HomeMy WebLinkAboutS-208.1-OFFICE-BRIDGE-CONNECTOR-FRAMING-SECTIONS--DETAILSTVP. � � 11 1/4' NOTES 1. LENGTHSOFTREADSl1PPORTSVARV 2. SETHEIGHTANDORIENTATIONOF TREAD Sl1PPORT BASED ON SOl1TH STRINGER 3. NOTCH LEGS OF BENT PLATE AS RE�UIRED FOR FLAT BEARWG ON NORTH STRWGER A. ATTACHEDTOSTRWGERSWITHWELD AS SHOWN ABOVE 5. ATTACHADJACENETTRADSUPPORTS WITH 7" STITCH WELDS AT 72" O.C. — 3I8"THICKBENTPLATE � TREADSUPPORT � TOP OF STRINGER �' ;4'. TREAD SUPPORT DETAILING �'�szcai i i ve — r-o �._8. � Ep — Ep � O � _ — _ — - 20" x i 6" x 1" THICK � BASE PLATE w W-SHAPE COLUMN, SEE PLAN _, � o w ' (6)1"DIA_ANCHOR � � - BOLTS (18" EMBED MIN.) _ �' .. � 5/16•' 2" TYP.- � `� BRIDGE CONNECTOR - VARIES, SEE PLAN _ SLAB,SEEPLAN OFFlCE BUILDING llP' EXP. JOINT MATERIAL 6' X 6" X 1l4" EMBED PLATE W. (4) V2" DIA X A" LONG HEADED STUDS, SPA. AT 24" O.C. MAX. .❑. � � I- SLAB REMFORCMG NOT SHOWN FOR CLARITY 1 BEAM,SEEPLAN — � . - L4x4x1/4,CONT. 3/i6 ,o' TYP. SLAB TRANSITION AT OFFICE �sz�,J ,..=,._o.. BEAM REINFORQNG, - SEEGARAGEBEAM SCHEDULE AND DETAILS � � TiCONC. I SEE PLAN J • • •', � I � � Cl1RTAIN WALL BV OTHERS I 1�5II7 . I � BXB"X12"EMBEDPLATEW.(a) 12' DIA X 4" LONG HEADE� STl1D5, PARKMG SPA. AT 48" O.C. MAX. GARAGE � � � I �I, i ❑ 1 i � ~ � � �., 2. � BRIDGE � CONNECTOR 5/i6 2" EXP. JT _ HS54X4X3I8 � 3/i6 2AT12 xz�-o^�oNc I � AT 4'-0" O.C. — �TISTEELEL. SEE PLAN 1/4_ � � ROOF �ECK, SEE PLAN 1 /4 (Z,L3x3x3,8x,�.a•�ON� . _ � ,. L3X3X114 � BEAM, SEE PLAN L4x4x3I8, CONT. 3/i6 2AT6 � . 1'-0'•Xa"X3/8"THICK BENTPLATE,CONT. „' TYP. ROOF EXP JT. AT GARAGE S'tC8.1 ' 1•• = 1• �•• ;5' BRIDGE CONN. COL. BASE PLATE �... S'tC8.1 �' �.. _ �. �.. rc��U L Z CL�,� TVP. COLUMN qNCHORBOLTS PER PLAN -� WILEVELING NUTS PARKING BRIDGE GARAGE CONNECTOR - SEE DETAIL 15/&208.1 1P' X 6" X 3I8" EMBED PLATE W. (4) FORANCHORBOLTSAND 1/2'DIA.XA"LONGHEADEDSTUDS, BASE PLATE INFORMATION I �� SPA. AT 24" O.C. MAX #3TIESAT3"O.GTOP, a � "� p E%P � 12" O.C. BALANCE � '�' � �JT � (12)#]LONGINDINAL `e 3116 2AT12 BARS . � � � J �� � �� - T/STEEL EL. 2" CLR. � ! �� � SEE PLAN TOTIES���� � �� � 24' X 24 PEDESTAL I � -� � � swe, see awN ' I I � � ww �r • ��' - ' y � � , BEAM, SEE PLAN y 9TD_ � BEAMREWFORCWGi 90"XB"X2/8"THICK � �-Laxaxl/a,CONT. SEE GARAGE BEAM BENT PLATE WITH 3B" HOOK - COMBMEDCOLUMN SCHEDl1LEANDDETAILS STIFFENERSAT9"OC. SEE SCHEDULE FOOTING, SEE SCHEDULE ;fi' BRIDGE CONN. COL. PIER & FOOTING �'�szcai i sia — r-o ,2' TYP. SLAB EXTENSION AT GARAGE �sz�,J ,..