CMU LINTEL SCHEDULE
LINTEL SIZE gTM. TOP EXTEND TIES SPAN
DESIGNATION BARS PASTOPNG.
8-A 8"x8" 2-#5 - 8" - TVP.WALL<q-g^
8-B 8"x16" 2-#5 2-#5 16" - TVP.WALL<8-0"
8-C 8"x24" 2#5 2#5 16" #3AT8" O.C. TVP. WALL <12 0"
12-A 12"x8" 2-#5 - 8" - TVP. WALL <4 8"
12-B 12"x16 2aF5 2at5 �6" - TVP. WALL <8 0"
12-G 12"x24 2aF5 2at5 �6" #3AT8"O.G. TVP.WALL<�20"
LINTEL TYPES:
a
r�
p� � �� USE KNOCKOUT BLOCK WI (2) #5
MIN. UNLESS BOND BEAM OCCURS
W/LARGERBARS
#3 TIES W/ 180° HOOKS AT EA. END
IN GROUTED CELLS - SEE SCHED.
A B � FOR SPA.
NOTES:
L LMTEL BLOCKS AND BOTTOM BARS TO EXTEND PAST CMU OPENING TO W IDTHS INDICATED
IN SCHEDULE. CUT OUT BOTTOM SHELL OF LINTEL BLOCKS AT BEARING TO ALLOW
INTEGRAL GROUTMG OF LINTEL 8 FlLLED CELLS BELOW AT BEARMG. PROVIDE FlLLED CELLS
FULL WIDTHOF BEARINGS INDICATED WITH VERTICAL IN EACH CELL EXTENDING FROM
FLOOR TO FLOOR TO ROOF. USE BAR SIZE INDICATED FOR WALL THICKNESS.
2. CONSTRUCTION JOINTS SHALL NOT OCCUR W ITHIN 2" OF THE ENDS OF THE LINTEL
BEARINGS.
3 LINTELS SHALL BE GROUTED SIMILAR TO WALLS. ALL GROUT MUST BE CONSOLIDATED
PN ICE, ONCE W ITHM 5 MINUTES OF PLACEMENT AND ONCE 15-20 M INUTES AFTER
PLACEMENT.
,2 CMU LINTEL SCHEDULE
'�. ��oi ' vz. — r-o.
DOWEL, MFTCH
SIZE AND SPACING
OF VERT. REINF.
MASONRV WALL � - � — gOND BEAM,
PTSLAB GROUTSOLID
I I
�T/SLAB
SEE PLAN
� o�', �
�o
REINF. PER PLAN ` � w
1/2"x8'k8" EMBED PL � o
W ITH (2) llP' DIA. X 4
LONGSTUDS.
SPACE PLATES AT 3'-0 — BOND BEAM,
O.C. ALONG WALL GROUT SOLID
12" DIA EXP. ANCHOR
4" MIN. EMBED.
CONNECTTO WALL WITH
Sx3x1/4"X6"LONGCLIP ' �
ANGLE AT 3'-0" O.G.
USE LONG SLOTTED HOLE
ORIENTED VERTICALLV
,3' NON—BEARING MASONRY TO SLAB
. 5101 : 3/4• = 1• �•
STD STD LAP QVP)
HOOK HOOK DOWELSTOMATCHAND
LAP W/ BOND BEAM
REINF
� 1 . . . . . ... �
I III I
I I I r ��'— BOND BEAM REINF . � I
3
BOND '
BEAM
REINF
WALL�
THK.
#2SPACERSAT48"O.C. ��
BOND BEAM REINF.,
SEE PLAN AND SCHEDULE
9 TYP. BOND BEAM REINFORCEMENT
��,. s��oi ; r. _ �._o..
WALL�
THK.
IgOND6EAMATTOPWALLI _ _I � ONDBEAMATTOPWALLt--Ir
--_-- — -- — -- T
�� I - . . — . � II�. �. . I.� I . . . .I I.
�- �i r�------------�� i� . .� i� II. I� II. I. I. I. i I I.
�� STEEL LINTEL � I. � I I� � MASONRV LINTEL �
d' . �. I� BEARING 5. ' . . I � —_ —_— �, I.
