Loading...
HomeMy WebLinkAboutS-502 - TYPICAL POST-TENSION DETAILS - 02.....__ ........� P.T. BEAM � GROUT STRESSING POCKETS DEAD ENDS AND STRESSING ENDS VY' LATEX • • MODIFlED • • CONCRETE •�. � �� � ANCHORPATTERNAS REQUIRED TO MAINTAIN PROPER Fe REQUIRED AND C.G. OF STRAND. SEE BEAM SCHEDULE SECTION ELEVATION NOTES: 1. CLEANPOCKETSURFACES 2. PLACEGROUTIMMEDIATELVAFTERSTRESSWGRECORDSHAVEBEENAPPROVED 3. APPLYLATEXMODIFlEDCONCRETESURFACECOAT ;'9 PT POCKET DETAIL �.... S�W2 ,' 3.. _ �. Q.. 3" MAX.� � PLAN ^ i' E �� i �. � BEROFTENDON 30" MIN. ADD4#4 SHEAR KEVS 3"x 1/2" TYP. .— SEE NOTES I SEGTION I�� � ���� � STRANDTAILS � SEE NOTES NOTES: 1. IF BLOCKOUT IS EXPOSED TO WEATHER WG AND OR MOISTURE USE GROMMETS; CUT STRESSED STRAND TAILS; PREPARE AND SEAL STRESSING POCKETS AS STIPULATED IN GENERAL NOTES; CAULK JOINT ALL AROUND. 2. CONTINUEALLIMERUPTEDBARSSHOWNINPLANSTHROUGHTHEBLOCKOUT. 3. FlLLBLOCKOUTWITHNON-SHRINKCONCRETEOFMIN.SAMESTRENGTHASSLAB. ;',o STRESSING BLOCKOUT �.... S�W2 ,' 1/2.. _ �. Q.. ADDED REBARS AND HAIRPIN AT BANDED TENDONS ONLY PER z� � w h' i6MIN.STRAIGHT 12"APPROX. � � :: #4 x 48" @ 24" O.C. TOP 8 BOTTOM (J' w �I� � NA " — — — — — J .':� PT SLAB 2 -#4 BACKUP BARS AT DISTRIBUTED TENDONS ONLV PER L ' SEE NOTE — SHEAR KEYS PER NOTE: SLIDE / PLACE AND SEAL CORROSION PROTECTIVE SLEEVE OVER EXPOSED STRAND AFTER STRESSING CONSTRUCTION JOINT WITH INTERMEDIATE 5 , STRESSING �.... S�W2 i 1 1/2•• = 1• �•• I�� CONSTRUCTION JOINT FIRSTPOUR � SECONDPOUR SLAB REINFORCEMENT ���� � ��y� _ ��� � ADD'L REBAR CONTINUOUS �f � #5 x 3'-0" @ 12' o.c. AT MID-0EPTH z < o W w w' o NA w � PTTENDONCONT. � SHEAR KEVS P-0" LONG @ 4'-0" o.c. PLAN VIEW � NOTE: . � � JOINTS SHALL BE LOCATED CLOSE TO N' 1/40FSPAN 1 .......__I __-. CONSTRUCTION JOINT WITH NO INTERMEDIATE s , STRESSING �.... 5.�A2 ,� ,�2.. _ ,._Q.. TROWELEDGE ......... �\ �� 1/2"CHAMFER ' 21/2. _ ....�.�.,,�.�� MIN. 1/2" CLR.. TYP. .�- SLABEDGE,TYP. � a �� � PERIMETER SLAB EDGE - �'- CORNER SLAB EDGE REINF. PER PLAN, TYP. REINF. TO MATCH PERIMETER SLAB REWF. PLAN - EXTERIOR SLAB EDGE CORNER (2) #5 T&B x 48" DIAG- PERIMETER SLAB EDGE REINF. PER PLAN, TVP. SLAB EDGE,TYP. �NOTE: POST-TENSIONING ANCHORAGE AT SLAB CORNERSPER�03304A) PLAN-WTERIORSLABEDGECORNER PLAN - TYP. REINFORCING AT ', SLAB EDGE CORNERS '..... s�W2 ' 1/2.. _ �._Q.. BANDEDTENDONS PER PLAN DIST. TENDONS PER PLAN PERIMETERSLABEDGE �� REINF. PER PLAN, TYP. NOTES: 1. REWFORCWGATPOST-TENSIONWG ANCHORS NOT SHO WN FOR CLARITY. 