M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). March 30,2020 Liu, Xuegang Pages or sheets covered by this seal: I40810472 thru I40810502 My license renewal date for the state of Indiana is July 31, 2020. J19904093 Pyatt Builders - 50 TG - Reindl IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810472 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-xOSUYuP6QPyQmwpMRhJyh88uyYyqiiwtzyUuwszViCj Scale = 1:41.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 17-10-0 17-10-0 -1-0-0 1-0-0 8-11-0 8-11-0 17-10-0 8-11-0 18-10-0 1-0-0 0-5-124-11-40-5-126.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.03 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 14 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-10-0. (lb) - Max Horz 2=-64(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 24, 25, 26, 27, 19, 18, 17, 16, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 21, 23, 24, 25, 26, 27, 20, 19, 18, 17, 16, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-3-0, Exterior(2N) 2-3-0 to 8-11-0, Corner(3R) 8-11-0 to 11-11-0, Exterior(2N) 11-11-0 to 18-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 24, 25, 26, 27, 19, 18, 17, 16, 14. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE02 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810473 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-7WdesfX?qnLsbc9UaV?XdS5mAziYnhjUU9ezpjzViCY Scale = 1:24.5 1 2 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 14 4x6 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-7-0 11-7-0 -1-0-0 1-0-0 5-9-8 5-9-8 11-7-0 5-9-8 12-7-0 1-0-0 0-7-124-6-10-7-128.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-0-2], [12:0-2-1,0-0-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.06 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 13 13 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-7-0. (lb) - Max Horz 2=-71(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 18, 19, 20, 16, 15, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 12, 17, 18, 19, 20, 16, 15, 14 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 1-9-8, Exterior(2N) 1-9-8 to 5-9-8, Corner(3R) 5-9-8 to 8-9-8, Exterior(2N) 8-9-8 to 12-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12, 18, 19, 20, 16, 15, 14. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE03 Truss Type Common Structural Gable Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810474 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:17 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3ulOHLZGMPbaqwIsiw1?jtAyonDyFWAnyT74ubzViCW Scale = 1:37.4 1 2 3 4 5 9 8 7 6 18 19 20 21 22 23 6x8 5x12 4x10 3x8 2x4 2x4 3x6 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 8-6-0 8-6-0 8-10-0 0-4-0 17-8-0 8-10-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 0-7-126-6-70-7-128.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [4:0-5-4,0-2-8], [5:0-3-8,Edge], [5:0-1-12,0-3-8], [6:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.73 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.40 0.00 (loc) 5-6 5-6 5 l/defl >517 >266 n/a L/d 240 180 n/a PLATES MT20 Weight: 76 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x6 SPF No.2, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-9-8 except (jt=length) 5=Mechanical. (lb) - Max Horz 2=101(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 5, 8 except 7=-170(LC 18) Max Grav All reactions 250 lb or less at joint(s) 9 except 6=829(LC 18), 6=642(LC 1), 2=305(LC 1), 5=393(LC 18), 8=323(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-297/51 WEBS 4-6=-371/40, 3-8=-255/88 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 17-8-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5, 8 except (jt=lb) 7=170. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE03A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810475 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:20 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-TTQXvNb8fKz9hN1RN2biKWobV_MdSxODeRMkVwzViCT Scale = 1:36.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 26 25 24 23 22 21 20 19 18 16 15 17 4x6 5x6 5x8 5x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-10-0 8-10-0 13-11-0 5-1-0 17-8-0 3-9-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 0-7-126-6-70-7-128.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-3-8], [2:0-3-8,Edge], [14:0-3-8,Edge], [14:0-1-12,0-3-8], [21:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.28 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 15 15 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud WEDGE Left: 2x6 SPF No.2, Right: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 13-11-0 except (jt=length) 14=Mechanical, 17=0-3-8. (lb) - Max Horz 2=101(LC 26) Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 24, 25, 26, 20, 19, 17 except 18=-122(LC 20) Max Grav All reactions 250 lb or less at joint(s) 21, 2, 14, 22, 23, 24, 25, 26, 20, 19, 18 except 17=472(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 24, 25, 26, 20, 19, 17 except (jt=lb) 18=122. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 87 lb down and 21 lb up at 15-8-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE03A Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810475 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:21 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-xg_v7icmQd50JXcdxl6xtjLmFOhsBOeNt55I1NzViCS LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-8=-60, 8-14=-60, 2-14=-20 Concentrated Loads (lb) Vert: 15=-87(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810476 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-IdnoAQgvEAkIPIUbkJi6an2fOPT5sfN60Np3iazViCN Scale: 1/2"=1' 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 4x6 3x4 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-10-8 8-10-8 -1-0-0 1-0-0 4-5-4 4-5-4 8-10-8 4-5-4 9-10-8 1-0-0 0-7-123-7-40-7-128.00 12 Plate Offsets (X,Y)-- [2:0-2-1,0-0-2], [10:0-2-1,0-0-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.02 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 11 11 10 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 38 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-1, Right 2x4 SPF-S Stud 1-6-1 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-10-8. (lb) - Max Horz 2=-57(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 10, 15, 16, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 14, 15, 16, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 1-9-4, Exterior(2N) 1-9-4 to 4-5-4, Corner(3R) 4-5-4 to 7-5-4, Exterior(2N) 7-5-4 to 9-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10, 15, 16, 13, 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE05 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810477 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:35 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-XMqC3VnY7xs1_hhKliMDRgwB31X8Tj8R5GU1WZzViCE Scale = 1:13.5 1 2 3 4 6 5 3x4 3x4 3x4 2x4 2x4 -1-0-0 1-0-0 3-3-8 3-3-8 0-5-122-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.02 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=3-3-8, 2=3-3-8, 6=3-3-8 Max Horz 2=52(LC 9) Max Uplift 5=-4(LC 9), 2=-22(LC 12) Max Grav 5=32(LC 1), 2=144(LC 1), 6=136(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 1-11-8, Exterior(2N) 1-11-8 to 3-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE06 Truss Type Monopitch Supported Gable Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810478 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:40 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-uKe56CqhxTVJ5SZHYFyO8kd1v2DF8?OAEYCoCmzViC9 Scale = 1:9.8 1 2 3 4 3x4 3x4 3x4 -1-0-0 1-0-0 3-3-0 3-3-0 0-3-151-4-154.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=3-3-0, 2=3-3-0 Max Horz 2=33(LC 9) Max Uplift 2=-23(LC 12) Max Grav 4=115(LC 1), 2=194(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE07 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810479 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:43 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-IvJDkEtZEOtuyvIsDNV5mMFZ0GG9LLJcxWQSp5zViC6 Scale = 1:12.3 1 2 3 4 6 5 7 8 3x4 3x4 3x4 2x4 2x4 -1-0-0 1-0-0 2-9-8 2-9-8 0-5-121-10-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.02 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=2-9-8, 2=2-9-8, 6=2-9-8 Max Horz 2=45(LC 9) Max Uplift 5=-3(LC 9), 2=-25(LC 12) Max Grav 5=40(LC 1), 2=133(LC 1), 6=99(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 2-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss GE08 Truss Type GABLE Qty 2 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810480 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:44 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-m5tbyauC?i?la3t2n50KJaojGgbY4n6l9AA0LXzViC5 Scale = 1:14.4 1 2 3 4 5 8 7 6 3x4 3x4 3x4 2x4 2x4 2x4 2x4 -1-0-0 1-0-0 5-11-8 5-11-8 0-4-42-4-14.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.07 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 2=58(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 7 Max Grav All reactions 250 lb or less at joint(s) 6, 2, 7 except 8=251(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 1-4-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss LAY01 Truss Type GABLE Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810481 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:45 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-EHR_9wuqm?7cBDRFLoYZrnKn03yKpEUvOqvZt_zViC4 Scale = 1:73.01234 8 7 6 5 3x4 3x4 3x4 4x6 2x4 2x4 2x4 2x4 0-2-6 0-2-6 4-5-5 4-2-15 5-5-6 1-0-1 5-5-6 5-5-6 17.89 12 Plate Offsets (X,Y)-- [1:0-1-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.54 0.03 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-6: 2x6 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins: 1-4, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 1-8. REACTIONS.All bearings 5-3-0. (lb) - Max Horz 1=123(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 6, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6, 8, 7 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 6, 8, 7. 8) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1, 8, 7. