HomeMy WebLinkAboutA000-COVER-SHEET-Rev.1GENERAL PROJECT NOTES
L EACH CONTRACTOR SHALL BECOME COMPLETELV FAMILIAR W ITH ALL ASPECTS OF
THE WORK, EVEN THOSE AREAS DESIGNATED TO BE PROVIDED BV OTHERS. THIS
FAMILIARIZATION INCLUDES Fl1LL AND COMPLETE UNDERSTANDING OF THE WORK
DESCRIBED ON ALL SHEETS OF TH E DRAWINGS FAI W RE BV THE CONTRACTOR TO
BECOME COMPLETELV FAMILIAR OF ALL ASPKTS OF THE W ORK SHALL NOT RELIEVE
THE CONTRACTOR OF THE RESPONSIBILITV TO PROVIDE MATERIALS ASSEMBLIES, OR
SERVICES INDICATED IN THE CONTRACT DOCU MENTS.
2. ALL WORK SHALL COMPLV W ITH THE REQUIREMENTS OF ALL APPLICABLE STATE
AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFVING THE
CURRENT APPLIGABLE BU ILDIN6 CODE(5) FOR THEIR RESPKTNE SCOPE OF WORK.
ALWAVS ABIDE BV THE MOST RESTRICTIVE CODE.
3. FIELDVERIFVALLEXISTIN6CONDITIONSANDMEASUREMENTSINDICATEDONTHE
DRQW INGS AND REPORT ANV DISCREPANCV THROUGH THE GENERAL CONTRACTOR
TO PARALLEL DESIGN GROUP BEFORE BEGINNING ANV CONSTRUCTION.
4. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING
ALL ON-SITE ACTIVITIES; SUCH A5, BUT NOT LIMITED TO, WORK SCHEDU LE,
MATERIALS STORAGE AN D HANDLING, DELNERIES, ACCE55 TO THE W ORKSITE,
TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETV PROCEDURES DURIN6
CONSTRUCTION. THE CONTRACTOR SHALL AL50 COORDINATE WORK "BY OTHERS"
W ITH H IS/HER OW N ACTIVITIES AS NECESSARV TO EXECUTE THE OVER4LL PROIECT
SCOPE.
5. GENERAL CONTRACTOR TO REVIEW DOCU MEMS IN DETAIL AND COMMUNICATE
ANV ITEMS THAT MAV REQUIRE LEAD TIMES. CONTRACTOR TO COORDINATE PROJECT
SCHEDU LE ACCORDINGLV AND COMMUNICATE TO TEAM ANV DKISIONS THAT NEED
TO BE MADE TO KEEP PROJEQ SCHEDULE ON TRACK. CONTRACTOR IS RESPONSIBLE
FORDELAVSWHENLEADTIMESARENOTPROPERLV WMMUNICATEDTOOWNER
AND PARQLLEL DESI6N GROUP.
6. NO SUBSTITl1TION5 FOR SPKIFICALLV NAMED PRODUCTS/MATERIALS W ILL BE
ALLOWED WITHOUT PRIOR APPROVAL FROM PARALLEL DESIGN GROUP. PRODUCT
CHANGE SUBMITTALS SHOULD BE COMMUNICATED TO PARALLEL DESIGN GROUP
ALLO W ING ADEQUATE TIME TO RESPOND.
Z CONTAQ THE DESIGNER IMMEDIATELV IF, IN THE FlEL�, CONFLICTS ARE
DISCOVERED BETW EEN COMPONENTS OF DIFFERENT SVSTEMS THAT PREVENT THE
INSTALLATION OFTHOSE COMPONENTS AS INDICATED ON THE DRAW INGS Q.E.
WHERE EXISTING MECHANICAL DUCTWORK MAV PREVENT THE INSTALLATION OF
LI6HTIN6 FIXTURES AS INDICATED ON THE CEILING PLAN).