2 IF EDGE DISTANCE CANNOT BE MET, CONTACT ENGINEER. . - SLABEDGE,TVP. - CORNER SLAB EDGE � REINF. TO MATCH EDGE REINF. �_� � °� PLAN - TYP. CAL POST-TENSIONING 2, AT EXTERIOR SLAB EDGE CORNERS �.... S�W2 :' 1/2.._ �. Q.. W HERE TENDONS TURN SUPPORTBARS� TOP & BOTTOM BARS � HAIRPIN / � � 36" STRAIGHT i .y SVM. 4 STRAND MAX. PERBUNDLE TVP.BETWEEN � BUNDLESUN.Q � e Z MIN.SPACWG � i " � ���"��— GROMMETAT STRESSING END �������— SLAB EDGE ONLY ZP Investments, LLC Office North Illinois St Carmel, IN 46032 Owner ZP Investments, LLC 11460 N Meridian Street Carmel, IN 46032 317-705-5050 Architect RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 3 � 7-633�040 Structural Engineer CE Solutions, Inc. 10 Shoshone Drive Carmel, IN 46032 317324-6024 Mechanical / Electrical Engineer Heapy Engineering 3850 Priority W ay S. Dr #204 Indianapolis, IN 46240 317-571-8795 Civil Engineer Civil & Environmental Consultants, Inc. 530 East Ohio Street G Indianapolis, IN 46204 371-655-7777 SEAL � DATE 06/21/19 SHEETISSUE 1 Issued for C RELEASED FOR CONSTRl1CTI0N Su6jec� �o compliance with all regula�ions of Sla�e antl Local Codes City of Carmel �� `��¢m�' lamn�Ml1 � onrE: 09/19/19 � ', SLAB EDGE AT OVERHANG 5.�z 3.. _ ,._o.. rc U CONT.TOPBAR SEE ELEVATION � I ¢ a w w � O PTTENDONS II STIRRUPS, �.OR. . SEE Q @ SUPPORT I BEAM ELEVATION FOR JCONDITIONS - SIZEANDSPACING w • I • � w I .� PTTENDONS@LOWPOWT m 2#4CONT. w I N SUPPORT CHAIR, SEE DETAIL 1 � I,,� : CONT. BOTTOM BAR + JiiLI I�I I�I �. �� SEEELEVATION � - I � � o . 1 VY' CLR. - 3/4" CHAMFER � �SEE BEAM ELEVATION T�PICAL NOTES: L FOR POST-TENSIONWG FORCES SEE BEAM ELEVATIONS 2. KEEPTENDONGROUPSUNIFORMLYSPACEDTHROUGHOUT THE LENGTH OF BEAM '8 ', PLACEMENT OF TENDONS IN BEAMS ���. 5��3 / 1 12•• - �• �•• FLARING OF BANDED TENDONS 3 AT SLAB EDGE �..... 5.�A2 � , ,�2.. _ ,._Q.. N6x13'-0"@ 9" O.C. TOP, EACH SIDE POUR STRI P 3' - 0" � 3/8" V-GROOVE AND UNOONPLAN SILICONSEALANT #5x11'-0"AT9" 3 31/4", TVP.ATTOP O.C. BOTT. EACH SIDE �, �'� � I �� : SEE NOTES ADDED T&B BARS - I . AND HAIRPIN OR L BACKUP BARS PER SHEAR KEYS PER (5) k6 T&B �. CONT ., � I . . J ', KEEPSHORED, SEE NOTES � 1/2 TVP. C, NOTES: 1. RETAIN SHORWG UNTIL CLOSURE CONCRETE REACHES SLAB'S DESIGN STRENGTH OR 14 DAVS 2. CLOSURESTRIPTOBEPOUREDWITHNON-SHRWKCONCRETENOTLESSTHANDAYSAFTER STRESSING 3. ROUGHEN&CLEANJOINTS&WETPRIORTOPLACWGCONCRETE. 4. ELIMINATEACCIDENTALMISALIGNMENTBEIWEENEDGEOFSLABSTHATARETOBEJOINED W ITH A CLOSURE STRUP. USE M ECHANICAL M ETHODS SUCH AS JACKING IF NECESSARV. 5. RAISE EDGE OF SLAB 1/4" AT CLOSURE TO ALLOW FOR SETTLEMENT. 6. PROVIDE WATERPROOFING MEMBRANE IF REpUIRED FOR WATER-TIGHTNESS. ]. CUT STRESSED STRAND TAILS; GREASE AND PLACE END CAP. ;'4 , POUR STRIP ���. 5��3 :' 1/2.. _ �. �.. r�, RAT I O mwa�rorer a reruai�ano�nan�canacz�wnaca¢nnconro�n� usF,ryoss .�. �'"'��� a��sarwvmuau.aa�aauv..vuarv'svu.a�w�.�a� wecFu rxesexeee. PROJECT NO. 18087.001 SHEET TITLE TYPICAL POST-TENSION DETAILS - 02 SHEETNUMBER S-502