=,._o.. �, �� I I I I COLUMN, SEE II S E PLAN SEE PLAN PLAN II I I II ' � LAxAx1/A,CONT. I I I I II I I II II ;'���'� � � � W �� — �s7 ara• oin. naw ao�is, II O d PRETENSIONED II O �u 0 a � �/ II � . RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 BEAM-COLUMN �� ��f' �� . � BEAM,SEEPLAN CONNECTION,SEE . OTHERDETAILS � �— BEAM,SEEPLAN PROVIDEFABREEKATIM. � � 7/2"ENDPLATE BEARING PADAND WASHERSATTHERMAL BREAK SPLICE ,3' TYP. THERMAL BREAK SPLICE $��,; ,.._,._o.. 2 EXP. JT - - �U II PARKING GARAGE e SECTION .sas.ii i.._�._o.. PARKING GARAGE I �j . 2 EXP : JT. 9', SECTION ���. S FC8.1 i 1•• = 1• �•• s SECTION s��,; ,..=,._o.. � SECTION � s��,; ,.._,._o.. ROOF DECK NOT SHOWN FOR CLARITY SEE DETAIL 3/5-208.1 FOR BALANCE OF INFORMATION — 3/8" THIGK STIFFENER PLATE, EACH SIDE � BEAM,SEE PLAN �T/STEEL EL. SEE PLAN Q..� � FLOOR DECK NOT SHOWN FOR CLARITV SEE DETAIL 2/5-208.1 FOR BALANCE OF INFORMATION �T��. TISTEEL EL. SEE PLAN BEAM,SEEPLAN 3/8" THICK STIFFENER PLATE, EACH SIDE ROOF DECK NOT OICJ :i SHOWN FOR CLARITV �2 ' • - 3-SIDES 3/8"SHFARTAB . � 3/16 N V2I'GA�r � .. T/STEELEL. _ � � ' � SEE PLAN � �.. _ I�..�� � � - O � THERMALBREAK, =� T � I SEE DETAIL 13/5-208.1 3ROWSOF3l4"DIA. I � BEAM,SEEPLAN A325-SC BOLTS, TVP. �I �� � FLANGE STIFFENER, SEE FRAME ELEVATION 3/8"SHEARTAB —�� �I II L II COLUMN,SEEPLAN 4 , SECTION sAai I r. = r-o.. FLOOR DECK NOT SHOWN FOR CLARITY 3/8" THICK GUSSET PLATE,TVP. .. EREcrioN BOLT — HSSBRACE SEEELEVATION . ► O O TYP 1/4 S' � BEAM,SEEPLAN � SEE DETAIL 4IS-208.1 FOR BALANCE OF INFORMATION 5 , SECTION '....SFC81 i 1•• = 1• 0•• ' 0.5 � I : . � � � sy i a / ' �TSTEEL EL. SEE PLAN O � P p � � � THERMALBREAK, � SEEDETAILI3/5-208.1 � — TYP. il4 COLUMN,SEE PLAN ROOFDECKNOT (9)1pHAIRPINS OFFlCE SHOWNFORCLARITV C BUILDING 18' �EEPLAN� 9 1 PTSLAB,SEEPLAN SEE DETAIL 3/5-208.1 FOR � BALANCE OF INFORMATION 3/8"THICKSTIFFENER ' � - SLABREMFORCMGNOT PLATE, EACH SIDE I � SHOWN FOR CLARITV BEAM,SEEPLAN I � ' TISTEEL EL .�� SEE P� �I 1 3/8"THRl1PLATE � HSS6X6X3/8 W. (3J 1 DIA 0 X 1'-0" LONG — - -A325-SC BOLTS� O � O ,- 1/a"CAPPLATE ♦ — 14 X1-2"X1"THIGKEMBED � 1/2" GAP��� PLATE WITH (BJ 3l4" DIA. X 12'• ��� Q�� LONG WELDED STUDS IIa o 0 0 — �F o 0 0 i� �� I � 1 i v4 �......._I _�--0" OFFSET i iia._.�,.ry ���� � � �d� Cn' O� � " „\\"QI�� p�--- ��U ALL BOLTS 3/4" DIA. A325 ; FRAMING DETAIL '�.. s�Aai ; �.. _ �._o.. ROOF DECK NOT SHOWN FOR CLARITY 3I8"THICKSTIFFENER PLATE, EACH SIDE I ZI BEAM,SEEPLAN � � 3B"THICKGUSSET � �� �. PLATE, TVP. 1" TYP:. . I HSSCOWMN, � SEEELEVATION - ��z`� SECTION �..... ���8, :: ,.. _ ,._Q.. 3/8" THICK STEEL PLATE � � �� BEAM,SEE PLAN DOl1BLE ANGLE CONNECTION, TVP. • va ' ERECTION BOLT � il4 5' FLOOR DECK NOT SHOWN FOR CLARITV 3/9" THICK GUSSET � � �q PLATE,TVP. — I I . I I ERECTION I I BOLT — I I [`����. I I � � I I � I I � \\\ � H55 BRACE, � � � II /�� SEEELEVATION i �� i i r � . � TYP. W.P. 1/4 5" BEAM,SEEPLAN - - - 3/8"THICKSTIFFENER PLATE, EACH SIDE 3 SECTION '�.. s�Aai ; �.. _ �._o.. FLOOR DECK NOT SHOWN FOR CLARITY SEE DETAIL 2/5-208.1 FOR BALANCE OF INFORMATION T/STEELEL ■ I '/4 SEEPLAN `�� � I � I � 1/2' I � GAF YB"SHEAR PLATE O w. �al r• oin A325-SC BOLTS BEAM,SEE PLAN - SEE PLAN 3/8"THICKSTIFFENER ' PLATE, EACH SIDE ,.,�2. � _T�P. F OFFICE o BUILDMG "' � , e > � 16" X 1'-J" X 1" THICK EMBED PLATE WITH (8J 12" DIA. X 8'• LONG WELDED STl1DS . SLAB REINFORCMG NOT " - SHOWNFORCLARITY PT SLAB, SEE PLAN (3) #4 U-BAF „ C 32" r�, RAT I O mvmo rrvorcer s u rEcruan�nrvo�norv�rvoun rvo so �urvcorvro�nce nrvos�n us o usu **omewer��r�u.w. o rs,rvcrvoomra uscryos o o ru . orvwraewoewnxou*ry o A v�+i*aw+*o saecFu rzesezeee. PROJECT NO. 18087.001 SHEET TITLE OFFICE - BRIDGE CONNECTOR FRAMING SECTIONS & DETAILS SHEETNUMBER S-208.1 1�� ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Structural Engineer CE Solutions, Inc. 10 Shoshone Drive Carmel, IN 46032 317-324-6024 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority Way S. Dr#204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE 06/21/19 � T/STEELEL. Q.�E�VIOqf`O �'s5F\! SEEPLAN */p NO o\*4 ! .�,PE19900097 �� 'D�� STAiE OF � �" oF�S�ONA1-EaG`� � :,���� ei 0�0� J ���. `. SHEETISSUE 1 Issued for Construction