8. SHOP DRAW INGS OR CATALOG CUTS MUST BE SUBMITTED TO PARALLEL DESIGN
GROUP FOR APPROVAL ON ALL MATERIALS/PRODUCTS IF THE DRAWIN65 DO NOT
INDICATE A SPECIFlC MANUFAQURER OR MODEL NUMBER.
9. PROVIDE SUBMITTAL SHOP DRAW INGS IN A TIM ELV FASHION TO ALLO W
SUFFIQENTTIME FOR CHEIXING, APPROVAL, OR�ERING, FABRICATION, AND
DELNERV OF MATERIALS AND EQUIPMENT.
10. ALL MATERIAL AND EQUIPMENT OF IN DUSTRV STANDARD QUALITV SPKIFlED OR
NOT, AND W ITH TH E LIMITATION OF THE CONTRACT DOCUMENTS TO CAUSE THE
INSTALLATION TO FUNCTION IN ACCORDANCE W ITH THE INTENTION AND OBIECTNE
OF THE FINISHED PROJECT.
11. EACHCONTRACTORSHALLFULLVREVIEWDRAWINGSHEETSTOFULLY
UNDERSTAND NEW WORK AND EXISTING CONDITIONS TO �ETERM W E FULL EXTENT
OF RESPONSIBILITIES FOR EACH RESPECTNE TRADE IN ADDITION TO COORDI NATIN6
FULL EXTENT OF RESPONSI BILITIES W ITH ALL OTHER TRADES FlELD WORK ORDERS &
CHANG E ORDERS W ILL NOT BE APPROVED FOR ANV CONDITIONS OR CONFLIQS
THAT COULD HAVE BEEN ACCOUNTED FOR BV THE BIDDER DURIN6 PRE-BID FlELD
INSPKTION AN D AFTER AWAftD OF CONTRACT.
12. THE GENERQL CONTRACTOR IS REQUIRED TO PATCH AND REPAIR ANV DAMA6ED
EXISTING SU RFACE TO MATCH NEW.
13. WHENREQUBEDBVSTATEBUILDINGCODE,THECONTRACTOR(5)SHALL
PROVIDE DESIGN/BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR
FIRE SUPPRESSION. DRAW INGS SHALL BE CERTIFIE� BV A LICENSED ENGINEER AND
SU BMITTED BV THE CONTRACTOR FOR STATE DESIGN REVIE W.
14. ALL EQU IPMENT, MATERIALS AND/OR FIXTURES SHALL BE INSTALLED I N STRIQ
ACCORDANCE WITH THE MANUFACTURER'S REGOMMENDATIONS OR INSTRUCTIONS.
ii EXENTEATHOROUGH FINALQEANANDINSPECTIONOFTHESPACEUPON
COMPLETION OF THE PROIKT. ALL SU RFACES, FIXTU RES, AND EQUIPMENT SHALL BE
CLEAN, AND THE SPACE SHALL BE TU RNED OVER TO THE OW NER IN A CONDITION
THATREPRESENTSTHEHIGHESTLEVELOFCAREANDPROFESSIONALISM ENSUREALL
GENERAL CONTRACTOR INSTALLE� APPLIANCES WORK & DO NOT LEAK.
16. PROVIDETOTHEOWNERALLOPERATIONAND/ORMAIMENANCEMANUALS,OR
INSTRUQIONS FOR ALL EQUIPMENT AND SVSTEMS AT THE GOMPLETION OF THE
PROJECT.
1]. DO NOT SCALE DRAWIN65. DIMENSIONS 60VERN. ALL DIMENSIONS ARE FROM
FINISHED FACE OF WALL TO FINISHED FACE OF WALL.
18. CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW
BLINDS.
19. THE GENERAL CONTRACTOR SHALL eE RESPONSIBLE FOR VERIFVING THE
REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, INSPKTIONS,AND FEES.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED
DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL
AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BV
THE GENERAL CONTRACTOR U NLESS STIPULATED OTHERW ISE IN THE
O W NE WCONTRACTOR AGREEMENT.
