HomeMy WebLinkAbout12960 (1347) TriCo Sanitary Sewer PermitPermit Type
Project WO
Project Idame
Project Developer
Lift Station
Treatment Plant
Parcel Acreage
EDU in Gallons
Final
2017-1346
VWC 6003-B Uptown
Onyx and East, LLC
23 126th Street Station
CTRWD WWTP
0.063
310
one 317-844-9200 fax 317-844-9203 www.trico.eco
Subdivision
Section Plumber
Lot Number
Address Number
Address 2
Street
City
Zip Code
County
Village of Westclay
6003-B
1347
12960
Pettigru Drive
Carmel
46032
Hamilton
Local Sewer Charge - District Contribution 0.00
Plan Revlew and Inspectlon a 00 Builder Onyx and East, LLC
Appllcation Fee 150.00 Phone Number 317-672-7955
EDU Fee 1908.00 Owner
Interceptor Fee �•Q� phone Number
Other Fees Q �0
Fees Due 2058.00 Occupant
Invoice Number Phone Number
PLEASE NOTE: Installation of building sewer sha(I be per the specifications of the TriCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) wilf be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Main ID: YWC12-VWC11
Grease Trap Slab Foundation YES
Grease Interceptor Crawl Space
Manhole IDs USMH Wy�-�2 VWC-11 DSMH
Grit Interceptor Basement Lid Elevation 908.38 +� 907.26 ✓
Grinder Station First Floor Elevation 909.0� � 909.00 ✓
Water Service Carmel Utilities Basement Elevation
Ca/cu/afion is based on both Manho/e Lid E/evations and the e/evation of fhe First Floor 0.62 � 1.74 Ft.
_ _
Per Ordinance 9-13-99 and the elevations provided, the substruciure sha(I be pfumbed by: Not Applicable
�TriCo currently requires that an 181 inspection is pertormed and a Certificate of Compliance is issued prior to occupancy /
sale of a properrty. Please reviewr attached I/I Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the DevelopeNOwner.
The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below.
Plans have been submitted.
All fees have been paid. a,,�t�� ,�,,,�,,,���� 1
No certificate of insurance required.
No additional permits required.
No manhole core permit required.
The facility is not classified as a FOG facility.
{Notes) ��
�
��4�A � �
��"��� = 5lA��iV ��":
..�a�
By signing betow, I attest that I am fam' ' i th istricY ecifications and agree to accept responsibility for all work d ne under this permit.
Builder / Owner Signat Phone Number �% % ��- % 5/
Printed Name �j �,,y ����,.�l �,�`
Approved By
Permit is valid
-- '* 1 l 1_.
an, 45istric[ Ens�ineer 11 /26/2019
�-YEAR from the date issued. Perrtiit valid onl with TriCo seal in red ink.
Y
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per tateral unless atherwise approved by TriCo.
2. Foundation drains, sump drains, downspouts and other storm water drains shall never be connected to the sanitary sewer.
Site dewatering systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
porch or paved driveway, and the line passes an air test that is observed by TriCo. Contact TriGo for more information about
air testing requirements. The properly owner is responsible for testing costs.
4. TriCo shalf inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trico. The property owner or contractor must notify TriCo prior to backfilling. Inspections must be scheduled at {east 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the
scheduled inspection, a$10Q fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material. Contact your county health department for more information on
septic system and abandonment requirements, and to notify the department of any abandonment.
6. The following materials are acceptable for use in g�avity sewer lateral installation or repair:
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6� diameter
PVC pipe, pressure rated: SDR 21, ASTM D2241, 6" diameter
PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6" diameter
Alf gasketed joints shall meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanical joint fittings with proper hardware
SDR 26 gasketed repair sleeves or Indiana Seal shear guard
Femco and similar flexible couplings are only acceptable in certain circumstances and shall not be used without
prior approval from TriCo
Cleanouts: 6" threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable for use in low-pressure sewer lateral installation or repair:
HDPE pipe for directional drilling: DR 11 IPS, 1.25" diameter, PE4710
Connections shall be made via electrofusion or using polypropylene ar stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25° IPS full port �/4 tum fusible PE ball valve, rated 200 psi
Threaded swing check valve, 316 stainless steel, rated 200 psi
Contact TriCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a cleanout must be
added and the line is transitioned to 6" diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued
fittings are allowed between the building and the transition/cleanout. For all gravity lines, cleanouts shall not be spaced more
than 100' apart beiween the building and the sewer main. See TriCo's standard drawings for more information on cleanout
installation.
8. Bedding materiai shall be placed from at least 6 inches below to 12 inches above the pipe surtace. The trench shall be a
minimum of 18" wide with at ieast 6° of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstabie or unsuitable material found below and near the lateral, inc(uding any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #10-AWG solid copper tracer wire shall be laid on top of and run the entire length of the lateral. All splicing of tracer wire
shall use 3M splice kit model DBR/Y-6, King lnnovation Dryconn Direct Bury Lug Aqua catalog #90220, or TriCo appraved
10. Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by TriCo prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SDR 21 pipe, a ductile iron gasketed mechanical couplings must be used.
