HomeMy WebLinkAboutS-204GPT-GARAGE-FOURTH-FLOOR-POST-TENSION--MILD-REINFORCING-PLANCONCRETE COVER SCHEDULE SYMBOLS MEMBER MIN.TOP MIN.BOTTOM MIN.SIDE COVER COVER COVER MARK DESCRIPTION FOOTMGS 2" 3" 3" SPAN INDICATOR (INDICATES EXTENTS SLABS 2" 1" 1112" ..---�-'---- OFFRAMINGMEMBERSOROTHER BEAMS 2" 11/2" 11/2" STRUCTURALCOMPONENTS) COLUMNS 2" NA 2" WALLS 2" NA 2•' f� POST-TENSION STRESSING END (PLAN) j i POST-TENSION DEAD END (PLAN) POST4ENSION PRORLE (PLAN) p ��p (IN INCHES, BBLAB TO C.G.S.) 1]5k �� EFFECTNE POST-TENSIONING FORCE AFTER ALL LOSSES; 1]5 kips � K J.5� �J �H.6i ��H G I i I i I i / / \ _�i �• _�i \ �i ._�i � , • � , T _—_�_—_— �_—_—_—_—_�_—_ — — — 1 ---- =--- �----T �..� I I I I � � � � III I I r y' II #4x1YAT1Y'O.G(T) i i ¢ � �\ I I I � ,sow�� i F I �3 L25 3]5 2 I3]5 I L25 I3]5 L25 I3]5 L25 3]5 �. .. 1 f � � � #4x6' AT 8"OG. (T) #4xi 6' AT i 6"O.C. (T) #4Ix10' AT i 6"O.CI� (T) #4Ix10' AT i 6"O.C. (T) #4Ix10' AT i 6"O.C. (T) #4Ix10' � -� I y� -� y� i � � i 'I � i 'I � i 'I � i 'I #4x22' AT 16"OA- (B) #4x10' AT 16"OA- (6) �#4x10' AT 16"OA- (6 #4x10' AT 16"OA- (B #4x10' AT 16"OA- (6 h � Q m r � ` Z (� U �� O U I � � ¢ N `' o 2 , - - - - - _ - - � � ' #4x22' AT i 6"OD_ (B) ,6 iw�� - I =� � � � S I �I I S I S U I O I I I I Q I 'u _ _ _ _ � _ _��_ _ _��_ _ _ _ _���_ _ �r� I � � !1 (DII V►�r � tl I U w #4x10'ATi6"OL.�(B) �#4x10'ATi6"OL.(B�) �i � �i � � � � � i � I I � I -� � E� �� D� �� C� �� B� f A.5 � A.3 � A' li .. �. �.; �_. ..._i � � � — — — — — — �, r �� - — -�- 5--�-� — — — —± � — — —c — --� — — — — — — — � (3) #6 CONT. i �� oj� -z 534kAdd'I.WITHIN a? o DIAPHRAGM BARS 3'-0" OF SLAB EDGE � I I � i wpw i i i� i �m� � � � � � #4xiTATiT'O.C� � � I� I� I� � I+ ,sow�� ,.25 I3.,5 ,.25 I3.,5 ,.25 I3.,5 ,.25 I3.,5 � ,.25 3.,5 225 3 f' f' f' f' f � i 6"O.C. (T) #4Ix10' AT i 6"O.C. (T) #4Ix10' AT i 6"O.C. (T) #4Ix10' AT i 6"O.C. (T) #4Ix10' AT i 6"O.C. (T) #4x23' AT 8"O.C. (T) ' -� y� -� y� � i'I � i'I � i'I � i'I � i #4x10'AT16"OA-(Bj #4x10'AT16"OA-(Bj #4x10'AT16"OA-(Bj #4x10'AT16"OA-(Bj #4x11'AT16"OA-(B) #4x18'AT16"pA-(B) - � � � � m S � I S I S I S I S Q _ � m Q I I I I U �� � �¢ �I I (3) #6 CONT. � 3'-0' OF SLAB �EDGE � a � � DIAPHRAGM BARS i �� N � � - — — � — — — — `I,— `s�=�-�; — — -- I—J— — � — — — — � —» —�------— (3) #6 CONT. �� ( m I I DIAPHRAGM BARS I 534 kAdd'I. WITHIN 3'-0" OF SLAB EDGE O � I I I I Q il il il il #4x18' AT i6"OL. (B) � � � � � -3 ,.25 3.,5 2 � 3.,5 � ,.25 � 3.,5 ,.25 � 3.,5 ,.25 � 3.,5 ,.25 � 3.,5 ,.25 � 3.,5 ,.25 � 3.,5 ,.25 � 3.,5 ,.25 3.,5 225 3 - 1 � I � I � I � I � I � I � I � I � #4x6' AT 8"O C. (T) #4xi 6' AT i 6"O.C. (T) #4x10' AT i 6"O.Q (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x10' AT i 6"O.C. (T) #4x23' AT 8"O.C. (T) �- -� I y� -� -� -� -� -� -� i2.7. - -------- � ��__� —_�_ #4x10'AT16'0.�.(el�__ . #4x10'AT16"O.G(t----#4x10'AT16"O.0 g)----#4x10'AT16"O: I) �#4x10'AT160D(el I � � 534kPdd'I.WITHIN I I I � � S � S I � S S � S —_—_—_—_ _3`-6"tlf-3LRBEB('aE—� _—_ —_—_i—_—_—_— —_ _—_—_—_ _—_ _—_ _—_—_— —_ - - - - �� - - - -�-�� - - - - = - - .. _ .. --� -- = - - - = --fi— - -- - = __ _. - - - -- --_ --- - -- _ #4x10' AT 16"O 0@) #4x11' AT 16"p 0(e) —� .._. �I ��� ua n1 ia�o c. � as� � �� � �� � � � �� � �� � �� � :,I � zi a wrc � �• ; •.