20. NOTE REGAROING PROJECTS WITHIN MARION COUNTV: LOCAL ORDINANCE
REQUIRES ONE SET OF CONSTRUQION DRAW INGS FOR CLA55 1 STRUCTURES, THAT
ARE �ESIGNED W ITH A FlRE PROTECTION AND LIFE SAFETV SVSTEMS Q.E FlRE
ALARMS), BE SUBMITTED TO THE IN�IANAPOLIS FIRE �EPARTM ENT QFD) FOR THE
PURPOSE OF CONDUCTING A FIRE DEPARTM ENT PLAN REVIEW AND ON-SITE
INSPKTIONS. DRAW ING SET SHOULD INCLUDE ARCH, STRUQ, M ECH, ELEC,
SPRINKLER, FlRE ALARM, AND SITE/CIVLL (W HERE APPLICABLE). DRAW INGS MAV BE
DELNERED OR MAILED TO THE IFD PLAN REVIEW DIVISION (1200 MADISON AVENUE,
INDIANAPOLIS, IN 46225, ATTENTION: TJ. BURNS). INCLUDE THE DMD STRUCTURAL
PERMIT NUMBER (STR-XXXXXX) WITH THE DRAWING SET. THE GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR COOROINATING THE SUeM15510N OF
THESE DRAWINGSANDTHE REQUIRED FEETOTHE IFO PLAN REVIEW DIVISION.
CONTACT THE IFD WITH QUESfIONS REGAFDIN6 THIS REQUIREMENT (31�-32]-5529).
DEMOLITION NOTES
1. ALL EXISTING EQUIPMENT, FIXTU RES, ETC. SHALL REMAIN PROPERTV OF THE
O WNER. ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION SHALL BE RETA W ED
FOR THE OWNER'S INSPKTION. ONLV ITEM550INSPECTED AND REJECTED BV THE
OWNER SHALL BE DISPOSED.
2 CONTRACTOR TO VISIT SITE TO BECOME FAMILIAR W ITH EXISTING CONDITIONS.
DEMOLITION �RAW INGS ARE A REFERENCE TO AID CONTRACTOR W EVALUATION OF
THE EXTENT OF THE DEMOLITION, BUT SHALL NOT BE CONSIDERED ALL MQUSNE.
CONTRACTOR TO FlELD VERIFV ALL EXISTING CONDITIONS, DIMENSIONS, ETC.
REFERENCE NEW CONSTRUCTION DRAWINGS TO DETERMME THE FULL EXTENT OF
NECESSARV DEMOLITION.
3. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAG ED AS A RESULT OF THIS PROJKT UNLE55 SPECIFICALLV
NOTE� OTHERWISE ON THE DRAWINGS. THE CONTRACTOR SHALL VERIFV IN THE
FIELD, PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL CONTACT PARALLEL DESIGN GROUP IMMEDIATELV IF THE
CONTRACTOR(5) IN THE FlELD SUSPKT THAT AN ITEM NOTED FOR DEMOLITION
APPEARS TO BE STRUCTURAL OR OTHERW ISE LOAD-BEARING. THE CONTRACTOR IS
SOLELV RESPONSIBLE FOR INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL
SVSTEM.
4. EACH TRADE CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION WORK REQUIRED
OR NOTED FOR THE INSTALLATION OFTHE NEW WORK.
5. EACH TRADE CONTRAQOR IS RESPONSIBLE TO REFER TO NEW CONSTRUCTION
DRAW INGS FOR ADDITIONAL PATCHING AND PREPARATION W ORK RELATED TO THE
DEMOLITION ITEMS.
6. WHEREEQUIPMENT,FIXTURES,ORFINISHESAREMOVEDFROMANVOTHERPARTOF
THE BUILDING TO BE REUSED IN THE PROJEQ AREA, THE CONTRACTOR SHALL
INC W DE IN THEIR SCOPE OF WORKANV NECESSARV PATCHING OR REPAIRING OF THE
REMAINING AREAS FROM W HERE THE ITEMS W ERE RELOCATED, UNLE55 OTHERWISE
DIRECTED BV OWNER.
