HomeMy WebLinkAboutBldg L - Roof Truss LayoutIRC-2018, TPI-2014, NFPA-13, BCSI-06.(CAUTION - PLANS NEED TO BE UPDATED FROM IRC-2005 TO IRC-2018)20-10-10 ROOF LOADING @ 24" O.C. @ L/360, TL/240.METAL PLATE CONNECTED WOOD ROOF TRUSSES.DIMENSIONS ARE STUD TO STUD FRAMING. (FEET-INCHES-SIXTEENTHS)ALL BRACING (TEMP. & PERM.) AND BRACING DESIGN BY OTHERS, SEEPLAN AND BCSI.ALL CONVENTIONAL FRAMING, BLOCKING, SHEATHING, SHEAR HARDWARE AND RELATED CONNECTIONS BY OTHERS.TRUSS LUMBER IS KD19 SPF AND/OR SP-SYP, AS NEEDED, PER EACH DESIGN FOR THE REQUIRED LOADING AND DEFLECTION CRITERIA.(NO TREATED OR FIRE TREATED LUMBER USED. TRUSSES CANNOT COMEINTO DIRECT CONTACT WITH CONCRETE)BEAMS (DROPPED OR FLUSH AS NOTED) PER PLAN AND SEPARATION SHEATHING BY OTHERS.FRAMER TO FIELD VERIFY ALL PLUMBING, HVAC, SPRINKLER, ELECTRICAL AND ROOF DRAIN LOCATIONS PRIOR TO SETTING TRUSSES.PLUMBING VENT STACKS TO BE FIELD LOCATED IN BETWEEN TRUSSES AND STUDS WHERE POSSIBLE.TRUSSES CANNOT BE CUT, DRILLED OR NOTCHED.BLOCKING BETWEEN TRUSSES FOR PARALLEL WALLS BELOW BY BLDR.FRAMER TO SOLID BLOCK ALL POINT LOADS TO THE FOUNDATION.DISCLAIMER: BFS/PROBUILD/CARTER LEE COMPONENTS IS NOT THE; ENGINEER OF RECORD, PROJECT ENGINEER NOR CONSULTING ENGINEER.ALL PROJECT ENGINEERING IS THE SOLE RESPONSIBILITY OF ROTTMANN/COLLIER ARCHITECTS, THE ENGINEER OF RECORD.BUILDING LPRELIMINARYROOFALL CHATHAM MODELS- BASE UNITS ONLYHARDWARE34 - LUS24170 - H2.5AATTICACCESSATTICACCESSATTICACCESSATTICACCESSFIELD FRAME VALLEY PER PLAN BY BLDR.FIELDFRAME VALLEY PER PLAN BY BLDR.FIELD FRAMEVALLEYPER PLANBYBLDR.PARAPET WALL BY BLDR. PER PLANPARAPET WALL BY BLDR. PER PLANPARAPET WALL BY BLDR. PER PLANPARAPET WALL BY BLDR. PER PLANPARAPET WALL BY BLDR. PER PLANFIELD FRAME LOWPORCH ROOF BY BLDR.FIELD FRAME LOWPORCH ROOF BY BLDR.SADDLEBY BLDR.SADDLEBY BLDR.GE01GE01GE01GE01TG01T03T04T05T06T07T08T09TG02T10TG03CG01CG02J03J04J05J06T04T05T06T07T08T03TG01J03J07CG03TG04T11T12TG05CG04J08J04GE02(2)GE02(2)GE03(2)T01(6)T01(6)T02(6)T02(6)T02(3)T02(3)J01(10)J01(10)J02(3)J02(3)24-00-0024-00-0024-00-0024-00-0097-00-0037-00-002-00-002-00-00IRC 2018TPI 201420TCLL - 10TCDL -10BCDLONYX + EAST, LLC.Uptown at Village of W. ClayBuilding L, Roof1/4"=1'February 21, 2020JGJ20000862CUSTOMER:PROJECT:LOCATION:JOB #:DATE:DESIGNER: DESIGN INFORMATION:SCALE:9028 Old SR 67 SouthMooresville, IN 46158(317) 834-5380Truss Placement Guide1) This layout is intended for the purpose of truss locationand placement only. Refer to the building plans for actualbuilding construction.2) All dimensions shown 00-00-00 are in feet-inches-sixteenths.3) Trusses are spaced 24" on center unless otherwise noted.4) Do not cut or modify trusses.5) Refer to the individual truss design drawings for the locationof member bracing, uplift and truss end reactions.6) Installation of all temporary and permanent bracing isessential. See truss drawings, BCSI-B2 Summary Sheetand building designer requirements.IIICARMEL, IN. 46032