HomeMy WebLinkAbout12956 (1349) TriCo Sanitary Sewer Permit,
. _ . ...,�,..y
Residential
Permit Type
Project WO
Project Name
Project Developer
Lift Station
Trea#ment Plant
Parcel Acreage
EDU in Gallons
VWC 6�03-B Uptown
Onyx and East, LLC
23 126th Street Station
CTRWD WWTP
0.044
310
Local Sewer Charge - District Contribution
Plan Review and Inspection
Application Fee
EDU Fee
Interceptor Fee
OtherFees
Fees Due
Invoice Number
0.00
0.00
150.00
1908.00
0.00
0.00
2058.00
Lot Number
Address Number
Address 2
Street
City
Zip Code
County
Builder
Phone Number
Owner
Phone Number
Occupant
Phone Number
1349
12956
Pettigru Drive
Carmel
46032
Hamilton
Onyx and East, LLC
317-672-7955
PLEASE NOTE: lnstallation of building sewer shall be per #he specifications of the TriCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling wi#h stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwaier, shall be permitted to enter TriCo's sanitary sewer system. TriCo wil! assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Main ID: VWC12-VWC11
Grease Trap Slab Foundation YES
Grease Interceptor Crawl Space Manhole IDs USMH vwc_t2 VyVC-11 �s
Grit Interceptor Basement Lid Elevation 908.38 � 90726
Grinder Station First Floor Elevation gpg_pp f 909.00
Water Service Carmel Uiilities Basement Elevation
Calcu/afion is based on bofh Manho/e Lid E/evafions and the e/evation of the First Floor 0.62 1.74 Ft.
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Not Applicable
TriCo currently requires that an f&t inspection is pertormed and a Certificate of Compliance is issued prior to occupancy /
sale of a properrty. Please review attached I/I Permit.
_� Manholes shall remain accessible at all times. Buried manholes will be corrected by the DevelopeNOwner.
�The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below. `nea�►"'���'�+��;"�a,�
��
Plans have been submitted. �,��"���'"��
All fees have been paid.
No certificate of insurance required.
No additional permits required.
No manhole core permit required.
The facility is not classified as a FOG facility.
(Notes)
By signing beiow, I attest that I am familiar " District's s� cations and agree to accept responsibility for all work done under this permit.
Builder I Owner Signature - Phone Number � C
Printed (Vame �~ �,.�,,,�
Approved By
Rvan Ha D� trict En�ineer 11 /26/2019
Permit is valid for NE- EAR from the date issued. Permit valid only with TriCo seal in red ink.
I"1YGI ING v71,11LC /"1 inaianapons, inaiana 4ti1tiU phone 317-844-9200 fax 317-844-9203 www.trico.eco
SANITARY SEWER PERMIT 9999'135�1
Final Subdivision Village of Westclay
2017-1346 Section Number 6003-8
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per laterai unless otherwise approved by TriCo.
2. Foundation drains, sump drains, downspouts and other storm water drains shall never be connected to the sanitary sewer_
Site dewatering systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
porch or paved driveway, and the line passes an air test that is absenred by TriCo. Contact TriCo for more information about
air testing requirements. The property owner is responsible for testing costs.
4. TriCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trico. The property owner or contractor must notify TriCo prior to backfilling. Inspections must be scheduled at least 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on site for the
scheduled inspection, a$100 fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system cantents or effluent shall never be discharged ta the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material. Contact your county health department for more information an
septic system and abandonment requirements, and to notify the department of any abandonment.
6. The following materials are acceptable for use in gravity sewer lateral installation or repair:
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6" diameter
PVC pipe, pressure rated: SDR 21, ASTM D2241, 6n diameter
PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6" diameter
All gasketed joints shal! meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanical joint fittings with proper hardware
SDR 26 gasketed repair sleeves or Indiana Seal shear guard
Femco and similar flexible couplings are only acceptable in cerkain circumstances and shall not be used without
prior approval from TriCo
Cleanouts: 6n threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable far use in low-pressure sewer lateral installation or repair:
HDPE pipe for directional drilling: DR 11 IPS, 1.25" diameter, PE4710
Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25° IPS full port 1/4 tum fusible PE ball valve, rated 200 psi
Threaded swing check valve, 316 stainless steel, rated 200 psi
Contact TriCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed 3' in length before a cleanout must be
added and the line is transitioned to 6" diameter SDR 35 PVC pipe. Glued jaints are not allowed after 3'. No additional glued
fittings are allowed between the building and ths transifion/cleanout. For all gravity iines, cleanouts shall not be spaced more
than 100' apart between the building and the sewer main. See TriCo's standard drawings for more information on cleanout
installation.
8. Bedding material shall be placed from at least 6 inches below to 12 inches above the pipe surtace. The trench shall be a
minimum of 18" wide with at least 6° of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #10-AWG solid copper tracer wire shalE be faid on top of and run the entire length of the lateral. AI! splicing of tracer wire
shall use 3M splice kit model DBR/l'-6, King Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or TriCo approved
10. Laterals shall be installed at �east 20' from water wefls unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by TriCo prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SDR 21 pipe, a ductile iron gasketed mechanicat couplings must be used.