� I� PLATE(TVP). � I �A � �.SEESGHED. �
I - � � � . SEE SCHED_ � - 1 � � �
� lij� �� I >VERTICAL �I :� II
� � I MASONRY I�� �� REMETO I� � MASONRY
.--�. OPENMG r� .. MATCH I OPENMG �
WALL I I I
. . I I - I i- � REINF I� i I � I
--- L I
I I � I.I " II.
� �. . .
1____________1 I. � ___ __ L I.
-.� . ;�. [ I ��A� I !I I
8" DEEP BOND BEAM (OMIT � VERTICAL REINF. TO -'— 8" DEEP BOND
AT DOOR OPENMGS) MATCH WALL REINF. BEAM (OMITAT
DOOR OPENINGS)
,o TYP. WALL OPENING REINFORCING
. 5�101 : 3/8" = 1'-0"
6"
MIN.
WALL MAV CONTINUE
ABOVEBEAM �
WRAPBEAMW/ ...
BUILDING PAPER.
BUILD BEAM
INTO CMU WALL
BEARING PLATE,
SEE PLAN
CMU WALL,
SEE PLAN
�i NOTES:
SECTION 1. BEAMS 10'-0" OR LESS SHALL
HAVE'GUIDE BARS' AT BEARING
PLATES AT ONLV ONE END OF
BEAMS.
BEAM 2. BEAMS GREATER THAN 10'-0"
SHALL HAVE'GUIDE BARS' AT
�� BEARMG PLATES AT BOTH ENDS
OF BEAMS.
3. DO NOT W ELD BEAM TO BEARING
i PLATE WHERE'GUIDE BARS'
CMU WALL —'"�� CONNECTIONSOCCUR.
�� BEARING 4� FlLLALL CORES W ITH GROUT
PLATE FULLHEIGHTBELOWBEARWG.
SEE PLAN
PLAN
BEAM PERPENDICULAR TO MASONRY WALL
ENCASE BEAM IN
MASONRV
I:iY_\:ll�[H�C\Itl
ELEVATION
NOTES:
1. BEAMS 10'-0" OR LESS SHALL HAVE
'GUIDE BARS' AT BEARMG PLATES
AT ONLV ONE END OF BEAMS.
►
SEE NOTES
. � 3116" 3" MIN
1I2"x1/2"x0'-4"GUIDE � �-'
BARS (NEAR SIDE AND '
FARSIDE�AS :
SPECIFIED IN NOTES- ���
WELDEDTOBEARING SECTION
PLATE ONLY
PROVIDE NON-SHRMK
GROUTASNECESSARV
TOACHIEVE PROPER BRG. EL.
� �— GROUTED CMU
. (NOBEARMGATBRICK).
— #4 FULL HEIGHT IN
GROUTEDCORE(UNLESS
OTHERW ISE NOTED).
2. BEAMS GREATER THAN 10-0 — gEAM, SEE PLAN
SHALL HAVE'GUIDE BARS' AT
BEARING PLATES AT BOTH ENDS ✓ BEARMG PLATE,
OF BEAMS. SEE PLAN
3. DO NOT W ELD BEAM TO BEARMG
PLATE WHERE'GUIDE BARS' HOPoZJT CMU WALL
CONNECTIONSOCCUR. REMF
4. FILL ALL CORES W ITH GROUT FULL
HEIGHTBELOW BEARMG.
SECTION
BEAM PARALLEL TO MASONRV WALL
;; , STEEL BEAM LINTEL DETAIL
� 51C1 : 3/4•' = 1• 0•'
�
SEE NOTES
3/16" 3" MIN
� -. T/STEEL EL.
� SEE PLAN
1I2" x 1/2" x 0'-4" GUIDE
BARS (NEAR SIDE AND
FAR SIDE) AS SPEQFIED
INNOTES-WELDEDTO �—�
BEARMGPLATEONLY SECTION
ARTIAL HEIGHT COURSE
!K GROUT AS NECESSARV TO
ROPER BRG. ELEVATION.
VERTICAL REMF. � CENTERING CLIP
��
� �
I �
f t �
� � � .
� HORRONTALREMF.
!
CMU '
CENTERING CLIP
VERTICAL VERTICAL —. — CENTERING
REINF. CENTERING REINF. CLIP
CLIP � j�
�
�
; ¶ , �.�� 1
L��
L I � �,,�Q�:,
� � HORRONTAL
I REINF.