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T01 Truss Type Common Qty 7 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810482 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:47 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BgZkabw4IcNKRXbdSDa1wCQ4JtVaH70Cr8OgyszViC2 Scale = 1:34.4 1 2 3 4 5 8 7 6 9 10 11 12 5x10 MT18HS 4x6 3x6 2x4 2x4 4x6 6-8-12 6-8-12 11-1-4 4-4-9 17-10-0 6-8-12 -1-0-0 1-0-0 8-11-0 8-11-0 17-10-0 8-11-0 18-10-0 1-0-0 0-5-124-11-40-5-126.00 12 Plate Offsets (X,Y)-- [2:0-0-12,0-1-9], [4:0-0-12,0-1-9] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.68 0.56 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.16 0.02 (loc) 2-8 2-8 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 57 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=64(LC 11) Max Uplift 2=-13(LC 12), 4=-13(LC 12) Max Grav 2=770(LC 1), 4=770(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1019/86, 3-4=-1019/86 BOT CHORD 2-8=0/797, 6-8=0/725, 4-6=0/797 WEBS 3-6=0/268, 3-8=0/268 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-11-0, Exterior(2R) 8-11-0 to 11-11-0, Interior(1) 11-11-0 to 18-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T01A Truss Type Roof Special Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810483 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:49 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-72gU?HxKqEd2gql0aecV0dVQWh75lxVVJStn0lzViC0 Scale: 3/8"=1' 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 3x4 3x4 4x8 5x12 8x8 3x4 3x4 3x8 3x6 6x8 3-11-0 3-11-0 6-11-0 3-0-0 8-11-0 2-0-0 17-10-0 8-11-0 -1-0-0 1-0-0 3-11-0 3-11-0 6-11-0 3-0-0 8-11-0 2-0-0 17-10-0 8-11-0 18-10-0 1-0-0 0-5-124-11-40-5-121-4-06.00 12 Plate Offsets (X,Y)-- [3:0-2-12,0-2-0], [6:0-8-0,0-0-1], [10:0-2-12,Edge], [11:0-4-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.81 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.38 0.12 (loc) 6-8 6-8 6 l/defl >999 >558 n/a L/d 240 180 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 3-12: 2x10 SP No.1, 4-9: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=64(LC 11) Max Uplift 2=-13(LC 12), 6=-13(LC 12) Max Grav 2=770(LC 1), 6=770(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1187/99, 3-4=-1432/111, 4-5=-1321/127, 5-6=-968/96 BOT CHORD 2-12=-41/982, 10-11=-116/2728, 6-8=0/752 WEBS 3-10=-1478/118, 8-10=0/904, 5-10=-32/940, 5-8=-270/70 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-11-0, Exterior(2R) 8-11-0 to 11-11-0, Interior(1) 11-11-0 to 18-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T02 Truss Type Common Qty 2 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810484 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:51 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-3RoFQzzbLrtlv8vOh3fz52aqaUwCDxunmmMt5dzViC_ Scale = 1:27.3 1 2 3 4 5 6 7 8 4x6 2x4 3x8 3x8 5-9-8 5-9-8 11-7-0 5-9-8 -1-0-0 1-0-0 5-9-8 5-9-8 11-7-0 5-9-8 12-7-0 1-0-0 0-7-124-6-10-7-128.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-3-8], [2:0-3-8,Edge], [4:0-1-12,0-3-8], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.41 0.32 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 4-6 4-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-3-8 Max Horz 2=-71(LC 10) Max Uplift 2=-14(LC 12), 4=-14(LC 12) Max Grav 2=523(LC 1), 4=523(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-552/65, 3-4=-552/65 BOT CHORD 2-6=0/368, 4-6=0/368 WEBS 3-6=0/283 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-9-8, Exterior(2R) 5-9-8 to 8-9-8, Interior(1) 8-9-8 to 12-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03 Truss Type Common Qty 12 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810485 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:53 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?qw?rf?rtS7T9S3npUhRATfCkIWuhpr4E4r_8WzViBy Scale = 1:34.7 1 2 3 4 5 6 7 8 9 10 11 12 4x6 5x12 2x4 2x4 3x8 3x8 8-10-0 8-10-0 17-8-0 8-10-0 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 12-4-3 3-6-3 17-8-0 5-3-13 18-8-0 1-0-0 0-7-126-6-70-7-128.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-3-8], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-1-12,0-3-8], [8:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.30 0.69 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.13 -0.28 0.02 (loc) 2-8 2-8 6 l/defl >999 >770 n/a L/d 240 180 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=102(LC 11) Max Uplift 2=-9(LC 12), 6=-9(LC 12) Max Grav 2=767(LC 1), 6=767(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-918/41, 3-4=-717/53, 4-5=-717/53, 5-6=-918/41 BOT CHORD 2-8=0/694, 6-8=0/694 WEBS 4-8=-9/558 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 18-8-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03A Truss Type Common Qty 9 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810486 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:55 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-yC2mFK05P4NBOlCAwujvFulXW5BB9jINhOK5DOzViBw Scale = 1:32.3 1 2 3 4 5 6 7 8 9 10 11 4x6 5x12 2x4 2x4 3x8 3x8 8-10-0 8-10-0 17-8-0 8-10-0 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 12-4-3 3-6-3 17-8-0 5-3-13 0-7-126-6-70-7-128.