•. zi a wrc . , I z o L25 3]5 L25 3]5 1.5 3]5 L25 325 3 3 #4� AT� &B) 3 3 3 5 L25 3]5 1 25 3]5 y � � I li ADDL#4x13AT ��I dYo (3)#6CONT. 30'OFSLABIEDGE ADD'L#4x1YAT I � � z DIAPHRAGM BARS I� 18"O.C. (T&B)__ __ r m w x w __ �� 18"O.G (T&B)_ �3' _ = _ _ _ _ _ _ _ _ _ _ __��-_�-=� � ==i-�- ---_-�� - �- �--��� --��------- � r— �r=�===_� — — — — — — — (3.1������ I I I I I a � I I - � I I I I I I I� � I I I I I I RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 TH FLOOR POST-TENSION & MILD REINFORCING PLAN �' POST-TENSION PLAN NOTES O INDICATES NOTE REFERENCED IN PLAN 1_ SEE GENERAL STRUCTURAL NOTES (5100) AND TVPICAL POST TENSION DETAILS (5500 SERIES) FOR ADDITIONAL MFORMATION. 2. VERIFVALLDIMENSIONSANDELEVATIONSWITHTHE ARCHITECTURAL DRAW INGS. 3. WALL DIMENSIONS, SLAB OPENING DIMENSIONS AND SECTION CUTS SHALL BE PER FLOOR FRAMING PLAN. 4. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND STAGING OF ALL SHORING AND RESHORING. 5. STRUCTURALSLABTHICKNESSANDTOPOFSTRUCTURAL SLAB ELEVATIONS ARE SHOWN ON THE FRAMING PLAN. 6. COLUMN OR WALL OVER-POURS INTO POST-TENSIONED SLABS SHALL NOT BE GREATER THAN 1/2-INCH MAXIMUM. REMOVE ANY EXCESSIVE COLUMN OR WALL OVER-POURS PRIOR TO PLACMG REMFORCMG BARS AND POST- TENSIONMG TENDONS. 1. DO NOT INSTALL DRILL-IN ADHESIVE OR EXPANSION ANCHORS INTO THE POST-TENSIONED SLAB. DRILLMG INTO POST-TENSIONED CONCRETE W ITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD IS NOT PERMITTED. ALL BUILDMG SVSTEMS, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION SHALL PLACE DUCTS, CHASES, PIPES OR PIPE SUPPORTS, CONDUIT SLEEVES, AND HANGER INSERTS, ETC. INTO THE POST- TENSIONED SLAB PRIOR TO POURING THE CONCRETE. 8. HORIZONTAL SW EEP OF THE TENDONS SHALL NOT BE GREATERTHANI:6. TENDONSWITHAHORIZONTALSWEEP GREATER THAN 1:6 SHALL BE REVIEWED BY THE ENGMEER- OFRECORD FOR TENDON SPACING AND ADDITIONAL REMFORCING REpUIREMENTS PRIOR TO PLACING CONCRETE. 9. PROVIDE FULL ENCAPSULATED SVSTEM OF THE POST- TENSIONEDTENDONSANDANCHORS. ENCAPSULATION REQUIREMENTS PER GENERAL STRUCTURAL NOTES. 10. PROVIDEMINIMUMCONCRETECOVERPERTHECONCRETE COVER SCHEDULE, UNLESS A GREATER AMOUNT OF COVER IS INDICATED ELSEWHERE ON THE DRAWINGS. 11. CONTRACTORTOCOORDINATEEMBEDPLATESREpUIRED FOR STAIRS, GUARDRAILS, WALLS, CLADDING SUPPORT, ETC. AND SHALL SUBMIT AN EMBED PLATE AND EMBED ANCHOR LOCATION PLAN TO THE STRUCTURAL ENGINEER FOR REVIEW. CONTRACTOR SHALL BE RESPONSBLE FOR ALL DIMENSIONS, ACCURACV, AND FIT OF WORK. F�Fr� F�ooR E� ,ao.,. Fo�Rr� F�ooF e�. isa,s�� rHiao F�ooa E�. ixo�.3. sEcoNOF�ooi E� ,,o.,. SLABdNGRAC EL.98' 9" ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633�040 Structural Engineer CE Solutions, Inc. 10 Shoshone Drive Carmel, IN 46032 317324-6024 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority Way S. Dr. #204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE Ofi/21/19 F��ZNEW -p: 'NG 'p1 .�fJs`EqF; �r:'P o � PEt150IXN`i$ ?.�v lT�1tOF SHEETISSUE 1 Issued for C r�, RAT I O OJP✓PIGHIXOIIGEIHI6PPGHIIEGIOWILPXDEVGIXEHUXGdUWIXGI6GNEVIXGOXFlDEV@ BEUSF➢ONLV PU0.5UFNi i0 iHEOGFFFA1FNi WIiH FPil00PCHPFLS, INC NO WF��I99EAIW1ilONOP WPIIGilON1.41YBE1.41�EWPHOUiPPIOPWPIIIFNCON9FNi0F W1i10 NIT1uNGH50FOJP✓IUGHlPN�OMEPWI6EPPEHEPEBv WEqFlGLLYRESERYEC. PROJECT NO. 18087.001 SHEET TITLE GARAGE—FOURTH FLOOR POST—TENSION & MILD REINFORCING PLAN SHEETNUMBER S-204GPT ISOMETRIC - LOOKWG EAST