11. Laterals less than 5' deep shall be at least 24" from the property line, Laterafs more than 5' deep shall be at least 36" from
the property line. Where the lateral runs in close praximity to the property line the property comers must be accurately
staked by a professional land surveyor priar to inspection.
12. Laterals running parallel to a building or structure shall be at least 36" from the face of a crawl space or slab on grade
foundation and 60° from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TriCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
contractor should call to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to TriCo's sewer system may be tested, inspected, or televised at TriCo's discretion, and must.
remain accessible and properly maintained.
14. Call 811 or 1-800-382-5544 before you dig_ For more information go to www.indiana811.org.
TriCo Regional Sewer Utility
10701 North College Avenue Suite A
Indianapolis, lndiana 46280
Phone (317�844-9200 Fax (317}-844-9203
Revised 03/19l2019
' TriCo Regional Sewer Utilit
y
10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residenfial !& 1 Permit Ordinance 92-08-08
Lafera! Locafion Owner / Occupant /nformation
Address Number 12960 Owner
.. _ _ .......
._.... ._. _... ..
Address 2 _ . . . . . ... .... . . . . _. . . _
�. .... . __. . ..... . ....... First Name _
_ _ _�...
Street Pettigru Drive . . . . _ .. ....
... ._ ..... .. _ .. . _
.. _ . . . . _ ... . . . . ... . . . . ... . . . . . Last Name
._ .
City Carmel phone Number
__. ._.. . .
_ ...
State � N _ . .
_ _ . . . . .. . _ .. .... . .. . . . .. . .. . . . . . . . . ... . _ ... . .. . Mobile Number _.
Zip Code 46032 . . . . . . .. . . . . ._ . ._ .. . ..
_... _.. .._.._... _ . . ._. . .. ._.. Fax Number
Subdivision Village of Westclay . .. �...
_ .. ..
._._...... ... ....... ................... .. ......_ . Email Address
.. .
Section Number 6003-B .. _ ..
..._..._� .........................�_......_...__................. _..
Lot Number 1347
Permit Information Owner Address if Different
Address Number
. . . . . . . . . . . . . .___ . . . . . . . _ _ . . .
Address 2
_ ._......... . ........... ...__ ._...__..
....._..� ........ . ..... .
Street �
. . .... .... . .... . . . ... .._..._.........._.. ...._.
City
___ .............. ....... _...._....... .........___ .. ................ _...._.
State
. . . . . _ . . . . . ... ... . . . ._ . . . . . _ . . . .. . . _ .__ . . . . ._ . .__
Zip Code
_ ............. . . _.. � _ __._.
Builder Information
Builder Onyx and East, LLC
_ __ . ... _ . .. ......... .. . __ _...
Phone Number 317-672-7955
_ . ..... ... _.
Facilify Features and Addition Information
Slab Foundation YES Square Footage
_ _ ......_.. . �. . . . _...... .... .. .
.. _ . ._ . . . . . . _.. . . . . .__ . . . . . . . . . _
Crawl Space Water Type Carmel Utilities
.__. ..... ._._ _.._ .._..... __ ....... ._........ .... ....... _.._ ..... __ ..... _ .....
_
asement Basement Status Not Applicable
. .. . . .. ........ __. .. _ __.... ..._.._.
Cleanout .YES Main 1D VWC12-VWC11
... .. . _ .............. ......_........ ............... ...
_ . __
Ejector Pump Lift Station 23 126th Street Station
.. ...... . ... ......_._..._ ..... . ..._..._.. _ ... ....... ...... .... _....
Sump Pump
_ _.......,.. . _......__ .�.. ...... _ ............_..... ._........ ........._
Grinder Station
Program Specifications
� This program requires prior to the sale/occupance of a property that the property owner/builder notify TriCo and
schedule an inspection. The inspection will verify that:
' Downspouts are not connected to the sanitary sewer
■ The sump pump is not connected to the sanitary sewer
' Cleanout caps are in place and watertight
■ No yard drains are connected to the sanitary sewer
■ There are no sinkholes or other indications that the sewer lateral is leaking
■ 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
■ If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow up ins, ection. If a certificate of compliance is not issued within 30 days of the
change in ownership, a sewer surcharge a�$20 per month will be assessed and added to the sewer bill.
-,.-
Owner / Occupant Si�nature: Date: �" l".�
�
Approved By: '` Date: j 2� 2, % 2� �
d �,
��.� ��� � � �����_��
HWC _ PLC�T PLA
N
� �n, 9 �����,����r� `� �
J�" �`����
�
�
�
�
�
�
�
M
�
1
b
x
�
�
�
�
�
I�
�
0
�
M
�
�
s
�
�
.�
€
f
3
��
�'
� � �
� � ��
�' � i
,�1 m � �
'� !
��
�
� �
(� �
i� �
1_ i �
� M�' —.r
I ' �
i
1�
�
I ' � r`'
�
3 � N d=
�� � �
��
� � W
� � �
I �
I tn
�' �-- r�
{ ;` M
I � � N
3 � �
i
�
�p � i' ',', t�^
��
., ,
�
��
WATER METERS
� 135�
Q�'
��E 3,009 S.F.
