO. APPLICABLE DESIGN REpUIREMENTSPERSTRUCTURALGENERALNOTES. CON NECTIONS SHALL 11TILIZE EMBED PLATES TO AVOID POST-INSTALLED ANCHORS INTO THE POST-TENSIONED BEAMS AN D SLABS. e. CONTRACTOR IS RESPONSIBLE FOR ENSURMG THAT POSITIVE DRAINAGE IS PROVIDED TO FLOOR DRAINS IN THE POST-TENSIONED SLAB. 9. CONTRACTOR IS RESPONSIBLE FOR ENSURING THATA MINIMl1M CLEARANCE OF ]'-Y' IS MAINTAINED BELOW THE FOURTH FLOOR FRAMMG 10. THE SHADED REGION INDICATES REQUIRED LOCATION OF CONCRETE WASH. 1 L(X 1 DENOTES MASONRV WALL TVPE, SEE SCHEDULE. FIFTH FLOOR EL. 140'a" Fo�Rr� F�ooF E� ,3o.s. rHiao F�ooa E�. ixo�.3. sEcoNOF�ooi E� ,,o.,. SLAB ON GFAC EL.98' 9" ISOMETRIC - LOOKW G EAST ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Structural Engineer CE Solutions, Inc. 10 Shoshone Drive Carmel, IN 46032 317324-6024 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority W ay S. Dr. #204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE O6/21/19 ar„� "q w�q pa`ZNE ...: 'Np 'h a'p1 ��ys'tq'F;.99'"'; `�r.:P 0�9<� ? PEl150IXN`i$ 1 - %?.�v 8Tq1tOF f.M1'3 SHEETISSUE 1 Issued for C r�, RAT I O WWNGHIPOIIGEIHI6PPGHIIEGIOWILPPDEVGIPEHUPGdU\NIPGI6GIVEVIPLtlPFlD&@ OSE CISSEIAINdiION OP W PI�ICdiION I� P BE WCE1uRH00i PPIOP�uPi iEN CMSENi OF PAi�pR PLLLtlAIAION U\N WGH50F W Pv1UGHlPN�OMEI\NI6ErWEHENEBv WEqFlGLLYRE5ER4EC. PROJECT NO. 18087.001 SHEET TITLE GARAGE-FOURTH FLOOR FRAMING PLAN SHEETNUMBER S-204G