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-3-8], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-1-12,0-3-8], [7:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.35 0.70 0.31 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.29 0.02 (loc) 6-7 6-7 6 l/defl >999 >729 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=Mechanical Max Horz 2=101(LC 11) Max Uplift 2=-10(LC 12) Max Grav 2=768(LC 1), 6=705(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-921/41, 3-4=-720/53, 4-5=-721/55, 5-6=-923/44 BOT CHORD 2-7=0/696, 6-7=0/700 WEBS 4-7=-13/564, 5-7=-252/97 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 17-8-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03B Truss Type Roof Special Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810487 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:45:58 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-MnjuuM2_i?mmFDxkc1HctWN3JJF6M0jpNLZlqjzViBt Scale = 1:39.8 1 2 3 4 5 6 7 10 9 8 11 12 13 4x6 5x6 3x4 5x12 2x4 4x6 4x8 4x6 4x8 8-10-0 8-10-0 16-6-14 7-8-14 17-8-0 1-1-2 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 12-4-3 3-6-3 16-6-14 4-2-11 17-8-0 1-1-2 0-7-121-2-136-6-71-2-138.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [10:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.63 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.32 0.02 (loc) 2-10 2-10 8 l/defl >999 >655 n/a L/d 240 180 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=Mechanical, 2=0-3-8 Max Horz 2=112(LC 11) Max Uplift 2=-10(LC 12) Max Grav 8=699(LC 1), 2=762(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-905/44, 3-4=-704/56, 4-5=-697/54, 5-6=-874/18, 6-7=-769/0, 7-8=-703/0 BOT CHORD 2-10=-18/684, 9-10=-3/675 WEBS 4-10=-9/530, 6-9=-553/41, 7-9=0/953 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 17-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03C Truss Type Roof Special Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810488 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:00 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-IAreJ24EEc0UUW57jSJ5yxSLZ6wrqve6rf2suczViBr Scale = 1:33.6 1 2 3 4 5 6 9 8 7 10 11 12 4x6 4x8 3x4 5x8 2x4 3x8 3x8 4x8 8-10-0 8-10-0 15-0-14 6-2-14 17-8-0 2-7-2 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 15-0-14 6-2-14 17-8-0 2-7-2 0-7-122-2-136-6-72-2-138.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [5:0-5-4,0-2-0], [8:0-3-8,0-1-8], [9:0-4-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.61 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.34 0.02 (loc) 2-9 2-9 7 l/defl >999 >614 n/a L/d 240 180 n/a PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=Mechanical, 2=0-3-8 Max Horz 2=123(LC 11) Max Uplift 2=-10(LC 12) Max Grav 7=699(LC 1), 2=762(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-900/45, 3-4=-703/58, 4-5=-745/37, 5-6=-830/31, 6-7=-667/9 BOT CHORD 2-9=-51/679, 8-9=-25/788 WEBS 4-9=0/472, 5-9=-292/69, 5-8=-556/62, 6-8=-21/1019 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 17-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03D Truss Type Roof Special Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810489 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:02 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-EYzPkk6UmDGBkqFWrtLZ1MXkZwcNImJPIzXzzUzViBp Scale = 1:33.4 1 2 3 4 5 6 10 9 8 7 11 12 13 14 6x8 3x4 3x4 4x6 6x10 3x8 2x4 3x8 4x8 8-10-0 8-10-0 13-7-7 4-9-7 17-8-0 4-0-9 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 13-6-14 4-8-14 17-8-0 4-1-2 0-7-123-2-136-6-71-10-131-4-03-2-138.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [8:0-3-12,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.61 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.36 0.03 (loc) 2-10 2-10 7 l/defl >999 >578 n/a L/d 240 180 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-9: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-5 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-15 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=Mechanical, 2=0-3-8 Max Horz 2=109(LC 11) Max Uplift 2=-8(LC 12) Max Grav 7=699(LC 1), 2=762(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-901/44, 3-4=-702/57, 4-5=-1539/86, 5-6=-1313/13, 6-7=-640/27 BOT CHORD 2-10=-63/680, 5-8=-1058/92 WEBS 4-10=0/301, 8-10=0/459, 4-8=-54/995, 6-8=-22/1351 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2R) 8-10-0 to 11-10-0, Interior(1) 11-10-0 to 17-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T03E Truss Type Roof Special Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810490 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:04 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-Bx498P7lIrWvz8OuyHN17nd2JkItmlLimH031NzViBn Scale = 1:32.5 1 2 3 4 5 6 9 8 7 10 11 12 4x6 4x8 3x4 5x8 2x4 3x6 3x6 4x8 8-10-0 8-10-0 12-0-14 3-2-14 17-8-0 5-7-2 -1-0-0 1-0-0 5-3-13 5-3-13 8-10-0 3-6-3 12-0-14 3-2-14 17-8-0 5-7-2 0-7-124-2-136-6-74-2-138.