]. CHECK EXISTING FLOOR LEVEL BEFORE INSTALLATION OF NEW FLOORING. PREPARE
FLOOR WITH CEMENTITIOUS LEV ELING COMPOUND PRIOR TO INSTALLATION OF NEW
FLOOR RNISH AS REQUIRED TO MAINTAM LEVEL.
8. REMOVE ALL ITEMS ASSOCTIATED W ITH DEMOLISHED WALL IF NOT NOTED OR
SHOWN OTHERWISE. SALVAGE ANV ITEMS IS 600D CONDITION FOR REUSE IN NEW
CONSTRUCTION, e.g., OUTLETS.
9. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OFALL EXISTIN6
SURFACES, MATERIALS, COMPONENTS, ETCTO REMAIN OR BE RELOCATED. ANY
DAMAGE TO THESE RESULTING FROM PERFORMANCE OF WORKSHALL BE REPAIRED BV
THE CONTRACTOR TO TH E SATISFACTION OF THE OW NER AND PARALLEL DESIGN
GROUP AT NO ADDITIONAL EXPENSE TO THE OW NER..
10. COMPLV W ITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES AND
REGULATIONS. ALWAVS ABIDE BV THE MOST RESTRICTNE CODE.
11. THE CONTRAQOR SHALL PROVIDE TEMPORARV DUST PROTKTION AS REQUIRED
BV THE O W NER TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING
OUT OF THE PROIKT AREA. THE OW NER SHALL CONFIRM ALL DUST PREV ENTION
MEASURE/LOCATIONS, AND SHALL DETERMINE ANV GHANGES TO THESE MEASURES.
12 REMOVEDUSTANDDEBRISFROMNEWLVEXPOSEDSURFACES.
13. CONTRACTOR TO PROVIDE AN "AS-BUILT" SET INDICATING THE LOCATION OF ALL
PERMANENTLVABANDONEDSVSTEMS.
14. 6EN ERAL CONTRACTOR TO PROVIDE RECVCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH A5, METAL STUDS,
DRVWALL, CARPET, CEILING TILES, DOORS,GLASS,AND CABMETRV.
MECHANICAL &
ELECTRICAL NOTES
1. POWER AND COMMl1NICATION PLAN IS TO SHOW ELKTRICAL, VOICE/DATA
RECEPTACLES AND N LOCATIONS. ELECTRICAL CONTRACTOR TO FlELD VERIFV
LOAD CAPACITIES AND AVAILABILITY. PARALLEL DESIGN GROUP AN� THEIR
ARCHITEQ ARE NOT RESPONSIBLE FOR ANV MECHANICAL OR ELEQRICAL
ENGINEERING.
2. REFLEQED CEILING PLAN IS TO SHOW LIGHT FlXTURE, DIFFUSER AND SWITCH
LOCATIONS ON LV. PARALLEL DESIGN GROUP AN D THEIR ARCHITECT ARE NOT
RESPONSIBLE FOR ANV MECHANICAL OR ELECTRICAL ENG W EERING.
3. ELECTRICALCONTRACTORRESPONSIBLEFORRELOCATIONAND/OR
ADDITION OF HORN STROBES, FIRE ALARM STATIONS AN D EXIST SIGNS AS
REQUIRED BV CODE.
4. VEPoFV IF ANV SPEGIAL EQU IPMENT W ILL REQUIRE ADDITIONAL AIR FLOW.
PROVIDE ADDITIONAL HVAC REQUIREMENTS AFTER APPROVAL FROM TENANT.
REVISE ZONING AS NEEDED.
5. PW MBING, FlRE SUPPRESSION, AND FIRE ALARM SVSTEMS SHALL BE DESIGNED
AND INSTALLED BV THE RESPECTIVE DESIGN/BUILD CONTRACTORS PER
AGREEMENT WITH THE OWNER. ALL TRADES SHALL DESIGN AND INSTALL THEIR
RESPECTIVE SVSTEMS IN ACCORDANCE W ITH ALL APPLICABLE STATE AN� LOCAL
BUILDING CODES. COORDINATE W ITH THE ARCHITEQ IF ADDITIONAL
WFORMATIONISRE UIREDINORDERTODOTHEWORKINTHEFlELD.PARALLEL
Q
DE51G N GROUP AND THEIR ARCHITEQ ARE NOT RESPONSIBLE FOR ANV
ENGINEERIN6 FOR THESE SVSTEMS.