11. Laterals less than 5' deep shall be at least 24" from the property line, Laterals more than 5' deep shall be at least 36° from
the property line. Where the lateral runs in close proximity to the property line the property corners must be accurately
staked by a professianal land surveyor prior to inspection.
12. Laterals running parallel to a building or structure shall be at least 36" from the face of a crawl space or slab on grade
foundation and 60" from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TriCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
cont�actor should cal[ to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to TriCo's sewer system may be tested, inspected, or televised at TriCo's discretion, and must
remain accessible and properly maintained.
14. Call 811 or 1-800-382-5544 before you dig. For more information go to www.indiana811.org.
TriCo Regional Sewer Utility
107�1 North College Avenue Suite A
Indianapolis, Indiana 46280
Phone (317)-844-9200 Fax (317)-844-9203
Revised 03/19/2019
TriCo Regional Sewer Utilit
y
10701 N. College Avenue Suite A Indianapolis, Indiana 46280 phone 317-844-9200 fax 317-844-9203 www.trico.eco
Residenfial 1& 1 Permit Ordinance 12-08-08
Lateral Location Owner / Occupan� Information
Address Number 12956 Owner
... _ . ..
. .._
Address 2 _. .. _ . _
_ _ .
_ _ . _ . . . . . ... _ . . . .. First Name .
. ._. .. _.
Street Pettigru Drive . _ . . . . . _. _ . . ... � . . ... . ..
_ . . ...... , ..... .
_. _ _. . _ ..... _ _ .. ......._ . Last Name
_.._.... _ ...._ .
City Carmel
........... .. Phone Number
... ._.._ . ..
State . . . . . .... . _ . .
_... _ .
.. ._.... ._..._ ....._. ... .. ... . . ...N Mobile Number
. . ..
Zip Code 46032 .. _.. _ _........ .......
_ ... . . Fax Number
_ . _.. .
Subdivision Village of Westclay -
.
. . . . .. . . . __ _. . . . ___ _ . . . . Email Address
._... _. ..
Section Number 6003-B _ _
_ _ �........._ ............. ......... . ...._..._..._......_....
Lot Number
�1349
Permif Information
Owner Address if Different
Address Number
........
. ._....._.
Address 2
_ .......
_. ._......
_ ... .............__..._ .. .
Street
.......... .. _ .. . .... .
City. . . ._ . . ._ . . . . . . . . ._ .
............ ..__. . ._._.......... .... . ......... ...._..._...............
State _.
. . . . . . . . . . . . . ... . . . .. __ _ . . . . . _ ..__ . . .
.. ..
Zip Code
_..�... . ......�....._ ................ ........ .. ..__ . ._._
Builder lnformation
Builder Onyx and East, LLC
_.. _......_..... _._ _ ..
Phone Number 317-672-7955
. . . _ _ ._ . . . . . _ __ . .
aci �ty Feafures and Addition lnformaiion
Slab Foundation YES Square Footage
.. _ _ .
.._... . ......._.. . ..
Crawl Space Water Type Carmel Utilities
.... _.. ._.... .. .._. ...... .
. ., _... _... _
asement Basement Status Not Applicable
. . ._ . . _ . .. . . . _ . . .
_. _. __. . .
eanout YES Main ID VWC12-VWC11
.._.. .... _ _ .. .. . .. __.
.._ ..... _.. _.._.._.._ _._.. . _.._
jector Pump Lift Station 23 126th Street Station
. _. _. . ... _. . ... ... .. .... . ........
...._ . _... ... . . _
ump Pump
_ .. . . . __ _ _ _ .. . . .... . . .. _ . . . . . _ . . . . _. __._... . ..__...
Grinder Station
Program Specificafions
� This program requires prior to the sale/occupance of a property that the property owner/builder notify TriCo and
schedule an inspection. The inspection will verify that:
' Downspouts are not connected to the sanitary sewer
■ The sump pump is not connected to the sanitary sewer
' Cleanout caps are in place and watertight
' No yard drains are connected to the sanitary sewer
• There are no sinkholes or other indications that the sewer lateral is leaking
■ 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
■ If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow u' ction. If a certificate of compliance is not issued within 30 days of the
change in ownership, a sewer s arge of 20 per month will be assessed and added to the sewer bill.
.-�
_ �/ r
Owner / Occupant Signature: i� Date: �� ---� �--- �C.-;
Approved By: � .,a Date: � Z,. Z� 2p�i
v �
�3 �
� m
��
N �N
,�*1: �a'i.
.
►.:. ,i
r�„r� I
• �
tiM , •
i 1
�I
(
+�� � �
� ` �
��
� �
,'� �° � I
�
�
�
�
�
s
P
'�O
�
�
�
M
�
,
�
�
�
�
I G�i
�
�
» �.-�► �
� j �
� I`� u.i
� � � '� ¢
� � ���
�' ~� �
- ( ' � � C�
� �� �r
I'
��
f +
� N
�� � �
1'¢� I�-
� � � � �
� j r CV �, .r.