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [2:0-1-12,0-3-8], [5:0-5-4,0-2-0], [9:0-4-0,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.41 0.60 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.36 0.01 (loc) 2-9 2-9 7 l/defl >999 >590 n/a L/d 240 180 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=Mechanical, 2=0-3-8 Max Horz 2=147(LC 11) Max Uplift 2=-8(LC 12) Max Grav 7=699(LC 1), 2=762(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-902/36, 3-4=-700/47, 4-5=-690/45, 5-6=-694/37, 6-7=-640/43 BOT CHORD 2-9=-110/682, 8-9=-50/677 WEBS 4-9=-9/541, 5-9=-264/54, 5-8=-427/57, 6-8=-29/818 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 8-10-0, Exterior(2E) 8-10-0 to 12-0-14, Interior(1) 12-0-14 to 17-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T05 Truss Type Monopitch Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810491 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:05 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-f7eXMl8N28embIz5W?vGf?9Is7lBVIar_xldZpzViBm Scale = 1:13.5 1 2 3 4 5 3x4 3x4 3x4 3-3-8 3-3-8 -1-0-0 1-0-0 3-3-8 3-3-8 0-5-122-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8 Max Horz 2=52(LC 9) Max Uplift 4=-1(LC 9), 2=-26(LC 12) Max Grav 4=107(LC 1), 2=202(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T06 Truss Type MONOPITCH Qty 6 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810492 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:10 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-?5SQPTCVthG3h3s2JYURM2s9h8TPAZpa8DTOF1zViBh Scale = 1:9.8 1 2 3 4 3x4 3x4 3x4 3-3-0 3-3-0 -1-0-0 1-0-0 3-1-8 3-1-8 3-3-0 0-1-8 0-3-151-4-151-1-70-3-81-4-154.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.08 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=33(LC 9) Max Uplift 2=-28(LC 12) Max Grav 2=200(LC 1), 4=105(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T07 Truss Type MONOPITCH Qty 8 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810493 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:14 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-ushxFqF0xvnVAg9pYOZNWu1r1lrk6NpA3rRbOozViBd Scale = 1:12.3 1 2 3 4 5 6 3x4 3x4 3x4 2-9-8 2-9-8 -1-0-0 1-0-0 2-8-0 2-8-0 2-9-8 0-1-8 0-5-121-10-81-7-00-3-81-10-86.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=0-1-8 Max Horz 2=45(LC 9) Max Uplift 2=-28(LC 12), 4=-2(LC 9) Max Grav 2=185(LC 1), 4=84(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 2-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08 Truss Type Monopitch Qty 6 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810494 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:15 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-M3FJSAGeiDvLoqk0554c36ayP99GrnyKHVA9wEzViBc Scale: 3/4"=1' 1 2 3 6 5 4 7 8 3x12 3x4 3x6 3x4 3x4 5-9-10 5-9-10 -1-1-14 1-1-14 5-9-10 5-9-10 0-8-100-7-82-11-50-3-80-10-122-11-54.00 12 Plate Offsets (X,Y)-- [3:0-9-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.35 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.01 (loc) 5-6 5-6 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-1-8, 8=0-1-8 Max Horz 6=55(LC 12) Max Uplift 6=-15(LC 12), 8=-2(LC 12) Max Grav 6=311(LC 1), 8=199(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-6=-266/158 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-1-14 to 1-10-2, Interior(1) 1-10-2 to 5-5-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6, 8. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08A Truss Type Half Hip Qty 4 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810495 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:04:58 2020 Page 1 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-LCuB75BzGMKIGm8p61huuAamArPtTcicWjj4rezVhw3 Scale = 1:15.4 1 2 3 4 5 7 6 13 3x6 3x6 4x6 3x4 3x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 0-3-6 0-3-6 3-1-5 2-9-15 4-7-8 1-6-3 5-11-4 1-3-12 6-3-8 0-4-4 -1-0-0 1-0-0 4-7-8 4-7-8 6-3-8 1-8-0 0-4-41-9-90-11-142-6-00-11-141-3-104.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-2-4], [2:0-1-11,Edge], [4:0-3-0,Edge], [11:0-2-4,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.73 0.30 0.47 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.06 0.00 0.01 (loc) 2-7 2-7 6 2-7 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-10-8 max.): 4-7, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=606/0-3-8, 2=421/0-1-12 Max Horz 2=51(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-594/0, 3-13=-555/0, 4-7=-320/0, 4-5=-915/0, 5-6=-551/0 BOT CHORD 2-7=0/524 WEBS 5-7=0/862 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-160, 2-6=-20 Concentrated Loads (lb) Vert: 4=-310 2) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-50, 4-5=-150, 2-6=-20 Continued on page 2 March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08A Truss Type Half Hip Qty 4 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810495 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:04:58 2020 Page 2 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-LCuB75BzGMKIGm8p61huuAamArPtTcicWjj4rezVhw3 LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-300 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-120, 2-6=-40 Concentrated Loads (lb) Vert: 4=-290 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=44, 2-13=35, 3-13=24, 4-5=-76, 2-6=-12 Horz: 1-2=-56, 2-13=-47, 3-13=-36, 3-4=11, 5-6=29 Concentrated Loads (lb) Vert: 4=-207 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=20, 2-3=35, 4-5=-65, 2-6=-12 Horz: 1-2=-32, 2-3=-47, 3-4=-36, 5-6=-18 Concentrated Loads (lb) Vert: 4=-207 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-39, 4-5=-139, 2-6=-20 Horz: 1-2=-15, 2-3=19, 3-4=-28, 5-6=-27 Concentrated Loads (lb) Vert: 4=-289 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-35, 2-3=-39, 4-5=-139, 2-6=-20 Horz: 1-2=15, 2-3=19, 3-4=19, 5-6=21 Concentrated Loads (lb) Vert: 4=-299 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=19, 2-3=8, 4-5=-82, 2-6=-12 Horz: 1-2=-31, 2-3=-20, 3-4=-4, 