6. COORDINATE CIRCUITRY REQUIREMENTS FOR FURNITURE SVSTEMS W ITH
TENANT, BEFORE RUNNING W IRING TO JUNCTION BOXES.
J. CENTER IN CEILING TILES RECESSED DOWNLIGHTS, SMOKE DETECTORS,
SPR W KLER HE4D5, AND EXIT SIGNS, UNLE55 OTHERW ISE NOTED.
9. REVIEW FIRE �ETECTION DEVICE LOCATIONS W ITH TENANT PRIOR TO
INSTALLATION.
9. THE DESIGN/BUILD CONTRACTOR SHALL GOMPLV WITH THE INDIANA
BUILDING CODE, THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS,
CODES, RULES AND REGULATIONS THAT APPLV TO �ESIGN AN D INSTALLATION
OF RRE SPRINKLER/FlRE Sl1PPRE5510N SVSTEMS.
MECHANICAL &
ELECTRICAL NOTES CONTINUED
10. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER H EADS AS REQUIRED.
PROVIDE MISSING COVER/ESNTCHEON PLATES FOR SPR W KLER HE4D5 W HERE
APPLICABLE. FIELD VERIFV EXISTING CONDITIONS PRIOR TO THE START OF
WORK.
11. THE FIRE PROTECTION CONTRAQOR SHALL 6ENERATE ALL REQU IRED
DRAW INGS. AND SHALL FILE THOSE DRAW INGS, AND RELATED DONMENTS,
W ITH THE STATE AND LOCAL AUTHORITIES HAVING lURISDICTION OVER THE
PROIKT.
FINISH NOTES
1. ALL MATERIALS TO BE DELNERED IN THEIR ORIGINAL PACKAGING WITH
MANUFACTURERS LA8EL5. CONTRACTOR WILL BE RESPONSIBLE FOR RECEIVING,
STORING AND PROTECTING MATERIALS FROM ANY DAMAGE 9V MOISTURE, WIND,
SUN ABUSE, OR ANV HARMFUL EFFEQS. oAMAGED MATERIALS W ILL BE
REJECTED AND MUST BE REPLACED BV TH E CONTRAQOR.
2. REMOVEALL PLATESANDSWITCHESBEFOREPAINTINGANDREATTACH
AFTERWARDS.
3. ALL REMAININ6 PAINT (1 GALLON MINIMUM) TO BE LEFT W ITH THE OW NER.
4. WALLCOVERINGSHALLBEFROMTHESAMEPRODUCTIONRUN.
5. 00 NOT LOCATE WALLCOVERING SEAMS ON CORNERS. wRAP 6" BEVOND
I NSIOE OR OUTSIDE CORNERS AS INDICATED ON THE FINISH PLAN W HERE
CHANGE OF WALLCOVERING LOCATION OCCURS.
6. CONTRACTOR TO REMOV E EXCE55 ADH ESIVE IMMEDIATEDLV FROM SURFACE
OR WALLCOVERING AS EACH JOINT OR SEAM IS MADE AND BEFORE PROCEEDING
TO THE NEXT JOINT OR SEAM.
]. ALL WALLCOVERING SEAMS ARE TO BE NT STRAIGHT. ASSURE INSTALLATION
IS SENRE, SMOOTH, CLEAN,AND WITHOUT WRINKLES, BUBBLES, GAPS,AND/OR
OVERLAPS.
e. FOR ALL NE W DRV W ALL INSTALLATIONS, INSTALL AS RECOMMENOEo BV THE
GV PSU M ASSOCIATION. (SUCH A5, CONTROL JOINTS, FINISH LEVELS, FASTENERS,
TAPING DETAILS, CORNER BEADS, ETCJ
9. TRANSITION OF DIFFERENT FLOORING MATERIALS SHALL OCCUR AT THE
CENTERLINE OF THE DOOR.
10. CONTRAQOR TO PROVIDE AND WSTALL TRANSITION STRIP BETWEEN
DISSIMILAR FLOORING MATERIALS. TRANSITION STRIP IS TO BE SCH W TER OR
EQUAL WITH BRUSHED ALUMINUM FlNISH OR IS TO 8E VINVL AND MATCH VINVL
BASE COLOR (IE: WHERE VCT MEETS CARPET). CONTRACTOR TO DETERMWE
TVPE OF SCH LUTER STRIP BASEO ON DISSIMILAR FLOORING MATERIALS.
CONTRAQOR TO VERIFV TVPE OF TRANSITION W ITH PARALLEL DESIGN, IF NOT
NOTED, PRIOR TO PLACING ORDER.
11. SUBFLOOR MUST BE LEVEL, SOUND, RIGID, CLEAW FREE OF ANV DEBRIS, AND
PERMANENTLV DRV PRIOR TO INSTALLATION. THE INSTALLATION OF FlNISH
FLOORING MATERIALS SHALL SERVE AS AQEPTANCE OF SLAB CONDITION.
12 FLOORINGMATERIALSSHALLBEFROMTHESAMEPRODUQIONRUN.
13. CONTRACTO R SHALL REPAI R, REFlNISH OR TOUCH-UP SURFACES DAMAGED
BV SUBSEQUENT WORK (EXAMPLE W HERE NEW OUTLETS/FIXTURES HAVE BEEN
INSTALLED)
14. LOW VOC CONTENT PAINT AND ADHESIVES TO BE USED THROUGHOUT
PROJECT.
15. REVIEWANDABIDEBVALLMANUFAQURERINSTALLATIONINSTRUCTIONS
PRIOR TO MSTALLATION OF FlNISH MATERIALS. MANUFACTURER
RECOMMENDED ADHESIVES/SEALANTS TO BE USED.
16. UPON COMPLETION OF ALL FlNISH APPLICATIONS, ALL MATERIALS AND
EQUIPMENT SHALL BE REMOVED. CONTRAQOR SHALL INSURE THAT ALL AREAS
ARE LEFf CLEAN AN� DAMAGE FREE.
1Z ANV VARIATION IN PATTERN,TE%TURE, COLOR OR ANV OTHER �EFEQ
SHOULD BE BROUGHT TO THE ATTENTION OF PARALLEL DESIGN GROl1P FOR
DIRECTION AND APPROVAL.
FIRE PROTECTION NOTES
L FlRE PROTECTION WORK IS TO BE PROVIDED BV DESIGN/BUILD SERVICES UNOER
THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SVSTEM. PARALLEL
DESIGN GROUP IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR
RENOVATION OF THE FIRE SPRINKLER SVSTEM.
2. THE DESIGN/BUILD CONTRACTOR SHALL COMPLV WITH THE INDIANA BUILDING
CODE, THE INDIANA FIRE CODE, AND ALL OTH ER APPLICABLE LAW 5, CODES, RULES AND
RE6ULATIONS THAT APPLV TO DESIGN AN� WSTALLATION OF FlRE SPRINKLER/FlRE
SUPPRESSION SVSTEMS.
3. THE FIRE PROTEQION CONTRACTOR SHALL 6ENERATE ALL REQUIRED �RAW INGS,
AND SHALL FILETHOSE DRAWIN65, AND RELATED DOCUMENTS, WITH THE STATE AND
LOCAL AUTHORITIES HAVING JU RISDICTION OVER THE PROJECT.
4. PROVIDENEWORRELOCATEEXISTINGSPRINKLERHEADSASREQUIRED. PROVIDE
MISSING COVER/ESNTCHEON PLATES FOR SPRINKLER HEADS W HERE APPLICABLE.