�� � �
� � �
� �_
I ps o0
I � C� Q
} - r— �y �
r � � M
I{ d N o
� � �
3 � f �
� � �
o r -i•a. _
` _�_ ,� v ,.�,
, � — _�
1 ' - �f'�
► � �
�� � ; ��
�; �
° 0
�
� �
�
�
� �
� — ��
U ..�- ".�
M
S
�
0
PLOT PL.��.N
�J V�G.
B9'48'�'W 79.10'
____ ___w___
� � T S�U.E_.�. _..._ �
� 1�47 -
�,742 S.F:
4.063 AC.f
SAN. LAi'.
WA7�'R �1�TER
S89'48'01 "W 79.10'
�`.�'N � 348
ouc
� SA�t. u�T. 1,925 S. F.
0.0�44 AC.t
• WATER METER
S89'48'01 "W 79.10'
C��lY �jvt� — .
• SAN. LAT. 'r`�� PAD=908.8
• WATER MEI�� M�PG=908.4Q
1349
1,925 S.�'.
�Z�'� o.a� Ac.�
S89`48'01 "W 79.1 Q'
�
, :�
,�
•.
r
..� .
��-�. � �..' I .'.� 1'
_ .�i�'�:�`�
�� �' ���,
. ���:�
�.:�i��.
,�,,��, , �`.• ,�! ..
���� _.wl�! —
� t
, ;
• ._. ', ���
9./.� ��V' �� i'{'1�����
Vltt'f.C�C 17Ct'lirT�
a' �o� Za 30�
� �� = zo�
�
�
�
�
�
H
i�A �
r-�•�t
�
�a
�- �
� �� � �
,
WAtx -�� q D S
� ��- �:
wA�x 45' 1 /2 R%
"'- WATER METERS
�m
� N � 135Q �
� 3,00s s.F. �; � �
o.oss Ac.f � �
AN. �
� �0 " c�
RiM=908.38
N9o•oa'oa"E 79.� o' --�
�' ABBREVIATIONS
�
o A.E. — ACCESS ESMT.
� A,D.U.S.E. — AC�ESS, DRAI�fAGE, UT(L!� & SEWER ESMi.
g B.�I.P.E. — BEST MANAGEMENT PRACTICE ESMT.
;� B.T.L — BUILD TO UNE
M C.A. — COMMON AREA
� D,U.&S.E. — QRAINA6E, 11TILITY dc SEWER ES�iT.
� ESMT. — EASEMENT
� LAT. — IATERAL
,� *MFFE — MINIMUM �lNISI�iED FLflOR ELEVATION (PER CONSTRUCTIUN PLANS)
� M�PG — MiNIMl1M FLOOD PROTECTION GRADE (PER CONSTRUCTiQN PLANS}
� P4R, — PQRCH
3 R/W — RIGHT—O�--WAY
, ��
�
(�XISTING}
"This drawing is not
intended tv be
represented as n
retracemcnt or
arigfial boundary
survey, a rat�te
survey, o� a Surveynr
Looation Report."
LE��ND
xxx.xx . PROFOS� GRADE
� AS-8UlLi GRADE
■ CURB iNL�T
� BEEHIVE (NLET
! MANHOLE
'r WAT�R HYDf�ANT
9 WA7ER VALIIE
5-�--- SANITARY 5EYYER
� STORM SEWER
w WATER MAf N
£ SAN. — SANI7ARY #�Q� ���ACiQR TQ VE�IFY .�1RISQICTIONAL REQUIREMENTS Ff�t 'f�FFE' WITH RELATEU TO SEWER
z S.B.L -- SETBACK LIN� �T1��1�� �TANDARD 1S TO 1 F007 ABQYE UPSTREAt�I � DOWNS7REAM MANHOLE CA5i1NG ELEVAT10N5.
� S.F. — SQUAR� FEET *Not�: Impfovements shawn per development plart, area st�i under ca�stntction. Benchmark Elevation, Water
SSD -- SUS--SURFACE pRAIN Latet��ls, S�nitary i.aternis, and As--huilt grodes are depicted from post constructian measurements taken in
� TC -- TOP OF CASIING March 2018, Other infcxmatian is depicted per the latest versian of proposed caistructwn plans and is subject
� to change. Square footQge for fhe lats are listed for the area of the overaU lot and not the square footage of
the bttildinq unit footprints.
Q E`TTLLAGB OF WESTCLAY LLC PL�T PLA.N - BIJIIIDING "L." DRAWN 8Y
°` 46fl VjRGIN�A Ay�. REPLAT C�F VILLA.GE O�' WESTCL,A`Y MGJ W�
�, IlVDz,A.N�oL�s, IN 46203 SECTION 6p03-B CHECKEO BY � M
� PART OF BLOCK C �e � �-
��vC E��INEERIlVG �-LAGE OF WESTCLAY ,UPTOWN dA� m�
RE—PLAT OF St�CK 9 11l13/2Q99 p o
� 135 N. PENi�SYLVANIA ST, SUI'I"E 2800 �nstrument #2019056986 SCALE ��
Q INDIANAPOLIS, IN 46204
� 317-347-3663 P.C. , SlIdB PAGE 1 �F � �"= 2�'