Loading...
HomeMy WebLinkAboutS-206MB - OFFICE - ROOF MILD REINFORCING PLAN -BOTTOM�J ps�, F.7 ; F �� !' F.3 }— — -- — — E 'p\ � q5x13'-0" AT 18" O.0 (B) RA�IALLVATSLABE�GE — I I �� � � � I� _ —� --��� -- ;'� I �. � I `�� i � � �� I \ : � I � �� �' � � � � L----1 � � \ � il � \\ � L----J p5x10'-0" AT 18" O.0 (B) RA�IALLV AT SLAB E�GE \� � �, -—-—-—-—-—-—-—�—-—-—-—-—-—-—-— MILD REINFORCING PLAN NOTES O INDICATES NOTE REFERENCED IN PLAN 1_ SEEGENERALSTRUCTURALNOTES(5-100),TVPICAL FRAMMG DETAILS (5-601), AND TVPICAL MASONRV DETAILS (S-]01) FOR ADDITIONAL MFORMATION. 2. VERIFVALLDIMENSIONSANDELEVATIONSWITHTHE ARCHITECTURAL DRAW INGS. 3. POST-TENSIONED TENDON LAVOUT SHALL BE PER POST- TENSIONE� FRAMING PLAN. 4. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND STAGINGOFALLSHORINGANDRESHORING. SHORING PLACED BENEATH SLAB CLOSl1RE POl1R5 SHALL NOT BE REMOVED UNTIL CLOSURE POUR CONCRETE HAS REACHED SPECIFIED STRENGTH. S STRUCTURALSLABTHICKNESSANDTOPOFSTRUCTURAL SLAB ARE SHOW N ON PLANS. 6. COWMNORWALLOVER-POURSINTOPOST-TENSIONED SLABS SHALL NOT BE GREATER THAN il2" MAXIMUM. REMOVEANV EXCESSIVE COWMN OR WALL OVER-POURS PRIOR TO PLACMG REINFORCMG BARS AND POST- TENSIONED TENDONS. �. DO NOT INSTALL DRILL-IN ADHESNE OR EXPANSION ANCHORS M THE POST-TENSIONED SLA6. DRILLING MTO POST-TENSIONED SLAB W ITHOl1T APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD IS NOT PERMITTED. ALL BW L�ING SYSTEMS'. MECHANICAL, ELECTRICAL, P W MBING, FIRE PROTECTION SHALL PLACE Dl1CT5, CHASES, PIPES OR PIPE SUPPORTS, CONDUIT SLEEVES AND HANGER INSERTS, ETC INTO THE POST-TENSIONE� SLAB PRIOR TO POl1RING THE CONCRETE. 8. ADDITIONAL SHAFTS MAV BE LOCATED AFTER THE SLAB IS POl1RED IF APPROVED BV THE STRl1CTl1RAL ENGINEER AND COORDINATED W ITH THE GENERAL CONCTRACTOR. 9. PROVIDE #5 AT 48" OL. RISER BARS FOR TOP MILD REINFORCEMENT SUPPORT. 10. PROVIDE 1"CLEAR FOR ALL BOTTOM AND TOP MILD REINFORCING. 11. AT DROP BANDS, SPLICE BOTTOM STEELAT COWMNSAND TOP STEEL MID-SPAN PER LAP SPLICE SCHEDULE. 12. CONTRACTORTOCOORDINATEEMBEDPLATESREQUIRED FOR STAIRS, GUARDRAIL, CURTAIN WALL, WINDOW WASHING ANCHORS, ETC. 13. REFER TO BEAM SCHEDU LE FOR ADDITIONAL REINFORCING. 14. REFER TO DETAIL 4/5312 FOR REMFORCMG AT KNOCKOUT PANEL LOCATIONS. ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633�040 Structural Engineer CE Solutions, Inc. 10 Shoshone Drive Carmel, IN 46032 31 73 24-60 24 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority Way S. Dr#204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE O6/21/19 ,,.C..,,.. ie���:�.����d��;���r���ena��in; Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 1 1 I � _ �� n �� r v11LD-REINFORCING PLAN - BOTTOM I � II I I — _ — _ — _ — _ — _ — _ — _ �I_ — _ — _ — _ — _ — _ — _ — _ — _'I _ — _ — _ — _ — _ — _ — __ I I l l i II � --------------�----------------a--------------- I I I il il il � � � 1� ,� ,� '�... :' � ��.. :' ^ ��... �� SHEETISSUE 1 Issued for C r�, RAT I O wmuuwrnoncerxicr�rtccruw��rno�nainccwnacw��vinaicaw�ninconrio�nce eeusrnorv�rauesunrv..omeweru�r�u.wi.nen.io,wwnEcs.irvc rvo �SF��195NINdi�lONO�fAIPIIQilON1.41VFR.4IDFWPHWiPPIOPWPIIIFNfqN9FNi0F W1i10 PROJECT NO. 18087.001 SHEET TITLE OFFICE - ROOF MILD REINFORCING PLAN - BOTTOM SHEETNUMBER S-206 M B