CMU � CMU ' �"
CAGING DEVICE DUAL-CENTERING CLIP
NOTE:
1. CAGMG DEVICES AND CENTERMG CLIPS SHALL BE FORMED FROM
#9 HARD W IRE; SPOT W ELDED AND GALVANRED
5 TYP. MASONRY REINFORCING CLIPS
'�. ��oi ; �.. _ �._o..
�❑ ❑a o❑ ❑o
VERT.WALLREMFM �—CONTROLJOINT
GROUTED CORE PLAN :� MATERIAL
— �� � � �� —
—� i . . . i .. ..
�" 6 I •lf. � 6 �
I
—_—. .. I I �.
-- . :: : �. I ..... .
I I �.......�
I I "��� BONDBEAMREMETO
I I BE CONL THRU
� CONTROL JOINT, SEE
I ��� SIS401
ELEVATION
NOTES:
1. BOND BEAM REINF. SHALL NOT BE LAPPED W ITHIN 8'-0" OF CONTROL
JOINT.
2. HORRONTALJOINTREINF.SHALLBEDISCONTINUOUSATCONTROL
JOINTS.
3. CONTRACTOR SHALL OBTAIN ARCHITECT'S APPROVAL OF CONTROL
JOINT LOCATIONS, W HICH SHALL NOT EXCEED 25'-0" O.C.
fi TYP. MASONRY CONTROL JOINT
', g101 ; p. _ �. Q..
VERT. REINF. (CONT.
THRU BOND BEAM)
CORE FILLED SOLID
WITHFINEGRWT �1 /
� �E( �
HORRONTAL — � �
r
REINFOROMG i � � �� OONO. MASONRV
� � BOND BEAM UNITS
s _� � � �
— #2 SPACERS AT 48" O.C.
; "� TYPICAL MASONRY BOND BEAM
�� �,o, „��..=,._o..
INTERRUPTREINF.BARS � (1)-1/2"DW.SMOOTHBAR2'-8"
AT CONTROL JOINT LONG, APPLY GREASE TO
ONE END. INSTALL LEVEL
a — -- � �_ _=
a —�
w _� I _�
w -- - ��- --
�, — --
�
� � , � .. i `,_.. . .
BOND BEAM BLOCK � I � CONTROLJOINT MATERIAL
HORR.REINF.,SEEPLANJ� —RAKEBACKJOINTAND
AND SCHEDULE SEAL BOTH SIDES
e BOND BEAM DETAIL
�,o, ; ,.._,._o..
— SEE PLANS AND PLAN NOTES FOR
LOCATION OF GROUTED CELLS
SEE MASONRV LAP SPLICE LAV UP NEXT 4'-0" OF WALL AFTER
SCHEDULE (GEN. STRUCT. LOW ER SECTION IS GROUTED
NOTES) FOR LAP LENGTH . STOP GROUT 2" (MIN.) BELOW TOP
OF UNIT IF POUR IS STOPPED FOR
MORE THAN ONE HOUR
VERT. MASONRV REINF., SEE �
PLANANDSCHEDULE �
FULLVGROUTALL 1"V�o
MASONRVCORESSOLID -
GROUTTOCONFORMTO LL
ASTMC4]6SUBMITMIX J
DESIGN FOR REVIEW. MAX �
AGGREGATESIZE=3/e" �
WITHS"T011"SWMP. DO x
NOT �
USE SAME MIXAS USED FOR
TIE BEAMS
�
NOTES:
1. DONOTGROUTUNTILMORTARHASSETSUFFICIENTLV
TO W ITHSTAND THE PRESSURE OF THE GROUT. WAIT
NO LE55 THAN 24 HOURS.
'; LOW LIFT GROUTING DETAIL
'�.. s��oi ; ve.. _ �._o..