0.069 AC.i
�A�#� —.....�,...
RIM=908.38
Nso•oo'oo'�E 79.�0'
m�
�� �
�a � �
� w �
� �
�
� N �'
t—
�
�
� a
►� � �
� �
d- o
� �
wa�� Z
WALK
�
w c�0
�; � �
��
m�
FO '— �,
ABBREVIATIQNS
A.E. — ACCESS ESMT.
A,[3.U.S.E. — ACCES�, DRAINAGE, UTILITY & SEWER E5MT.
�.�A.P.E. — BEST MANAGEMENT t'RACTICE ESM7.
B.T.L. — BUiLD 70 LINE
C.A. — COMMON AREA
D.U.&S.£. — DRAINAGE, UTiLlTY & SEWER ESMT.
ESMT. — EA5EM�NT
LAT. — LATERAL
*MF�E — MINIMUM �tN{SHED FLAOR El.EYATION (P�R CQNSTRUC�iQN PLANS)
M�PG — MlNIMUM FLOOQ PROTECTiQN GRADE (PER CONSTRUCTtON PLANS)
�a�. -- �a�c�
R f W — RiGHI'-4F—WAY
"ihis drawing is not
intended to be
represenied os o
retracament or
original boundary
survey, a route
survey, or a Survey�or
Location Report."
L�GEND
xxx.xx PROPOSED GRA�E
� AS—BUItT GRADE
■ CURB fNLET
� BEEHIVE INLET
i MANHOI..E
ti' WATER HYDRANT
9 WAIER VALVE
s SANI7ARY 5EWER
�T--�--� STORM SEWER
w WATER MAIN
a 5AN. — SANITARY �N(}TE: CONTRACTOR TO VERIFY �1RlSQIC11�lAL REQUIREbi�NTS F4R 'MFFE' WITH RELATED TO SEN1�R
Z S.6.L — SETBACK LIN� t1���1�S. STANDARD IS TO 1 FOOT ABOVE UPSTREAM OR DOWNSIREAM MANHOLE CASTING ELEVAT10N5.
m
�- S.F. — 5QUAR� FEET *Note: Improveme�ts shown per development plan, areu sfr�1 under canstructio►�. B�chmark Elevafwn, Water
SSD -- SUB—SURFACE DRAIN 1-aterals, Sanitary Laterois, and As—built grodes are depicted from post cons#ruction measur�nents taken in
� TC -- TOP OF GASIING March 2Qt8, Qfher information is depicted per the latest vers►an of proposed consfn��tion plans and is subject
� to change. &quore footage for the lats are listsd fa� ihe area of the overall bt and not the square footage of
the buildi�g unit footprints.
� ov�R PLOT PLAN - BTJILDING „L„ DRAWN 8Y
Q OE VILLAG� OF VVESTCLAY LLC
� 4b0 VIRGIN�A AVE. REPLAT OF VILLAGE OF WESTCLAY MGJ � N
� IIVDz�vAroLls, zrt 462�3 SECTI4N 60�3-8 CHECKED 8Y ��
� PAKT (JF BL(7►CK C �� � r-
��vc�n�Exnv� VILLAGE OF WESTCLAY UPTOWN DA?E z�
� 135 N. �ENN5YLVANIA ST, 5UTI`E 28U0 RE—PLAT OF` BL4CK "9" �'� /'� �/�Q �� p N
S IND�ANAPOLIS, IN 46 2 04 Instrument #2019056986 SCAL.E
0. 317�347-3663 P.C. , 5iide PAGE 1 �F � �"= 20'
�
� ��
� �.�
��
�
��
�,������� �G����t ��w�R��
' ,�� ,��j� �.� �� �O�` �Z . Z.'�`p �l
�.Y `* �\ \ � �� �` p ~�~ o � � 1
� � � �� ��
� . � `�� ��` u �.• �' � � °
� �..._'
� _j
� �j
f� t/)
a�
g9'�'8'4i "W 79.14' :
5' U.E. �
.____ ___.. ,__._ ____. �...,. _,._,. •
�,,, 1347
ie � 0.063 AC f
SAN. LAT.
WATER M�7ER ��a � O
sg�•4�'0� "w 7s.� o'
N �'�"'
� t,��� 1348
�� s� ��. 1,925 S.F.
0.044 AC.t
� WATER METER
SU.7��SiQ 1 ��� ! �7. t US
� C�EIlH 4w�r -
�° SAN. LAT. T�% �PAQ=908.8
� � WAiE� MET�R M�'PG-9Q8.4U
� 1349
� � 1,925 S.F.
( 0.044 AC.t
� _ S89'48'01 "W 79.10'
i...Z'9
� � I �
� � � C17
rn �`' c� a
�
t'� o Q
�
�
GRAPHIC SCALE
0' 10' 2Q' 3p`
��� � zo�
W
�
�
�
�
�
�
�
��
I , ��i) �
45 1/2 R/W (EXISTING)