5-6=14 Concentrated Loads (lb) Vert: 4=-224 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-0, 2-3=4, 4-5=-82, 2-6=-12 Horz: 1-2=-12, 2-3=-16, 3-4=-16, 5-6=-11 Concentrated Loads (lb) Vert: 4=-224 10) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-121, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=20, 5-6=6 Concentrated Loads (lb) Vert: 4=-290 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-8, 2-3=-12, 4-5=-121, 2-6=-20 Horz: 1-2=-12, 2-3=-8, 3-4=-8, 5-6=-20 Concentrated Loads (lb) Vert: 4=-274 12) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=22, 2-3=11, 4-5=-89, 2-6=-12 Horz: 1-2=-34, 2-3=-23, 3-4=-23, 5-6=18 Concentrated Loads (lb) Vert: 4=-231 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=14, 2-3=2, 4-5=-98, 2-6=-12 Horz: 1-2=-26, 2-3=-14, 3-4=-14, 5-6=18 Concentrated Loads (lb) Vert: 4=-240 14) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-121, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=1, 5-6=10 Concentrated Loads (lb) Vert: 4=-288 15) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 3 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08A Truss Type Half Hip Qty 4 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810495 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:04:58 2020 Page 3 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-LCuB75BzGMKIGm8p61huuAamArPtTcicWjj4rezVhw3 LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-121, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=1, 5-6=10 Concentrated Loads (lb) Vert: 4=-288 16) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-120, 2-6=-20 Concentrated Loads (lb) Vert: 4=-270 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-150, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=15, 5-6=4 Concentrated Loads (lb) Vert: 4=-315 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-41, 2-3=-44, 4-5=-150, 2-6=-20 Horz: 1-2=-9, 2-3=-6, 3-4=-6, 5-6=-15 Concentrated Loads (lb) Vert: 4=-303 19) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-150, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=0, 5-6=7 Concentrated Loads (lb) Vert: 4=-313 20) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-150, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=0, 5-6=7 Concentrated Loads (lb) Vert: 4=-313 21) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=4, 2-3=-28, 4-5=-128, 2-6=-12 Horz: 1-2=-16, 2-3=16, 3-4=-16, 5-6=-16 Concentrated Loads (lb) Vert: 4=-254 22) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=4, 4-5=-96, 2-6=-12 Horz: 1-3=-16, 3-4=16, 5-6=16 Concentrated Loads (lb) Vert: 4=-254 23) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-120, 2-6=-20 Concentrated Loads (lb) Vert: 4=-310 24) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-160, 2-6=-20 Concentrated Loads (lb) Vert: 4=-310 25) 3rd Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-50, 4-5=-120, 2-6=-20 Concentrated Loads (lb) Vert: 4=-300 26) 4th Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-150, 2-6=-20 Concentrated Loads (lb) Vert: 4=-300 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08B Truss Type Half Hip Qty 2 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810496 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:05:47 2020 Page 1 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-PdLjQrnijPVLeINDTp3NNW64ub73Royqoq4A3JzVhvI Scale = 1:15.4 1 2 3 4 5 7 6 13 3x6 3x4 3x6 3x4 3x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 0-3-6 0-3-6 3-1-5 2-9-15 4-7-8 1-6-3 5-11-4 1-3-12 6-3-8 0-4-4 -1-0-0 1-0-0 4-7-8 4-7-8 6-3-8 1-8-0 0-4-41-9-90-11-142-6-00-11-141-3-104.00 12 Plate Offsets (X,Y)-- [2:0-1-11,Edge], [2:0-2-0,0-2-4], [11:0-2-4,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.98 0.26 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.05 0.00 0.01 (loc) 2-7 2-7 6 2-7 l/defl >999 >999 n/a >999 L/d 480 360 n/a 240 PLATES MT20 Weight: 26 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-7, 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=533/0-3-8, 2=373/0-1-12 Max Horz 2=51(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-454/0, 3-13=-413/0, 4-5=-673/0, 5-6=-492/0 BOT CHORD 2-7=-19/390 WEBS 5-7=0/614 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 6-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Load case(s) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) . The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-225, 2-6=-20 Concentrated Loads (lb) Vert: 4=-80 2) Dead + 0.75 Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-50, 4-5=-215, 2-6=-20 Continued on page 2 March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08B Truss Type Half Hip Qty 2 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810496 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:05:47 2020 Page 2 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-PdLjQrnijPVLeINDTp3NNW64ub73Royqoq4A3JzVhvI LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 4=-70 3) Dead + Uninhabitable Attic Without Storage: Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-185, 2-6=-40 Concentrated Loads (lb) Vert: 4=-60 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=44, 2-13=35, 3-13=24, 4-5=-141, 2-6=-12 Horz: 1-2=-56, 2-13=-47, 3-13=-36, 3-4=11, 5-6=29 Concentrated Loads (lb) Vert: 4=23 5) Dead + 0.6 C-C Wind (Pos. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=20, 2-3=35, 4-5=-130, 2-6=-12 Horz: 1-2=-32, 2-3=-47, 3-4=-36, 5-6=-18 Concentrated Loads (lb) Vert: 4=23 6) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-39, 4-5=-204, 2-6=-20 Horz: 1-2=-15, 2-3=19, 3-4=-28, 5-6=-27 Concentrated Loads (lb) Vert: 4=-59 7) Dead + 0.6 C-C Wind (Neg. Internal) Case 2: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-35, 2-3=-39, 4-5=-204, 2-6=-20 Horz: 1-2=15, 2-3=19, 3-4=19, 5-6=21 Concentrated Loads (lb) Vert: 4=-69 8) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=19, 2-3=8, 4-5=-147, 2-6=-12 Horz: 1-2=-31, 2-3=-20, 3-4=-4, 5-6=14 Concentrated Loads (lb) Vert: 4=6 9) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-0, 2-3=4, 4-5=-147, 2-6=-12 Horz: 1-2=-12, 2-3=-16, 3-4=-16, 5-6=-11 Concentrated Loads (lb) Vert: 4=6 10) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-186, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=20, 5-6=6 Concentrated Loads (lb) Vert: 4=-60 11) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-8, 2-3=-12, 4-5=-186, 2-6=-20 Horz: 1-2=-12, 2-3=-8, 3-4=-8, 5-6=-20 Concentrated Loads (lb) Vert: 4=-44 12) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=22, 2-3=11, 4-5=-154, 2-6=-12 Horz: 1-2=-34, 2-3=-23, 3-4=-23, 5-6=18 Concentrated Loads (lb) Vert: 4=-1 13) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=14, 2-3=2, 4-5=-163, 2-6=-12 Horz: 1-2=-26, 2-3=-14, 3-4=-14, 5-6=18 Concentrated Loads (lb) Vert: 4=-10 14) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-186, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=1, 5-6=10 Concentrated Loads (lb) Vert: 4=-58 15) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 3 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss T08B Truss Type Half Hip Qty 2 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810496 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 16:05:47 2020 Page 3 Probuild - Builders First Source, Mooresville, IN 46158 ID:79f8i791GzM_4E?VDbUYadzunxt-PdLjQrnijPVLeINDTp3NNW64ub73Royqoq4A3JzVhvI LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-16, 2-3=-21, 4-5=-186, 2-6=-20 Horz: 1-2=-4, 2-3=1, 3-4=1, 5-6=10 Concentrated Loads (lb) Vert: 4=-58 16) Dead: Lumber Increase=0.90, Plate Increase=0.90 Plt. metal=0.90 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-185, 2-6=-20 Concentrated Loads (lb) Vert: 4=-40 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-215, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=15, 5-6=4 Concentrated Loads (lb) Vert: 4=-85 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-41, 2-3=-44, 4-5=-215, 2-6=-20 Horz: 1-2=-9, 2-3=-6, 3-4=-6, 5-6=-15 Concentrated Loads (lb) Vert: 4=-73 19) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-215, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=0, 5-6=7 Concentrated Loads (lb) Vert: 4=-83 20) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-47, 2-3=-50, 4-5=-215, 2-6=-20 Horz: 1-2=-3, 2-3=0, 3-4=0, 5-6=7 Concentrated Loads (lb) Vert: 4=-83 21) Dead + 0.6 C-C Wind Min. Down: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=4, 2-3=-28, 4-5=-193, 2-6=-12 Horz: 1-2=-16, 2-3=16, 3-4=-16, 5-6=-16 Concentrated Loads (lb) Vert: 4=-24 22) Dead + 0.6 C-C Wind Min. Upward: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-3=4, 4-5=-161, 2-6=-12 Horz: 1-3=-16, 3-4=16, 5-6=16 Concentrated Loads (lb) Vert: 4=-24 23) 1st Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-185, 2-6=-20 Concentrated Loads (lb) Vert: 4=-80 24) 2nd Dead + Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-225, 2-6=-20 Concentrated Loads (lb) Vert: 4=-80 25) 3rd Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-50, 4-5=-185, 2-6=-20 Concentrated Loads (lb) Vert: 4=-70 26) 4th Dead + 0.75 Roof Live (unbalanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-20, 4-5=-215, 2-6=-20 Concentrated Loads (lb) Vert: 4=-70 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss TG01 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810497 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:21 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BCcbjDKPH3fVWlC9SMB0JNqtTa3CFLmCgQdT8uzViBW Scale = 1:31.3 1 2 3 4 5 6 7 8 15 14 13 12 11 10 916 17 18 19 20 21 22 3x6 4x10 4x8 10x10 3x4 3x4 3x6 4x8 4x8 5x16 MT18HS 6x10 8x8 3x6 2x4 2-3-3 2-3-3 3-11-0 1-7-13 6-11-0 3-0-0 8-11-0 2-0-0 13-0-13 4-1-13 17-10-0 4-9-3 2-3-3 2-3-3 3-11-0 1-7-13 8-11-0 5-0-0 13-0-13 4-1-13 17-10-0 4-9-3 18-10-0 1-0-0 0-5-124-11-40-5-121-4-06.00 12 Plate Offsets (X,Y)-- [10:0-4-0,0-4-8], [12:0-4-0,0-5-0], [13:0-9-10,0-3-15], [14:Edge,0-3-8], [15:0-3-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.76 0.71 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.30 0.17 (loc) 12-13 12-13 7 l/defl >999 >713 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 260 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 3-14: 2x4 SP 2400F 2.0E, 12-13: 2x6 SP 2400F 2.0E 4-11: 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud *Except* 2-13,5-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 7=0-3-8 Max Horz 1=-64(LC 25) Max Grav 1=3405(LC 1), 7=3007(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5965/0, 2-3=-14086/0, 