Loading...
HomeMy WebLinkAboutS-204MB - OFFICE - FOURTH FLOOR MILD REINFORCING PLAN -BOTTOM� #5@1' 0'•E.W.E.F. � \i �A \ / / _ _ � �i � / �� I � � � s- � s, L� v F.7 ; � F �; � X � � — � � ____— __— _— _____ ______ _____ -___ _I _ � _ �— I i F.3}- - -- — —r— — � E : 3'-0"WIDE ,. POURSTRIP ✓���%�i D �� ,,.C..,,.. #Sx8'�0" AT 18" O.0 (B) RA� IALLV AT SLAB E�G E d5x8'�0" AT 18" OA (B) RA�IALLVATSLAB E�GE - /�j \ '` � ) 1� - � -=�� RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 1 1 � n � H FLOOR MILD-REINFORCING PLAN - BOTTOM r L. �_J � � � � . � J A ■����� ■����� �������� �������� ■����� ■����� ■■ � \ � / \ � X � � _ � � � L � i i ,! r\ 3'-0" WIDE POURSTRIP L _ � � I X I � � � — \ ■��I ■��I ■���I ■���I ■��I ���I 8 S-W2/ --------------�---------------� I I I I I I _ — _ — _ — _ — _ — _ — _ — _ �I_ — _ — _ — _ — _ — _ — _ — _ — _'I _ — _ — _ — _ — _ — _ — __ I I l l i i I I I l 1, ,� ,� '�... :' A ��.. :' ^ ��.. �r ; . 8.... .,. 5-602 MILD REINFORCING PLAN NOTES O INDICATES NOTE REFERENCED IN PLAN 1. SEE GENERAL STRUCTURAL NOTES (5-100�, iYPICAL FRAMING DETAILS (5-601), AND TYPICAL MASONRV DETAILS (5401) FOR ADDITIONAL INFORMATION_ 2. VERIFYALLDIMENSIONSANDELEVATIONSWITHTHE ARCHITECTURAL DRAW INGS. 3. POSLTENSIONED TENDON LAYOUT SHALL BE PER POSL TENSIONED FRAMING PLAN. 4. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND STAGING OF ALLSHORING AND RESHORING. SHORING PLACED BENEATH SLAB CLOSURE POURS SHALL NOT BE REMOVED 11NTIL CLOSURE POl1R CONCRETE HAS REACHED SPECIFIED STRENGTH. 5. STRUCTURALSLABTHICKNESSANDTOPOFSTRUCTURAL SLAB ARE SHOW N ON PLANS. 6. COLUMN OR WALL OVER-POURS INTO POST-TENSIONED SLABS SHALL NOT BE GREATER THAN VY' MAXIMUM. REMOVE ANV EXCESSNE WLUMN OR WALL OVER-POURS PRIOR TO PLACING REINFORCING BARS AND POST- TENSIONED TENDONS. 1. DO NOT INSTALL DRILL-IN ADHESNE OR EXPANSION ANCHORS IN THE POST-TENSIONED SLAB. DRILLING INTO POST-TENSIONED SLAB W ITHOUT APPROVAL FROM THE STRUCTURAL ENGMEER OF RECORD IS NOT PERMITTED. ALL BWLDING SVSTEMS: MECHANICAL, ELECTRICAL, PLUMBMG, FIRE PROTECTION SHALL PLACE DUCTS, CHASES, PIPES OR PIPE SUPPORTS, CONDU IT SLEEVES AND HANGER INSERTS, ETC INTOTHE POST-TENSIONED SLAB PRIOR TO POURMG THE GONGRETE. 8. ADDITIONAL SHAFTS MAV BE LOCATED AFTER THE SLAB IS POURED IF APPROVED BV THE STRUCTURAL ENGMEER AND COORDINATED W ITH THE GENERAL CONCTRACTOR. 9. PROVIDE k5 AT 48" O.C. RISER BARS FOR TOP MILD REMFORCEMENTSUPPORT. 10. PROVIDE 1" CLEAR FOR ALL BOTTOM AND TOP MILD REINFORCING. 11. AT DROP BANDS, SPLICE BOTTOM STEEL AT WLUMNS AND TOP STEEL MID-SPAN PER LAP SPLICE SCHEDULE. 12. CONTRACTOR TO COORDINATE EMBED PLATES REQUIRED FOR STAIRS, GUARDRAIL, CURTAIN WALL, W INDOW WASHING ANCHORS, ETC. 13. REFER TO BEAM SCHEDULE FOR ADDITIONAL REINFORCING. 14. REFER TO DETAIL4/5312 FOR REMFORCING AT KNOCKOUT PANELLOCATIONS. ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Structural Engineer CE Solutions, Inc. 10 Shashane Drive Carmel, IN 46032 317-324-6024 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority Way S. Dr#204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE O6/21/19 SHEETISSUE 1 Issued for C r�, RAT I O wmuuwrnancerxicr�rtccruw��rno�nainccwnacwminaicaw�nincanrio�nce OSF �ISSFIAINdiION OP fUPLICdiION I� V�FF W�F NRH Wi PP�IOP� PIiiM CONSFNi OF PAi�Op WEqFlGLLYRE5ER4EC. PROJECT NO. 18087.001 SHEET TITLE OFFICE - FOURTH FLOOR MILD REINFORCING PLAN - BOTTOM SHEETNUMBER S-204MB