SEE PLANS AND PLAN NOTES FOR
LOCATION OF GROUTED CELLS
� STOP GROUT 2" (MIN ) BELOW TOP
SEE MASONRV LAP SPLICE OF UNIT IF POUR IS STOPPED FOR
SCHEDULE (GEN. STRUCT. MORE THAN ONE HOUR
NOTES) FOR LAP LENGTH
J- � MAX.HEIGHTOFPOUR=12-0". WAIT3T05
VERT. MASONRV REMF, SEE '�� MINUTESAND CONSOLIDATE WITH FLEXIBLE
PLANANDSCHEDULE . CABLEVIBRATOR. RECONSOLIDATEPRIOR
TO PLACEMENT OF NEXT LIFT
(APPROXIMATELV 20 MINUTE DELAV)
GROUT TO CONFORM TO ASTM
C4]6 SUBMIT MIX DESIGN FOR �
REVIEW. MAXAGGREGATESIZE=
3I8" W ITH 8" TO 11" SLUMP. DO NOT
USE SAME MIX AS USED FOR TIE
BEAMS PROVIDECLEANOUTHOLE,MINIMUM
SIZE 3"x3". OVERHANG MORTARAND
DEBRIS TO BE REMOVED FROM
�-��� INSIDECELLWALLS.SEALPRIORTO
GROUTING BUTAFTER INSPECTION.
NOTES:
1. DONOTGROUTUNTILMORTARHASSETSUFFlCIENTLV
TOWITHSTANDTHEPRESSUREOFTHEGROUT. WAIT
NOT LESS THAN 24 HOURS.
2 HIGH LIFT GROUTING DETAIL
'�. s.,o, ; ,��.._,._o..
GROUT TEST PRISM
� l l 'l
�� (4)-Sx8xi6CMU
COVER UNITS USING �I I ��� BLOCKS REQUIRED
ABSORPTNEPAPER I
TOWELMGW/TAPE ,,'����..� ���
3"x3"xi 5/8" WOOD BLOCK � FRONT BLOCK REMOVED
FOR CLARITY
3 GROUT TEST MOLD (ASTM C-1019)
�� s.,o, ; ,��.._,._o..
-�"����-._.. :� (2)-1"x3"SLEEVEANCHORS
I �- -:'�.11,� I - VERTICAL BAR POSITIONER
� SIM ILAR TO HB #RB PLACE
�-- -� � AT 8 0" O C. VERTICAL
�I I I I ����� �' APPLVPOLVURETHANE I� I I;�
SEALANT
— SLIP SET STYLE BY . �- .
HB AT 32" O.C.
VERTICAL
CROSS WALL TIE
GROUT VERTICAL CORE
SOLID TO BOTTOM OF
LMTELBLOCKBEFORE
POURING BOND BEAM I
1
� "� � ///� � CUT OUT BOTTOM OF
� � LINTEL BLOGK WHEf2E
LMTEL BLOCK � VERT. CORE AND REINF.
' � BAR CROSS BOND BEAM
BOND BEAM - VERT. REINF.
4 MASONRY DETAILS
.. 5�1C1 ; p• = 1• �••
BAR POSITIONER
� NO MORTAR IN
HEAD JOINT
INSTALL
POLVURETHANE
SEALANT AS RE�'D
� GALVAMZEDSTEEL
MESH WALL TIE AT
24" O.C. VERTICAL
INTERSECTING WALL
CONTROL JOINT
ZP Investments,
LLC Office
North Illinois St
Carmel, IN 46032
Owner
ZP Investments, LLC
11460 N Meridian Street
Carmel, IN 46032
317-705-5050
Architect
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
3� 7-633-4040
Structural Engineer
CE Solutions, Inc.
10 Shoshone Drive
Carmel, IN 46032
317-324-6024
Mechanical / Electrical Engineer
Heapy Engineering
3850 Priority W ay S. Dr #204
Indianapolis, IN 46240
317-571-8795
Civil Engineer
Civil & Environmental Consultants, Inc.
530 East Ohio Street G
Indianapolis, IN 46204
371-655-7777
SEAL � DATE O6/21/19
OpVI� Tq`
��1`�Q o\'siF f !�9
*/ No �*z
.�,PE19900097 ��
'D�� STAiE OF � �"
oF�S�ONAI EaG`� �' :, �� ry�
ninn�e� � ��..
r �
SHEETISSUE
1 Issued for Construction
r�, RAT I O
wvm�r rer a remai�ano�n�n�can�czmvn�c��nncanro�nce
nrvoswn ..a.xewar� r�u.wrxen.a,wwnrcrs ry
usFnss o o ru c orvureFunFumxou*aaoaua**vuwrvsvu*orw*o
ewecre�urx�x,ec, va��sarmvm�urvoamEn�ese.�x�e.
PROJECT NO. 18087.001
SHEET TITLE
TYPICAL MASONRY
DETAILS
SHEETNUMBER
S-701