FlELD VERIFY EXISTING CONDITIONS PRIORTO THE START OF WORK.
i FlREEXTINGUISHERS: CONTRACTORTOENSUREALLNEWANDE%ISTINGFlRE
E%TINGUISHERS ARE MSTALLED ACCORDING TO NFPA 10. COORDINATE W ITH
OWNE WLANDLOR� ON E%TINGUISHER TVPE AN� HOUSING. MA%IMUM TRAVEL
oISTANCE OF J s FEET FROM ANv POINr To A v15laLE ExTINGUISHER.
SCHWARZ PARTNERS
10 WEST CARMEL DRIVE - SUITE 300
CARMEL, INDIANA 46032
PROJECT INFORMATION
PROJECT SQUARE FOOTAGE
REMODEL 22,289SQFT
OCCUPANCY: B(BUSINESS)
A-3 (ASSEMBLY
ACCESSORY
TO B)
CONSTRUCTION TYPE: I I B
PROJECT TEAM
INTERIOR DESIGNER/ARCHITECT
PARALLEL DESIGN GROUP
8801 RIVER CROSSING BLVD.
SUITE 140
INDIANAPOLIS,IN 46240
PH 317.721.4399
bri an a@ paral I e I d g.co m
DATE
� �
N 7 m �
� 0 (� m
O N -
N
APPROVAL FOR CONSTRUCTION
THE TENANT/CLIENT AGREES THAT THESE DRAW INGS AND SPECIFlCATIONS
REPRESENTTHE ENTIRE SCOPE OF WORK FOR THE IMPROVEMENTS TO BE
PROV IDED. THE TENANT/CLIENT'S SIGNATURE BELOW REPRESENTS ACCEPTANCE
OF THE FINAL DESIGN. ANV CHANGES TO THIS SCOPE OF WORK INITIATED BV THE
TENANT/CLIENT W ILL CAUSE CHANGES IN THE TOTAL COST TO THE TENANT/CLIENT
AND IN THE COMPLETION DATE FOR THE PROJEQ.
TENANVCLIENT REPRESENTATNE NAME PRIME�
TENANT/CLIENT REPRESENTATNE SIGNATU RE
_ ,ow°.m��e.��....o. �_ �
o.
' .nams Fncmn
MAP LOCATION
N
�
W
Z
�
�
a
a
N
a
�
2
N
�
�
Z
w
U
�
�
a
�
Q
Q
�
O`^
V
Q
0
0
M
w
H N
� m
� O
�
i �
w\ �
/ Z
� Q
� Q
w Z
� J
a�
U �
� Q
� �
w>
>
0
Na.119000A9
STATE OF
COVER SHEET
+1000
�
RELEA5E0 FOR CONSTRUCTION
Suhjec� �o compliance with all regula�ions
04 S�a�e antl Local Codes
City of Carmel
`�a,:a���'.`! �,�:;valM��
DATE: 04�Z3�2O
= 'a
�'��N ,�„ . ,.
�
o E
a o
�
« �
�n v
�
, � �
iii� m � a
II � b �
O -
o Z m
iilll V N �
O N
i; > a �
. � C n
' .' O � m
i� �
� �.�� �� � W-
DRAWING INDEX
A000 COVERSHEET
A003 ACCESSIBILITY
A001 LIFE SAFETY PLAN
A004 WALLTYPES
A101 FLOOR PLAN
AlO1D DIMENSION PLAN
A110 DOORSCHEDULES
A120 ENLARGED RESTROOM PLANS
A201 REFLECTEDCEILINGPLAN
A301 POWERANDDATA
A401 FINISHPLAN+SPECIFICATIONS
A500 INTERIOR ELEVATIONS
A501 INTERIOR ELEVATIONS
Ih__ �
,_, - " ��
� ��
q
�
� �
, ��
�� ,
� -
II , _ a�y� �1 ::.,'
- i7�6'�R11! �� _� ..;_� I
■1�:., �
- u I
- . N ; _ �-^--
� N
�.,_. _ . - ...
� �� o�[
KEY PLAN