3-4=-7462/0, 4-5=-7272/0, 5-6=-4088/0, 6-7=-5682/0 BOT CHORD 1-15=0/5150, 14-15=0/1775, 13-14=0/1339, 3-13=0/4544, 12-13=0/13104, 9-10=0/4954, 7-9=0/4954 WEBS 2-15=-3253/0, 2-13=0/7295, 13-15=0/4490, 3-12=-6505/0, 5-12=0/5794, 10-12=0/4206, 6-10=-1582/0, 6-9=0/1389 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc, 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-7-0 oc, Except member 13-2 2x4 - 1 row at 0-9-0 oc, member 13-15 2x4 - 1 row at 0-9-0 oc, member 12-3 2x4 - 1 row at 0-9-0 oc, member 12-5 2x4 - 1 row at 0-9-0 oc, member 10-5 2x4 - 1 row at 0-9-0 oc, member 10-12 2x4 - 1 row at 0-9-0 oc, member 10-6 2x4 - 1 row at 0-9-0 oc, member 6-9 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 679 lb down at 1-10-4, 679 lb down at 3-9-4, 679 lb down at 5-10-4, 679 lb down at 7-10-4, 685 lb down at 9-10-4, 685 lb down at 11-10-4, and 685 lb down at 13-10-4, and 166 lb down at 14-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.Continued on page 2 March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss TG01 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810497 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:21 2020 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-BCcbjDKPH3fVWlC9SMB0JNqtTa3CFLmCgQdT8uzViBW LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-8=-60, 1-14=-20, 12-13=-20, 7-11=-20 Concentrated Loads (lb) Vert: 14=-679(F) 16=-679(F) 17=-679(F) 18=-679(F) 19=-685(F) 20=-685(F) 21=-685(F) 22=-166(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810498 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:23 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-7bkL8vMfpgvDl3LYZnDUOovGkOlMjHMV7k6aCnzViBU Scale = 1:26.9 1 2 3 456 7 8 3x6 4x6 3x6 3x12 5-9-8 5-9-8 11-7-0 5-9-8 5-9-8 5-9-8 11-7-0 5-9-8 0-7-124-6-10-7-128.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.73 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.09 0.01 (loc) 1-4 1-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-3-8 Max Horz 1=-64(LC 25) Max Grav 1=2458(LC 1), 3=2221(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2520/0, 2-3=-2520/0 BOT CHORD 1-4=0/1985, 3-4=0/1985 WEBS 2-4=0/2501 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 360 lb down and 20 lb up at 0-1-12, 685 lb down at 2-0-4, 685 lb down at 4-0-4, 685 lb down at 6-0-4, and 685 lb down at 8-0-4, and 685 lb down at 10-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 1-3=-20 Concentrated Loads (lb) Vert: 1=-348(F) 4=-685(F) 5=-685(F) 6=-685(F) 7=-685(F) 8=-685(F) March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss V01 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810499 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:26 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-YAQUmxOY6bHocW47FvnB0QXhSbr3wnnxpiLEp5zViBR Scale = 1:20.0 1 2 3 5 4 6 7 3x4 3x4 4x6 3x4 2x4 6-10-9 6-10-9 0-11-4 0-11-4 6-10-9 5-11-5 2-6-02-11-100-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.94 0.41 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=6-10-1, 3=6-10-1, 4=6-10-1 Max Horz 5=-67(LC 10) Max Uplift 5=-132(LC 3), 3=-3(LC 12) Max Grav 3=201(LC 1), 4=362(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 0-11-4, Exterior(2R) 0-11-4 to 3-11-4, Interior(1) 3-11-4 to 6-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 5=132. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss V02 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810500 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:29 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-yl5cOyQQPWgMT_piw1Kud39OeoxM79WNVgZuQQzViBO Scale = 1:10.9 1 2 3 4 3x4 3x4 3x4 3x4 4-2-9 4-2-9 0-11-4 0-11-4 4-2-9 3-3-5 1-2-01-7-100-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.18 0.18 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=4-2-1, 3=4-2-1 Max Horz 4=-31(LC 10) Max Grav 4=137(LC 1), 3=137(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss V03 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810501 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:31 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-u8DNpeSgx8w4iHz41SMMjUEhmccqb3Kgz_2?UJzViBM Scale = 1:14.9 1 2 3 4 3x4 4x6 3x4 2x4 0-0-6 0-0-6 7-5-7 7-5-1 3-8-11 3-8-11 7-5-7 3-8-11 0-0-42-5-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.33 0.18 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-4-11, 3=7-4-11, 4=7-4-11 Max Horz 1=34(LC 11) Max Uplift 1=-10(LC 12), 3=-10(LC 12) Max Grav 1=139(LC 1), 3=139(LC 1), 4=241(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job J19904093 Truss V04 Truss Type Valley Qty 1 Ply 1 Pyatt Builders - 50 TG - Reindl Job Reference (optional) I40810502 8.240 s Mar 9 2020 MiTek Industries, Inc. Mon Mar 30 15:46:32 2020 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:79f8i791GzM_4E?VDbUYadzunxt-MKnl0_TJiR2xKRXHbAubFhnxz0zxKWGqCeoY0lzViBL Scale = 1:8.5 1 2 3 3x4 3x4 3x4 0-0-6 0-0-6 3-5-7 3-5-1 1-8-11 1-8-11 3-5-7 1-8-11 0-0-41-1-130-0-48.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-5-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-4-11, 3=3-4-11 Max Horz 1=-13(LC 10) Max Grav 1=100(LC 1), 3=100(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. March 30,2020 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths